Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Int J Clin Monit Comput ; 2(3): 167-80, 1986.
Article in English | MEDLINE | ID: mdl-3755155

ABSTRACT

We describe a system useful for collecting and analyzing breath-by-breath exercise test data in the field. In studies of untrained subjects, analysis of artifacts is particularly important. Our system uses pattern-recognition criteria to reject breaths if the breathing valves do not operate satisfactorily or if deviations from the calibrating baseline occur.


Subject(s)
Physical Exertion , Respiratory Function Tests/methods , Altitude , Humans , Pulmonary Gas Exchange , Respiratory Function Tests/instrumentation , Software
2.
J Appl Physiol (1985) ; 59(5): 1495-502, 1985 Nov.
Article in English | MEDLINE | ID: mdl-4066580

ABSTRACT

A native of the Peruvian Andes (4,250 m) was studied before and after isovolemic hemodilution of the hematocrit from 62 to 42%. O2 transport was studied with newly developed catheters in the radial and pulmonary arteries. These catheters allowed continuous measurement of arteriovenous O2 content and intermittent cardiac output by thermodilution. During exercise tests, breath-by-breath gas exchange measurements also allowed cardiac output to be calculated by the O2-Fick technique. A complex series of interrelated physiological changes occurred in response to hemodilution. These included increased ventilation, increased arterial and mixed venous PO2, increased cardiac output (both heart rate and stroke volume), and improved ventilation-flow match. The general improvement in symptoms that followed hemodilution correlated well with increased anaerobic threshold and mixed venous PO2 during exercise.


Subject(s)
Altitude , Hemodilution , Oxygen/blood , Polycythemia/blood , Pulmonary Gas Exchange , Bloodletting , Hematocrit , Humans , Male , Middle Aged , Physical Exertion , Polycythemia/physiopathology
3.
Clin Chem ; 30(1): 93-7, 1984 Jan.
Article in English | MEDLINE | ID: mdl-6690157

ABSTRACT

In developing a Reference Material for alkaline phosphatase, we studied the stability, kinetic properties, and commutability of separate preparations of the purified enzyme from human liver, intestine, bone, and placenta. The Michaelis constants (Km) for the preparations from liver, bone, and intestine agreed well with the Km values we obtained for five human serum specimens, whereas that for the placental isoenzyme differed significantly. The first three isoenzymes exhibited nearly identical response-surface patterns, which closely paralleled those observed for 12 human serum specimens (commutability), but not that of the placental isoenzyme. Thus, we believe that a reference material could equally well consist of either the bone, intestinal, or liver isoenzyme. All four isoenzymes were satisfactorily stable in temperature-accelerated degradation studies. We chose the liver isoenzyme as an appropriate reference material because liver tissue is easier to obtain than bone or intestine and the isoenzyme is abundant in liver, is easy to extract, and is the one most commonly increased in human serum. This material is stable at -20 degrees C, is free of interfering and degradative enzymes and, being of human origin, is commutable with the enzyme in human serum.


Subject(s)
Alkaline Phosphatase/standards , Isoenzymes/standards , Adult , Alkaline Phosphatase/isolation & purification , Analysis of Variance , Bone and Bones/enzymology , Child , Female , Humans , Hydrogen-Ion Concentration , Intestines/enzymology , Isoenzymes/isolation & purification , Kinetics , Liver/enzymology , Placenta/enzymology
4.
Clin Biochem ; 15(3): 160-6, 1982 Jun.
Article in English | MEDLINE | ID: mdl-7116626

ABSTRACT

Purified isoenzymes of aspartate aminotransferase (AST) from human liver (mitochondrial) and erythrocytes (cytoplasmic) were used to elicit antisera in rabbits. Each antiserum was characterized for titer and specificity. Complexes formed upon addition of each isoenzyme to its specific antiserum were demonstrated to be catalytically inactive. Results obtained when either filtration or centrifugation was used for separating the complexes (heterogeneous assay) were comparable to those obtained when the complexes were not separated (homogeneous assay) from the mixture before assay. A quality control system was designed to monitor specificity in addition to the usual parameters. The precision for the inhibition of cytoplasmic (CV 4.8%) and mitochondrial (CV 3.5%) isoenzymes was within that of the enzymatic assay. Several parametric conditions of the enzyme-antibody reactions were examined, and the assay was adapted for semi-automation. The homogeneous assay was evaluated with a series of pseudo specimens containing known mixtures of pure isoenzymes to determine the extent of recovery (99.8%) for a particular isoenzyme in the presence of varying concentrations of the other isoenzyme. In addition, sera from patients having elevated AST concentrations were examined for isoenzyme contributions to total AST activity. A mean recovery of 96% was obtained for these specimens.


Subject(s)
Aspartate Aminotransferases/analysis , Isoenzymes/analysis , Antibody Specificity , Humans , Immune Sera/analysis , Immunoassay/methods
5.
Clin Chem ; 28(1): 41-4, 1982 Jan.
Article in English | MEDLINE | ID: mdl-7055935

ABSTRACT

We examined the stability of creatine kinase (EC 2.7.3.2) isoenzyme-3 (CK-3) in lyophilized bovine albumin matrices in the presence and absence of various sulfhydryl compounds and ADP. We initially purified CK-3 from human myocardium and skeletal muscle by the batch-chromatographic technique and by gradient elution column chromatography to specific activities of 293 and 93 kU/g, respectively. To assess stability, we subjected the lyophilized materials to storage studies at 4, 25, 37, 42, 56, and 65 degrees C and compared first-order rate constants for the decay of creatine kinase activity at 42 degrees C. Our most stable matrix contained, per liter, 2 mmol of ADP and 10 mmol of N-acetylcysteine, and had an extrapolated first-order half-life (Arrhenius plot) at -20 degrees C of approximately 60000 years.


Subject(s)
Creatine Kinase/isolation & purification , Reference Standards , Enzyme Activation , Freeze Drying , Half-Life , Humans , Isoenzymes , Kinetics , Muscles/enzymology , Myocardium/enzymology , Specimen Handling , Temperature
6.
Clin Chem ; 27(5): 714-20, 1981 May.
Article in English | MEDLINE | ID: mdl-6164507

ABSTRACT

We describe the preparation and characterization of materials containing human pancreatic and salivary alpha-amylase (EC 3.2.1.1) and examine their relationship to endogenous amylase in human serum. Amylase was purified from human pancreas and saliva by solvent- and salt-fractionation and column chromatography to specific activities of 63 and 279 kU/g, respectively. Four liquid pools, differing only in activity, were prepared from each source of amylase, each in a matrix containing, per liter: 30 g of human albumin, 50 mmol of sodium chloride, 1 mmol of calcium chloride, and 50 mmol of Tris hydrochloride buffer, pH 7.4. Characterization of the pools showed that the amylase activity in the materials was stable for at least six months at 25 degrees C; among-vial variability of amylase activity was less than or equal to 0.5% (2 CV); and the pools were free from eight possible contaminating enzymes. Plots of salivary vs pancreatic amylase activity measure in our materials with eight commercially available methods showed least-squares slopes ranging from 0.51 to 1.0. The intermethod "commutability" of the materials (i.e., how closely they mimic endogenous serum amylase) was examined in relationship to approximately 100 human sera.


Subject(s)
Amylases/metabolism , Pancreas/enzymology , Saliva/enzymology , alpha-Amylases/metabolism , Humans , Kinetics , Organ Specificity , alpha-Amylases/blood , alpha-Amylases/isolation & purification
8.
Clin Chem ; 25(10): 1691-5, 1979 Oct.
Article in English | MEDLINE | ID: mdl-476916

ABSTRACT

We compare a column-chromatographic method and a homogeneous immunoassay method for separately measuring the mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase. Analytical recovery for the two methods averaged 102% (SD, 2%) and 103% (SD, 4%), respectively, for 11 pools prepared by adding the purified isoenzymes to serum and 102% (SD 8.9%) and 89% (SD, 8.1%) for 26 unaltered specimens of human serum. In comparing the results of the immunoassay method (y) to the chromatographic method (x), our measurements agreed closely for the mitochondrial (y = 0.947 X + 7, r = 0.9991, standard error of estimate = 2.9 U/L) and cytoplasmic (y = 0.92x-6, r = 0.9995, standard error of estimate = 2.1 U/L) isoenzymes in pools prepared from the purified isoenzymes. Similar measurements of the 26 human serum specimens yielded the following results for least-squares evaluation; cytoplasmic isoenzyme y = 1.03x-11, r = 0.994, and standard error of estimate = 6.0 U/L; mitochondrial isoenzyme y = 0.75x+0, r = 0.927, and standard error of estimate = 3.9 U/L.


Subject(s)
Aspartate Aminotransferases/blood , Isoenzymes/blood , Chromatography, Ion Exchange/methods , Cytoplasm/enzymology , Humans , Immunoassay , Kinetics , Mitochondria/enzymology
9.
Clin Chem ; 25(5): 659-64, 1979 May.
Article in English | MEDLINE | ID: mdl-436229

ABSTRACT

Eight different pools of purified human mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase were prepared, to examine the effects of the following matrix variables: the matrix support material (bovine serum albumin and polyvinylpyrrolidone), endogenous pyridoxal concentration, and azide as an antimicrobial preservation. Storage temperatures of 25 and 37 degrees C were used as a rapid and convenient means of accelerating the degradation process. Activity of the enzyme was measured with and without pyridoxal in the reaction solution. We found that the mitochondrial isoenzyme was consistently more labile than the cytoplasmic isoenzyme under identical storage conditions. Both isoenzymes were more stable in matrixes containing bovine serum albumin than in those containing polyvinylpyrrolidone. No apparent difference in the stability of either isoenzyme was observed at matrix pyridoxal concentrations of 15 micromol/L and 150 micromol/L. Only the mitochondrial isoenzyme in matrixes containing bovine serum albumin and 15 micromol of pyridoxal per liter had increased activity (about 9%) when pyridoxal was added to the enzymatic reagent. The amount of activity in reconstituted specimens did not apparently change after 72 h at 4 degrees C.


Subject(s)
Aspartate Aminotransferases/metabolism , Erythrocytes/enzymology , Isoenzymes/metabolism , Mitochondria, Liver/enzymology , Azides/pharmacology , Cytoplasm/enzymology , Drug Stability , Freeze Drying , Humans , Kinetics , Povidone/pharmacology , Pyridoxal/pharmacology , Serum Albumin, Bovine
10.
Clin Chem ; 24(10): 1805-12, 1978 Oct.
Article in English | MEDLINE | ID: mdl-29723

ABSTRACT

We describe a column-chromatographic method for separating the mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase in human serum. Bed height of the ion exchanger, pH, and salt concentrations in the eluting buffers are shown to be variables affecting the separation of the isoenzymes. Under the optimized conditions selected for this study, a 30% increase in volume was observed in one fraction, associated with changing the salt concentration of the eluting buffer and attributed to a contraction of the DEAE-Sephadex A-50. Elution profiles (enzyme activity vs. fraction number) were examined with highly purified mitochondrial and cytoplasmic isoenzymes of human origin in bovine serum albumin and human serum. Recovery of the enzyme in the eluted fractions averaged 102% (SD, 2.0%) for specimens prepared from the purified isoenzymes and 104% (SD, 10.7%) for 38 human serum specimens. The separation technique showed linearity to catalytic concentrations in excess of 200 U/liter (reaction temperature 30 degrees C) for each isoenzyme. Additional information is presented regarding among-day precision and the effect of specimen dilution.


Subject(s)
Aspartate Aminotransferases/isolation & purification , Isoenzymes/isolation & purification , Aspartate Aminotransferases/blood , Chromatography, Ion Exchange , Cytoplasm/enzymology , Humans , Hydrogen-Ion Concentration , Mitochondria/enzymology
11.
Clin Chem ; 24(6): 916-26, 1978 Jun.
Article in English | MEDLINE | ID: mdl-657480

ABSTRACT

The Center for Disease Control (CDC), the New York State Department of Health (NYSDH), the College of American Pathologists, and 23 manufacturers of diagnostic products participated in an interlaboratory study of aspartate aminotransferase (EC 2.6.1.1) methodologies. Six different lyophilized materials were prepared and characterized and then distributed to 293 laboratories for aspartate aminotransferase measurements. The specimens included one human serum; four catalytic concentrations of the cytoplasmic isoenzyme, two purified from human erythrocytes, and two from porcine heart; and one matrix bovine serum albumin (30 g/liter) blank. The purified isoenzymes were prepared in the matrix. We present data on Michaelis parameters (Km and Vmax), Arrhenius plots, activation with pyridoxal 5-phosphate, vial-to-vial variability, and stability on reconstitution. The 281 responses showed that most of the laboratories used NADH-detection methods (91.1%), monitored at 340 nm (79.4%), and reported results in U/liter (89.4%). The percentage of laboratories reporting use of reaction temperatures of 30 and 37 degrees C was evenly divided, i.e., 42.7 and 42%, respectively. Analytical values reported by participating laboratories were categorized by reporting temperature, instrument, and method. Results were most consistent for a selected group of laboratories that supplemented optimized reaction solutions with pyridoxal 5-phosphate.


Subject(s)
Aspartate Aminotransferases/blood , Drug Stability , Erythrocytes/enzymology , Humans , Kinetics , Quality Control
SELECTION OF CITATIONS
SEARCH DETAIL
...