Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Bone Joint J ; 99-B(5): 614-622, 2017 May.
Article in English | MEDLINE | ID: mdl-28455470

ABSTRACT

AIMS: Advocates of debridement, antibiotics and implant retention (DAIR) in hip periprosthetic joint infection (PJI) argue that a procedure not disturbing a sound prosthesis-bone interface is likely to lead to better survival and functional outcome compared with revision. This case-control study aims were to compare outcome of DAIRs for infected primary total hip arthroplasty (THA) with outcomes following primary THA and two-stage revision of infected primary THAs. PATIENTS AND METHODS: We retrospectively reviewed all DAIRs, performed for confirmed infected primary hip arthropasty (n = 82) at out institution, between 1997 and 2013. Data recorded included full patient information and type of surgery. Outcome measures included complications, mortality, implant survivorship and functional outcome. Outcome was compared with two control groups matched for gender and age; a cohort of primary THAs (n = 120) and a cohort of two-stage revisions for infection (n = 66). RESULTS: Mean age at DAIR was 69 years (33 to 87) and mean follow-up was eight years (2 to 17; standard deviation (sd) 5). A total of 52 (63%) of DAIRs were for early PJI (less than six weeks). Greater success in the eradication of infection with DAIR was identified with early PJI, comprising an interval less than a week between onset of symptoms and exchange of modular components with the DAIR procedure. Eradication of infection, complications and re-operation rates were similar in the DAIR and two-stage revision groups. For hips with successful eradication of infection with DAIR, the five-year survival (98%; 95% confidence interval (CI) 94 to 100) was similar to the primary THA group (98%; 95% CI 95 to 100) (n = 43; p = 0.3). The DAIR group had inferior mean Oxford Hip Scores (OHS) (38; 12 to 48) compared with the primary THA group (42; 15 to 48) (p = 0.02) but a significantly better mean OHS compared with the two-stage revision group (31; 0 to 48) (p = 0.008). Patients who required only one DAIR for eradication of infection had a similar mean OHS (41; 20 to 48) to the primary THA group (p = 0.2). CONCLUSION: The DAIR procedure is associated with a similar complication rate and ability to eradicate infection as two-stage revision. This study emphasises the need for exchange of modular components for improved chances of eradication of infection. This is the first study showing that DAIR is better than a two-stage revision regarding functional outcome. Cite this article: Bone Joint J 2017;99-B:614-22.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Arthroplasty, Replacement, Hip/methods , Debridement/methods , Hip Prosthesis/adverse effects , Prosthesis-Related Infections/therapy , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/instrumentation , Case-Control Studies , Combined Modality Therapy , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Reoperation/methods , Retrospective Studies , Treatment Outcome
2.
Bone Joint J ; 96-B(10): 1290-7, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25274911

ABSTRACT

There is great variability in acetabular component orientation following hip replacement. The aims of this study were to compare the component orientation at impaction with the orientation measured on post-operative radiographs and identify factors that influence the difference between the two. A total of 67 hip replacements (52 total hip replacements and 15 hip resurfacings) were prospectively studied. Intra-operatively, the orientation of the acetabular component after impaction relative to the operating table was measured using a validated stereo-photogrammetry protocol. Post-operatively, the radiographic orientation was measured; the mean inclination/anteversion was 43° (sd 6°)/ 19° (sd 7°). A simulated radiographic orientation was calculated based on how the orientation would have appeared had an on-table radiograph been taken intra-operatively. The mean difference between radiographic and intra-operative inclination/anteversion was 5° (sd 5°)/ -8° (sd 8°). The mean difference between simulated radiographic and intra-operative inclination/anteversion, which quantifies the effect of the different way acetabular orientation is measured, was 3°/-6° (sd 2°). The mean difference between radiographic and simulated radiographic orientation inclination/anteversion, which is a manifestation of the change in pelvic position between component impaction and radiograph, was 1°/-2° (sd 7°). This study demonstrated that in order to achieve a specific radiographic orientation target, surgeons should implant the acetabular component 5° less inclined and 8° more anteverted than their target. Great variability (2 sd about ± 15°) in the post-operative radiographic cup orientation was seen. The two equally contributing causes for this are variability in the orientation at which the cup is implanted, and the change in pelvic position between impaction and post-operative radiograph.


Subject(s)
Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Hip Dislocation/prevention & control , Hip Joint/diagnostic imaging , Hip Prosthesis , Osteoarthritis, Hip/surgery , Surgery, Computer-Assisted/methods , Acetabulum/diagnostic imaging , Adult , Aged, 80 and over , Female , Follow-Up Studies , Hip Dislocation/diagnostic imaging , Humans , Imaging, Three-Dimensional , Intraoperative Period , Male , Middle Aged , Osteoarthritis, Hip/diagnostic imaging , Postoperative Period , Prospective Studies , Prosthesis Design , Radiography
3.
Bone Joint J ; 96-B(7): 876-83, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24986939

ABSTRACT

The orientation of the acetabular component is influenced not only by the orientation at which the surgeon implants the component, but also the orientation of the pelvis at the time of implantation. Hence, the orientation of the pelvis at set-up and its movement during the operation, are important. During 67 hip replacements, using a validated photogrammetric technique, we measured how three surgeons orientated the patient's pelvis, how much the pelvis moved during surgery, and what effect these had on the final orientation of the acetabular component. Pelvic orientation at set-up, varied widely (mean (± 2, standard deviation (sd))): tilt 8° (2sd ± 32), obliquity -4° (2sd ± 12), rotation -8° (2sd ± 14). Significant differences in pelvic positioning were detected between surgeons (p < 0.001). The mean angular movement of the pelvis between set-up and component implantation was 9° (sd 6). Factors influencing pelvic movement included surgeon, approach (posterior > lateral), procedure (hip resurfacing > total hip replacement) and type of support (p < 0.001). Although, on average, surgeons achieved their desired acetabular component orientation, there was considerable variability (2sd ± 16) in component orientation. We conclude that inconsistency in positioning the patient at set-up and movement of the pelvis during the operation account for much of the variation in acetabular component orientation. Improved methods of positioning and holding the pelvis are required.


Subject(s)
Arthroplasty, Replacement, Hip , Patient Positioning , Acetabulum/physiology , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/standards , Female , Humans , Male , Middle Aged , Pelvis/physiology , Photogrammetry , Prospective Studies , Rotation
4.
J Orthop Traumatol ; 15(1): 59-62, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23797388

ABSTRACT

Unicompartmental knee replacement (UKR) is now established as a treatment for medial compartment arthritis. The Oxford UKR (Biomet Orthopedics, Inc, Warsaw, IN, USA) has a mobile-bearing system, which minimizes wear. This has been shown to provide excellent long-term results. Dislocation of the mobile-bearing device is rare with an incidence of 1 in 200 (0.5 %). The treatment usually involves exploration of the knee through the original anteromedial incision, removal of the dislocated bearing and rectification of the underlying cause for the dislocation. We describe two cases of a posterior dislocation in which the mobile bearing could not be retrieved and was left in situ. In both cases a good outcome was achieved. We conclude that in extremely rare cases where a dislocated bearing has migrated posteromedially and cannot be retrieved, it can be left in place rather than exploring the joint acutely through a separate posterior incision.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Knee Dislocation/surgery , Knee Prosthesis/adverse effects , Osteoarthritis, Knee/surgery , Device Removal/methods , Female , Humans , Knee Dislocation/diagnostic imaging , Knee Joint/diagnostic imaging , Knee Joint/surgery , Male , Menisci, Tibial/diagnostic imaging , Menisci, Tibial/surgery , Middle Aged , Osteoarthritis, Knee/diagnostic imaging , Prosthesis Failure , Treatment Outcome , Ultrasonography
5.
Maturitas ; 77(2): 185-90, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24289896

ABSTRACT

The burden of revision total hip replacement (THR) surgery is increasing. With an increasing life expectancy and younger age of primary surgery this trend is set to continue. There are few data on the long-term outcome of revision THR. This retrospective study of 1176 consecutive revision THRs with a minimum 10-year follow-up from a University Teaching Hospital was undertaken to review implant survival and patient reported outcomes. Mean follow-up was 11 years with implant survival at 10 years of 82% (CI: 80-85). Implant survival varied between 58% (unexplained pain) to 84% (aseptic loosening) depending on the indication for revision surgery. Positive predictors of survival were age greater than 70 at the time of surgery (p=0.011), revision for aseptic loosening (p<0.01) and revision of both components or just the acetabular component (p<0.01). At the last review, mean Oxford Hip Score (OHS) was 34 (SD: 11.3) and 92% of the living patients with unrevised hips were satisfied with the outcome of revision surgery. This long term study has demonstrated that positive predictors of survival and outcome of revision THR surgery are age greater than 70 years, revision for aseptic loosening and component revision. This should aid surgeons in their counselling of patients prior to surgery.


Subject(s)
Arthroplasty, Replacement, Hip/statistics & numerical data , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Middle Aged , Patient Satisfaction/statistics & numerical data , Reoperation/statistics & numerical data , Retrospective Studies , Young Adult
6.
J Bone Joint Surg Br ; 94(9): 1180-6, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22933488

ABSTRACT

Recent events have highlighted the importance of implant design for survival and wear-related complications following metal-on-metal hip resurfacing arthroplasty. The mid-term survival of the most widely used implant, the Birmingham Hip Resurfacing (BHR), has been described by its designers. The aim of this study was to report the ten-year survival and patient-reported functional outcome of the BHR from an independent centre. In this cohort of 554 patients (646 BHRs) with a mean age of 51.9 years (16.5 to 81.5) followed for a mean of eight years (1 to 12), the survival and patient-reported functional outcome depended on gender and the size of the implant. In female hips (n = 267) the ten-year survival was 74% (95% confidence interval (CI) 83 to 91), the ten-year revision rate for pseudotumour was 7%, the mean Oxford hip score (OHS) was 43 (SD 8) and the mean UCLA activity score was 6.4 (SD 2). In male hips (n = 379) the ten-year survival was 95% (95% CI 92.0 to 97.4), the ten-year revision rate for pseudotumour was 1.7%, the mean OHS was 45 (SD 6) and the mean UCLA score was 7.6 (SD 2). In the most demanding subgroup, comprising male patients aged < 50 years treated for primary osteoarthritis, the survival was 99% (95% CI 97 to 100). This study supports the ongoing use of resurfacing in young active men, who are a subgroup of patients who tend to have problems with conventional THR. In contrast, the results in women have been poor and we do not recommend metal-on-metal resurfacing in women. Continuous follow-up is recommended because of the increasing incidence of pseudotumour with the passage of time.


Subject(s)
Arthroplasty, Replacement, Hip/mortality , Arthroplasty, Replacement, Hip/statistics & numerical data , Equipment Failure Analysis/statistics & numerical data , Granuloma, Plasma Cell/epidemiology , Adolescent , Adult , Age Distribution , Aged , Aged, 80 and over , Causality , Comorbidity , Female , Femoracetabular Impingement/epidemiology , Hip Fractures/epidemiology , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Prosthesis Design , Reoperation/mortality , Sex Distribution , Sex Factors , Surface Properties , Young Adult
7.
J Bone Joint Surg Br ; 92(8): 1072-8, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20675749

ABSTRACT

Pseudotumours are a rare complication of hip resurfacing. They are thought to be a response to metal debris which may be caused by edge loading due to poor orientation of the acetabular component. Our aim was to determine the optimal acetabular orientation to minimise the risk of pseudotumour formation. We matched 31 hip resurfacings revised for pseudotumour formation with 58 controls who had a satisfactory outcome from this procedure. The radiographic inclination and anteversion angles of the acetabular component were measured on anteroposterior radiographs of the pelvis using Einzel-Bild-Roentgen-Analyse software. The mean inclination angle (47 degrees, 10 degrees to 81 degrees) and anteversion angle (14 degrees, 4 degrees to 34 degrees) of the pseudotumour cases were the same (p = 0.8, p = 0.2) as the controls, 46 degrees (29 degrees to 60 degrees) and 16 degrees (4 degrees to 30 degrees) respectively, but the variation was greater. Assuming an accuracy of implantation of +/- 10 degrees about a target position, the optimal radiographic position was found to be approximately 45 degrees of inclination and 20 degrees of anteversion. The incidence of pseudotumours inside the zone was four times lower (p = 0.007) than outside the zone. In order to minimise the risk of pseudotumour formation we recommend that surgeons implant the acetabular component at an inclination of 45 degrees (+/- 10) and anteversion of 20 degrees (+/- 10) on post-operative radiographs. Because of differences between the radiographic and the operative angles, this may be best achieved by aiming for an inclination of 40 degrees and an anteversion of 25 degrees.


Subject(s)
Acetabulum/pathology , Arthroplasty, Replacement, Hip/adverse effects , Granuloma, Plasma Cell/etiology , Acetabulum/diagnostic imaging , Adult , Aged , Arthroplasty, Replacement, Hip/methods , Female , Granuloma, Plasma Cell/prevention & control , Humans , Male , Middle Aged , Orientation , Radiography , Reoperation
8.
J Bone Joint Surg Br ; 92(3): 356-61, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20190305

ABSTRACT

The presence of pseudotumours, which are soft-tissue masses relating to the hip, after metal-on-metal hip resurfacing arthroplasty has been associated with elevated levels of metal ions in serum, suggesting that pseudotumours occur when there is increased wear. We aimed to quantify the wear in vivo of implants revised for pseudotumours (eight) and of a control group of implants (22) revised for other reasons of failure. We found that the implant group with pseudotumours had a significantly higher rate of median linear wear of the femoral component at 8.1 microm/year (2.75 to 25.4) than the 1.79 microm/year (0.82 to 4.15; p = 0.002) of the non-pseudotumour group. For the acetabular component a significantly higher rate of median linear wear of 7.36 microm/year (1.61 to 24.9) was observed in the pseudotumour group compared with 1.28 microm/year (0.81 to 3.33, p = 0.001) in the other group. Wear of the acetabular component in the pseudotumour group always involved the edge of the implant, indicating that edge-loading had occurred. Our findings are the first direct evidence that pseudotumour is associated with increased wear at the metal-on-metal articulation. Furthermore, edge-loading with the loss of fluid-film lubrication may be an important mechanism of generation of wear in patients with a pseudotumour.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Connective Tissue Diseases/surgery , Granuloma, Plasma Cell/surgery , Hip Prosthesis , Prosthesis Failure , Adult , Aged , Connective Tissue Diseases/etiology , Female , Granuloma, Plasma Cell/etiology , Humans , Male , Materials Testing/methods , Middle Aged , Prosthesis Design , Reoperation/methods , Stress, Mechanical , Surface Properties
9.
J Antimicrob Chemother ; 65(3): 569-75, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20053693

ABSTRACT

OBJECTIVES: We describe rates of success for two-stage revision of prosthetic joint infection (PJI), including data on reimplantation microbiology. METHODS: We retrospectively collected data from all the cases of PJI that were managed with two-stage revision over a 4 year period. Patients were managed with an antibiotic-free period before reimplantation, in order to confirm, clinically and microbiologically, that infection was successfully treated. RESULTS: One hundred and fifty-two cases were identified. The overall success rate (i.e. retention of the prosthesis over 5.75 years of follow-up) was 83%, but was 89% for first revisions and 73% for re-revisions [hazard ratio = 2.9, 95% confidence interval (CI) 1.2-7.4, P = 0.023]. Reimplantation microbiology was frequently positive (14%), but did not predict outcome (hazard ratio = 1.3, 95% CI 0.4-3.7, P = 0.6). Furthermore, most unplanned debridements following the first stage were carried out before antibiotics were stopped (25 versus 2 debridements). CONCLUSIONS: We did not identify evidence supporting the use of an antibiotic-free period before reimplantation and routine reimplantation microbiology. Re-revision was associated with a significantly worse outcome.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Joint Diseases/drug therapy , Joint Diseases/surgery , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/surgery , Replantation , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome , Young Adult
11.
J Bone Joint Surg Br ; 91(8): 1019-24, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19651827

ABSTRACT

Inflammatory pseudotumours occasionally occur after metal-on-metal hip resurfacing and often lead to revision. Our aim was to determine the severity of this complication by assessing the outcome of revision in these circumstances and by comparing this with the outcome of other metal-on-metal hip resurfacing revisions as well as that of matched primary total hip replacements. We identified 53 hips which had undergone metal-on-metal hip resurfacing and required revision at a mean of 1.59 years (0.01 to 6.69) after operation. Of these, 16 were revised for pseudotumours, 21 for fracture and 16 for other reasons. These were matched by age, gender and diagnosis with 103 patients undergoing primary total hip replacement with the Exeter implant. At a mean follow-up of three years (0.8 to 7.2) the outcome of metal-on-metal hip resurfacing revision for pseudotumour was poor with a mean Oxford hip score of 20.9 (sd 9.3) and was significantly worse (p < 0.001) than the outcome for fracture with a mean Oxford hip score of 40.2 (sd 9.2) or that for other causes with a mean Oxford hip score of 37.8 (sd 9.4). The clinical outcome of revision for pseudotumour was also significantly worse (p < 0.001) than the outcome of matched primary total hip replacements. By contrast, the outcome for fracture and other causes was not significantly different from that of matched primary total hip replacements (p = 0.065). After revision for pseudotumour there were three cases of recurrent dislocation, three of palsy of the femoral nerve, one of stenosis of the femoral artery and two of loosening of the component. Five hips required further revision. In three of these there was evidence of recurrent pseudotumour, and one is currently awaiting further revision. The incidence of major complications after revision for pseudotumour (50%) was significantly higher (p = 0.018) than that after revision for other causes (14%). The outcome of revision for pseudotumour is poor and consideration should be given to early revision to limit the extent of the soft-tissue destruction. The outcome of resurfacing revision for other causes is good.


Subject(s)
Arthroplasty, Replacement, Hip/adverse effects , Epiphyses/surgery , Femoral Fractures/surgery , Femur Head Necrosis/surgery , Granuloma, Plasma Cell/surgery , Osteoarthritis, Hip/surgery , Adult , Aged , Epiphyses/physiopathology , Female , Femoral Fractures/physiopathology , Femur Head Necrosis/physiopathology , Granuloma, Plasma Cell/physiopathology , Humans , Male , Metals , Middle Aged , Osteoarthritis, Hip/physiopathology , Prognosis , Prosthesis Design , Prosthesis Failure , Reoperation/statistics & numerical data , Severity of Illness Index , Young Adult
12.
J Antimicrob Chemother ; 63(6): 1264-71, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19336454

ABSTRACT

OBJECTIVES: We describe treatment failure rates by antibiotic duration for prosthetic joint infection (PJI) managed with debridement, antibiotics and implant retention (DAIR). METHODS: We retrospectively collected data from all the cases of PJI that were managed with DAIR over a 5 year period. Surgical debridement, microbiological sampling, early intravenous antibiotics and prolonged oral follow-on antibiotics were used. RESULTS: One hundred and twelve cases of PJI were identified. Twenty infections (18%) recurred during a mean follow-up of 2.3 years. The mean duration of antibiotic use was 1.5 years. Failure was more common after arthroscopic debridement, for previously revised joints and for Staphylococcus aureus infection. There were 12 failures after stopping antibiotics and 8 while on antibiotics [hazard ratio (HR) = 4.3, 95% confidence interval (CI) 1.4-12.8, P = 0.01]. However, during the first 3 months of follow-up, there were eight failures after stopping antibiotics and two while on antibiotics (HR = 7.0, 95% CI 1.5-33, P = 0.015). The duration of antibiotic therapy prior to stopping did not predict outcome. CONCLUSIONS: PJI may be managed by DAIR. The risk of failure with this strategy rises after stopping oral antibiotics, but lengthening antibiotic therapy may simply postpone, rather than prevent, failure.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Arthroplasty/adverse effects , Debridement , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/surgery , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome
13.
J Bone Joint Surg Br ; 90(7): 847-51, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18591590

ABSTRACT

We report 17 patients (20 hips) in whom metal-on-metal resurfacing had been performed and who presented with various symptoms and a soft-tissue mass which we termed a pseudotumour. Each patient underwent plain radiography and in some, CT, MRI and ultrasonography were also performed. In addition, histological examination of available samples was undertaken. All the patients were women and their presentation was variable. The most common symptom was discomfort in the region of the hip. Other symptoms included spontaneous dislocation, nerve palsy, a noticeable mass or a rash. The common histological features were extensive necrosis and lymphocytic infiltration. To date, 13 of the 20 hips have required revision to a conventional hip replacement. Two are awaiting revision. We estimate that approximately 1% of patients who have a metal-on-metal resurfacing develop a pseudotumour within five years. The cause is unknown and is probably multifactorial. There may be a toxic reaction to an excess of particulate metal wear debris or a hypersensitivity reaction to a normal amount of metal debris. We are concerned that with time the incidence of these pseudotumours may increase. Further investigation is required to define their cause.


Subject(s)
Granuloma, Plasma Cell/diagnosis , Hip Prosthesis/adverse effects , Adult , Aged , Arthroplasty, Replacement, Hip/instrumentation , Artifacts , Connective Tissue/pathology , Female , Follow-Up Studies , Granuloma, Plasma Cell/pathology , Granuloma, Plasma Cell/surgery , Humans , Magnetic Resonance Imaging , Metals/adverse effects , Middle Aged , Necrosis/etiology , Pain, Postoperative/etiology , Reoperation , Tomography, X-Ray Computed , Ultrasonography
14.
J Bone Joint Surg Br ; 90(5): 556-61, 2008 May.
Article in English | MEDLINE | ID: mdl-18450618

ABSTRACT

The creep and wear behaviour of highly cross-linked polyethylene and standard polyethylene liners were examined in a prospective, double-blind randomised, controlled trial using radiostereometric analysis. We randomised 54 patients to receive hip replacements with either highly cross-linked polyethylene or standard liners and determined the three-dimensional penetration of the liners over three years. After three years the mean total penetration was 0.35 mm (SD 0.14) for the highly cross-linked polyethylene group and 0.45 mm (SD 0.19) for the standard group. The difference was statistically significant (p = 0.0184). From the pattern of penetration it was possible to discriminate creep from wear. Most (95%) of the creep occurred within six months of implantation and nearly all within the first year. There was no difference in the mean degree of creep between the two types of polyethylene (highly cross-linked polyethylene 0.26 mm, SD 0.17; standard 0.27 mm, SD 0.2; p = 0.83). There was, however, a significant difference (p = 0.012) in the mean wear rate (highly cross-linked polyethylene 0.03 mm/yr, SD 0.06; standard 0.07 mm/yr, SD 0.05). Creep and wear occurred in significantly different directions (p = 0.01); creep was predominantly proximal whereas wear was anterior, proximal and medial. We conclude that penetration in the first six months is creep-dominated, but after one year virtually all penetration is due to wear. Highly cross-linked polyethylene has a 60% lower rate of wear than standard polyethylene and therefore will probably perform better in the long term.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/standards , Osteoarthritis, Hip/surgery , Polyethylene/standards , Prosthesis Design/standards , Aged , Arthroplasty, Replacement, Hip/standards , Coated Materials, Biocompatible/standards , Double-Blind Method , Equipment Failure Analysis , Female , Hip Joint/diagnostic imaging , Humans , Male , Materials Testing , Middle Aged , Osteoarthritis, Hip/diagnostic imaging , Polyethylenes/standards , Prospective Studies , Prosthesis Failure , Radiography , Statistics as Topic , Time Factors
15.
J Bone Joint Surg Br ; 90(4): 436-41, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18378915

ABSTRACT

Few independent studies have reported the outcome of resurfacing arthroplasty of the hip. The aim of this study was to report the five-year clinical outcome and seven-year survival of an independent series. A total of 610 Birmingham Hip Resurfacing arthroplasties were performed in 532 patients with a mean age of 51.8 years (16.5 to 81.6). They were followed for between two and eight years; 107 patients (120 hips) had been followed up for more than five years. Two patients were lost to follow-up. At a minimum of five years' follow-up, 79 of 85 hips (93%) had an excellent or good outcome according to the Harris hip score. The mean Oxford hip score was 16.1 points (sd 7.7) and the mean University of California Los Angeles activity score was 6.6 points (sd 1.9). There were no patients with definite radiological evidence of loosening or of narrowing of the femoral neck exceeding 10% of its width. There were 23 revisions (3.8%), giving an overall survival of 95% (95% confidence interval 85.3 to 99.2) at seven years. Fractured neck of femur in 12 hips was the most common indication for revision, followed by aseptic loosening in four. In three hips (three patients) (0.5%), failure was possibly related to metal debris. Considering that these patients are young and active these results are good, and support the use of resurfacing. Further study is needed to address the early failures, particularly those related to fracture and metal debris.


Subject(s)
Arthroplasty, Replacement, Hip/methods , Hip Prosthesis , Osteoarthritis, Hip/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/adverse effects , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteoarthritis, Hip/diagnostic imaging , Radiography , Treatment Outcome
16.
J Infect ; 55(1): 1-7, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17343916

ABSTRACT

OBJECTIVES: This study describes the microbiological spectrum of prosthetic joint infection (PJI) managed by debridement, washout and retention and so guides the choice of empirical antibiotics within this patient group. METHODS: We performed a retrospective review of all patients admitted to our specialist tertiary unit for PJI who were managed with debridement and irrigation or arthroscopic washout of infected prosthetic joints between 1st January 1998 and 30th April 2003. Clinical and microbiological data sets were analysed using the Access database. RESULTS: One hundred and twelve patients met the criteria for inclusion. 69% received their surgical intervention in the first three months after implantation ('early') and 21% after 12 months. Overall the most frequently isolated organisms were coagulase negative staphylococci (47% patients) and methicillin-sensitive Staphylococcus aureus (MSSA, 44% patients). 8% grew methicillin-resistant Staphylococcus aureus (MRSA) and 7% grew anaerobes. Most Gram-negative isolates were resistant to cefuroxime; all were sensitive to meropenem. Eighty-six percent of polymicrobial cultures occurred in early infections when 47% of patients grew more than one organism. MSSA was the most frequently isolated organism at all time points. CONCLUSIONS: Most infections involved staphylococci. MRSA was infrequently isolated. Most polymicrobial infections occurred in early infection. A high rate of resistance to cephalosporins among Gram-negative organisms justifies the use of a broader agent such as a carbapenem in the early empirical antibiotic regime for PJI.


Subject(s)
Anti-Bacterial Agents , Arthroplasty, Replacement/adverse effects , Gram-Negative Bacteria/drug effects , Joint Prosthesis/adverse effects , Prosthesis-Related Infections/drug therapy , Staphylococcus/drug effects , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Debridement , Female , Gram-Negative Bacteria/isolation & purification , Gram-Negative Bacterial Infections/drug therapy , Gram-Negative Bacterial Infections/microbiology , Hip Prosthesis/adverse effects , Humans , Knee Prosthesis/adverse effects , Male , Microbial Sensitivity Tests , Middle Aged , Prosthesis-Related Infections/microbiology , Staphylococcal Infections/microbiology , Staphylococcus/isolation & purification , Staphylococcus aureus/drug effects , Staphylococcus aureus/isolation & purification , Therapeutic Irrigation
17.
J Bone Joint Surg Br ; 87(11): 1468-74, 2005 Nov.
Article in English | MEDLINE | ID: mdl-16260660

ABSTRACT

We inserted an electrode up the femoral neck into the femoral head of ten patients undergoing a metal-on-metal hip resurfacing arthroplasty through a posterior surgical approach and measured the oxygen concentration during the operation. In every patient the blood flow was compromised during surgery, but the extent varied. In three patients, the oxygen concentration was zero at the end of the procedure. The surgical approach caused a mean 60% drop (p < 0.005) in oxygen concentration while component insertion led to a further 20% drop (p < 0.04). The oxygen concentration did not improve significantly on wound closure. This study demonstrates that during hip resurfacing arthroplasty, patients experience some compromise to their femoral head blood supply and some have complete disruption.


Subject(s)
Arthroplasty/methods , Femur Head/surgery , Osteoarthritis, Hip/surgery , Oxygen Consumption , Adult , Aged , Female , Femur Head/blood supply , Femur Head/metabolism , Fluoroscopy , Humans , Male , Metals , Middle Aged , Monitoring, Intraoperative/methods , Nitrous Oxide/metabolism , Regional Blood Flow
18.
J Bone Joint Surg Br ; 87(9): 1197-202, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16129741

ABSTRACT

We followed up 76 consecutive hips with symptomatic acetabular dysplasia treated by acetabular shelf augmentation for a mean period of 11 years. Survival analysis using conversion to hip replacement as an end-point was 86% at five years and 46% at ten years. Forty-four hips with slight or no narrowing of the joint space pre-operatively had a survival of 97% at five and 75% at ten years. This was significantly higher (p = 0.0007) than that of the 32 hips with moderate or severe narrowing of the joint-space, which was 76% at five and 22% at ten years. There was no significant relationship between survival and age (p = 0.37) or the pre- and post-operative centre-edge (p = 0.39) and acetabular angles (p = 0.85). Shelf acetabuloplasty is a reliable, safe procedure offering medium-term symptomatic relief for adults with acetabular dysplasia. The best results were achieved in patients with mild and moderate dysplasia of the hip with little arthritis.


Subject(s)
Acetabulum/surgery , Hip Dislocation, Congenital/surgery , Adolescent , Adult , Arthroplasty, Replacement, Hip , Female , Follow-Up Studies , Hip Dislocation, Congenital/complications , Hip Dislocation, Congenital/diagnostic imaging , Humans , Male , Middle Aged , Osteoarthritis, Hip/diagnostic imaging , Osteoarthritis, Hip/etiology , Postoperative Complications , Radiography , Reoperation , Severity of Illness Index , Survival Analysis , Treatment Outcome
19.
J Bone Joint Surg Br ; 87(7): 921-7, 2005 Jul.
Article in English | MEDLINE | ID: mdl-15972903

ABSTRACT

Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year migration of the Exeter stem with a more recent design, the CPS-Plus, which has a wider shoulder and a more rectangular cross-section. The hypothesis was that these design features would increase rotational stability. Both stems subsided approximately 1 mm relative to the femur during the first two years after implantation. The Exeter stem was found to rotate into valgus (mean 0.2 degrees , sd 0.42 degrees ) and internally rotate (mean 1.28 degrees , sd 0.99 degrees ). The CPS-Plus showed no significant valgus rotation (mean 0.07 [correction] degrees, sd 0.29 [correction] degrees ) or internal rotation (mean -0.03 degrees , sd 0.75 degrees ). A wider, more rectangular cross-section improves rotational stability and may have a better long-term outcome.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Femur/surgery , Osteoarthritis, Hip/surgery , Aged , Aged, 80 and over , Arthroplasty, Replacement, Hip/methods , Female , Hip Joint/surgery , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Failure , Rotation , Treatment Outcome
20.
J Bone Joint Surg Br ; 87(6): 863-6, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15911675

ABSTRACT

We describe a technique of 'cross-hip distraction' to reduce a dislocated hip with subsequent reconstruction of the joint for septic arthritis with extensive femoral osteomyelitis. A 27-year-old woman presented with a dislocated, collapsed femoral head and chronic osteomyelitis of the femur. Examination revealed a leg-length discrepancy of 7 cm and an irritable hip. A staged technique was used with primary clearance of osteomyelitis and secondary reconstruction of the hip. A cross-hip monolateral external fixator was used to establish normal anatomy followed by an arthroplasty. A good functional outcome was achieved. The use of cross-hip distraction avoids soft-tissue and nerve damage and achieved improved abductor function before arthroplasty.


Subject(s)
Arthritis, Infectious/surgery , Arthroplasty, Replacement, Hip/methods , Hip Dislocation/surgery , Osteogenesis, Distraction/methods , Osteomyelitis/surgery , Adult , Arthritis, Infectious/diagnostic imaging , Chronic Disease , Female , Femur Head Necrosis/diagnostic imaging , Femur Head Necrosis/surgery , Hip Dislocation/diagnostic imaging , Humans , Osteomyelitis/diagnostic imaging , Radiography
SELECTION OF CITATIONS
SEARCH DETAIL
...