Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Surgeon ; 22(1): 60-66, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37872052

ABSTRACT

Data on the incidence, management, and consequences of retained microsurgical needles in plastic and reconstructive surgery remains sparse. Research suggests that a mobile C-arm x-ray has a low detection rate for needles of size 8-0 or smaller. By means of a literature review, and survey, we aimed to investigate the current practice employed in the event of the intraoperative loss of a microsurgical needle. A literature review was conducted investigating the incidence, current management strategies, and consequences of retained microsurgical needles. This informed the questions included in a survey investigating management strategies employed in the intra-operative loss of a microsurgical needle. Results from the literature review show an overall low detection rate of microsurgical needles on imaging. Of the forty responders who completed the survey, 80% did not use a mobile C-arm x-ray to locate a missing microsurgical needle. Of the 20% that had done so, x-ray had been unsuccessful in locating the needle in all cases. Portable x-ray has a definite role to play in locating needles of size 7-0 or larger. This study suggests that suture needles of size 8-0 or smaller cannot be reliably detected on x-ray. Regarding management of this event, one should consider the risk of harm to the patient if retained, against the risk of searching for the needle. Based on the results of this work as well as existing published data, we advise against obtaining intra-operative x-rays in the event of a lost needle size 8-0 and above. Appropriate documentation should be completed.


Subject(s)
Foreign Bodies , Microsurgery , Needles , Humans , Radiography , Microsurgery/instrumentation
2.
J Hand Surg Asian Pac Vol ; 28(6): 685-694, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38129762

ABSTRACT

Background: This study introduces a novel method for the management of closed metacarpal neck fractures. Kirschner wires (K-wire) are introduced in a retrograde and the wires withdrawn through skin proximally at the base of the metacarpal. The fracture is reduced using traction and the reduction is maintained by antegrade advancement of the K-wires. The aim of this study is to report the outcomes of this technique. Methods: A total of 36 patients with severely angulated closed metacarpal neck fractures underwent reduction and fixation using this novel method from January 2017 to December 2020 in centres in Ireland and Saudi Arabia. We performed a retrospective review of these patients' clinical data examining their outcomes. Results: Six months postoperatively, all fractures demonstrated bony union and correction of angulation. All patients exhibited excellent range of motion (ROM) with no significant impairment of hand function. Conclusions: The method detailed here is a simple, minimally invasive and reliable technique that has not previously been described. It is suitable for use in the management of closed metacarpal neck fractures of the fourth and fifth metacarpal, with dorsal angulation greater than 60°. Level of Evidence: Level IV (Therapeutic).


Subject(s)
Fracture Fixation, Intramedullary , Fractures, Bone , Fractures, Closed , Hand Injuries , Metacarpal Bones , Humans , Metacarpal Bones/diagnostic imaging , Metacarpal Bones/surgery , Metacarpal Bones/injuries , Fracture Fixation, Intramedullary/methods , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Hand Injuries/surgery , Bone Wires
SELECTION OF CITATIONS
SEARCH DETAIL
...