Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Eur Arch Otorhinolaryngol ; 281(2): 737-742, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37548705

ABSTRACT

PURPOSE: The assessment of necrotizing external otitis requires a high index of suspicion by the attending physician. The purpose of the study is to determine the accuracy of parameters available at the Emergency Department for the diagnosis of this pathology. METHODS: Retrospective diagnostic accuracy study. Patients consulting at the Emergency Department for longstanding ear swelling, severe otalgia, and failure to respond to topical treatment were included. Otoscopy, physical examination, CT appearance, and analytical results were tested for the diagnosis of necrotizing external otitis, using nuclear imaging as gold standard. Sensitivity, specificity, likelihood ratios and ROC curves were calculated. RESULTS: 24 patients were included; 13 cases were necrotizing external otitis, and 11 cases were other external ear pathologies. Erythrocyte sedimentation rate and C-reactive protein levels were significantly associated with necrotizing external otitis (AUC 0.92 p < 0.001, and 0.8 p < 0.001). Positive likelihood ratios were 10.15 for values of erythrocyte sedimentation rate over 26 mm/h, and 8.25 for C-reactive protein levels over 10 mg/L. Negative likelihood ratios were 0.08 and 0.28, respectively. These results were significant. The rest of clinical and radiological parameters were less accurate. CONCLUSIONS: Erythrocyte sedimentation rate and C-reactive protein are useful parameters in the evaluation of a case of longstanding otitis with clinical suspicion of necrotizing external otitis. If any of them is elevated, the probability of suffering this condition is significantly increased. If they are within normal ranges, an alternative diagnosis should be sought.


Subject(s)
Otitis Externa , Humans , Otitis Externa/diagnosis , Otitis Externa/drug therapy , Retrospective Studies , C-Reactive Protein , Ear, External/pathology , Emergency Service, Hospital
2.
Ear Hear ; 41(6): 1648-1659, 2020.
Article in English | MEDLINE | ID: mdl-33136639

ABSTRACT

OBJECTIVES: Cochlear implants (CIs) are a well-known hearing restoration option for patients with vestibular schwannoma (VS) in cases of neurofibromatosis type-2 and, more recently, for patients with sporadic VS. One of the main limitations when performing CI during VS surgery is the capability to preserve the acoustic nerve (AN) anatomically and functionally. Significant efforts have been directed toward developing an intraoperative testing method for monitoring the AN function to determine if, after tumor removal, it is suitable for conducting stimuli delivered by a CI. However, all these methods have significant limitations, and none of them have documented diagnostic efficacy. To overcome these limitations and to obtain reliable information before CI insertion, a minimally invasive intracochlear test electrode (TE) has been recently developed. This TE has demonstrated to be suitable to test the integrity of the AN before CI in patients without any residual hearing by recording electrically evoked auditory brainstem responses (EABR). The present study constitutes the next phase of this research, which was to determine the usefulness of EABR obtained intraoperatively with the intracochlear TE after the resection of a VS and to calculate its diagnostic accuracy to assess the functionality of the AN for CI. DESIGN: This was a prospective, multicenter study of diagnostic accuracy. It was conducted in three tertiary referral centers between January 2015 and 2018. This study was designed following the Standards for Reporting of Diagnostic Accuracy Studies (STARD) statement guidelines. The STARD statement are guidelines to improve the completeness and transparency of reports of diagnostic accuracy studies. The diagnostic accuracy of the EABR evoked with the intracochlear TE after tumor removal was studied. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Patients eligible for the study were consecutive adults undergoing surgery for VS with simultaneous CI. The test under evaluation (index test) was the EABR obtained with the intracochlear TE after resection of the tumor. The reference test (gold standard) was the presence of auditory perception with the CI, defined as the presence of sound detection on an audiogram at 500, 1000, 2000, and 4000 Hz of no greater than 50 dB. In all the cases, auditory perception was verified by the presence of a positive EABR evoked with the CI. RESULTS: Twenty-one patients were included during the study period; seven patients were excluded from the diagnostic efficacy analysis due to inconclusive EABR results or absence of the gold standard to compare (they did not finally receive the CI). Thus, the outcome of the gold standard was assessed in 14 cases: 9 cases had positive EABR, all of them obtained auditory perception with the CI, and 5 cases had negative EABR, only one case had auditory perception with the CI, which constitutes the only false negative of this study. Accuracy of the TE was 93% (95% confidence interval, 66 to 100%), sensitivity 90% (95% confidence interval, 71 to 100%), specificity 100% (95% confidence interval, 100 to 100%), positive predictive value 100% (95% confidence interval, 100 to 100%), and negative predictive value 80% (95% confidence interval, 45 to 100%). CONCLUSIONS: EABR elicited with the intracochlear TE had a diagnostic accuracy of 93% for predicting auditory perception with CIs after VS removal. These results suggest that the intracochlear TE can be used intraoperatively after tumor removal to test the integrity of the AN as a useful tool to complement the surgeon's perception for decision-making regarding implantation.


Subject(s)
Cochlear Implantation , Cochlear Implants , Neuroma, Acoustic , Adult , Cochlear Nerve , Evoked Potentials, Auditory, Brain Stem , Humans , Neuroma, Acoustic/diagnosis , Neuroma, Acoustic/surgery , Prospective Studies
3.
Rev cuba ortod ; 14(2)jul.-dic.1999.
Article in Spanish | CUMED | ID: cum-24917

ABSTRACT

Se describe el estudio y tratamiento de un paciente afectado de una deformidad dentomaxilofacial consistente en una macrognasia unilateral (hipertrofia mandibular), asociada a un prognatismo mandibular, se explica la técnica quirúrgica empleada según el plan de tratamiento indicado por el equipo multidisciplinario, donde se resalta la importancia que en estos casos tiene la integración del mismo. Se exponen los resultados del tratamiento y la evolución satisfactoria del paciente que se ha mantenido inalterada después de un año de posoperatorio(AU)


Subject(s)
Humans , Male , Adult , Prognathism/diagnosis , Prognathism/surgery , Mandible/abnormalities , Oral Surgical Procedures/methods , Malocclusion, Angle Class III/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...