Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 130
Filter
1.
Phys Rev Lett ; 132(23): 235102, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38905687

ABSTRACT

Multimachine empirical scaling predicts an extremely narrow heat exhaust layer in future high magnetic field tokamaks, producing high power densities that require mitigation. In the experiments presented, the width of this exhaust layer is nearly doubled using actuators to increase turbulent transport in the plasma edge. This is achieved in low collisionality, high confinement edge pedestals with their gradients limited by turbulent transport instead of large-scale, coherent instabilities. The exhaust heat flux profile width and divertor leg diffusive spreading both double as a high frequency band of turbulent fluctuations propagating in the electron diamagnetic direction doubles in amplitude. The results are quantitatively reproduced in electromagnetic XGC particle-in-cell simulations which show the heat flux carried by electrons emerges to broaden the heat flux profile, directly supported by Langmuir probe measurements.

2.
Rev Sci Instrum ; 94(3): 033504, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-37012775

ABSTRACT

A novel spectroscopy diagnostic for measuring internal magnetic fields in high temperature magnetized plasmas has been developed. It involves spectrally resolving the Balmer-α (656 nm) neutral beam radiation split by the motional Stark effect with a spatial heterodyne spectrometer (SHS). The unique combination of high optical throughput (3.7 mm2sr) and spectral resolution (δλ ∼ 0.1 nm) allows these measurements to be made with time resolution ≪1 ms. The high throughput is effectively utilized by incorporating a novel geometric Doppler broadening compensation technique in the spectrometer. The technique significantly reduces the spectral resolution penalty inherent to using large area, high-throughput optics while still collecting the large photon flux provided by such optics. In this work, fluxes of order 1010 s-1 support the measurement of deviations of <5 mT (ΔλStark ∼ 10-4 nm) in the local magnetic field with 50 µs time resolution. Example high time resolution measurements of the pedestal magnetic field throughout the ELM cycle of a DIII-D tokamak plasma are presented. Local magnetic field measurements give access to the dynamics of the edge current density, which is essential to understanding stability limits, edge localized mode generation and suppression, and predicting performance of H-mode tokamaks.

3.
Philos Trans A Math Phys Eng Sci ; 381(2242): 20210240, 2023 Feb 20.
Article in English | MEDLINE | ID: mdl-36587824

ABSTRACT

The L-H transition power threshold (PLH) in favourable magnetic geometry (ion ∇B drift pointing towards X-point) is much lower than in the unfavourable magnetic geometry (ion ∇B drift pointing away from X-point) on multiple tokamaks. In a systematic experiment on DIII-D, the ion ∇B drift direction was changed continuously from the unfavourable to favourable configuration during plasma discharges. During such process, the input neutral beam power was kept constant at a value that was above PLH for favourable configuration, but lower than PLH for unfavourable configuration. Toroidal field and plasma current were also kept constant and there was little change in the edge electron density ne and electron temperature Te profiles. The density fluctuation amplitude was reduced approaching the transition, while a large increase of turbulence Reynolds stress and flow shear were simultaneously observed. The turbulence decorrelation rate was found to increase as the ion ∇B drift direction was moving towards the favourable configuration, but the flow shear also increased and exceeded the turbulence decorrelation rate. These measurements demonstrate an important correlation between turbulence and turbulence-driven flow and a lowering of PLH, provide insights into the underlyingphysics behind the hidden parameters and inform a more complete physics-based model of the L-H transition power threshold. This article is part of a discussion meeting issue 'H-mode transition and pedestal studies in fusion plasmas'.

4.
Rev Sci Instrum ; 93(11): 113546, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36461451

ABSTRACT

A novel Motional Stark Effect spectroscopy system has been designed for application at the DIII-D tokamak. The system is optimized for studies of the poloidal and toroidal magnetic field in the plasma pedestal region with frame rates of up to 10 kHz. Light from an existing high-photon-throughput collection lens is analyzed using four single-channel f/2.8 Czerny-Turner spectrometers that use custom-made lens systems instead of mirrors. Each spectrometer has two separate outgoing legs and is operated in a positive grating order, which allows for simultaneous observations of D-alpha and D-beta spectra. Forward modeling using the code FIDASIM shows a radial resolution of the system close to 0.6 cm and sufficiently good spectral resolution when masking the high throughput light collection lens in the horizontal direction to avoid overly strong Doppler broadening of beam emission lines. Moreover, a detailed sensitivity study considering realistic levels of readout and photon noise shows that the poloidal and toroidal magnetic field strengths can be inferred with an uncertainty of less than 1%, which will allow the inference of changes of the plasma current during transient events.

5.
Rev Sci Instrum ; 93(11): 113503, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36461537

ABSTRACT

A new high radial resolution 2D multichannel Charge eXchange Imaging (CXI) diagnostic is under development for deployment at DIII-D. The diagnostic system will measure low-to-intermediate radial wavenumber carbon density fluctuations by observing the n = 8 - 7 (λ = 529.06 nm) C-VI emission line, resulting from charge exchange collisions between heating neutral beam atoms and the intrinsic carbon ion density. The new CXI diagnostic will provide measurements with ΔR ∼ 0.4 cm to access higher kr instabilities (kr < 8 cm-1) predicted to arise in the steep-gradient region of the H-mode pedestal. The CXI system will feature 60 fiber bundles in a 12 × 5 arrangement, with each bundle consisting of four 1 mm fibers. A custom optical system has been designed to filter and image incoming signals onto an 8 × 8 avalanche photodiode array. Additionally, a novel electronics suite has been designed and commissioned to amplify and digitize the relatively low-intensity carbon signal at a 2 MHz bandwidth. Forward modeling results of the active C-VI emission suggest sufficient signal to noise ratios to resolve turbulent fluctuations. Prototype measurements demonstrate the ability to perform high frequency pedestal measurements.

6.
Rev Sci Instrum ; 93(10): 103535, 2022 Oct 01.
Article in English | MEDLINE | ID: mdl-36319390

ABSTRACT

Two newly developed, eight-channel, integrated Beam Emission Spectroscopy (BES) detectors have been installed at Huan-Liuqi-2A tokamak, which extends the existing 16 single-channel modular BES system with additional 16 spatial channels. The BES collects the Doppler-shifted Balmer Dα emission with a spatial resolution of 1 cm (radial) × 1.5 cm (poloidal) and a temporal resolution of 0.5 µs to measure long-wavelength (k⊥ρi < 1) density fluctuations. Compared to the modular BES, the dark noise of the integrated BES is reduced by 50%-60% on average. The signal-to-noise ratio of the integrated BES system is optimized by the high light throughput front-end optics, high quantum efficiency photodiodes, high-gain, low-noise preamplifiers, and sufficient cooling capacity provided by the thermoelectric cooling (TEC) units that maintain the detectors at -20 °C. Crosstalk between channels that share the same optical system is found to be negligible. High-quality density fluctuation data enables 2D (radial-poloidal) imaging of turbulence, which allows for multi-channel spectral analysis, multi-channel cross-correlation analysis and velocimetry analysis. Preliminary results show that BES successfully captures the spatiotemporal features of the local turbulence and obtains statistically consistent turbulence characterization results.

7.
Rev Sci Instrum ; 93(7): 073506, 2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35922327

ABSTRACT

A conceptual design for a 2D beam emission spectroscopy diagnostic system to measure ion gyro-scale plasma turbulence at Wendeslstein 7-X is described. The conceptual design identifies field-aligned viewing geometries and ports for cross-field turbulence measurements in the neutral beam volume. A 2D sightline grid covers the outer plasma region, and the grid configuration provides sufficient k-space coverage in radial and poloidal directions for ion temperature gradient and trapped-electron mode turbulence measurements. Emission intensity estimates, optical transmission losses, and detector noise levels indicate that the measurements will be sensitive to plasma density fluctuations as small as δn/n ≈ 0.5% with a bandwidth of 1 MHz. Implementation challenges include a small beam emission Doppler shift due to nearly radial heating beams and reduced optical throughput due to collection aperture limitations.

8.
Phys Rev Lett ; 128(18): 185001, 2022 May 06.
Article in English | MEDLINE | ID: mdl-35594094

ABSTRACT

Global gyrokinetic simulations of mesoscale reversed shear Alfven eigenmodes (RSAE) excited by energetic particles (EP) in fusion plasmas find that RSAE amplitude and EP transport are much higher than experimental levels at nonlinear saturation, but quickly diminish to very low levels after the saturation if background microturbulence is artificially suppressed. In contrast, in simulations coupling micro-meso scales, the RSAE amplitude and EP transport decrease drastically at the initial saturation but later increases to the experimental levels in the quasisteady state with bursty dynamics due to regulation by thermal ion temperature gradient (ITG) microturbulence. The quasisteady state EP transport is larger for a stronger microturbulence. The RSAE amplitude in the quasisteady state ITG-RSAE turbulence from gyrokinetic simulations, for the first time, agrees very well with experimental measurements.

9.
Phys Rev Lett ; 127(23): 235002, 2021 Dec 03.
Article in English | MEDLINE | ID: mdl-34936805

ABSTRACT

Fast ion phase-space flow, driven by Alfvén eigenmodes (AEs), is measured by an imaging neutral particle analyzer in the DIII-D tokamak. The flow firstly appears near the minimum safety factor at the injection energy of neutral beams, and then moves radially inward and outward by gaining and losing energy, respectively. The flow trajectories in phase space align well with the intersection lines of the constant magnetic moment surfaces and constant E-(ω/n)P_{ζ} surfaces, where E, P_{ζ} are the energy and canonical toroidal momentum of ions; ω and n are angular frequencies and toroidal mode numbers of AEs. It is found that the flow is so destructive that the thermalization of fast ions is no longer observed in regions of strong interaction. The measured phase-space flow is consistent with nonlinear hybrid kinetic-magnetohydrodynamics simulation. Calculations of the relatively narrow phase-space islands reveal that fast ions must transition between different flow trajectories to experience large-scale phase-space transport.

10.
Rev Sci Instrum ; 92(5): 053513, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34243242

ABSTRACT

An upgraded detector and several optimizations have significantly improved the Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic sensitivity to ion temperature and parallel velocity fluctuations at turbulence relevant spatio-temporal scales. Normalized broadband ion temperature and parallel velocity fluctuations down to x̃x∼1% (x = Ti, v∥) and up to ∼450 kHz have been measured in a variety of plasmas. The multi-field nature of the CHERS technique also allows measurements of the cross-phase angles of the fluctuating fields. UF-CHERS is optimized to observe emissions from the electron exchange reaction between intrinsic C6+ and hydrogenic neutral beam injected particles near 529 nm. UF-CHERS consists of two chords separated by ∼1 cm radially, less than the turbulence correlation length in DIII-D plasmas, which enables correlated measurements to suppress incoherent electronic and photon noise. The optical components of the spectrometer include a volume-phase-holographic grating with >90% transmission between 528 and 530 nm and f/2 200-mm lenses, selected to maximize the optical efficiency and photon flux. Diffracted light from each chord is collected in eight spectral bins, each with a bandwidth of ∼0.25 nm, and detected and amplified by chilled avalanche photodiodes and custom high-gain, wide bandwidth low-noise preamplifiers to achieve the optimal signal-to-noise ratio. The resulting signals are digitized at 1 MHz, 103-104× faster than the conventional CHERS diagnostics. Spatial coverage is achieved by repositioning a motorized fiber tray between plasmas. UF-CHERS measurements will advance the understanding of turbulent ion transport and contribute to the validation of transport models and simulations.

11.
Appl Opt ; 60(16): 4885-4891, 2021 Jun 01.
Article in English | MEDLINE | ID: mdl-34143050

ABSTRACT

High resolution luminosity product measurements of neutral beam emission in magnetized plasmas are severely limited by the artificial Doppler broadening inherent to the use of large diameter collection optics. In this paper, a broadening compensation method is developed for the spatial heterodyne spectroscopy interferometric technique. The compensation technique greatly reduces the artificial broadening, thereby enabling high resolution measurements at a significantly higher photon flux than previously available. Compensated and uncompensated measurements of emission generated by impact excitation of 61 keV deuterium neutrals in a tokamak plasma at the DIII-D National Fusion Facility are presented. The spectral width of the compensated measurement is ${\sim}0.13 \;{\rm{nm}}$, which is comparable to the instrument resolution. This width is ${\sim}4 \times$ smaller than the uncompensated width, which for the 20 cm diameter collection lens system utilized in this study is ${\sim}0.5 \;{\rm{nm}}$.

12.
Phys Rev Lett ; 123(11): 115001, 2019 Sep 13.
Article in English | MEDLINE | ID: mdl-31573275

ABSTRACT

We observe the formation of a high-pressure staircase pedestal (≈16-20 kPa) in the DIII-D tokamak when large amplitude edge localized modes are suppressed using resonant magnetic perturbations. The staircase pedestal is characterized by a flattening of the density and temperature profiles in midpedestal creating a two-step staircase pedestal structure correlated with the appearance of midpedestal broadband fluctuations. The pedestal oscillates between the staircase and single-step structure every 40-60 ms, correlated with oscillations in the heat and particle flux to the divertor. Gyrokinetic analysis using the cgyro code shows that when the heat and particle flux to the divertor decreases, the pedestal broadens and the E×B shear at the midpedestal decreases, triggering a transport bifurcation from the kinetic ballooning mode (KBM) to trapped electron mode (TEM) limited transport that flattens the density and temperature profiles at midpedestal and results in the formation of the staircase pedestal. As the heat flux to the divertor increases, the pedestal narrows and the E×B shear at the midpedestal increases, triggering a back transition from TEM to KBM limited transport. The pedestal pressure increases during the staircase phase, indicating that enhanced midpedestal turbulence can be beneficial for confinement.

13.
Phys Rev Lett ; 122(11): 115001, 2019 Mar 22.
Article in English | MEDLINE | ID: mdl-30951344

ABSTRACT

Plasma discharges with a negative triangularity (δ=-0.4) shape have been created in the DIII-D tokamak with a significant normalized beta (ß_{N}=2.7) and confinement characteristic of the high confinement mode (H_{98y2}=1.2) despite the absence of an edge pressure pedestal and no edge localized modes (ELMs). These inner-wall-limited plasmas have a similar global performance as a positive triangularity (δ=+0.4) ELMing H-mode discharge with the same plasma current, elongation and cross sectional area. For cases both of dominant electron cyclotron heating with T_{e}/T_{i}>1 and dominant neutral beam injection heating with T_{e}/T_{i}=1, turbulent fluctuations over radii 0.5<ρ<0.9 were reduced by 10-50% in the negative triangularity shape compared to the matching positive triangularity shape, depending on the radius and conditions.

14.
Phys Rev Lett ; 121(23): 235001, 2018 Dec 07.
Article in English | MEDLINE | ID: mdl-30576208

ABSTRACT

Prior to eruptive events such as edge localized modes (ELMs), quasicoherent fluctuations, referred to as pedestal modes, are observed in the edge of fusion devices. We report on the investigations of nonlinear coupling between these modes during quasistationary inter-ELM phases leading to the ELM onset. Three dominant modes, with density and magnetic signatures, are identified as key players in the triggering mechanism of certain classes of ELMs. We demonstrate that one of these modes is amplified by the two others through three wave interactions. The amplified mode is radially shifted relative to the other two modes towards the last-closed flux surface as the ELM event approaches. Our results suggest that nonlinear coupling of pedestal modes, associated with radial distortions pushing out of the pedestal, is a possible mechanism for the triggering of low frequency ELMs relevant for future fusion devices.

15.
Rev Sci Instrum ; 89(10): 10D122, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399666

ABSTRACT

A beam emission spectroscopy system is being developed and deployed on the HL-2A tokamak to measure local low wavenumber (k ⊥ ρ i < 1) density fluctuations by measuring the Doppler-shifted emission from a 50 kV deuterium heating neutral beam. High spatial resolution (Δr ≤ 1 cm, Δz ≤ 1.5 cm) measurements are achieved with customized in-vacuum optics. High frequency, high-gain preamplifiers sample the light intensity at a Nyquist frequency of 1 MHz and achieve a high S/N ratio via high optical throughput, low-noise preamplifiers, and high quantum efficiency photodiodes. A first set of 16 detector channels [configured in an 8 (radial) × 2 (poloidal) array] has been installed and tested at HL-2A, covering the radial range r/a = 0.8-1.1. The frequency and wavenumber spectra have been measured under different plasma conditions. Initial measurements have demonstrated the capability of measuring edge plasma density fluctuation spectra and the poloidal flow velocity fields with a high S/N ratio.

16.
Rev Sci Instrum ; 89(10): 10E107, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399767

ABSTRACT

The 2D turbulent E × B flow-field is inferred from density fluctuation images obtained with the beam emission spectroscopy diagnostic on DIII-D using the orthogonal dynamic programming velocimetry algorithm. A synthetic turbulence model is used to test the algorithm and optimize it for measuring zonal flows. Zonal flow measurements are found to require a signal-to-noise ratio above ∼10 and a zonal flow wavelength longer than ∼2 cm. Comparison between the velocimetry-estimated flow-field and the E × B flow-field using a nonlinear gyrokinetic GENE simulation finds that the flow-fields have identical spatial structure and differ only by the mean turbulence phase velocity, which is spatially uniform in this flux tube simulation.

17.
Rev Sci Instrum ; 89(10): 10D114, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399811

ABSTRACT

Measurement of electrostatic potential, or local electric field, turbulence is a critical missing component in validating nonlinear turbulence and transport simulations of fusion plasmas. A novel diagnostic is being developed for measuring local electric field fluctuations, E ̃ ( r , t ) , via high-speed measurements of the light emitted from a hydrogenic neutral beam. It exploits the proportionality of the spectral line splitting from the Motional Stark Effect to the total electric field experienced by the neutral atom at the excitation site. The measurement is localized by the usual cross-beam geometry of beam-spectroscopy measurements. The corner stone of the diagnostic is a high spectral resolution, high etendue spatial heterodyne spectrometer (SHS). A SHS design with high etendue (∼5 mm2 sr) and resolution (∼0.14 nm) meets the formidable spectrometer requirements. Field tests of the spectrometer at the DIII-D tokamak demonstrate that the beam emission spectrum produced by the SHS agrees with that of a traditional spectrometer and that the measured flux is adequate for turbulence studies.

18.
Phys Rev Lett ; 120(24): 245001, 2018 Jun 15.
Article in English | MEDLINE | ID: mdl-29956950

ABSTRACT

The hysteresis relation between turbulence and temperature modulation during the heat pulse propagation into a magnetic island is studied for the first time in toroidal plasmas. Lissajous curves of the density fluctuation (n[over ˜]/n) and the electron temperature (T_{e}) modulation show that the (n[over ˜]/n) propagation is faster than the heat pulse propagation near the O point of the magnetic island. This faster n[over ˜]/n propagation is experimental evidence of the turbulence spreading from the X point to the O point of the magnetic island.

19.
Can Commun Dis Rep ; 44(12): 317-322, 2018 Dec 06.
Article in English | MEDLINE | ID: mdl-31517952

ABSTRACT

BACKGROUND: Invasive pneumococcal disease (IPD) is a significant cause of morbidity and mortality; however, outbreaks of IPD are relatively rare. Homelessness and substance use are known risk factors for IPD and have been associated with several outbreaks in Canada, despite national recommendations for routine childhood and targeted adult pneumococcal vaccination. OBJECTIVES: To describe the epidemiology and public health challenges related to an outbreak of novel serotype 4 IPD in a homeless and unstably housed population in Victoria, British Columbia during the autumn and winter of 2016-2017. RESULTS: Prospective, enhanced surveillance was initiated for laboratory confirmed cases reported to public health, including variables recording housing status and substance use. Thirty-three cases of serotype 4 IPD within the Victoria area were reported to public health between August 1, 2016 and September 1, 2017. Compared with other serotypes, these cases were more likely to be middle-aged, homeless or unstably housed, and to have a recent history of substance use. A targeted pneumococcal vaccination campaign was initiated in collaboration with external community organizations; however, these initiatives were challenged by incomplete data and staffing constraints. CONCLUSION: This report illustrates an outbreak of serotype 4 IPD among an inner-city population with multiple risk factors, including homelessness, unstable housing and substance use. Given the challenges controlling the outbreak, outreach capacity and pneumococcal vaccination coverage is needed among this marginalized population.

20.
Rev Sci Instrum ; 87(11): 11E551, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910350

ABSTRACT

The Ultra-Fast Charge Exchange Recombination Spectroscopy (UF-CHERS) diagnostic is a highly specialized spectroscopic instrument with 2 spatial channels consisting of 8 spectral channels each and a resolution of ∼0.25 nm deployed at DIII-D to measure turbulent ion temperature fluctuations. Charge exchange emissions are obtained between 528 and 530 nm with 1 µs time resolution to study plasma instabilities. A primary challenge of extracting fluctuation measurements from raw UF-CHERS signals is photon and electronic noise. In order to reduce dark current, the Avalanche Photodiode (APD) detectors are thermo-electrically cooled. State-of-the-art components are used for the signal amplifiers and conditioners to minimize electronic noise. Due to the low incident photon power (≤1 nW), APDs with a gain of up to 300 are used to optimize the signal to noise ratio. Maximizing the APDs' gain while minimizing the excess noise factor (ENF) is essential since the total noise of the diagnostic sets a floor for the minimum level of detectable broadband fluctuations. The APDs' gain should be high enough that photon noise dominates electronic noise, but not excessive so that the ENF overwhelms plasma fluctuations. A new generation of cooled APDs and optimized preamplifiers exhibits significantly enhanced signal-to-noise compared to a previous generation. Experiments at DIII-D have allowed for characterization and optimization of the ENF vs. gain. A gain of ∼100 at 1700 V is found to be near optimal for most plasma conditions. Ion temperature and toroidal velocity fluctuations due to the edge harmonic oscillation in quiescent H-mode plasmas are presented to demonstrate UF-CHERS' capabilities.

SELECTION OF CITATIONS
SEARCH DETAIL
...