Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Neuroimaging ; 11(4): 401-5, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11677880

ABSTRACT

Cerebral vasoreactivity can be studied with transcranial Doppler (TCD) by monitoring CO2-induced middle cerebral artery (MCA) velocity changes. Expected MCA mean velocity (Vm) changes due to changes in end-expiratory CO2 (EE-CO2) are established, but reactivity of common carotid artery (CCA) volume flow rate (VFR) has not been extensively reported. The authors assess the relationship between MCA Vm, CCA VFR, and EE-CO2. Ten normal individuals without cerebrovascular disease and with CCA diameters of more than 3.0 mm were studied. CCA VFR was obtained by Color Velocity Imaging Quantification and Ipsilateral MCA Vm by standard TCD methods. Each side was studied before, during, and after inhalation of 5% CO2. EE-CO2, blood pressure, and pulse rate were monitored. Four women and 6 men with mean age of 36 years were included. Significant correlations between MCA Vm and EE-CO2, CCA VFR and EE-CO2, and MCA Vm and CCA VFR were found. MCA Vm and CCA VFR increased 5.2% and 4.3% per mm Hg increase in EE-CO2, respectively. MCA Vm increased 0.3 cm/s for each ml/min increase in CCA VFR. In normal individuals, there is a direct correlation between MCA Vm, CCA VFR, and EE-CO2. Measurement of CCA VFR changes during CO2 inhalation may be an alternative method to estimate cerebral vasoreactivity when the MCA velocity cannot be obtained because of inadequate acoustic temporal windows.


Subject(s)
Carbon Dioxide/administration & dosage , Carotid Arteries/diagnostic imaging , Carotid Arteries/physiology , Cerebral Arteries/diagnostic imaging , Cerebral Arteries/physiology , Ultrasonography, Doppler, Transcranial , Administration, Inhalation , Adult , Blood Flow Velocity , Female , Hemodynamics , Humans , Male
2.
J Neuroimaging ; 8(3): 175-7, 1998 Jul.
Article in English | MEDLINE | ID: mdl-9664857

ABSTRACT

Transcranial Doppler ultrasonography (TCD) allows evaluation of blood-flow velocity in intracranial arteries detection and monitoring of vasospasm in patients with subarachnoid hemorrhage. Spectral Doppler artifacts can affect TCD data. A 1-month series of TCD findings showed marked fluctuation in blood-flow velocity values in both the middle and anterior cerebral arteries of a patient with subarachnoid hemorrhage. A mirror-image artifact of the Doppler fast Fourier transform velocity spectrum resulted in erroneous interpretation of higher flow velocity in certain vessels. This artifact may cause misinterpretation of TCD flow-velocity data and lead to improper diagnosis of the condition and treatment of patients.


Subject(s)
Aneurysm, Ruptured/diagnostic imaging , Intracranial Aneurysm/diagnostic imaging , Ischemic Attack, Transient/diagnostic imaging , Subarachnoid Hemorrhage/diagnostic imaging , Ultrasonography, Doppler, Transcranial , Artifacts , Blood Flow Velocity/physiology , Female , Humans , Middle Aged , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...