Nucl Med Commun ; 41(6): 589-596, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32282637

ABSTRACT

The withdrawal of Cr-chromate has meant that the technique commonly used for direct measurement of red cell volume has had to be replaced. Most centres moved to a Tc erythrocyte label, however, Tc is known to dissociate over time. We have investigated an alternative technique using an In-chloride and tropolone solution and tested this both in vitro and in vivo. Initial in-vitro and in-vivo work, which included a check of the stability of the radio-labelled product at one hour, demonstrated this label to be stable over this time period. To date, 20 patients have undergone this technique and results show that this technique is a viable alternative to Cr-chromate particularly for patients with splenomegaly who require late sampling. This procedure is now in routine use in our institution.


Subject(s)
Chromium Radioisotopes/metabolism , Erythrocyte Volume , Indium Radioisotopes/metabolism , Isotope Labeling/methods , Humans