Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Dis Esophagus ; 33(12)2020 Dec 07.
Article in English | MEDLINE | ID: mdl-32607563

ABSTRACT

Esophageal baseline impedance (BI) acquired during esophageal contraction (contractile segment impedance [CSI]) is proposed to improve BI accuracy in gastroesophageal reflux disease (GERD). We evaluated associations between CSI and conventional and novel GERD metrics. We analyzed high-resolution impedance manometry (HRIM) and ambulatory pH-impedance studies from 51 patients (58.6 ± 1.5 years; 26% F) with GERD symptoms studied off antisecretory therapy. Patients with achalasia or absent contractility were excluded. CSI (averaged across 10 swallows) and BI-HRIM (from the resting landmark phase) were acquired from the distal impedance sensors (distal sensor and 5 cm above the lower esophageal sphincter). Acid exposure time (AET) and mean nocturnal baseline impedance (MNBI) were calculated. Associations between CSI, BI-HRIM, MNBI, and AET were evaluated using correlation (Pearson) and receiver operating characteristic (ROC) analysis. Presenting symptoms included heartburn (67%), regurgitation (12%), cough (12%), and chest pain (10%). CSI-distal and CSI-5 each correlated with BI-HRIM, AET, and distal MNBI. Associations with AET were numerically stronger for CSI-distal (r = -0.46) and BI-HRIM-distal (r = -0.44) than CSI-5 (r = -0.33), BI-HRIM-5 (r = -0.28), or distal MNBI (r < -0.36). When compared to AET <4%, patients with AET >6% had significantly lower CSI-distal and BI-HRIM-distal values but not CSI-5, BI-HRIM-5, or MNBI. ROC areas under the curve for AET >6% were numerically higher for CSI-distal (0.81) than BI-HRIM-distal (0.77), distal MNBI (0.68-0.75), CSI-5 (0.68), or BI-HRIM-5 (0.68). CSI from HRIM studies inversely correlates with pathologic AET and has potential to augment the evaluation of GERD.


Subject(s)
Esophageal pH Monitoring , Heartburn , Electric Impedance , Humans , Hydrogen-Ion Concentration , Manometry
2.
J Neurogastroenterol Motil ; 26(4): 455-462, 2020 09 30.
Article in English | MEDLINE | ID: mdl-32388941

ABSTRACT

Background/Aims: Esophageal baseline impedance (BI) can be extracted from pH-impedance tracings as mean nocturnal baseline impedance (MNBI), and from high-resolution impedance manometry (HRIM), but it is unknown if values are similar between acquisition methods across HRIM manufacturers. We aim to assess correlations between MNBI and BI from HRIM (BI-HRIM) from 2 HRIM manufacturers in the setting of physiologic acid exposure time (AET). Methods: HRIM and pH-impedance monitoring demonstrating physiologic AET (< 4%) off proton pump inhibitors were required. BI-HRIM was extracted as the average from 5 cm and 10 cm above the lower esophageal sphincter. Distal BI-HRIM (DBI-HRIM) was also extracted from the most distal channel (Medtronic studies). MNBI was extracted from 6 channels. Concordance between BI-HRIM across manufacturers with MNBI was analyzed. Results: Thirty-six patients met the inclusion criteria (59.6 ± 1.7 years; 22% female; body mass index 30.5 ± 0.7; AET 1.6 ± 0.2%). Although MNBI was similar at all channels (P ≥ 0.18), Diversatek BI-HRIM was lower than Medtronic BI-HRIM (P = 0.003). Overall, BI-HRIM correlated with MNBI at corresponding recording sites, 7 cm and 9 cm (P < 0.05), but not at other sites (P ≥ 0.19). Pearson's correlations > 0.5 were seen at MNBI at 7 cm for both systems, and at 9 cm for Medtronic. DBI-HRIM correlated with MNBI at 3 cm and 5 cm (P < 0.03), but not at other locations (P > 0.1). Conclusions: While numeric differences exist between manufacturers, BI-HRIM correlates with MNBI from corresponding channels in patients with physiologic AET. Comparison with AET elevation is needed to determine correlations between pathologic MNBI with BI-HRIM across manufacturers. The optimal HRIM channels from which BI values should be extracted also warrants further study.

SELECTION OF CITATIONS
SEARCH DETAIL
...