Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Invest Ophthalmol Vis Sci ; 65(12): 12, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-39377736

ABSTRACT

Purpose: The purpose of this study was to determine the minimum number of orthonormal basis functions, applying Principal Component Analysis (PCA), to represent the most wavefront aberrations at different accommodation stages. The study also aims to generate synthetic wavefront data using these functions. Methods: Monocular wavefront data from 191 subjects (26.15 ± 5.56 years old) were measured with a Hartmann-Shack aberrometer, simulating accommodation from 0 diopters (D) to 5 D in 1 D steps. The wavefronts for each accommodative demand were rescaled for different pupil sizes: 4.66, 4.76, 4.40, 4.09, 4.07, and 3.68 mm. PCA was applied to 150 wavefront parameters (25 Zernike coefficients × 6 accommodation levels) to obtain eigenvectors for dimensional reduction. A total of 49 eigenvectors were modeled as a sum of 2 multivariate Gaussians, from which 1000 synthetic data sets were generated. Results: The first 49 eigenvectors preserved 99.97% of the original data variability. No significant differences were observed between the mean values and standard deviation of the generated and original 49 eigenvectors (two one-sided test [TOST], P > 0.05/49) and (F-test, P > 0.05/49), both with Bonferroni correction. The mean values of the generated parameters (1000) were statistically equal to those of the original data (TOST, P > 0.05/150). The variability of the generated data was similar to the original data for the most important Zernike coefficients (F-test, P > 0.05/150). Conclusions: PCA significantly reduces the dimensionality of wavefront aberration data across 6 accommodative demands, reducing the variable space by over 66%. The synthetic data generated by the proposed wavefront model for accommodation closely resemble the original clinical data.


Subject(s)
Aberrometry , Accommodation, Ocular , Corneal Wavefront Aberration , Models, Statistical , Humans , Accommodation, Ocular/physiology , Adult , Female , Male , Corneal Wavefront Aberration/physiopathology , Young Adult , Principal Component Analysis , Refraction, Ocular/physiology , Adolescent
2.
Curr Eye Res ; : 1-10, 2024 Jul 14.
Article in English | MEDLINE | ID: mdl-39004896

ABSTRACT

PURPOSE: To evaluate the repeatability of the Zernike coefficients in healthy eyes when monocular accommodation was stimulated at different vergences demands. METHODS: A total of 36 right eyes from healthy volunteers were prospectively and consecutively recruited for this study. Wavefront aberrometry was conducted to objectively characterize the ocular optical quality during accommodation, from the individual's far point to a 5 D accommodation demand in steps of 0.5 D. The repeatability of Zernike coefficients up to the fourth order was assessed by calculating the within-eye repeatability (Sw), the coefficient of repeatability (CR), the coefficient of variation (CV), and the intraclass correlation coefficient (ICC) as an indicator of measurement reliability. RESULTS: Correlation among repeated measurements showed high reliability (ICC > 0.513) for all parameters measured except some fourth-order Zernike coefficients, C(4, -4) (ICC < 0.766), C(4, -2) (ICC < 0.875), C(4, 2) (ICC < 0.778) and C(4, 4) (ICC < 0.811). Greater repeatability and less variability were obtained for high-order Zernike coefficients (CR < 0.154), although an increase in CR in the coefficients analyzed was observed with increasing accommodative demand. No clear trend was evident in CV; however, it was observed that the low-order Zernike coefficients exhibit lower CV (CV < 1.93) compared to the high-order Zernike coefficients (CV > 0). CONCLUSIONS: The reliability of Zernike coefficients up to the fourth order in healthy young individuals demonstrated a strong consistency in measuring terms up to the fourth order, with more variability observed for high-order terms. The Zernike coefficients up to the third order exhibited the highest level of repeatability.

3.
Curr Eye Res ; 49(6): 671-681, 2024 06.
Article in English | MEDLINE | ID: mdl-38379315

ABSTRACT

PURPOSE: Accommodation mainly affects the lens, a structure of the eyeball that degrades with age. The aim of this work was to study the morphological changes of different ocular structures during accommodation, both in the anterior pole and the posterior pole, which may also be involved in the accommodation process. METHODS: The study will be carried out by stimulating accommodation through lenses of -1.00, -3.00 and -5.00 D starting from the spherical equivalent (M) of each participant in different age groups, from 18 to 66 years. To obtain the M value, aberrometry was achieved, and retinal optical coherence tomography and anterior pole tomography were performed to evaluate the possible structural modifications (central and peripheral), while accommodation was progressively stimulated. RESULTS: It showed that as the accommodative demand increased, morphological changes were produced in retinal thickness, both in the central and peripheral retina, in all age groups. A thinning of the retina was observed in the central 3 mm, while significant progressive thickening was observed closer to the periphery (up to 6 mm from the fovea) as the required accommodative power increased. A decrease in the anterior chamber depth (ACD) and anterior chamber volume (ACV) was observed with increasing lens power. CONCLUSION: Structural changes were observed in the central and peripheral retina, as well as in the ACD and ACV, while progressively greater accommodation was stimulated, showing that these structures were modified in the accommodation process even in advanced presbyopes.


Subject(s)
Accommodation, Ocular , Aging , Anterior Chamber , Retina , Tomography, Optical Coherence , Humans , Accommodation, Ocular/physiology , Tomography, Optical Coherence/methods , Adult , Middle Aged , Aged , Young Adult , Anterior Chamber/diagnostic imaging , Retina/diagnostic imaging , Male , Adolescent , Aging/physiology , Female , Lens, Crystalline/diagnostic imaging , Lens, Crystalline/physiology , Lens, Crystalline/anatomy & histology , Refraction, Ocular/physiology
4.
Ophthalmic Physiol Opt ; 43(4): 885-897, 2023 07.
Article in English | MEDLINE | ID: mdl-37073817

ABSTRACT

PURPOSE: To assess changes in visual function and optical and tear film quality in computer users. METHODS: Forty computer workers and 40 controls were evaluated at the beginning and end of a working day. Symptoms were assessed using the Quality of Vision questionnaire (QoV), 5-item Dry Eye Questionnaire (DEQ-5) and Symptom Assessment in Dry Eye version II (SANDE II). Tear film quality was evaluated using the Medmont E300 dynamic corneal topography tool to measure the tear film surface quality (TFSQ), TFSQ area and auto tear break-up time (TBUT). Optical quality was assessed by measuring high, low and total ocular aberrations with a Hartmann-Shack wavefront sensor. Visual performance was assessed by measuring photopic and mesopic visual acuity, photopic and mesopic contrast sensitivity and light disturbance. RESULTS: Poorer DEQ-5, QoV and SANDE II scores were obtained in computer workers at the end of the working day compared with controls (p ≤ 0.02). Computer workers exhibited a higher (worse) TFSQ and TFSQ area at visit 2 compared with visit 1 (p ≤ 0.04), while no significant differences in TBUT (p = 0.19) or ocular aberrations were observed (p ≥ 0.09). Additionally, both light disturbance (p ≤ 0.04) and mesopic and photopic contrast sensitivity worsened at several spatial frequencies (p ≤ 0.04) throughout the working day in computer workers, while visual acuity remained unchanged (p ≥ 0.07). In contrast, control subjects exhibited no decrease in any variable during the day. CONCLUSIONS: While visual acuity remained unchanged, several aspects of visual function and quality of vision decreased over a day of computer use. These changes were accompanied by greater dry eye symptoms and tear film changes, which are likely to have played a fundamental role. The present study provides insight into new metrics to assess digital eye strain.


Subject(s)
Dry Eye Syndromes , Vision, Ocular , Humans , Tears , Visual Acuity , Corneal Topography , Dry Eye Syndromes/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL