Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 92
Filter
1.
Conn Med ; 65(10): 597-604, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11702518

ABSTRACT

The establishment of "best clinical practices" founded upon evidence-based medicine has become an increasingly important priority. Frequently, management guidelines are derived from published research data and disseminated among practitioners to help optimize patient care. The ultimate clinical impact of these guidelines in the "real world," however, is often clouded by an incomplete assessment of patient outcomes throughout the continuum of health-care delivery models. In order to address this gap in clinical outcome assessment, we propose to establish the Connecticut Cardiovascular Consortium. The Consortium will consist of a collaborative partnership among all 31 Connecticut hospitals working in concert with Connecticut Office of Health Care Access (OHCA). The primary objective of the Consortium will be to assess, compare, and optimize clinical outcomes among Connecticut residents with cardiovascular disease. As an initial goal for the Consortium, we further propose to undertake a prospective, observational study of Connecticut residents who present with ST Segment Elevation Acute Myocardial Infarction (STEMI). Recent advances in pharmacologic and mechanical reperfusion for STEMI have resulted in a need to define the optimal use of these therapies in the community at large. The primary purpose of this study will be to determine the relative merits of different treatment patterns for STEMI with regard to the use of fibrinolytic therapy and percutaneous coronary intervention (PCI). Particular emphasis will be placed on assessing the relative benefits of urgent mechanical revascularization performed at the state's seven tertiary facilities with PCI capability compared to all other treatment modalities. Successful completion of this unique collaborative endeavor is expected to have significant impact on improved patient care and on current health-care policy for medical resource allocation. Moreover, continued collaboration of health-care providers within the Connecticut Cardiovascular Consortium infrastructure should serve as a useful mechanism for ongoing improvements in evidence-based cardiovascular medicine and clinical research in the state of Connecticut.


Subject(s)
Heart Diseases/therapy , Outcome Assessment, Health Care , Connecticut , Evidence-Based Medicine , Humans , Myocardial Infarction/therapy , Research
2.
Curr Opin Cardiol ; 16(6): 364-9, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11704707

ABSTRACT

The primary pathophysiologic mechanism underlying all non-ST-segment elevation acute coronary syndromes (NSTE ACS) is the formation of platelet-rich coronary thrombi in response to spontaneous or intervention-induced endothelial damage with exposure of subendothelial substrates. Antagonists of the glycoprotein (GP) IIb/IIIa receptor ameliorate this process by blocking the final common pathway for platelet aggregation. Based upon collective data in over 24,000 patients, clinical trials have demonstrated that treatment of NSTE ACS patients with GP IIb/IIIa agents results in an approximate 12% relative risk reduction in the incidence of death or myocardial infarction at 30 days. The magnitude of this clinical benefit is increased in patients who are troponin-positive and who are referred for early percutaneous intervention. Potential benefits of GP IIb/IIIa inhibitor use must be weighed against an increased risk of bleeding. Ongoing controversies exist concerning the relative efficacy of different GP IIb/IIIa antagonists, the accurate use of platelet function tests to define safe and efficacious drug dosing, the adjunctive use of additional anti-thrombotic agents, and the optimal timing of upstream therapy before diagnostic cardiac catheterization and revascularization.


Subject(s)
Heart Conduction System/drug effects , Myocardial Infarction/drug therapy , Myocardial Infarction/physiopathology , Platelet Aggregation Inhibitors/therapeutic use , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Tyrosine/analogs & derivatives , Acetates/therapeutic use , Clinical Trials as Topic , Electrocardiography , Eptifibatide , Heart Conduction System/physiopathology , Humans , Peptides/therapeutic use , Risk Factors , Time Factors , Tirofiban , Treatment Outcome , Tyrosine/therapeutic use
3.
Conn Med ; 65(9): 515-21, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11678056

ABSTRACT

BACKGROUND: Off-pump coronary artery bypass (OP-CAB) graft surgery is being used with increasing frequency. This study was designed to compare OP-CAB outcomes with conventional surgical revascularization using cardiopulmonary bypass (CPB) in patients with varying risk categories at a high-volume center. METHODS AND RESULTS: Between 1/1/1999 and 1/31/2001, bypass surgery was performed on 1,312 patients, including 348 OP-CAB cases and 964 CPB cases. Compared to CPB cases, OP-CAB patients were more likely to be female and had a lower incidence of three vessel coronary artery disease, prior percutaneous intervention, and prior bypass surgery. Postoperatively, OP-CAB patients had a lower incidence of renal failure and prolonged ventilatory support, as well as a lower composite endpoint of inhospital mortality, perioperative myocardial infarction, cerebrovascular accident, and/or renal failure. In addition, OP-CAB patients required fewer transfusions and had a shorter total length of hospital stay. In general, morbidity and mortality increased in both OP-CAB and CPB groups with increasing Parsonnet score. CONCLUSIONS: OP-CAB surgery is a safe and effective alternative to conventional coronary artery bypass graft (CABG) surgery, with a lower incidence of major in-hospital adverse clinical events and a decreased requirement for medical resources. Adverse OP-CAB outcomes correlate well with pre-operative Parsonnet Score.


Subject(s)
Cardiopulmonary Bypass , Coronary Artery Bypass , Aged , Case-Control Studies , Female , Humans , Incidence , Male , Postoperative Complications/epidemiology , Risk Assessment , Risk Factors , Treatment Outcome
5.
Am J Cardiol ; 86(3): 269-74, 2000 Aug 01.
Article in English | MEDLINE | ID: mdl-10922431

ABSTRACT

This study examined 650 consecutive patients who presented with an acute myocardial infarction and were treated with primary angioplasty within 12 hours of symptom onset between August 1995 and December 1998. Patients were placed into 4 treatment groups depending on the adjunctive therapy they received: group 1, percutaneous transluminal coronary angioplasty (PTCA) ("balloon PTCA alone"; n = 220); group 2, PTCA plus intracoronary stent placement ("stent"; n = 128); group 3, PTCA plus abciximab therapy ("abciximab"; n = 104); and group 4, PTCA plus intracoronary stent placement plus abciximab therapy ("stent/abciximab"; n = 198). The patients' clinical characteristics, severity of disease, and total ischemia time on presentation were similar. At baseline, abciximab and stent/abciximab groups had a higher incidence of thrombus on coronary angiography. Postprocedural quantitative coronary analysis showed a significantly larger minimum luminal diameter in the stent and stent/abciximab groups than PTCA alone. Overall, stents were most efficacious in reducing target vessel revascularization rate, whereas abciximab was associated with a higher postprocedural Thrombolysis In Myocardial Infarction-3 trial flow and less "no reflow." The best angiographic result was achieved in the stent/abciximab group. Similarly, the primary combined end point of death, myocardial infarction, and target vessel revascularization at 30 days was the lowest (6.1%) in the stent/abciximab group. The combination of abciximab and stenting in primary angioplasty for acute myocardial infarction is thus synergistic and is associated with improved angiographic and clinical results at 30-day follow-up.


Subject(s)
Angioplasty, Balloon, Coronary , Antibodies, Monoclonal/administration & dosage , Immunoglobulin Fab Fragments/administration & dosage , Myocardial Infarction/therapy , Platelet Aggregation Inhibitors/administration & dosage , Stents , Abciximab , Aged , Antibodies, Monoclonal/adverse effects , Combined Modality Therapy , Coronary Angiography , Female , Follow-Up Studies , Humans , Immunoglobulin Fab Fragments/adverse effects , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/mortality , Platelet Aggregation Inhibitors/adverse effects , Retrospective Studies , Survival Rate , Treatment Outcome
6.
Am J Cardiol ; 85(6): 675-9, 2000 Mar 15.
Article in English | MEDLINE | ID: mdl-12000039

ABSTRACT

Women presenting with acute myocardial infarction (AMI) have a higher mortality with conventional medical and thrombolytic therapy when compared with men. The outcome after primary percutaneous transluminal mechanical revascularization has not yet been fully investigated. This study was performed to compare the characteristics and the short- and medium-term outcomes of women and men with AMI treated with primary percutaneous revascularization. A total of 182 consecutive patients (62 women and 120 men) were included. Baseline clinical characteristics were similar except that women were older than men, presented more often in cardiogenic shock, and had smaller reference vessel diameters. Stents and abciximab were used equally, but abciximab was stopped more often in women before completion of the 12-hour infusion because of higher bleeding rates. Acute procedural success rates were similar (92% and 97%) but mortality was much higher in women, both at 30-day follow-up (100% vs 0.9%; p <0.05) and during a mean follow-up of 6.9 +/- 4.1 months (15% vs 4.4%; p <0.05). Women also experienced more unfavorable cardiovascular events (recurrent unstable angina or AMI, target vessel revascularization) than men. However, after control for baseline clinical differences in a multivariate analysis, gender was not an independent predictor of survival, whereas age, cardiogenic shock, and completion of a 12-hour abciximab infusion were.


Subject(s)
Angioplasty, Balloon, Coronary , Myocardial Infarction/mortality , Myocardial Infarction/therapy , Abciximab , Aged , Antibodies, Monoclonal/therapeutic use , Blood Transfusion/statistics & numerical data , Case-Control Studies , Female , Follow-Up Studies , Humans , Immunoglobulin Fab Fragments/therapeutic use , Male , Middle Aged , Multivariate Analysis , Platelet Aggregation Inhibitors/therapeutic use , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Risk Factors , Sex Factors , Shock, Cardiogenic/epidemiology , Time Factors , Treatment Outcome
7.
JAMA ; 282(18): 1731-6, 1999 Nov 10.
Article in English | MEDLINE | ID: mdl-10568645

ABSTRACT

CONTEXT: Vigorous physical exertion transiently increases the risk of acute myocardial infarction (MI), but little is known about the clinical characteristics of exertion-related MI. OBJECTIVE: To compare the clinical and angiographic characteristics of patients who had an exertion-related acute MI vs those who experienced an MI not related to exertion. DESIGN AND SETTING: Prospective observational cohort study of patients with an acute MI referred to a tertiary care hospital for primary angioplasty. PATIENTS: Of 1048 patients with acute MI, 640 (64 who experienced an exertion-related MI and 576 who did not) were selected for treatment with primary angioplasty and admitted between August 1995 and November 1998. MAIN OUTCOME MEASURES: Clinical characteristics of the patients, including their habitual physical activity (determined by the Framingham Physical Activity Index and the Lipid Research Clinic Physical Activity Questionnaire), angiographic findings during coronary angiography, and the relative risk (RR) of MI during exertion. RESULTS: Patients who experienced exertion-related MI were more frequently men (86% vs 68%), hyperlipidemic (62% vs 40%), and smokers (59% vs 37%), were more likely to present with ventricular fibrillation (20% vs 11%), Killip classification III or IV heart failure (44% vs 22%), single-vessel disease (50% vs 28%), and a large thrombus in the infarct artery (64% vs 35%) and were more likely to be classified as having very low or low activity (84% vs 66%). The RR of experiencing an MI during exertion was 10.1 times greater than the risk at other times (95% confidence interval [CI], 1.6-65.6), with the highest risk among patients classified as very low active (RR, 30.5; 95% CI, 4.4-209.9) and low active (RR, 20.9; 95% CI, 3.1-142.1). CONCLUSION: These results show that exertion-related MIs occur in habitually inactive people with multiple cardiac risk factors. These individuals may benefit from modest exercise training and aggressive risk-factor modification before they perform vigorous physical activity.


Subject(s)
Myocardial Infarction/etiology , Myocardial Infarction/physiopathology , Physical Exertion/physiology , Cardiac Catheterization , Coronary Angiography , Female , Humans , Logistic Models , Male , Myocardial Infarction/diagnostic imaging , Prospective Studies , Risk
8.
J Am Coll Cardiol ; 32(7): 1996-2002, 1998 Dec.
Article in English | MEDLINE | ID: mdl-9857884

ABSTRACT

OBJECTIVES: The purpose of this study was to compare the outcome of primary percutaneous transluminal coronary angioplasty for acute myocardial infarction (MI) when performed with or without the platelet glycoprotein IIb/IIIa antibody, abciximab. BACKGROUND: Abciximab improves the outcome of angioplasty but the effect of abciximab in primary angioplasty has not been investigated. METHODS: Data were collected from a computerized database. Follow-up was by telephone or review of outpatient or hospital readmission records. RESULTS: A total of 182 consecutive patients were included; 103 received abciximab and 79 did not. The procedural success rate was 95% in the two groups. At 30-day follow-up, the composite event rate of unstable angina, reinfarction, target vessel revascularization and death from all causes was 13.5% in the group of patients who did not receive abciximab, 4% (p < 0.05) in the abciximab group and 2.4% (p < 0.05) in the subgroup of patients (n = 87) who completed the 12-h abciximab infusion. At the end of follow-up (mean 7+/-4 months), the composite event rate was 32.4%, 17% (p < 0.05) and 13.1% (p < 0.01) in these three categories respectively. Abciximab bolus followed by a 12-h infusion was an independent predictor of event-free survival, in a Cox proportional hazards model (relative risk 0.49; 95% confidence interval 0.24 to 0.99; p < 0.05). CONCLUSIONS: Abciximab given at the time of primary angioplasty may improve the short- and medium-term outcome of patients with acute MI, especially when a 12-h infusion is completed.


Subject(s)
Angioplasty, Balloon, Coronary , Antibodies, Monoclonal/therapeutic use , Immunoglobulin Fab Fragments/therapeutic use , Myocardial Infarction/therapy , Platelet Aggregation Inhibitors/therapeutic use , Abciximab , Aged , Female , Humans , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/mortality , Proportional Hazards Models , Survival Analysis , Treatment Outcome
9.
Orig Life Evol Biosph ; 28(1): 27-45, 1998 Feb.
Article in English | MEDLINE | ID: mdl-11536854

ABSTRACT

Molecular orbital spectral predictions suggest that 2,5,7,10,12,15,17,20-octaaza-21H, 23H-porphine has a visible spectral range closely matching that of chlorophyll-a. Since the octaazaporphine is, in its core, a simple derivative of an (HCN)12 oligomer, this fact, together with its spectral properties, would suggest that it occupies a high rank as a primordial porphinic solar energy transducer for photochemistry essential to life's formation. The demonstration that the mass 324 hexahydrooctaazaporphine is formed in protic media by the cyclotetramerization of imidazol-4-aminohydroxonium ion or the derived nitrenium ion, and that a mass 318 species consonant with that of the Huckel aromatic octaazaporphine is observed in the course of these studies, strongly supports the proposed octaazaporphine synthesis in a prebiotic hydrocyanic acid milieu.


Subject(s)
Hydrogen Cyanide/chemistry , Hydrogen Cyanide/radiation effects , Nitroimidazoles/chemical synthesis , Origin of Life , Porphyrins/chemical synthesis , Sunlight , Chlorophyll/chemistry , Chlorophyll A , Ions , Nitrogen Compounds/chemistry , Photochemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization
10.
Am J Cardiol ; 80(11): 1476-8, 1997 Dec 01.
Article in English | MEDLINE | ID: mdl-9399726

ABSTRACT

C-reactive protein (CRP) levels increased more than sixfold above baseline when measured 48 hours after elective percutaneous transluminal coronary angioplasty (PTCA) in patients without underlying inflammatory conditions and did not change significantly in controls undergoing coronary angiography. Only 3 of the 42 PTCA patients had clinical restenosis and underwent target vessel revascularization during the 6-month follow-up, but 2 of the 3 had very high CRP levels 48 hours after the procedure.


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , C-Reactive Protein/metabolism , Coronary Disease/immunology , Lymphocyte Activation , Neutrophil Activation , Platelet Activation , Biomarkers , Cell Adhesion , Coronary Angiography , Coronary Disease/blood , Coronary Disease/therapy , Follow-Up Studies , Humans , Middle Aged , Recurrence
11.
Cathet Cardiovasc Diagn ; 42(3): 348-55, 1997 Nov.
Article in English | MEDLINE | ID: mdl-9367120

ABSTRACT

Nineteen pigs were studied in order to assess the effect of low grade, radiofrequency-powered, thermal balloon angioplasty on the vasoconstrictor response of peripheral arteries. A mechanical stimulus was used to induce vasospasm. Thermal angioplasty reduced the extent of inducible vasospasm from 79% to 6% compared to nonthermal control inflations, which reduced the vasoconstrictor response from 75% to 60% (P < 0.001). Histologic studies demonstrated that the extent of myocyte necrosis was significantly greater in the thermally treated arteries than in the control vessels (P < 0.01). Thermal balloon angioplasty at 60 degrees C significantly attenuates peripheral arterial vasospasm induced by mechanical trauma in the porcine model. This paralytic effect may be related to the loss of myocytes secondary to thermal necrosis.


Subject(s)
Angioplasty, Balloon , Coronary Vasospasm/physiopathology , Hot Temperature , Vasoconstriction , Animals , Coronary Angiography , Coronary Vasospasm/pathology , Coronary Vessels/pathology , Female , Male , Myocardium/cytology , Myocardium/pathology , Necrosis , Swine
12.
Cathet Cardiovasc Diagn ; 41(3): 232-40, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9213020

ABSTRACT

Intraluminal delivery of antisense oligonucleotides to c-myb was assessed following balloon angioplasty in swine peripheral arteries. Successful delivery and intramural persistence of oligonucleotide for over 24 h were demonstrated following angioplasty with hydrogel balloons coated with 32P-labeled antisense. Delivery of fluorescein-labeled antisense demonstrated further localization within the arterial media and intracellularly. Preliminary in vitro studies demonstrated the feasibility of inhibition of porcine lymphocyte proliferation using the murine antisense to c-myb. Twelve iliac or carotid arteries underwent angioplasty with antisense-coated balloons, while the contralateral vessels underwent angioplasty with the same-sized balloons coated with the complementary sense strand. Six to seven days later, dilated arterial segments were surgically isolated. In 10 of 12 vessel pairs, antisense-treated vessels demonstrated less cellular proliferation than did contralateral sense-treated vessels, as assessed by quantitative immunohistochemical staining of proliferating cell nuclear antigen, and smooth muscle cell proliferation was reduced 18% in antisense-treated vessels compared to the contralateral sense-treated vessels (PCNA-positive nuclear area: 7.7 +/- 4.9% vs. 9.3 +/- 5.2%, P < 0.04)-intraluminal delivery of antisense oligonucleotides to c-myb is feasible with a catheter-based system and may reduce smooth muscle cell proliferation following arterial injury.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Disease/drug therapy , Drug Delivery Systems/instrumentation , Oligonucleotides, Antisense/administration & dosage , Proto-Oncogene Proteins/antagonists & inhibitors , Trans-Activators/antagonists & inhibitors , Animals , Autoradiography , Cell Division/drug effects , Coronary Disease/pathology , Coronary Vessels/drug effects , Coronary Vessels/pathology , Feasibility Studies , Female , Lymphocyte Activation/drug effects , Mice , Microscopy, Fluorescence , Muscle, Smooth, Vascular/drug effects , Muscle, Smooth, Vascular/pathology , Oligonucleotides, Antisense/pharmacokinetics , Proliferating Cell Nuclear Antigen/metabolism , Proto-Oncogene Proteins/metabolism , Proto-Oncogene Proteins c-myb , Swine , Trans-Activators/metabolism
13.
Cathet Cardiovasc Diagn ; 41(3): 254-60, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9213023

ABSTRACT

The Channel balloon is a new local drug-delivery catheter that has the dual capability of high-pressure lesion dilation and low-pressure drug infusion. The purpose of this study was to assess the safety and efficacy of this device in the local delivery of urokinase in the porcine model. Three in vivo protocols were performed in 57 anesthetized swine to assess the safety of Channel balloon use in the coronary vasculature, the pharmacokinetics of local urokinase delivery, and the ability of the catheter to lyse intraluminal thrombus. First, safety studies were performed in 18 coronary vessels in 13 pigs to compare angiographic and histologic changes following use of the Channel balloon with conventional balloon angioplasty. Second, intramural deposition of 123I-labeled urokinase was measured in 24 coronary arteries in 20 pigs to assess the efficiency and technical determinants of urokinase delivery and the time course of intramural drug retention. Finally, an in vivo thrombus model was used in 24 pigs to compare the thrombolytic capacity of local urokinase delivery with the Channel balloon in comparison with conventional urokinase infusion techniques. All balloon inflations and drug infusions with the Channel balloon were well tolerated in all animals without adverse angiographic, hemodynamic, or electrical sequelae. Comparative histologic studies with the Channel balloon demonstrated no additional vessel trauma beyond that seen with conventional balloon angioplasty. Between 0.09 and 0.35% of infused urokinase was intramurally deposited, with intracoronary persistence for at least 5 h. Drug infusion pressure did not significantly affect drug deposition, although larger amounts of urokinase were deposited with larger balloon:artery ratios and higher urokinase concentrations. In comparison to conventional systemic and guiding catheter infusions, local delivery of urokinase with the Channel balloon resulted in higher levels of clot dissolution. These studies have demonstrated safe intracoronary use of the Channel balloon in the porcine model. Local infusion of urokinase with this device results in significant intramural drug deposition that persists for at least 5 h. In comparison with conventional thrombolytic techniques, local urokinase delivery with the Channel balloon may result in enhanced intravascular thrombolysis.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cell Division/drug effects , Drug Delivery Systems/instrumentation , Fibrinolytic Agents/administration & dosage , Muscle, Smooth, Vascular/drug effects , Thrombolytic Therapy/instrumentation , Urokinase-Type Plasminogen Activator/administration & dosage , Animals , Equipment Design , Equipment Safety , Feasibility Studies , Female , Fibrinolytic Agents/pharmacokinetics , Iliac Artery/drug effects , Iliac Artery/injuries , Iliac Artery/pathology , Male , Muscle, Smooth, Vascular/injuries , Muscle, Smooth, Vascular/pathology , Proliferating Cell Nuclear Antigen/metabolism , Swine , Treatment Outcome , Tunica Media/drug effects , Tunica Media/injuries , Tunica Media/pathology , Urokinase-Type Plasminogen Activator/pharmacokinetics
14.
Cathet Cardiovasc Diagn ; 41(3): 246-53, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9213022

ABSTRACT

Conventional balloon angioplasty in the presence of intracoronary thrombus is associated with an elevated risk for acute myocardial infarction, emergency bypass surgery, and death. The purpose of this study was to assess the safety and efficacy of a new technique to treat thrombus-containing stenoses consisting of the local delivery of urokinase directly to the site of intraluminal clot with hydrogel-coated balloons. Ninety-five patients with angiographically apparent intracoronary thrombus were treated with urokinase-coated hydrogel balloons either prior to (n = 74) or following (n = 21) conventional balloon angioplasty. Clinical diagnoses for the study group included acute myocardial infarction in 50 patients, postinfarction angina in 23 patients, and unstable angina in 22 patients. All hydrogel balloons were initially coated with urokinase by immersing the inflated balloon in a concentrated Abbokinase solution (50,000 units/ml) for 60 s. All patients were subsequently treated with drug-coated balloons using a balloon:artery ratio of 1:1, a mean of 2.2 +/- 1.2 inflations, and a mean total inflation time of 7.5 +/- 4.9 min. Use of urokinase-coated balloons resulted in angiographic disappearance of intracoronary thrombus in 78 patients, improvement in 14, and no change in the remaining 3 patients. Following hydrogel balloon use for the entire 95 patients, TIMI flow increased from 1.4 +/- 1.2 to 2.9 +/- 0.4, minimal lumen diameter increased from 0.4 +/- 0.4 to 2.0 +/- 0.6 mm, and thrombus score decreased from 2.0 +/- 0.9 to 0.2 +/- 0.6 (all P < 0.01). Procedural and early in-hospital complications were noted in 7 of the 95 patients (7.4%) and included abrupt closure in 3 patients, distal embolization in 1 patient, no reflow in 1 patient, sidebranch occlusion in 1 patient, and late closure in 1 patient. Two of the 3 patients with abrupt closure and the single patient with late closure required intracoronary stenting to maintain vessel patency. Two of these 7 patients sustained small myocardial infarctions, although no patient required emergency bypass surgery or experienced a procedural death. Late clinical follow-up (mean = 8.3 +/- 6.6 months; range = 2 wk to 29 mo) demonstrated adverse recurrent events in 29 of the 95 patients (30.5%), including death (n = 5), myocardial infarction (n = 2), and recurrence of angina (n = 22). The results of this study suggest that intracoronary thrombolysis can be safely and rapidly achieved by using limited quantities of urokinase delivered directly to the site of intraluminal clot with hydrogel balloons. Use of this technique may result in improved acute outcomes in comparison with conventional techniques currently being used to treat thrombus-containing stenoses.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Thrombosis/drug therapy , Drug Delivery Systems/instrumentation , Fibrinolytic Agents/administration & dosage , Polyethylene Glycols , Thrombolytic Therapy/instrumentation , Urokinase-Type Plasminogen Activator/administration & dosage , Adult , Aged , Angina Pectoris/diagnostic imaging , Angina Pectoris/drug therapy , Angina Pectoris/mortality , Angina, Unstable/diagnostic imaging , Angina, Unstable/drug therapy , Angina, Unstable/mortality , Coronary Angiography/drug effects , Coronary Circulation/drug effects , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/mortality , Equipment Design , Female , Humans , Hydrogel, Polyethylene Glycol Dimethacrylate , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/drug therapy , Myocardial Infarction/mortality , Recurrence , Surface Properties , Survival Rate
15.
Cathet Cardiovasc Diagn ; 41(3): 261-7, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9213024

ABSTRACT

Percutaneous treatment of thrombotic stenoses or total occlusions in aged saphenous vein bypass grafts is associated with a significant incidence of complications primarily related to distal embolization. The purpose of this study was to assess the efficacy of local urokinase delivery with the Dispatch catheter prior to balloon angioplasty and/or intragraft stent placement as a new technique of vein graft revascularization. Local urokinase delivery with the Dispatch catheter was performed in 15 saphenous vein grafts (mean age = 11.7 +/- 2.5 yr) in 13 patients with unstable or postinfarction angina. The target lesion was a total occlusion in 5 of the procedures and a severe vein graft stenosis in the remaining 10. In all cases, urokinase was administered directly to the site of the stenosis/occlusion via the Dispatch catheter at 0.5 cc/min and at a concentration of 30,000 units/cc. The mean urokinase infusion time for the 15 procedures was 33 +/- 10 min (range = 10-60 min) and the mean urokinase dose was 495,000 +/- 158,000 units (range = 150,000-900,000 units). Following Dispatch therapy, mean minimal lumen diameter increased from 0.34 +/- 0.32 to 1.81 +/- 0.78 mm (P < 0.01), mean TIMI flow increased from 1.9 +/- 1.4 to 2.8 +/- 0.8 (P < 0.06), and mean thrombus score was reduced from 2.3 +/- 0.6 to 0.3 +/- 0.8 (P < 0.01). Mild no reflow was noted in two cases, although no patient demonstrated angiographic evidence of gross distal embolization. One of the patients with no reflow also demonstrated a small increase in cardiac enzymes. Subsequent balloon angioplasty/stent placement was successful in 14 of the 15 procedures (93% success rate). This preliminary report suggests that pretreatment of thrombotic saphenous vein graft stenoses with local urokinase delivery via the Dispatch catheter may decrease intragraft thrombus and possibly decrease the incidence of vascular complications associated with percutaneous intervention. This technique may allow for recanalization of totally occluded vein grafts with large clot burdens by using significantly less urokinase and shorter drug administration times than conventional infusion protocols.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Bypass , Coronary Disease/surgery , Drug Delivery Systems/instrumentation , Fibrinolytic Agents/administration & dosage , Graft Occlusion, Vascular/drug therapy , Thrombolytic Therapy/instrumentation , Urokinase-Type Plasminogen Activator/administration & dosage , Veins/transplantation , Adult , Aged , Coronary Angiography , Coronary Disease/diagnostic imaging , Equipment Design , Female , Graft Occlusion, Vascular/diagnostic imaging , Humans , Male , Middle Aged , Recurrence , Retreatment , Stents , Treatment Outcome
16.
Cathet Cardiovasc Diagn ; 41(3): 275-86, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9213026

ABSTRACT

The purpose of this study was to assess the efficacy of local heparin delivery to balloon angioplasty sites in an in vivo porcine model by using a newly designed angiotherapy catheter that allows for prolonged drug infusion while maintaining distal arterial perfusion. Protocols were designed to assess the safety of intracoronary drug delivery, the effect of infusion time and drug concentration on intramural heparin deposition, the distribution of heparin within the arterial wall, the histologic effects of local heparin delivery, the wash-out of intramurally deposited heparin, and the effect of heparin delivery on early platelet deposition following balloon injury in peripheral and coronary vessels. Local intracoronary delivery of heparin was well tolerated in all animals. Between 0.04 and 0.08% of infused heparin was intramurally deposited at the time of drug delivery, with longer infusion durations and higher concentrations of heparin resulting in greater intramural deposition. Autoradiography demonstrated homogenous distribution of heparin throughout the intima, media, and adventitia, with localization in the nuclei, cytoplasm, and extracellular space. Histologic analysis demonstrated no additional vessel trauma from local drug delivery beyond that seen with conventional angioplasty. Wash-out studies demonstrated a biexponential disappearance of intramurally deposited drug, with rapid release of heparin over the first 60 min and persistence of small amounts of drug for at least 7 d. Locally delivered heparin significantly attenuated the deposition of platelets in peripheral vessels, although a similar decrease in platelet deposition in the coronary arteries was not statistically significant. Local delivery of heparin directly to coronary angioplasty sites is possible with the use of a new angiotherapy catheter. Wash-out of heparin from the arterial wall is initially rapid, although drug is detectable for up to 1 wk following delivery. In porcine peripheral arteries, use of this technique significantly decreases early platelet deposition following balloon injury.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Anticoagulants/administration & dosage , Coronary Vessels/drug effects , Drug Delivery Systems/instrumentation , Heparin/administration & dosage , Muscle, Smooth, Vascular/drug effects , Platelet Aggregation/drug effects , Animals , Anticoagulants/pharmacokinetics , Autoradiography , Coronary Vessels/pathology , Dose-Response Relationship, Drug , Equipment Design , Heparin/pharmacokinetics , Muscle, Smooth, Vascular/pathology , Swine , Treatment Outcome
17.
Cathet Cardiovasc Diagn ; 41(3): 293-302, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9213028

ABSTRACT

Local delivery of urokinase directly to the site of intraluminal clot using catheter-based technology has recently been introduced as a new technique to treat intracoronary thrombus and thrombus-containing stenoses. The purpose of this study was to compare the efficacy of urokinase therapy administered by local drug-delivery catheters with conventional urokinase-infusion techniques in dissolving intraluminal clot and intramurally depositing drug at the site of arterial injury in an in vivo porcine model. Five techniques of urokinase administration were studied in 65 pigs, including intravenous systemic bolus (1,000,000 units), guiding catheter infusion (500,000 units), local intraluminal infusion with a Roubin catheter (150,000 units), local infusion by the Dispatch catheter (150,000 units), and local delivery by the hydrogel-coated balloon (700 units). All five techniques were initially compared with respect to the quantity of intraluminal lysis of 123I-fibrinogen-labeled thrombus in an in vivo thrombus model. Conventional balloon angioplasty was also assessed in this model as a nonpharmacologic, mechanical control. In addition, all five techniques were compared with respect to the quantity and efficiency of intramural urokinase deposition at coronary angioplasty sites. In the in vivo thrombolysis experiments, the quantity of artificial clot lysis measured 6.8% for systemic therapy, 20.8% for guiding catheter infusion, 25.2% for Roubin catheter infusion, 62.8% for Dispatch catheter infusion, 98.8% for hydrogel balloon delivery, and 53.6% for conventional balloon angioplasty. Both the Dispatch catheter and the hydrogel balloon resulted in more clot lysis than the systemic, guiding catheter, or Roubin catheter approaches (P < 0.05). In comparison with conventional balloon angioplasty, only the hydrogel balloon resulted in higher levels of thrombus dissolution (P < 0.05). In the intramural deposition studies, the efficiency of urokinase delivery was 0.0004% for systemic therapy, 0.004% for guiding catheter infusion, 0.004% for Roubin catheter infusion, 0.08% for Dispatch catheter infusion, and 1.8% for hydrogel balloon delivery. The Dispatch catheter resulted in higher intramural drug levels than did all other techniques (P < 0.05), whereas the efficiency of urokinase deposition was higher with the hydrogel balloon than with all other approaches (P < 0.05). In the porcine model, it is subsequently concluded that local delivery of urokinase by catheter-based techniques can result in more complete lysis of intraluminal thrombus by using similar or lower doses of drug than by using conventional urokinase infusion techniques. Mechanical deformation of thrombus, possibly to increase the surface area available for thrombolysis and to physically disrupt clot, may be an important component of the mechanism of site-specific thrombolysis, particularly with the hydrogel balloon. Local delivery techniques also deposit significant quantities of urokinase at balloon angioplasty sites, creating an intramural reservoir of drug that may result in prolonged local thrombolysis.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Thrombosis/drug therapy , Drug Delivery Systems/instrumentation , Fibrinolytic Agents/administration & dosage , Thrombolytic Therapy/instrumentation , Urokinase-Type Plasminogen Activator/administration & dosage , Animals , Dose-Response Relationship, Drug , Female , Fibrinolytic Agents/pharmacokinetics , Male , Microscopy, Electron , Swine , Treatment Outcome , Urokinase-Type Plasminogen Activator/pharmacokinetics
18.
Cathet Cardiovasc Diagn ; 41(3): 315-23, 1997 Jul.
Article in English | MEDLINE | ID: mdl-9213031

ABSTRACT

Drug delivery by iontophoresis involves the application of an electric field to move selectively charged drug molecules across biological membranes. The purpose of this study was to assess the efficacy of intravascular iontophoresis in the local delivery of heparin to balloon angioplasty sites by using a recently designed iontophoretic catheter. In vivo heparin iontophoresis was assessed in 33 rats and 21 pigs in four protocols designed to measure the technical determinants of intramural drug deposition, the pharmacokinetics and localization of coronary delivery, and the effect of this technique on platelet deposition following balloon injury. First, iontophoresis of 3H-heparin into the aorta of 33 rats was performed to determine the effects of iontophoretic current, iontophoretic membrane balloon initiation pressure, iontophoresis time, and heparin concentration on intramural drug deposition. Second, iontophoresis of 3H-heparin was performed in 16 porcine coronary arteries to quantitate immediate drug delivery and subsequent wash-out over 24 h. Third, iontophoresis of fluorescent heparin was performed in 8 porcine coronary arteries to define intramural localization of locally delivered drug. Fourth, 111In-labeled platelet deposition was measured 1 h following balloon angioplasty and local iontophoretic heparin delivery in 16 porcine carotid and iliac vessels. Contralateral control vessels that were dilated with the same size balloon and treated with iontophoresis of saline served as controls. Rat aortic studies demonstrated that iontophoresis resulted in 13 times more intramural heparin deposition than passive delivery (passive: 0.3 +/- 0.4 microgram, iontophoresis: 4.6 +/- 1.6 micrograms, P < 0.0004). Iontophoretic membrane balloon inflation pressure had no significant effect on intramural drug deposition, but longer iontophoresis times and higher heparin concentrations resulted in higher levels of intramural heparin (P < 0.05). Porcine coronary studies demonstrated successful intramural deposition of heparin in all arteries without adverse electrical or hemodynamic sequelae, with persistence of the drug for at least 24 h. Localization studies demonstrated immediate deposition of fluorescent heparin in the intima and internal elastic lamina, with subsequent rapid diffusion of the drug into the media. Porcine platelet studies demonstrated that heparin iontophoresis decreased platelet deposition following balloon injury by approximately 66% compared with saline-treated control vessels (heparin-treated: 1.46 +/- 2.51 x 10(8), control: 4.27 +/- 7.02 x 10(8), P = 0.001). This study has demonstrated that local intramural heparin delivery is feasible with an intravascular iontophoretic catheter. Following intracoronary heparin iontophoresis in the porcine model, intramural drug is detected for at least 24 h. Local delivery of heparin with this technique significantly decreases early platelet deposition following balloon injury in peripheral porcine arteries.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon/instrumentation , Anticoagulants/administration & dosage , Drug Delivery Systems/instrumentation , Heparin/administration & dosage , Iontophoresis/instrumentation , Muscle, Smooth, Vascular/drug effects , Animals , Anticoagulants/pharmacokinetics , Aorta/drug effects , Aorta/injuries , Aorta/pathology , Coronary Vessels/drug effects , Coronary Vessels/injuries , Coronary Vessels/pathology , Dose-Response Relationship, Drug , Elastic Tissue/drug effects , Elastic Tissue/injuries , Elastic Tissue/pathology , Equipment Design , Heparin/pharmacokinetics , Male , Muscle, Smooth, Vascular/injuries , Muscle, Smooth, Vascular/pathology , Platelet Aggregation/drug effects , Rats , Rats, Sprague-Dawley , Swine , Tunica Intima/drug effects , Tunica Intima/injuries , Tunica Intima/pathology , Tunica Media/drug effects , Tunica Media/injuries , Tunica Media/pathology
19.
Clin Cardiol ; 19(10): 782-6, 1996 Oct.
Article in English | MEDLINE | ID: mdl-8896910

ABSTRACT

BACKGROUND: Recent studies have suggested that immunoassay of cardiac troponin T (cTnT) provides a more sensitive measurement of myocardial necrosis than creatine kinase MB (CK-MB) mass concentration. HYPOTHESIS: The purpose of this study was to compare the release of cTnT and CK-MB isoenzyme in patients undergoing percutaneous coronary angioplasty, and to investigate the clinical, procedural, and angiographic correlates of abnormal elevations of both of these markers. METHODS: Total creatine kinase (total CK), CK-MB, and cTnT levels were measured immediately before and 12 h following intervention in 110 patients, including 100 consecutive patients undergoing coronary angioplasty and 10 control patients undergoing diagnostic cardiac catheterization. All patients had normal levels of all three markers at baseline. A postintervention total CK level > 225 U/l, an increase in CK-MB > 5.0 ng/ml, and/or an increase in cTnT > 0.04 ng/ml were considered indicative of myocardial injury. RESULTS: Coronary angioplasty was successfully performed in all 100 patients without emergency bypass surgery or death, although six patients required emergent placement of an intracoronary stent for threatened closure. Eight patients demonstrated an abnormal increase in total CK, including six who were undergoing primary angioplasty for an acute myocardial infarction. One of these patients sustained a Q-wave infarction. Post angioplasty, 18 patients had elevations of both CK-MB and cTnT, 23 had elevations of only cTnT, and the remaining 59 patients had elevations of neither. All patients with CK-MB elevation also had cTnT elevation. Neither serologic marker increased in the diagnostic catheterization control patients. In comparison with patients without postintervention cTnT rise, patients with abnormal cTnT levels had a higher incidence of complex lesion morphology (p < 0.01) and intracoronary thrombus (p < or = 0.0001) prior to coronary angioplasty, and a higher incidence of coronary dissection (p < or = 0.01), abrupt closure (p < or = 0.05), and side-branch occlusion (p < or = 0.01) during angioplasty. In patients with elevation of both cTnT and CK-MB, postintervention CK-MB levels were 12-fold higher and cTnT levels were 21-fold higher than in patients with isolated elevation of only cTnT (p < 0.01). CONCLUSIONS: These data indicate that > 40% of patients undergoing coronary angioplasty have evidence of minor degrees of myocardial damage, as evidenced by cTnT release. High-risk coronary lesions and both minor and major complications of angioplasty are associated with cTnT release. cTnT appears to be a more sensitive marker of myocardial injury than CK-MB under these circumstances. In comparison with isolated cTnT rise, elevation of both CK-MB and cTnT may be indicative of greater levels of myocardial injury.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Disease/enzymology , Coronary Disease/therapy , Creatine Kinase/metabolism , Myocardial Ischemia/physiopathology , Troponin/metabolism , Aged , Biomarkers/analysis , Coronary Angiography , Coronary Disease/diagnostic imaging , Creatine Kinase/analysis , Female , Humans , Isoenzymes , Male , Middle Aged , Prognosis , Radioimmunoassay , Sensitivity and Specificity , Troponin/analysis , Troponin T
20.
Cathet Cardiovasc Diagn ; 37(4): 453-4, 1996 Apr.
Article in English | MEDLINE | ID: mdl-8721704

ABSTRACT

Maintaining the position of a guidewire across coronary artery lesions during angioplasty is important to permit rapid and reliable access. This article describes a technique which enables a guide catheter to be replaced while maintaining coronary guidewire position by using an additional, larger guidewire for support to prevent dislodgment of the coronary guidewire.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheterization/instrumentation , Coronary Disease/therapy , Coronary Angiography/instrumentation , Equipment Design , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...