Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Int J Oral Maxillofac Implants ; (3): 468-472, 2024 06 21.
Article in English | MEDLINE | ID: mdl-38717353

ABSTRACT

PURPOSE: To determine the relationship between bone loss that occurs during the peri-implantitis process and variations in implant stability using resonance frequency analysis (RFA) measurement methods. MATERIALS AND METHODS: Forty selftapping implants were placed in cow ribs, and study scenarios were established according to the affected implant side and bone loss depth (n = 10 implants per group): Case 1 = bone loss on one side (vestibular); Case 2 = bone loss on two opposite sides (buccal and lingual); Case 3 = bone loss on two adjacent sides (buccal and mesial); and Case 4 = foursided bone loss (circumferential). For each group of 10 implants, first a bone loss of 0 mm was evaluated, then 4-mm defects (simulating 1/3 of bone loss) were created and evaluated, and finally 8-mm defects (simulating 2/3 of bone loss) were created and evaluated. Osteotomy measurements were made with a periodontal probe. For each implant, RFA was measured by the same operator using the Beacon system (Osstell). RESULTS: The initial implant stability quotient (ISQ) values of the 40 implants exceeded 70, reflecting an average of 73 in the buccolingual (VL) and 74.8 in the mesiodistal (MD) directions. ISQ measurements in the 10 implants in which bone dehiscence was performed on the vestibular aspect reflected a decrease in ISQ values as bone loss increased. When generating bone loss in two opposite sides (buccal and lingual), a greater decrease in ISQ values was observed when 2/3 of the implant were affected. The average VL ISQ measurement was less than 70 when at sites with 2/3 of bone loss. CONCLUSIONS: When bone loss occurs on only one side of the implant, the ISQ values decrease, but the implant maintains good stability. The same occurs when two opposite sides of the implant are affected, as the unaffected side has the least decrease in ISQ value.


Subject(s)
Alveolar Bone Loss , Dental Implants , Animals , Alveolar Bone Loss/etiology , Cattle , Peri-Implantitis/etiology , In Vitro Techniques , Resonance Frequency Analysis , Dental Implantation, Endosseous , Dental Prosthesis Retention
2.
J Funct Biomater ; 10(1)2019 Jan 11.
Article in English | MEDLINE | ID: mdl-30641939

ABSTRACT

Prescription of implant treatments is very widespread at present, mainly due to the low rate of annual loss and, to date, few studies have assessed their survival in the routine clinical practice of dentistry. The purpose of this observational study was to evaluate the effectiveness of dental implants with a calcium-phosphate surface in the daily practice of dental clinics. A multicenter, prospective, non-interventional, observational study was performed, in which three experienced practitioners (one maxillofacial and two oral surgeons) inserted implants using standard external and internal hexagon connections in adult patients requiring ≥1 osseointegrated implants to replace missing teeth. Follow-up was performed for 24 months after implant loading. Two hundred and twelve subjects were included (51.5% men), with a mean age of 51.2 ± 11.90 years, in whom 544 implants were inserted. 87.2% of the patients received 1⁻4 implants. The preferred connection system was internal hexagon (73.5%). There were nine failures, with an interval survival rate (ISR) at 24 months of 100% and a cumulative survival rate (CSR) of 98.3%. In conclusion, implants with a modified calcium-phosphate surface are associated with a high rate of survival and may be considered a method of choice in clinical practice.

3.
Rev. cuba. estomatol ; 37(3): 146-156, sep.-dic. 2000.
Article in Spanish | LILACS | ID: lil-628347

ABSTRACT

La saliva como medio diagnóstico permite reconocer las concentraciones de una serie de componentes tanto endógenos como exógenos presentes en el organismo. Gracias a los anticuerpos presentes en la saliva se pueden aplicar las nuevas tecnologías biomédicas en el diagnóstico del síndrome de inmunodeficiencia humana causado por el VIH. Este novedoso método posee numerosas ventajas con respecto a las pruebas en sangre. Se plantea información sobre los fluidos bucales, los diversos componentes con posibilidad de diagnóstico presentes en la saliva y se establecen las características de un método diagnóstico (Omni-Sal® ) aplicado a personas que padecen de alguna enfermedad del complejo bucal. Descriptores.

4.
Rev. cuba. estomatol ; 37(3): 146-56, sept.-dic. 2000. tab, graf
Article in Spanish | CUMED | ID: cum-20844

ABSTRACT

La saliva como medio diagnóstico permite reconocer las concentraciones de una serie de componentes tanto endógenos como exógenos presentes en el organismo. Gracias a los anticuerpos presentes en la saliva se pueden aplicar las nuevas tecnologías biomédicas en el diagnóstico del síndrome de inmunodeficiencia humana causado por el VIH. Este novedoso método posee numerosas ventajas con respecto a las pruebas en sangre. Se plantea información sobre los fluidos bucales, los diversos componentes con posibilidad de diagnóstico presentes en la saliva y se establecen las características de un método diagnóstico (Omni-Sal© ) aplicado a personas que padecen de alguna enfermedad del complejo bucal(AU)


Subject(s)
Humans , Male , Female , Acquired Immunodeficiency Syndrome/diagnosis , Saliva/virology
SELECTION OF CITATIONS
SEARCH DETAIL
...