1.
Cardiol Ther ; 11(1): 129-141, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35138595

ABSTRACT

INTRODUCTION: Fondaparinux is a low molecular weight heparin anticoagulant used to manage the full spectrum of acute coronary syndrome (ACS) patients and has proved its efficacy and safety in multiple clinical trials. However, there are limited data available showing whether the same results could be reproduced in real-world practice on an Indian population. Our objective was to determine the effectiveness and tolerability of fondaparinux in the management of symptomatic ACS in real-world clinical practice. METHODS: The EMR data of hospitalized ACS patients (n = 611), from January 2015 to January 2020, representing UA or NSTEMI or STEMI and were prescribed fondaparinux (2.5 mg once daily) to manage ACS were analyzed. The effectiveness was analyzed as recurrence of ACS and tolerability as total incidence of major bleeding during hospitalization, at 30 days and 180 days. Appropriate statistical analysis was used with a statistically significance of p value < 0.05. RESULTS: The incidence of recurrent ACS was not seen during hospitalization and in the first 30 days, while in only 0.65% (n = 4) patients, ACS reoccurred within 180 days. In a mean duration of 172.75 ± 3.20 days, UA was reported in 0.49% (n = 3) patients, NSTEMI in 0.16% (n = 1) of patients, and STEMI was not documented. None of the major bleeding events occurred during the entire study period, whereas minor bleeding events were reported during hospitalization 0.98% (n = 6) and at 30 days 0.16% (n = 1). The bleeding events were statistically insignificant (p value > 0.05). No incidences of stent thrombosis were reported during the entire study period. CONCLUSIONS: In the real world, fondaparinux was found to be effective and tolerable when used to manage symptomatic ACS patients regardless of revascularization procedure with no incidence of stent thrombosis, and minimal recurrent ACS and insignificant increase in bleeding events.

2.
Cardiol Ther ; 10(2): 465-480, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34115326

ABSTRACT

INTRODUCTION: The renoprotective effects of dihydropyridine calcium channel blockers (CCBs) have been established as non-inferior to other classes of antihypertensive drugs. Studying their effect on renal outcome parameters, specifically for amlodipine as monotherapy, in real-world settings can further help in expanding its usage among Indian patients. This study was performed to assess the effects of amlodipine and other dihydropyridine CCBs (cilnidipine, benidipine and azelnidipine) on renal parameters and effectiveness in blood pressure reduction in Indian patients. METHODS: The retrospective data of adult patients (> 18 years) with essential hypertensive who were prescribed amlodipine (n = 92), cilnidipine (n = 91), benidipine (n = 70) or azelnidipine (n = 71) as monotherapy were analyzed. The renal outcomes, serum creatinine, estimated glomerular filtration rate (eGFR), blood urea nitrogen (BUN), microalbumin, urine albumin-to-creatinine ratio (UACR), sodium and potassium levels, and mean changes in BP were analyzed from baseline to 12 months. Appropriate statistical methods were used to determine the significance (p value < 0.05). RESULTS: From baseline to the end of the study, mean serum creatinine changed from 0.98 ± 0.17 to 1.07 ± 0.28 mg/dL with amlodipine, 0.97 ± 0.18 to 1.13 ± 0.50 mg/dL with cilnidipine, 0.98 ± 0.30 to 0.97 ± 0.27 mg/dL wi th benidipine, and 0.99 ± 0.23 to 0.98 ± 0.25 mg/dL with azelnidipine (p = 0.01). The mean microalbumin and UACR were reduced from baseline to the end of the study (p = 0.06 and p > 0.05). No significant changes were observed in BUN, sodium or potassium levels. Overall, for all CCBs, the mean systolic blood pressure (SBP) and diastolic blood pressure (DBP) values were reduced from baseline to the end of the study (p = 0.002). At the end of the study, the average dose of amlodipine was 7.25 mg, and the average reduction in SBP and DBP per mg dose was 1.54 and 0.57 mmHg. The corresponding numbers for the other CCBs were as follows: cilnidipine, 14.28 mg, 0.26 and 0.01; benidipine, 5.71 mg, 0.41 and 0.11; azelnidipine, 15.88 mg, 0.13 and 0.06. CONCLUSION: Amlodipine and other CCBs demonstrated good efficacy and similar effects on renal parameters from baseline to end of study. Amlodipine also showed higher potency by demonstrating greater BP reduction at a lower dose. Thus, amlodipine can remain a preferred choice among CCBs, even with the advent of the newer CCBs.

3.
Ann Acad Med Singap ; 48(5): 150-155, 2019 May.
Article in English | MEDLINE | ID: mdl-31210252

ABSTRACT

INTRODUCTION: Although drug-eluting stents (DES) have outclassed the use of bare metal stents, the safety and efficacy of DES at long-term follow-up has still been conflicting because of increased occurrence of late or very late restenosis and stent thrombosis after DES implantation. Hence, the present study was aimed to evaluate the 3-year safety and clinical performance of biodegradable polymer-coated ultra-thin (60 µm) sirolimus-eluting stent (SES) in real-world patients with coronary artery disease (CAD). MATERIALS AND METHODS: This was a physician-initiated, retrospective, single-centre, observational study that included 237 consecutive patients who had previously undergone implantation of only Supraflex SES (Sahajanand Medical Technologies Pvt Ltd, Surat, India) for the treatment of CAD. Follow-up was received after 1 year and 3 years of stent implantation. The primary endpoint was major adverse cardiac events (MACE), a composite of cardiac death, myocardial infarction (MI) and target lesion revascularisation (TLR). Stent thrombosis was considered as a safety endpoint. RESULTS: The mean age of patients was 64.1 ± 10.2 years, and 192 (81.0%) patients were male. The average stent length and diameter were 24.4 ± 9.0 mm and 3.1 ± 0.4 mm, respectively. The cumulative MACE rate at 3 years follow-up was 6.5% which included 4 (1.8%) cardiac deaths, 6 (2.8%) MI, and 4 (1.8%) TLR. There were 2 (0.9%) cases of stent thrombosis. CONCLUSION: Treatment of patients with CAD in real-world clinical practice was associated with sustained clinical safety and low rates of restenosis, stent thrombosis and MACE up to 3 years after Supraflex SES implantation.


Subject(s)
Biodegradable Plastics/therapeutic use , Coronary Artery Disease/surgery , Coronary Restenosis , Drug-Eluting Stents/adverse effects , Myocardial Infarction , Percutaneous Coronary Intervention , Sirolimus/therapeutic use , Aged , Coated Materials, Biocompatible/therapeutic use , Coronary Artery Disease/epidemiology , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Female , Humans , Immunosuppressive Agents/therapeutic use , India/epidemiology , Male , Middle Aged , Myocardial Infarction/epidemiology , Myocardial Infarction/etiology , Outcome and Process Assessment, Health Care , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Prosthesis Design , Retrospective Studies , Survival Analysis
4.
Indian Heart J ; 66(2): 235-7, 2014.
Article in English | MEDLINE | ID: mdl-24814125

ABSTRACT

A 55-year-old male presented with progressive dyspnea, swelling of legs and abdominal distension for past one week. Routine investigation showed presence of large pericardial effusion. Pericardiocentesis tapped a yellow colored sterile fluid with predominant polymorphs. However sequence of events following pericardiocentesis were unusual as patient developed stroke. MRI brain and CECT thorax were done. MRI brain showed small infarct and CECT showed presence of open safety pin eroding through esophagus and communicating with left atrium with thrombus and an air pocket within. Patient developed progressive encephalopathy and CT brain revealed multiple infarcts with pneumocephalus.


Subject(s)
Esophageal Fistula/complications , Foreign Bodies/diagnostic imaging , Heart Atria/diagnostic imaging , Pericardial Effusion/diagnostic imaging , Stroke/diagnosis , Thrombosis/diagnostic imaging , Disease Progression , Esophageal Fistula/diagnostic imaging , Fatal Outcome , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Pericardial Effusion/etiology , Pericardial Effusion/surgery , Pericardiocentesis/methods , Rare Diseases , Stroke/etiology , Thrombosis/complications , Tomography, X-Ray Computed/methods