Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Science ; 325(5948): 1660, 2009 Sep 25.
Article in English | MEDLINE | ID: mdl-19779192

ABSTRACT

European eels (Anguilla anguilla) undertake a approximately 5000-kilometer (km) spawning migration from Europe to the Sargasso Sea. The larvae are transported back to European waters by the Gulf Stream and North Atlantic Drift. However, details of the spawning migration remain unknown because tracking eels in the Atlantic Ocean has, so far, eluded study. Recent advances in satellite tracking enable investigation of migratory behavior of large ocean-dwelling animals. However, sizes of available tags have precluded tracking smaller animals like European eels. Here, we present information about the swimming direction, depth, and migratory behavior of European eels during spawning migration, based on a miniaturized pop-up satellite archival transmitter. Although the tagging experiment fell short of revealing the full migration to the Sargasso Sea, the data covered the first 1300 km and provided unique insights.


Subject(s)
Anguilla/physiology , Animal Migration , Swimming , Animals , Atlantic Ocean , Body Temperature Regulation , Ecosystem , Europe , Reproduction , Temperature , Water Movements
2.
Am J Phys Med Rehabil ; 85(7): 553-8, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16788385

ABSTRACT

OBJECTIVE: To compare the reliability, validity, and responsiveness of a thermistor thermometer (thermistor) and two different infrared thermometers (one designed to measure tympanic temperature and one for skin temperature). DESIGN: Reliability and validity were evaluated by making two separate measurements from the skin at identical spots of each hand, forearm, shoulder, thigh, shin, and foot in 17 healthy subjects. Intramuscular temperature was recorded at the hand and shin sites. Test-retest reliability was calculated using intraclass correlation for each instrument. Pearson correlation assessed the relationship between the skin and intramuscular temperatures at the hand and shin sites (validity). Each instrument's ability to measure temperature change (responsiveness) was assessed by measuring skin temperatures serially from 17 limbs of ten patients with complex regional pain syndrome undergoing intravenous regional sympathetic blockade. Responsiveness index values were calculated. RESULTS: Reliability was strong and similar for each device (intraclass correlation: thermistor = 0.96, tympanic = 0.96, skin = 0.97), as was validity (r: thermistor = 0.90, tympanic = 0.92, skin = 0.92). Responsiveness was marginally better for the infrared skin device (responsiveness index: skin = 4.2, tympanic = 3.6, thermistor = 3.6). CONCLUSIONS: For the purposes of clinical electrodiagnostic laboratory and other physiatry applications, the performance of the infrared thermometers is equal to or superior to that of the traditionally used thermistor. All three devices are highly reliable and valid, whereas the infrared skin device is slightly more responsive. Infrared thermometers have the advantage of being quicker to operate and more portable.


Subject(s)
Skin Temperature , Thermography/instrumentation , Thermometers , Adult , Equipment Design , Female , Humans , Male , Middle Aged , Reference Values , Reproducibility of Results , Tympanic Membrane
SELECTION OF CITATIONS
SEARCH DETAIL
...