Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 345
Filter
1.
J Med Internet Res ; 26: e56676, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38870519

ABSTRACT

BACKGROUND: Resting heart rate (HR) and routine physical activity are associated with cardiorespiratory fitness levels. Commercial smartwatches permit remote HR monitoring and step count recording in real-world settings over long periods of time, but the relationship between smartwatch-measured HR and daily steps to cardiorespiratory fitness remains incompletely characterized in the community. OBJECTIVE: This study aimed to examine the association of nonactive HR and daily steps measured by a smartwatch with a multidimensional fitness assessment via cardiopulmonary exercise testing (CPET) among participants in the electronic Framingham Heart Study. METHODS: Electronic Framingham Heart Study participants were enrolled in a research examination (2016-2019) and provided with a study smartwatch that collected longitudinal HR and physical activity data for up to 3 years. At the same examination, the participants underwent CPET on a cycle ergometer. Multivariable linear models were used to test the association of CPET indices with nonactive HR and daily steps from the smartwatch. RESULTS: We included 662 participants (mean age 53, SD 9 years; n=391, 59% women, n=599, 91% White; mean nonactive HR 73, SD 6 beats per minute) with a median of 1836 (IQR 889-3559) HR records and a median of 128 (IQR 65-227) watch-wearing days for each individual. In multivariable-adjusted models, lower nonactive HR and higher daily steps were associated with higher peak oxygen uptake (VO2), % predicted peak VO2, and VO2 at the ventilatory anaerobic threshold, with false discovery rate (FDR)-adjusted P values <.001 for all. Reductions of 2.4 beats per minute in nonactive HR, or increases of nearly 1000 daily steps, corresponded to a 1.3 mL/kg/min higher peak VO2. In addition, ventilatory efficiency (VE/VCO2; FDR-adjusted P=.009), % predicted maximum HR (FDR-adjusted P<.001), and systolic blood pressure-to-workload slope (FDR-adjusted P=.01) were associated with nonactive HR but not associated with daily steps. CONCLUSIONS: Our findings suggest that smartwatch-based assessments are associated with a broad array of cardiorespiratory fitness responses in the community, including measures of global fitness (peak VO2), ventilatory efficiency, and blood pressure response to exercise. Metrics captured by wearable devices offer a valuable opportunity to use extensive data on health factors and behaviors to provide a window into individual cardiovascular fitness levels.


Subject(s)
Cardiorespiratory Fitness , Exercise , Heart Rate , Humans , Heart Rate/physiology , Female , Male , Cardiorespiratory Fitness/physiology , Middle Aged , Exercise/physiology , Cohort Studies , Adult , Exercise Test/methods , Exercise Test/instrumentation , Wearable Electronic Devices
2.
JMIR Hum Factors ; 11: e56653, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38815261

ABSTRACT

BACKGROUND: Studies evaluating the usability of mobile-phone assessments in older adults are limited. OBJECTIVE: This study aims to identify design-based barriers and facilitators to mobile app survey completion among 2 samples of older adults; those in the Framingham Heart Study and a more diverse sample from a hospital-based setting. METHODS: We used mixed methods to identify challenging and beneficial features of the mobile app in participants from the electronic Framingham Heart Study (n=15; mean age of 72 years; 6/15, 40% women; 15/15, 100% non-Hispanic and White) and among participants recruited from a hospital-based setting (n=15; mean age of 71 years; 7/15, 47% women; 3/15, 20% Hispanic; and 8/15, 53% non-White). A variety of app-based measures with different response formats were tested, including self-reported surveys, pictorial assessments (to indicate body pain sites), and cognitive testing tasks (eg, Trail Making Test and Stroop). Participants completed each measure using a think-aloud protocol, while being audio- and video-recorded with a qualitative interview conducted at the end of the session. Recordings were coded for participant usability errors by 2 pairs of coders. Participants completed the Mobile App Rating Scale to assess the app (response range 1=inadequate to 5=excellent). RESULTS: In electronic Framingham Heart Study participants, the average total Mobile App Rating Scale score was 7.6 (SD 1.1), with no significant differences in the hospital-based sample. In general, participants were pleased with the app and found it easy to use. A large minority had at least 1 navigational issue, most committed only once. Most older adults did not have difficulty completing the self-reported multiple-choice measures unless it included lengthy instructions but participants had usability issues with the Stroop and Trail Making Test. CONCLUSIONS: Our methods and results help guide app development and app-based survey construction for older adults, while also giving consideration to sociodemographic differences.


Subject(s)
Mobile Applications , Smartphone , Humans , Aged , Female , Male , Surveys and Questionnaires , Aged, 80 and over
3.
Heart Rhythm ; 21(6): 978-989, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38752904

ABSTRACT

The field of electrophysiology (EP) has benefited from numerous seminal innovations and discoveries that have enabled clinicians to deliver therapies and interventions that save lives and promote quality of life. The rapid pace of innovation in EP may be hindered by several challenges including the aging population with increasing morbidity, the availability of multiple costly therapies that, in many instances, confer minor incremental benefit, the limitations of healthcare reimbursement, the lack of response to therapies by some patients, and the complications of the invasive procedures performed. To overcome these challenges and continue on a steadfast path of transformative innovation, the EP community must comprehensively explore how artificial intelligence (AI) can be applied to healthcare delivery, research, and education and consider all opportunities in which AI can catalyze innovation; create workflow, research, and education efficiencies; and improve patient outcomes at a lower cost. In this white paper, we define AI and discuss the potential of AI to revolutionize the EP field. We also address the requirements for implementing, maintaining, and enhancing quality when using AI and consider ethical, operational, and regulatory aspects of AI implementation. This manuscript will be followed by several perspective papers that will expand on some of these topics.


Subject(s)
Artificial Intelligence , Cardiac Electrophysiology , Delivery of Health Care , Humans , Biomedical Research , Electrophysiologic Techniques, Cardiac/methods
5.
Heart Rhythm ; 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38692342

ABSTRACT

BACKGROUND: Single-lead electrocardiograms (1L ECGs) are increasingly used for atrial fibrillation (AF) detection. Automated 1L ECG interpretation may have prognostic value for future AF in cases in which screening does not result in a short-term AF diagnosis. OBJECTIVE: We sought to investigate the association between automated 1L ECG interpretation and incident AF. METHODS: VITAL-AF was a randomized controlled trial investigating the effectiveness of screening for AF by 1L ECGs. For this study, participants were divided into 4 groups based on automated classification of 1L ECGs. Patients with prevalent AF were excluded. Associations between groups and incident AF were assessed by Cox proportional hazards models adjusted for risk factors. The start of follow-up was defined as 60 days after the latest 1L ECG (as some individuals had numerous screening 1L ECGs). RESULTS: The study sample included never screened (n = 16,306), normal (n = 10,914), other (n = 2675), and possible AF (n = 561). Possible AF had the highest AF incidence (5.91 per 100 person-years; 95% confidence interval [CI], 4.24-8.23). Possible AF was associated with greater hazard of incident AF compared with normal (adjusted hazard ratio, 2.48; 95% CI, 1.66-3.71). Other was associated with greater hazard of incident AF compared with normal (1.41; 95% CI, 1.04-1.90). CONCLUSION: In patients undergoing AF screening with 1L ECGs without prevalent AF or AF within 60 days of screening, presumptive positive and indeterminate 1L ECG interpretations were associated with future AF. Abnormal 1L ECG recordings may identify individuals at higher risk for future AF.

6.
Res Sq ; 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38746125

ABSTRACT

Chronic Obstructive Pulmonary Disease (COPD) is a common, costly, and morbid condition. Pulmonary rehabilitation, close monitoring, and early intervention during acute exacerbations of symptoms represent a comprehensive approach to improve outcomes, but the optimal means of delivering these services is uncertain. Logistical, financial, and social barriers to providing healthcare through face-to-face encounters, paired with recent developments in technology, have stimulated interest in exploring alternative models of care. The Healthy at Home study seeks to determine the feasibility of a multimodal, digitally enhanced intervention provided to participants with COPD longitudinally over six months. This paper details the recruitment, methods, and analysis plan for the study, which is recruiting 100 participants in its pilot phase. Participants were provided with several integrated services including a smartwatch to track physiological data, a study app to track symptoms and study instruments, access to a mobile integrated health program for acute clinical needs, and a virtual comprehensive pulmonary support service. Participants shared physiologic, demographic, and symptom reports, electronic health records, and claims data with the study team, facilitating a better understanding of their symptoms and potential care needs longitudinally. The Healthy at Home study seeks to develop a comprehensive digital phenotype of COPD by tracking and responding to multiple indices of disease behavior and facilitating early and nuanced responses to changes in participants' health status. This study is registered at Clinicaltrials.gov (NCT06000696).

7.
J Am Geriatr Soc ; 2024 May 14.
Article in English | MEDLINE | ID: mdl-38742376

ABSTRACT

BACKGROUND: Cognitive impairment is strongly associated with atrial fibrillation (AF). Rate and rhythm control are the two treatment strategies for AF and the effect of treatment strategy on risk of cognitive decline and frailty is not well established. We sought to determine how treatment strategy affects geriatric-centered outcomes. METHODS: The Systematic Assessment of Geriatric Elements-AF (SAGE-AF) was a prospective, observational, cohort study. Older adults with AF were prospectively enrolled between 2016 and 2018 and followed longitudinally for 2 years. In a non-randomized fashion, participants were grouped by rate or rhythm control treatment strategy based on clinical treatment at enrollment. Baseline characteristics were compared. Longitudinal binary mixed models were used to compare treatment strategy with respect to change in cognitive function and frailty status. Cognitive function and frailty status were assessed with the Montreal Cognitive Assessment Battery and Fried frailty phenotype tools. RESULTS: 972 participants (mean age = 75, SD = 6.8; 49% female, 87% non-Hispanic white) completed baseline examination and 2-year follow-up. 408 (42%) were treated with rate control and 564 (58%) with rhythm control. The patient characteristics of the two groups were different at baseline. Participants in the rate control group were older, more likely to have persistent AF, prior stroke, be treated with warfarin and have baseline cognitive impairment. After adjusting for baseline differences, participants treated with rate control were 1.5 times more likely to be cognitively impaired over 2 years (adjusted OR: 1.47, 95% CI:1.12, 1.98) and had a greater decline in cognitive function (adjusted estimate: -0.59 (0.23), p < 0.01) in comparison to rhythm control. Frailty did not vary between the treatment strategies. CONCLUSIONS: Among those who had 2-year follow-up in non-randomized observational cohort, the decision to rate control AF in older adults was associated with increased odds of decline in cognitive function but not frailty.

8.
Cardiovasc Digit Health J ; 5(2): 50-58, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38765623

ABSTRACT

Background: Depressive symptoms are common and share many biopsychosocial mechanisms with hypertension. Association studies between depressive symptoms and blood pressure (BP) have been inconsistent. Home BP monitoring may provide insight. Objective: To investigate the association between depressive symptoms and digital home BP. Methods: Electronic Framingham Heart Study (eFHS) participants were invited to obtain a smartphone app and digital BP cuff at research exam 3 (2016-2019). Participants with ≥3 weeks of home BP measurements within 1 year were included. Depressive symptoms were measured using the Center for Epidemiological Studies Depression Scale (CES-D). Multivariable linear mixed models were used to test the associations of continuous CES-D score and dichotomous depressive symptoms (CES-D ≥16) (independent) with home BP (dependent), adjusting for age, sex, cohort, number of weeks since baseline, lifestyle factors, diabetes, and cardiovascular disease. Results: Among 883 participants (mean age 54 years, 59% women, 91% White), the median CES-D score was 4. Depressive symptom prevalence was 7.6%. Mean systolic and diastolic BP at exam 3 were 119 and 76 mm Hg; hypertension prevalence was 48%. A 1 SD higher CES-D score was associated with 0.9 (95% CI: 0.18-1.56, P = .01) and 0.6 (95% CI: 0.06-1.07, P = .03) mm Hg higher home systolic BP and diastolic BP, respectively. Dichotomous depressive symptoms were not significantly associated with home BP (P > .2). Conclusion: Depressive symptoms were not associated with clinically substantive levels of home BP. The association between depression and cardiovascular disease risk factors warrants more data, which may be supported by mobile health measures.

9.
JMIR Cardio ; 8: e54801, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38587880

ABSTRACT

BACKGROUND: Short-term blood pressure variability (BPV) is associated with arterial stiffness in patients with hypertension. Few studies have examined associations between arterial stiffness and digital home BPV over a mid- to long-term time span, irrespective of underlying hypertension. OBJECTIVE: This study aims to investigate if arterial stiffness traits were associated with subsequent mid- to long-term home BPV in the electronic Framingham Heart Study (eFHS). We hypothesized that higher arterial stiffness was associated with higher home BPV over up to 1-year follow-up. METHODS: At a Framingham Heart Study research examination (2016-2019), participants underwent arterial tonometry to acquire measures of arterial stiffness (carotid-femoral pulse wave velocity [CFPWV]; forward pressure wave amplitude [FWA]) and wave reflection (reflection coefficient [RC]). Participants who agreed to enroll in eFHS were provided with a digital blood pressure (BP) cuff to measure home BP weekly over up to 1-year follow-up. Participants with less than 3 weeks of BP readings were excluded. Linear regression models were used to examine associations of arterial measures with average real variability (ARV) of week-to-week home systolic (SBP) and diastolic (DBP) BP adjusting for important covariates. We obtained ARV as an average of the absolute differences of consecutive home BP measurements. ARV considers not only the dispersion of the BP readings around the mean but also the order of BP readings. In addition, ARV is more sensitive to measurement-to-measurement BPV compared with traditional BPV measures. RESULTS: Among 857 eFHS participants (mean age 54, SD 9 years; 508/857, 59% women; mean SBP/DBP 119/76 mm Hg; 405/857, 47% hypertension), 1 SD increment in FWA was associated with 0.16 (95% CI 0.09-0.23) SD increments in ARV of home SBP and 0.08 (95% CI 0.01-0.15) SD increments in ARV of home DBP; 1 SD increment in RC was associated with 0.14 (95% CI 0.07-0.22) SD increments in ARV of home SBP and 0.11 (95% CI 0.04-0.19) SD increments in ARV of home DBP. After adjusting for important covariates, there was no significant association between CFPWV and ARV of home SBP, and similarly, no significant association existed between CFPWV and ARV of home DBP (P>.05). CONCLUSIONS: In eFHS, higher FWA and RC were associated with higher mid- to long-term ARV of week-to-week home SBP and DBP over 1-year follow-up in individuals across the BP spectrum. Our findings suggest that higher aortic stiffness and wave reflection are associated with higher week-to-week variation of BP in a home-based setting over a mid- to long-term time span.

10.
J Geriatr Cardiol ; 21(3): 323-330, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38665288

ABSTRACT

BACKGROUND: Smartwatches have become readily accessible tools for detecting atrial fibrillation (AF). There remains limited data on how they affect psychosocial outcomes and engagement in older adults. We examine the health behavior outcomes of stroke survivors prescribed smartwatches for AF detection stratified by age. METHODS: We analyzed data from the Pulsewatch study, a randomized controlled trial that enrolled patients (≥ 50 years) with a history of stroke or transient ischemic attack and CHA2DS2-VASc ≥ 2. Intervention participants were equipped with a cardiac patch monitor and a smartwatch-app dyad, while control participants wore the cardiac patch monitor for up to 44 days. We evaluated health behavior parameters using standardized tools, including the Consumer Health Activation Index, the Generalized Anxiety Disorder questionnaire, the 12-Item Short Form Health Survey, and wear time of participants categorized into three age groups: Group 1 (ages 50-60), Group 2 (ages 61-69), and Group 3 (ages 70-87). We performed statistical analysis using a mixed-effects repeated measures linear regression model to examine differences amongst age groups. RESULTS: Comparative analysis between Groups 1, 2 and 3 revealed no significant differences in anxiety, patient activation, perception of physical health and wear time. The use of smartwatch technology was associated with a decrease in perception of mental health for Group 2 compared to Group 1 (ß = -3.29, P = 0.046). CONCLUSION: Stroke survivors demonstrated a willingness to use smartwatches for AF monitoring. Importantly, among these study participants, the majority did not experience negative health behavior outcomes or decreased engagement as age increased.

11.
PLoS One ; 19(3): e0299516, 2024.
Article in English | MEDLINE | ID: mdl-38457401

ABSTRACT

Point-of-care technology (POCT) plays a vital role in modern healthcare by providing a fast diagnosis, improving patient management, and extending healthcare access to remote and resource-limited areas. The objective of this study was to understand how healthcare professionals in the United States perceived POCTs during 2019-2021 to assess the decision-making process of implementing these newer technologies into everyday practice. A 5-point Likert scale survey was sent to respondents to evaluate their perceptions of benefits, concerns, characteristics, and development of point-of-care technologies. The 2021 survey was distributed November 1st, 2021- February 15th, 2022, with a total of 168 independent survey responses received. Of the respondents, 59% identified as male, 73% were white, and 48% have been in practice for over 20 years. The results showed that most agreed that POCTs improve patient management (94%) and improve clinician confidence in decision making (92%). Healthcare professionals were most concerned with potentially not being reimbursed for the cost of the POCT (37%). When asked to rank the top 3 important characteristics of POCT, respondents chose accuracy, ease of use, and availability. It is important to note this survey was conducted during the COVID-19 pandemic. To achieve an even greater representation of healthcare professionals' point of view on POCTs, further work to obtain responses from a larger, more diverse population of providers is needed.


Subject(s)
Pandemics , Point-of-Care Systems , Humans , Male , Health Personnel , Delivery of Health Care , Surveys and Questionnaires
13.
J Virol ; 98(1): e0161823, 2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38174928

ABSTRACT

The global evolution of SARS-CoV-2 depends in part upon the evolutionary dynamics within individual hosts with varying immune histories. To characterize the within-host evolution of acute SARS-CoV-2 infection, we sequenced saliva and nasal samples collected daily from vaccinated and unvaccinated individuals early during infection. We show that longitudinal sampling facilitates high-confidence genetic variant detection and reveals evolutionary dynamics missed by less-frequent sampling strategies. Within-host dynamics in both unvaccinated and vaccinated individuals appeared largely stochastic; however, in rare cases, minor genetic variants emerged to frequencies sufficient for forward transmission. Finally, we detected significant genetic compartmentalization of viral variants between saliva and nasal swab sample sites in many individuals. Altogether, these data provide a high-resolution profile of within-host SARS-CoV-2 evolutionary dynamics.IMPORTANCEWe detail the within-host evolutionary dynamics of SARS-CoV-2 during acute infection in 31 individuals using daily longitudinal sampling. We characterized patterns of mutational accumulation for unvaccinated and vaccinated individuals, and observed that temporal variant dynamics in both groups were largely stochastic. Comparison of paired nasal and saliva samples also revealed significant genetic compartmentalization between tissue environments in multiple individuals. Our results demonstrate how selection, genetic drift, and spatial compartmentalization all play important roles in shaping the within-host evolution of SARS-CoV-2 populations during acute infection.


Subject(s)
Evolution, Molecular , Genetic Drift , SARS-CoV-2 , Humans , COVID-19/virology , Nose/virology , Saliva/virology , SARS-CoV-2/genetics , Male , Female , Adolescent , Young Adult , Adult , Middle Aged
14.
IEEE Trans Biomed Eng ; 71(2): 456-466, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37682653

ABSTRACT

OBJECTIVE: We propose an efficient approach based on a convolutional denoising autoencoder (CDA) network to reduce motion and noise artifacts (MNA) from corrupted atrial fibrillation (AF) and non-AF photoplethysmography (PPG) data segments so that an accurate PPG-signal-derived heart rate can be obtained. Our method's main innovation is the optimization of the CDA performance for both rhythms using more AF than non-AF data for training the AF-specific CDA model and vice versa for the non-AF CDA network. METHODS: To evaluate this unconventional training scheme, our proposed network was trained and tested on 25-sec PPG data segments from 48 subjects from two different databases-the Pulsewatch dataset and Stanford University's publicly available PPG dataset. In total, our dataset contains 10,773 data segments: 7,001 segments for training and 3,772 independent segments from out-of-sample subjects for testing. RESULTS: Using real-life corrupted PPG segments, our approach significantly reduced the average heart rate root mean square error (RMSE) of the reconstructed PPG segments by 45.74% and 23% compared to the corrupted non-AF and AF data, respectively. Further, our approach exhibited lower RMSE, and higher sensitivity and PPV for detected peaks compared to the reconstructed data produced by the alternative methods. CONCLUSION: These results show the promise of our approach as a reliable denoising method, which should be used prior to AF detection algorithms for an accurate cardiac health monitoring involving wearable devices. SIGNIFICANCE: PPG signals collected from wearables are vulnerable to MNA, which limits their use as a reliable measurement, particularly in uncontrolled real-life environments.


Subject(s)
Atrial Fibrillation , Photoplethysmography , Humans , Photoplethysmography/methods , Atrial Fibrillation/diagnosis , Heart Rate/physiology , Monitoring, Physiologic , Motion , Algorithms , Signal Processing, Computer-Assisted , Artifacts
15.
J Am Heart Assoc ; 13(1): e032126, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38156452

ABSTRACT

BACKGROUND: Consumer wearable devices with health and wellness features are increasingly common and may enhance disease detection and management. Yet studies informing relationships between wearable device use, attitudes toward device data, and comprehensive clinical profiles are lacking. METHODS AND RESULTS: WATCH-IT (Wearable Activity Tracking for Comprehensive Healthcare-Integrated Technology) studied adults receiving longitudinal primary or ambulatory cardiovascular care in the Mass General Brigham health care system from January 2010 to July 2021. Participants completed a 20-question electronic survey about perceptions and use of consumer wearable devices, with responses linked to electronic health records. Multivariable logistic regression was used to identify factors associated with device use. Among 214 992 individuals receiving longitudinal primary or cardiovascular care with an active electronic portal, 11 121 responded (5.2%). Most respondents (55.8%) currently used a wearable device, and most nonusers (95.3%) would use a wearable if provided at no cost. Although most users (70.2%) had not shared device data with their doctor previously, most believed it would be very (20.4%) or moderately (34.4%) important to share device-related health information with providers. In multivariable models, older age (odds ratio [OR], 0.80 per 10-year increase [95% CI, 0.77-0.82]), male sex (OR, 0.87 [95% CI, 0.80-0.95]), and heart failure (OR, 0.75 [95% CI, 0.63-0.89]) were associated with lower odds of wearable device use, whereas higher median income (OR, 1.08 per 1-quartile increase [95% CI, 1.04-1.12]) and care in a cardiovascular medicine clinic (OR, 1.17 [95% CI, 1.05-1.30]) were associated with greater odds of device use. CONCLUSIONS: Among patients in primary and cardiovascular medicine clinics, consumer wearable device use is common, and most users perceive value in wearable health data.


Subject(s)
Wearable Electronic Devices , Adult , Humans , Male , Surveys and Questionnaires , Electronic Health Records , Attitude , Delivery of Health Care
16.
medRxiv ; 2023 Nov 20.
Article in English | MEDLINE | ID: mdl-38045229

ABSTRACT

Objectives: To examine the associations between catheter ablation treatment (CA) versus medical management and cognitive impairment among older adults with atrial fibrillation (AF). Methods: Ambulatory patients who had AF, were ≥ 65-years-old, and were eligible to receive oral anticoagulation could be enrolled into the SAGE (Systematic Assessment of Geriatric Elements)-AF study from internal medicine and cardiology clinics in Massachusetts and Georgia between 2016 and 2018. Cognitive function was assessed using the Montreal Cognitive Assessment (MoCA) tool at baseline, one-, and two years. Cognitive impairment was defined as a MoCA score ≤ 23. Multivariate-adjusted logistic regression of longitudinal repeated measures was used to examine associations between treatment with CA vs. medical management and cognitive impairment. Results: 887 participants were included in this analysis. On average, participants were 75.2 ± 6.7 years old, 48.6% women, and 87.4% white non-Hispanic. 193 (21.8%) participants received a CA before enrollment. Participants who had previously undergone CA were significantly less likely to be cognitively impaired during the two-year study period (aOR 0.70, 95% CI 0.50-0.97) than those medically managed (i.e., rate and/or rhythm control), even after adjusting with propensity score for CA. At the two-year follow-up a significantly greater number of individuals in the non-CA group were cognitively impaired (MoCA ≤ 23) compared to the CA-group (311 [44.8%] vs. 58 [30.1%], p=0.0002). Conclusions: In this two-year longitudinal prospective cohort study participants who underwent CA for AF before enrollment were less likely to have cognitive impairment than those who had not undergone CA.

17.
Front Digit Health ; 5: 1243959, 2023.
Article in English | MEDLINE | ID: mdl-38125757

ABSTRACT

Background: Increasing ownership of smartphones among Americans provides an opportunity to use these technologies to manage medical conditions. We examine the influence of baseline smartwatch ownership on changes in self-reported anxiety, patient engagement, and health-related quality of life when prescribed smartwatch for AF detection. Method: We performed a post-hoc secondary analysis of the Pulsewatch study (NCT03761394), a clinical trial in which 120 participants were randomized to receive a smartwatch-smartphone app dyad and ECG patch monitor compared to an ECG patch monitor alone to establish the accuracy of the smartwatch-smartphone app dyad for detection of AF. At baseline, 14 days, and 44 days, participants completed the Generalized Anxiety Disorder-7 survey, the Health Survey SF-12, and the Consumer Health Activation Index. Mixed-effects linear regression models using repeated measures with anxiety, patient activation, physical and mental health status as outcomes were used to examine their association with smartwatch ownership at baseline. Results: Ninety-six participants, primarily White with high income and tertiary education, were randomized to receive a study smartwatch-smartphone dyad. Twenty-four (25%) participants previously owned a smartwatch. Compared to those who did not previously own a smartwatch, smartwatch owners reported significant greater increase in their self-reported physical health (ß = 5.07, P < 0.05), no differences in anxiety (ß = 0.92, P = 0.33), mental health (ß = -2.42, P = 0.16), or patient activation (ß = 1.86, P = 0.54). Conclusions: Participants who own a smartwatch at baseline reported a greater positive change in self-reported physical health, but not in anxiety, patient activation, or self-reported mental health over the study period.

18.
JMIR Cardio ; 7: e45137, 2023 Nov 28.
Article in English | MEDLINE | ID: mdl-38015598

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is a common cause of stroke, and timely diagnosis is critical for secondary prevention. Little is known about smartwatches for AF detection among stroke survivors. We aimed to examine accuracy, usability, and adherence to a smartwatch-based AF monitoring system designed by older stroke survivors and their caregivers. OBJECTIVE: This study aims to examine the feasibility of smartwatches for AF detection in older stroke survivors. METHODS: Pulsewatch is a randomized controlled trial (RCT) in which stroke survivors received either a smartwatch-smartphone dyad for AF detection (Pulsewatch system) plus an electrocardiogram patch or the patch alone for 14 days to assess the accuracy and usability of the system (phase 1). Participants were subsequently rerandomized to potentially 30 additional days of system use to examine adherence to watch wear (phase 2). Participants were aged 50 years or older, had survived an ischemic stroke, and had no major contraindications to oral anticoagulants. The accuracy for AF detection was determined by comparing it to cardiologist-overread electrocardiogram patch, and the usability was assessed with the System Usability Scale (SUS). Adherence was operationalized as daily watch wear time over the 30-day monitoring period. RESULTS: A total of 120 participants were enrolled (mean age 65 years; 50/120, 41% female; 106/120, 88% White). The Pulsewatch system demonstrated 92.9% (95% CI 85.3%-97.4%) accuracy for AF detection. Mean usability score was 65 out of 100, and on average, participants wore the watch for 21.2 (SD 8.3) of the 30 days. CONCLUSIONS: Our findings demonstrate that a smartwatch system designed by and for stroke survivors is a viable option for long-term arrhythmia detection among older adults at risk for AF, though it may benefit from strategies to enhance adherence to watch wear. TRIAL REGISTRATION: ClinicalTrials.gov NCT03761394; https://clinicaltrials.gov/study/NCT03761394. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1016/j.cvdhj.2021.07.002.

19.
Clin Infect Dis ; 2023 Nov 16.
Article in English | MEDLINE | ID: mdl-37972270

ABSTRACT

BACKGROUND: There is evidence of an association of severe COVID-19 outcomes with increased body mass index (BMI) and male sex. However, few studies have examined the interaction between sex and BMI on SARS-CoV-2 viral dynamics. METHODS: Participants conducted RT-PCR testing every 24-48 hours over a 15-day period. Sex and BMI were self-reported, and Ct values from E-gene were used to quantify viral load. Three distinct outcomes were examined using mixed effects generalized linear models, linear models, and logistic models, respectively: all Ct values (Model 1); nadir Ct value (model 2); and strongly detectable infection (at least one Ct value ≤28 during their infection) (Model 3). An interaction term between BMI and sex was included, and inverse logit transformations were applied to quantify the differences by BMI and sex using marginal predictions. RESULTS: In total, 7,988 participants enrolled in this study, and 439 participants (Model 1) and 309 (Model 2 and 3) were eligible for these analyses. Among males, increasing BMI was associated with lower Ct values in a dose-response fashion. For participants with BMIs greater than 29, males had significantly lower Ct values and nadir Ct values than females. In total, 67.8% of males and 55.3% of females recorded a strongly detectable infection; increasing proportions of men had Ct values <28 with BMIs of 35 and 40. CONCLUSIONS: We observed sex-based dimorphism in relation to BMI and COVID-19 viral load. Further investigation is needed to determine the cause, clinical impact, and transmission implications of this sex-differential effect of BMI on viral load.

20.
BMC Public Health ; 23(1): 1848, 2023 09 22.
Article in English | MEDLINE | ID: mdl-37735647

ABSTRACT

BACKGROUND: Many interventions for widescale distribution of rapid antigen tests for COVID-19 have utilized online, direct-to-consumer (DTC) ordering systems; however, little is known about the sociodemographic characteristics of home-test users. We aimed to characterize the patterns of online orders for rapid antigen tests and determine geospatial and temporal associations with neighborhood characteristics and community incidence of COVID-19, respectively. METHODS: This observational study analyzed online, DTC orders for rapid antigen test kits from beneficiaries of the Say Yes! Covid Test program from March to November 2021 in five communities: Louisville, Kentucky; Indianapolis, Indiana; Fulton County, Georgia; O'ahu, Hawaii; and Ann Arbor/Ypsilanti, Michigan. Using spatial autoregressive models, we assessed the geospatial associations of test kit distribution with Census block-level education, income, age, population density, and racial distribution and Census tract-level Social Vulnerability Index. Lag association analyses were used to measure the association between online rapid antigen kit orders and community-level COVID-19 incidence. RESULTS: In total, 164,402 DTC test kits were ordered during the intervention. Distribution of tests at all sites were significantly geospatially clustered at the block-group level (Moran's I: p < 0.001); however, education, income, age, population density, race, and social vulnerability index were inconsistently associated with test orders across sites. In Michigan, Georgia, and Kentucky, there were strong associations between same-day COVID-19 incidence and test kit orders (Michigan: r = 0.89, Georgia: r = 0.85, Kentucky: r = 0.75). The incidence of COVID-19 during the current day and the previous 6-days increased current DTC orders by 9.0 (95% CI = 1.7, 16.3), 3.0 (95% CI = 1.3, 4.6), and 6.8 (95% CI = 3.4, 10.2) in Michigan, Georgia, and Kentucky, respectively. There was no same-day or 6-day lagged correlation between test kit orders and COVID-19 incidence in Indiana. CONCLUSIONS: Our findings suggest that online ordering is not associated with geospatial clustering based on sociodemographic characteristics. Observed temporal preferences for DTC ordering can guide public health messaging around DTC testing programs.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , COVID-19/epidemiology , Sociodemographic Factors , Educational Status , Censuses , Cluster Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...