Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
J Med Eng Technol ; 46(6): 433-447, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36001089

ABSTRACT

This paper provides an overview of the usability engineering process and relevant standards informing the development of medical devices, together with adaptations to accommodate situations such as global pandemics where use of traditional face-to-face methods is restricted. To highlight some of those adaptations, a case study of a project developing a novel electronic rehabilitation device is referenced, which commenced in November 2020 amidst the COVID-19 pandemic. The Sheffield Adaptive Patterned Electrical Stimulation (SHAPES) project, led by Sheffield Teaching Hospitals NHS Foundation Trust (STH), aimed to design, manufacture and trial an intervention for use to treat upper arm spasticity after stroke. Presented is an outline and discussion of the challenges experienced in developing the SHAPES health technology intended for at-home use by stroke survivors and in implementing usability engineering approaches. Also highlighted, are the benefits that arose, which can offer easier involvement of vulnerable users and add flexibility in the ways that user feedback is sought. Challenges included: restricted travel; access to usual prototyping facilities; social distancing; infection prevention and control; availability of components; and changing work pressures and demands. Whereas benefits include: less travel; less time commitment; and greater scope for participants with restricted mobility to participate in the process. The paper advocates a more flexible approach to usability engineering and outlines the onward path for development and trialling of the SHAPES technology.


Subject(s)
COVID-19 , Stroke Rehabilitation , Stroke , Arm , Humans , Pandemics , Stroke/therapy
2.
J Med Eng Technol ; 45(6): 457-472, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34016021

ABSTRACT

Non-invasive ventilation (NIV) is assisted mechanical ventilation delivered via a facemask for people with chronic conditions that affect breathing. Mass-produced masks are available for both the adult and paediatric markets but masks that fit well are difficult to find for children who are small or have asymmetrical facial features. A good fit between the mask and the patient's face to minimise unintentional air leakage is essential to deliver the treatment effectively. We present an innovative use of 3D assessment and manufacturing technologies to deliver novel custom-made facemasks for children for whom a well-fitting standard mask is not available. This paper aims to describe the processes undertaken to investigate and compare currently available technologies for 3D scanning children and to explore the design of a system for creating custom-made paediatric NIV masks within the NHS. The paper therefore considers not only the quality and accuracy of the data, but also other factors such as the time and ease of process. Searches for all currently available scanning technologies were made. Photogrammetry image stitch using a smartphone and a digital camera, and two structured light scanners were selected and compared in the laboratory, in discussion with user groups, and in adult volunteers. Using the processes described, it became apparent that the optimal 3D scanning system for this purpose was the handheld structured light scanner. This option offered both superior accuracy and convenience and was more cost effective.


Subject(s)
Noninvasive Ventilation , Adult , Child , Humans , Masks , Photogrammetry , Printing, Three-Dimensional , Respiration, Artificial
3.
Pediatr Crit Care Med ; 22(6): 561-571, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33729732

ABSTRACT

OBJECTIVES: Recently, several adult trials have investigated the potential benefit of high-dose vitamin C therapy in critically ill patients. In pediatric patients, little is known on the efficacy, safety, and risk of high-dose vitamin C therapy. We aimed to review the efficacy and potential harm associated with high-dose vitamin C treatment. DATA SOURCES: We searched MEDLINE, EMBASE, Cochrane Library, and National Institute of Health Clinical Trials Register. STUDY SELECTION: We included studies in neonatal and pediatric patients who received IV or intra-arterial high-dose vitamin C (ascorbic acid) defined as greater than or equal to 75 mg/kg/d. DATA EXTRACTION: Two independent investigators screened articles and extracted data. DATA SYNTHESIS: We found 1,364 articles, assessed 193 full texts for eligibility, and identified 12 eligible studies. These studies included 855 patients, with 194 receiving high-dose vitamin C. The age of patients who received high-dose vitamin C ranged from 2 hours after delivery to 8.4 years (median 2.4 yr), and the vitamin C dose ranged from 100 to 1,500 mg/kg/d (median 260.5 mg/kg/d). Four studies were double-blind randomized controlled trials, and no clinical efficacy outcome was reported in favor of or against vitamin C. Furthermore, no adverse event or signal of harm was reported with high-dose vitamin C. CONCLUSIONS: In 12 studies with 194 children treated with parenteral high-dose vitamin C, there was no evidence of clinical efficacy or inferior clinical outcomes in double-blind randomized controlled trials, and no reported harmful effects. These findings justify further investigations of this treatment in children.


Subject(s)
Ascorbic Acid , Adult , Ascorbic Acid/adverse effects , Child , Child, Preschool , Humans , Infant, Newborn , Randomized Controlled Trials as Topic
4.
Article in English | MEDLINE | ID: mdl-32909466

ABSTRACT

The HeadUp collar (previously known as the Sheffield Support Snood) provides support for neck weakness caused by amyotrophic lateral sclerosis (ALS) and has shown to be superior to alternative options in a small cohort of patients from one single center. Here we report the assessment of the HeadUp collar in a larger cohort of patients, exploring the use in other neurological conditions and expanding to other centers across the UK and Ireland. An interventional cross-sectional study design was implemented to investigate the usability and acceptability of the HeadUp collar. A total of 139 patients were recruited for the study, 117 patients had a diagnosis of ALS and 22 patients presented with neck weakness due to other neurological conditions. Participants were assessed at baseline, fitted a HeadUp collar and followed-up one month later. The performance of the HeadUp collar was rated favorably compared to previously worn collars in terms of the ability to eat, drink and swallow. Findings suggest that the collar also permitted a more acceptable range of head movements whilst maintaining a good level of support. We conclude that the HeadUp collar is a suitable option for patients with neck weakness due to ALS and other neurological conditions.


Subject(s)
Amyotrophic Lateral Sclerosis , Braces , Amyotrophic Lateral Sclerosis/complications , Amyotrophic Lateral Sclerosis/therapy , Cross-Sectional Studies , Humans , Ireland , Neck
5.
J Med Eng Technol ; 44(5): 213-223, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32597695

ABSTRACT

Non-invasive ventilation (NIV) is assisted mechanical ventilation delivered via a facemask for people with chronic conditions that affect breathing. NIV is most commonly delivered via an interface (mask) covering the nose (nasal mask) or the nose and mouth (oronasal mask). The number of children in the UK requiring NIV is currently estimated to be around 5000. Mass-produced masks are available for both the adult and paediatric markets but masks that fit well are difficult to find for children who are small or have asymmetrical facial features. A good conforming fit between the mask and the patient's face to minimise unintentional air leakage is essential to deliver the treatment effectively; most ventilators will trigger an alarm requiring action if such leakage is detected. We present an innovative use of 3D scanning and manufacturing technologies to deliver novel mask-face interfaces to optimise mask fit to the needs of individual patients. Ahead of planned user trials with paediatric patients, the project team trialled the feasibility of the process of creating and printing bespoke masks from 3D scan data and carried out testing of the masks in adult volunteers to select the strongest design concept for the paediatric trial. The evaluation of the process of designing a bespoke mask from scan data, arranging for its manufacture and carrying out user testing has been invaluable in gaining knowledge and discovering the pitfalls and timing bottlenecks in the processes. This allowed the team to iteratively refine the techniques and methods involved, informing user trials later on in the project. It has also provided indicative cost estimates for 3D printed mask prototype components which are useful in project decision making and trial planning. The value of the process extends to considerations for future implementation of the process within a clinical pathway.


Subject(s)
Masks , Noninvasive Ventilation/instrumentation , Adult , Child , Equipment Design , Feasibility Studies , Healthy Volunteers , Humans , Printing, Three-Dimensional
6.
Proc Inst Mech Eng H ; 233(1): 58-67, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30044175

ABSTRACT

Modern urinary catheter-to-leg-bag systems suffer from a number of shortcomings. Drainage tubing of current urinary leg bags is perceived as unnecessarily bulky compared to the indwelling catheters to which it is connected, and catheter designs are prone to the formation of biofilms, leading ultimately to encrustation and blocking. We used analytical and experimental engineering methodologies, aligned with current international (International Standards Organisation) and European standards, to optimise drainage tube size and flow efficiency and characterise tube kinking behaviour. Using computational fluid dynamics, we studied the influence of modern Foley catheter design on urodynamics and explored its potential influence on biofilm formation and encrustation. Results indicate that tubing diameters could be reduced by 40%-50% and still satisfy current International Standards Organisation flow rate standards for leg bags; this might also reduce the likelihood of tube kinking. The computational study showed how current catheter design may promote the development of lower velocity recirculating flows and high shear in proximity of regions known to be affected by bacterial adhesion and biofilm formation. If confirmed, these findings will give manufacturers greater flexibility to develop less obtrusive and more encrustation-resistant products for end users.


Subject(s)
Engineering , Equipment Design/methods , Urinary Catheters , Computer-Aided Design , Consumer Behavior
7.
Ergonomics ; 61(2): 329-338, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28697682

ABSTRACT

PURPOSE: Identify location and intensity of discomfort experienced by healthy participants wearing cervical orthoses. METHOD: Convenience sample of 34 healthy participants wore Stro II, Philadelphia, Headmaster, and AspenVista® cervical orthoses for four-hour periods. Participants reported discomfort level (scale 0-6) and location. RESULTS: Participants reported mean discomfort for all orthoses over the four-hour test between 'a little discomfort' and 'very uncomfortable' (mean discomfort score = 1.64, SD = 1.50). Seven participants prematurely stopped tests due to pain and six reported maximum discomfort scores. Significant linear increase in discomfort with duration of wear was found for all orthoses. Significantly less discomfort was reported with Stro II than Headmaster and Philadelphia. Age correlated with greater perceived discomfort. Orthoses differed in the location discomfort was experienced. CONCLUSION: Existing cervical orthoses cause discomfort influenced by design and duration of wear with orthoses' design the more significant factor. This work informed the design of a new orthosis and future orthoses developments. Practitioner Summary: The purpose of this study was to gain greater knowledge about the discomfort caused by wearing of existing neck orthoses in order to inform the design and development of a new neck orthosis. This study gathers empirical data from a surrogate population and concludes that orthosis design is more influential than the duration of wear.


Subject(s)
Braces/adverse effects , Pain/etiology , Adult , Age Factors , Equipment Design , Esthetics , Female , Humans , Male , Middle Aged , Neck , Pressure/adverse effects , Time Factors , Young Adult
8.
Article in English | MEDLINE | ID: mdl-26915274

ABSTRACT

Current practice and guidelines recommend the use of neck orthoses for people with amyotrophic lateral sclerosis (ALS) to compensate for neck weakness and to provide surrogate neck control. However, available options are frequently described by patients as restrictive and unsuitable and there was a need for a new device that addressed the needs of people with ALS. This project utilized a co-design process to develop a new neck orthosis that was more flexible yet supportive. Following development of a prototype device, a mixed methods cohort study was undertaken with patients and carers, in order to evaluate the new orthosis. Twenty-six patients were recruited to the study, with 20 of these completing all phases of data collection. Participants described the impact of neck weakness on their life and limitations of existing supports. Evaluation of the new orthosis identified key beneficial features: notably, increased support while providing a greater range of movement, flexibility of use, and improved appearance and comfort. In conclusion, the results of this evaluation highlight the value of this alternative option for people with ALS, and potentially other patient groups who require a neck orthosis.


Subject(s)
Amyotrophic Lateral Sclerosis/complications , Muscle Weakness/etiology , Muscle Weakness/rehabilitation , Neck/physiopathology , Orthotic Devices , Adolescent , Adult , Deglutition/physiology , Eating/physiology , Female , Humans , Male , Middle Aged , Motor Neuron Disease/complications , Respiration , Surveys and Questionnaires , Young Adult
9.
Clin Biomech (Bristol, Avon) ; 32: 201-6, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26673978

ABSTRACT

BACKGROUND: This study aimed at quantifying the biomechanical features of the Sheffield Support Snood, a cervical orthosis specifically designed for patients with neck muscle weakness. The orthosis is designed to be adaptable to a patient's level of functional limitation using adjustable removable supports, which contribute support and restrict movement only in desired anatomical planes. METHODS: The snood was evaluated along with two commercially available orthoses, the Vista and Headmaster, in a series of flexion, extension, axial-rotation and lateral flexion movements. Characterization was performed with twelve healthy participants with and without the orthoses. Two inertial-magneto sensors, placed on the forehead and sternum, were used to quantify the neck's range of motion. FINDINGS: In its less supportive configuration, the snood was effective in limiting movements to the desired planes, preserving free movement in other planes. The Headmaster was only effective in limiting flexion. The range of motion achieved with the snood in its rigid configuration was equivalent (P>0.05, effect size<0.4) to that achieved with the Vista, both in trials performed reaching the maximum amplitude (range of motion reduction: 25%-34% vs 24%-47%) and at maximum speed (range of motion reduction: 24%-29% vs 25%-43%). INTERPRETATION: The Sheffield Support Snood is effectively adaptable to different tasks and, in its most supportive configuration, offers a support comparable to the Vista, but providing a less bulky structure. The chosen method is suitable for the assessment of range of motions while wearing neck orthoses and is easily translatable in a clinical context.


Subject(s)
Braces , Cervical Vertebrae/physiopathology , Muscle Weakness/physiopathology , Neck/physiopathology , Orthotic Devices , Adult , Biomechanical Phenomena , Female , Humans , Male , Movement/physiology , Orthopedic Equipment , Range of Motion, Articular/physiology , Rotation , Young Adult
10.
J Wound Ostomy Continence Nurs ; 42(2): 176-82, 2015.
Article in English | MEDLINE | ID: mdl-25734462

ABSTRACT

PURPOSE: The purpose of the study was to explore participants' experiences of urinary incontinence and leg bag use in order to identify priorities for product redesign. SUBJECTS AND SETTING: Twenty-nine leg bag users and 5 carers and healthcare professionals participated in the study. They were recruited through a UK hospital Trust and a UK-wide charity for people with bladder and bowel control problems. DESIGN: The study employed a descriptive design with qualitative and quantitative elements to determine current experiences with urinary drainage leg bags and identify potential ways to improve their design. METHODS: Data collection occurred during semistructured face-to-face and telephone semistructured interviews. RESULTS: Thematic analysis revealed that leg bag design and performance influenced users' relationships, confidence, and ability to socialize. The most significant issues related to leg bag use were reliable functioning without leakage, secure positioning, and discretion when worn under clothing. All participants reported having experienced significant urine leakage due to usability issues with the leg bags. CONCLUSIONS: Respondents identified a number of design issues with current leg bags that need to be addressed to improve the ease of use and overall experience when using leg bags for containing urinary output. The findings have been used to define design requirements for further development of leg bags and their component parts.


Subject(s)
Drainage/instrumentation , Equipment Design/standards , Leg , Urinary Catheterization/instrumentation , Urinary Incontinence/nursing , Urinary Incontinence/therapy , Female , Humans , Male
11.
J Med Eng Technol ; 39(7): 382-7, 2014.
Article in English | MEDLINE | ID: mdl-26415684

ABSTRACT

This paper describes and discusses the role of unmet needs in the innovation of new medical technologies using the National Institute for Health Research Devices for Dignity (D4D) Healthcare Technology Co-operative as a case study. It defines an unmet need, providing a spectrum of classification and discusses the benefits and the challenges of identifying unmet need and its influence on the innovation process. The process by which D4D has captured and utilized unmet needs to drive technology innovation is discussed and examples given. It concludes by arguing that, despite the challenges, defining and reviewing unmet need is a fundamental factor in the success of medical technology innovation.


Subject(s)
Biomedical Technology/instrumentation , Equipment and Supplies , Inventions , Needs Assessment/organization & administration , Technology Assessment, Biomedical/methods , Technology Assessment, Biomedical/organization & administration , United Kingdom
12.
J Med Eng Technol ; 39(7): 441-7, 2014.
Article in English | MEDLINE | ID: mdl-26415828

ABSTRACT

The paper provides an introduction to the regulatory landscape affecting a particular category of medical technology, namely standalone software-sometimes referred to as 'software as a medical device'. To aid the reader's comprehension of an often complex area, six case studies are outlined and discussed before the paper continues to provide detail of how software with a medical purpose in its own right can potentially be classified as a medical device. The reader is provided an appreciation of how to go about classifying such software and references to support the developer new to the field in locating detailed regulatory support documents and contact points for advice.


Subject(s)
Device Approval/legislation & jurisprudence , Equipment and Supplies/classification , Government Regulation , Software/legislation & jurisprudence , Software/trends , Europe , Internationality , Software/classification
13.
J Med Eng Technol ; 39(7): 404-10, 2014.
Article in English | MEDLINE | ID: mdl-26453038

ABSTRACT

This paper presents the Head-Up project, that aims to provide innovative head support to help improve posture, relieve pain and aid communication for people living with progressive neck muscle weakness. The initial focus is motor neurone disease. The case study illustrates collaborative, interdisciplinary research and new product development underpinned by participatory design. The study was initiated by a 2-day stakeholder workshop followed by early proof-of-concept modelling and patient need evidence building. The work subsequently led to a successful NIHR i4i application funding a 24-month iterative design process, patenting, CE marking and clinical evaluation. The evaluation has informed amendments to the proposed design refered to here as the Sheffield Support Snood (SSS). The outcome positively demonstrates use and performance improvements over current neck orthoses and the process of multidisciplinary and user engagement has created a sense of ownership by MND participants, who have since acted as advocates for the product.


Subject(s)
Braces , Motor Neuron Disease/rehabilitation , Muscle Weakness/rehabilitation , Patient Care Team/organization & administration , Patient Participation/methods , Prosthesis Design/methods , Biomedical Technology/methods , Biomedical Technology/organization & administration , Humans , Neck Muscles , Needs Assessment/organization & administration , Patient-Centered Care/methods , Patient-Centered Care/organization & administration , Technology Assessment, Biomedical/methods , Technology Assessment, Biomedical/organization & administration , United Kingdom
14.
J Med Eng Technol ; 39(7): 434-40, 2014.
Article in English | MEDLINE | ID: mdl-26453040

ABSTRACT

Urinary incontinence, the leakage of urine, is a common condition, which can have a significant impact on a patient's quality-of-life. Incontinence may arise as a consequence of a weakness of the urinary sphincter or bladder dysfunction, usually over-activity. Incontinence therapies occupy a large proportion of the healthcare budget. As no single device to manage incontinence is appropriate for all situations, a diverse range of products are available on the market and the development of improved products based on fundamental designs has been slow. This review highlights some of the key issues of continence care and describes the current technology and recent developments involved in the diagnosis, assessment and treatment of incontinence, along with the strengths and limitations of these methods. These issues are imperative to address if improved technology is to be developed.


Subject(s)
Diagnostic Techniques, Urological/trends , Electric Stimulation Therapy/trends , Kidney Function Tests/trends , Urinalysis/trends , Urinary Incontinence/diagnosis , Urinary Incontinence/therapy , Biomedical Technology/trends , Female , Humans , Male , Suburethral Slings/trends
15.
Neurourol Urodyn ; 31(4): 429-36, 2012 Apr.
Article in English | MEDLINE | ID: mdl-21905087

ABSTRACT

A good idea does not inevitably lead to successful innovation; it needs additional "drivers" and coherent activity of a specialized team. The initial idea needs proof-of-concept and prototype testing. Alongside, market review must anticipate future need and competitors, and ensure that no current patents are infringed. The likelihood that reimbursement will be secured and that health systems will "adopt" the device has to be considered. Intellectual property (IP) protection is needed to maintain sole rights to exploit the core concept. Non-disclosure agreements (NDA) should be put in place, and commercial considerations should be remembered before any disclosure in the public domain, including publications. Prospective business partners will review the concept from many perspectives, including stage of device development, effective IP protection, any clinical trial evidence, and whether the device aligns with their business strategy. Royalties arising from sales of a marketed device are distributed to all parties contributing to its development; the party bearing the greater financial burden of developing the final product will gain the greater share of royalties. The innovator's employer will have a call on proceeds if the idea arose in the course of employment. All stages of development require fastidious documentation to meet requirements of the regulatory authorities responsible for permitting use in patients. Specific regulatory requirements depend on which region(s) of the world the device will be marketed in. This review explains all stages of the innovation pathway from concept to adoption, giving practical advice and signposting expertise relevant to each stage.


Subject(s)
Equipment and Supplies , Diffusion of Innovation , Humans , Intellectual Property
16.
Foot Ankle Surg ; 17(3): 108-12, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21783067

ABSTRACT

BACKGROUND: The study compared three-dimensional (3D) changes in geometry of the first metatarsal following scarf osteotomy performed on standardised Sawbone® models by consultant foot and ankle surgeons. The study considered the inter-surgeon variances in interpretation and performance of the scarf osteotomy with respect to intra-surgeon variances. METHODS: The analysis used an accurate digitising system to measure and record points on the Sawbone® models in 3D space. Computer software performed vector analysis to calculate 3D rotations and translations of the first metatarsal head as well as the inter-metatarsal angle. Bone cut lengths and displacements were measured using a digital Vernier caliper. One surgeon performed the osteotomy 10 times to form an intra-surgeon control dataset, while 10 different surgeons each did one scarf osteotomy to form an inter-surgeon test dataset. RESULTS: Both surgical groups produced reductions in the 3D inter-metatarsal angle with non-significant differences between the groups (p>0.05). In contrast, the test group demonstrated highly significant (p=0.000) greater variance compared with the control dataset for all of the variables associated with surgical technique. In addition, there were highly significant (p=0.02 and 0.002) greater variances in the interpretation of the degree to which the metatarsal head should be translated medially (X) and inferiorly (Z). There was also a significant (p=0.001) increase in variances in the rotations about the dorsi/plantar-flexion (X) axis. The only significant differences (all p=0.000) attributable solely to differences in mean values were in proximal-distal (Y) translation, pronation (Y) rotation and medial (Z) rotation. The test group applied greater medial and plantar-flexion rotation of the metatarsal head than the control surgeon and significantly less (p=0.000) shortening of the first metatarsal than the control surgeon. CONCLUSIONS: The results of this geometric study demonstrate the versatility of the scarf osteotomy. As a result of the multi-planar nature of the osteotomy, there is a potential risk of producing unintended rotational mal-unions in all three planes. These rotational mal-unions may account for some of the poorer outcomes documented within the literature.


Subject(s)
Hallux Valgus/surgery , Osteotomy/methods , Humans , Metatarsophalangeal Joint/pathology , Metatarsophalangeal Joint/surgery , Models, Anatomic , Observer Variation , Osteotomy/statistics & numerical data
17.
Foot Ankle Int ; 29(6): 606-12, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18549758

ABSTRACT

BACKGROUND: This study evaluates and compares three-dimensional (3-D) changes in geometry of the first metatarsal (MT1) independent of soft tissue corrections of 5 common osteotomies: three distal (Chevron, Mitchell, and Wilson), one proximal (Stephens basal), and one combined proximal/distal (Scarf), using standardized synthetic bone models. MATERIALS AND METHODS: A digitizing system was used to measure and record points on the synthetic bone models in 3-D space. Computer vector analysis calculated 3-D rotations and translations of the MT1 head plus the conventional intermetatarsal angle (IMA) and distal metatarsal articular angle (DMAA). RESULTS: The Wilson and Mitchell's osteotomies produced significant shortening (p < 0.001) in contrast to the three other osteotomies. All the osteotomies produced a reduction in the 3-D IMA. The Scarf and Stephens basal osteotomies reduced the DMAA. All of the osteotomies resulted in lateral translations and depression of the MT1 head. While there were no significant (p > 0.05) translational differences between the Scarf and Stephens basal osteotomies, there were rotational differences, with the Stephens basal producing significantly more plantar flexion (p = 0.000) and pronation (p < 0.001) than the Scarf. CONCLUSION: This geometric study indicated many of the MT1 head changes following metatarsal osteotomy to be out-of-plane translational and multiplanar rotations which cannot be determined using AP radiographs alone. CLINICAL RELEVANCE: We advocate judicious choice of osteotomy to achieve the desired correction of hallux valgus in each individual.


Subject(s)
Hallux Valgus/pathology , Hallux Valgus/surgery , Imaging, Three-Dimensional , Metatarsal Bones/pathology , Metatarsal Bones/surgery , Osteotomy/methods , Body Weights and Measures , Hallux Valgus/diagnostic imaging , Humans , Metatarsal Bones/diagnostic imaging , Metatarsophalangeal Joint/diagnostic imaging , Metatarsophalangeal Joint/pathology , Models, Biological , Radiography , Reproducibility of Results
18.
Clin Orthop Relat Res ; 442: 13-20, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16394733

ABSTRACT

Previous investigation of a cost-effective virtual reality arthroscopic training system, the Sheffield Knee Arthroscopy Training System (SKATS), indicated the desirability of including haptic feedback. A formal task analysis confirmed the importance of knee positioning as a core skill for trainees learning to navigate the knee arthroscopically. The system cost and existing limb interface, which permits knee positioning, would be compromised by the addition of commercial active haptic devices available currently. The validation results obtained when passive haptic feedback (resistance provided by physical structures) is provided indicate that SKATS has construct, predictive and face validity for navigation and triangulation training. When tested using SKATS, experienced surgeons (n = 11) performed significantly faster, located significantly more pathologies, and showed significantly shorter arthroscope path lengths than a less experienced surgeon cohort (n = 12). After SKATS training sessions, novices (n = 3) showed significant improvements in: task completion time, shorter arthroscope path lengths, shorter probe path lengths, and fewer arthroscope tip contacts. Main improvements occurred after the first two practice sessions, indicating rapid familiarization and a training effect. Feedback from questionnaires completed by orthopaedic surgeons indicates that the system has face validity for its remit of basic arthroscopic training.


Subject(s)
Arthroscopy , Computer-Assisted Instruction , Education, Medical/methods , Knee Joint/surgery , User-Computer Interface , Analysis of Variance , Clinical Competence , Computer Simulation , Image Processing, Computer-Assisted , Posture , Surgery, Computer-Assisted , Surveys and Questionnaires , Task Performance and Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...