1.
Rev Sci Instrum ; 89(10): 10I119, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399763

ABSTRACT

The apparent ion temperature and neutron-reaction history are important characteristics of a fusion plasma. Extracting these quantities from a measured neutron-time-of-flight signal requires accurate knowledge of the instrument response function (IRF). This work describes a novel method for obtaining the IRF directly for single DT neutron interactions by utilizing n-alpha coincidence. The t(d,α)n nuclear reaction was produced at Sandia National Laboratories' Ion Beam Laboratory using a 300 keV Cockcroft-Walton generator to accelerate a 2.5 µA beam of 175 keV D+ ions into a stationary ErT2 target. The average neutron IRF was calculated by taking a time-corrected average of individual neutron events within an EJ-228 plastic scintillator. The scintillator was coupled to two independent photo-multiplier tubes operated in the current mode: a Hamamatsu 5946 mod-5 and a Photek PMT240. The experimental setup and results will be discussed.

2.
Rev Sci Instrum ; 89(10): 10I121, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399775

ABSTRACT

The one-dimensional imager of neutrons (ODIN) at the Sandia Z facility consists of a 10-cm block of tungsten with rolled edges, creating a slit imager with slit widths of either 250, 500, or 750 µm. Designed with a 1-m neutron imaging line of sight, we achieve about 4:1 magnification and 500-µm axial spatial resolution. The baseline inertial confinement fusion concept at Sandia is magnetized liner inertial fusion, which nominally creates a 1-cm line source of neutrons. ODIN was designed to determine the size, shape, and location of the neutron producing region, furthering the understanding of compression quality along the cylindrical axis of magnetized liner implosions. Challenges include discriminating neutrons from hard x-rays and gammas with adequate signal-to-noise in the 2 × 1012 deuterium-deuterium (DD) neutron yield range, as well as understanding the point spread function of the imager to various imaging detectors (namely, CR-39). Modeling efforts were conducted with MCNP6.1 to determine neutron response functions for varying configurations in a clean DD neutron environment (without x-rays or gammas). Configuration alterations that will be shown include rolled-edge slit orientation and slit width, affecting the resolution and response function. Finally, the experiment to determine CR-39 neutron sensitivity, with and without a high density polyethylene (n, p) converter, an edge spread function, and resolution will be discussed.

3.
Rev Sci Instrum ; 85(11): 11E617, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430363

ABSTRACT

A methodology for obtaining empirical curves relating absolute measured scintillation light output to beta energy deposited is presented. Output signals were measured from thin plastic scintillator using NIST traceable beta and gamma sources and MCNP5 was used to model the energy deposition from each source. Combining the experimental and calculated results gives the desired empirical relationships. To validate, the sensitivity of a beryllium/scintillator-layer neutron activation detector was predicted and then exposed to a known neutron fluence from a Deuterium-Deuterium fusion plasma (DD). The predicted and the measured sensitivity were in statistical agreement.

4.
Rev Sci Instrum ; 83(10): 10D913, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126916

ABSTRACT

The 350-keV Cockroft-Walton accelerator at Sandia National laboratory's Ion Beam facility is being used to calibrate absolutely a total DT neutron yield diagnostic based on the (63)Cu(n,2n)(62)Cu(ß+) reaction. These investigations have led to first-order uncertainties approaching 5% or better. The experiments employ the associated-particle technique. Deuterons at 175 keV impinge a 2.6 µm thick erbium tritide target producing 14.1 MeV neutrons from the T(d,n)(4)He reaction. The alpha particles emitted are measured at two angles relative to the beam direction and used to infer the neutron flux on a copper sample. The induced (62)Cu activity is then measured and related to the neutron flux. This method is known as the F-factor technique. Description of the associated-particle method, copper sample geometries employed, and the present estimates of the uncertainties to the F-factor obtained are given.

5.
Rev Sci Instrum ; 83(10): 10D914, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126917

ABSTRACT

We have performed absolute calibrations of a fusion-neutron-yield copper-activation diagnostic in environments that significantly attenuate and scatter neutrons. We have measured attenuation and scattering effects and have compared the measurements to Monte Carlo simulations using the Monte Carlo N-Particle code. We find that measurements and simulations are consistent within 10%.

6.
Rev Sci Instrum ; 83(10): 10D918, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23126920

ABSTRACT

A DT neutron yield diagnostic based on the reactions, (63)Cu(n,2n)(62)Cu(ß(+)) and (65)Cu(n,2n)( 64) Cu(ß(+)), has been fielded at the National Ignition Facility (NIF). The induced copper activity is measured using a NaI γ-γ coincidence system. Uncertainties in the 14-MeV DT yield measurements are on the order of 7% to 8%. In addition to measuring yield, the ratio of activities induced in two, well-separated copper samples are used to measure the relative anisotropy of the fuel ρR to uncertainties as low as 5%.