Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 83
Filter
1.
Article in English | MEDLINE | ID: mdl-38595174

ABSTRACT

OBJECTIVE: The aim of this study was to compare portal venous phase photon-counting CT (PCCT) using 20 cc less than weight-based contrast dosing with energy-integrating detector CT (EID-CT) using weight-based dosing by quantitative and qualitative analysis. METHODS: Fifty adult patients who underwent a reduced intravenous contrast dose portal venous phase PCCT from May 1, 2023, to August 10, 2023, and a prior portal-venous EID-CT with weight-based contrast dosing were retrospectively identified. Hounsfield units (HU) and noise (SD of HU) were obtained from region-of-interest measurements on 70-keV PCCT and EID-CT in 4 hepatic segments, the main and right portal vein, and both paraspinal muscles. Signal-to-noise and contrast-to-noise ratios were computed. Three abdominal radiologists qualitatively assessed overall image quality, hepatic enhancement, and confidence for metastasis identification on 5-point Likert scales. Readers also recorded the presence/absence of hepatic metastases. Quantitative variables were compared with paired t tests, and multiple comparisons were accounted for with a Bonferroni-adjusted α level of .0016. Ordinal logistic regression was used to evaluate qualitative assessments. Interreader agreement for hepatic metastases was calculated using Fleiss' κ. RESULTS: Fifty patients (32 women; mean [SD] age, 64 [13] years) were included. There was no significant difference in hepatic HU, portal vein HU, noise, and signal-to-noise or contrast-to-noise ratio between reduced contrast dose portal venous phase PCCT versus EID-CT (all Ps > 0.0016). Image quality, degree of hepatic enhancement, and confidence for metastasis identification were not different for reduced dose PCCT 70-keV images and EID-CT (P = 0.06-0.69). κ Value for metastasis identification was 0.86 (95% confidence interval, 0.70-1.00) with PCCT and 0.78 (95% confidence interval, 0.59-0.98) with EID-CT. CONCLUSION: Reduced intravenous contrast portal venous phase PCCT 70-keV images had similar attenuation and image quality as EID-CT with weight-based dosing. Metastases were identified with near-perfect agreement in reduced dose PCCT 70-keV images.

2.
Eur J Radiol ; 175: 111437, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38520805

ABSTRACT

PURPOSE: To calculate the prevalence of pancreatic cysts on photon counting CT (PCCT) and compare with that of 128-slice conventional energy-integrating detector CT (EIDCT). METHOD: A retrospective single institution database search identified all contrast-enhanced abdominal CT examinations performed at an outpatient facility that has both a PCCT and EIDCT between 4/11/2022 and 7/26/2022. The presence and size of pancreatic cysts were recorded. In patients with PCCT reported pancreatic cysts, prior CT imaging (EIDCT) was reviewed for reported pancreatic cysts. Fisher's exact test was used to compare the pancreatic cyst detection rate for PCCT and EIDCT. Wilcoxon rank sum test was used to compare cyst size and patient age. A p <.05 indicated statistical significance. RESULTS: 2494 patients were included. Our pancreatic cyst detection rate was 4.9 % (49/1009) with PCCT and 3.0 % (44/1485) for EIDCT (p =.017). For CT angiograms, pancreatic cysts were detected in 6.6 % (21/319) with PCCT and 0.0 % (0/141) with EIDCT (p <.001). Pancreatic cyst detection rate was not statistically different for portal venous, enterography, renal mass, pancreas, 3-phase liver, or venogram protocols (all p >.05). Mean[SD] pancreatic cyst size was 13.7[9.7]mm for PCCT and 15.3[14.7] for EIDCT (p =.95). 55.1 % (27/49) of PCCT and 61.4 % (27/44) of EIDCT that described pancreatic cysts had prior contrast-enhanced EIDCTs. Of these, 40.7 % (11/27) of PCCT and 14.8 % (4/27) of EIDCT described pancreatic cysts were not previously reported (p =.027). CONCLUSIONS: Photon-counting CT afforded greater pancreatic cyst detection than conventional energy-integrating detector CT, particularly with CT angiograms.


Subject(s)
Pancreatic Cyst , Photons , Tomography, X-Ray Computed , Humans , Pancreatic Cyst/diagnostic imaging , Male , Female , Middle Aged , Prevalence , Retrospective Studies , Aged , Tomography, X-Ray Computed/methods , Adult , Aged, 80 and over , Contrast Media
3.
Abdom Radiol (NY) ; 49(1): 271-278, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37814149

ABSTRACT

PURPOSE: To determine optimal iodine density thresholds for active inflammation in CD patients with PCCT enterography and determine if iodine density can be used to stratify CD activity severity. METHODS: A retrospective PACS search identified patients with CD imaged with PCCT enterography from 4/11/2022 to 10/30/2022 and with clinical notes, endoscopic/surgical pathology and available source PCCT data for iodine density analysis. Two abdominal radiologists with expertise in CD each drew two region of interest measurements within the visibly most affected region of terminal or neoterminal ileum wall on commercially available system (SyngoVia). Radiologists were blinded to clinical information and pathologic findings. Disease activity and severity were recorded from the pathology report. Harvey-Bradshaw Index, medications, and laboratory values were recorded. Receiver operating characteristic (ROC) curves were utilized to determine the optimum iodine density threshold for active inflammation and mild versus moderate-to-severe inflammation. Intra- and inter-reader agreement was assessed by intra-class correlation coefficient (ICC). RESULTS: 23 CD patients (15 females; mean [SD] age: 52 [17] years) imaged with PCCT enterography were included. 15/23 had active inflammation: 9/15 mild, 4/15 moderate, and 2/15 severe active inflammation. The optimal iodine density threshold for active inflammation was 2.7 mg/mL, with 97% sensitivity, 100% specificity, and 98% accuracy (AUC = 1.00). The optimal iodine density threshold for distinguishing mild from moderate-to-severe inflammation was 3.4 mg/mL, with 83% sensitivity, 89% specificity, and 87% accuracy (AUC = 0.85). Intra-reader reliability (R1/R2) ICC was 0.81/0.86. Inter-reader reliability ICC was 0.94. CONCLUSION: Iodine density from PCCT enterography can distinguish mild from moderate-to-severe active inflammation.


Subject(s)
Crohn Disease , Iodine , Female , Humans , Middle Aged , Crohn Disease/diagnostic imaging , Crohn Disease/pathology , Retrospective Studies , Reproducibility of Results , Tomography, X-Ray Computed/methods , Inflammation/diagnostic imaging , Inflammation/pathology
4.
Abdom Radiol (NY) ; 49(3): 868-874, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38006415

ABSTRACT

PURPOSE: To quantitatively and qualitatively compare the degree of iodine removal in the collecting system from PCCT urographic phase-derived virtual noncontrast (VNC) images obtained at 140 kV versus 120 kV. METHODS: A retrospective PACS search identified adult patients (>18 years) who underwent a PCCT urogram for hematuria from 4/2022 to 4/2023 with available urographic phase-derived VNC images in PACS. Tube voltage (120 kV, 140 kV), body mass index, CTDIvol, dose length product (DLP), and size-specific dose estimate (SSDE) were recorded. Hounsfield Unit (HU) in both renal pelvises and the urinary bladder on urographic-derived VNC were recorded. Three radiologists qualitatively assessed the degree of iodine removal (renal pelvis, urinary bladder) and diagnostic confidence for urinary stone detection. Continuous variables were compared for 140 kV versus 120 kV with the Wilcoxon rank sum test. A p < .05 indicated statistical significance. RESULTS: 63 patients (34 male; median (Q1, Q3) age: 30 (26, 34) years; 140 kV/120 kV: 30 patients/33 patients) were included. BMI, CTDIvol, DLP, and SSDE were not different for 140 kV and 120 kV (all p > .05). Median (Q1, Q3) collecting system HU (renal pelvis and bladder) was 0.9 (- 3.6, 4.4) HU at 140 kV and 10.5 (3.6, 26.7) HU at 120 kV (p = .04). Diagnostic confidence for urinary calculi was 4.6 [1.1] at 140 kV and 4.1 [1.4] at 120 kV (p = .005). Diagnostic confidence was 5/5 (all readers) in 82.2% (74/90) at 140 kV and 59.6% (59/99) at 120 kV (p < .001). CONCLUSION: PCCT urographic phase-derived VNC images obtained at 140 kV had better collecting system iodine removal than 120 kV with similar patient radiation exposure. With excellent PCCT urographic phase iodine removal at 140 kV, consideration can be made to utilize a single-phase CT urogram in young patients.


Subject(s)
Iodine , Radiography, Dual-Energy Scanned Projection , Urinary Calculi , Adult , Humans , Male , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods
5.
J Comput Assist Tomogr ; 48(2): 251-256, 2024.
Article in English | MEDLINE | ID: mdl-38013203

ABSTRACT

PURPOSE: This study aimed to compare the image quality of portal venous phase-derived virtual noncontrast (VNC) images from photon-counting computed tomography (PCCT) with energy-integrating dual-energy computed tomography (EI-DECT) in the same patient using quantitative and qualitative analyses. METHODS: Consecutive patients retrospectively identified with available portal venous phase-derived VNC images from both PCCT and EI-DECT were included. Patients without available VNC in picture archiving and communication system in PCCT or prior EI-DECT and non-portal venous phase acquisitions were excluded. Three fellowship-trained radiologists blinded to VNC source qualitatively assessed VNC images on a 5-point scale for overall image quality, image noise, small structure delineation, noise texture, artifacts, and degree of iodine removal. Quantitative assessment used region-of-interest measurements within the aorta at 4 standard locations, both psoas muscles, both renal cortices, spleen, retroperitoneal fat, and inferior vena cava. Attenuation (Hounsfield unit), quantitative noise (Hounsfield unit SD), contrast-to-noise ratio (CNR) (CNR vascular , CNR kidney , CNR spleen , CNR fat ), signal-to-noise ratio (SNR) (SNR vascular , SNR kidney , SNR spleen , SNR fat ), and radiation dose were compared between PCCT and EI-DECT with the Wilcoxon signed rank test. A P < 0.05 indicated statistical significance. RESULTS: A total of 74 patients (27 men; mean ± SD age, 63 ± 13 years) were included. Computed tomography dose index volumes for PCCT and EI-DECT were 9.2 ± 3.5 mGy and 9.4 ± 9.0 mGy, respectively ( P = 0.06). Qualitatively, PCCT VNC images had better overall image quality, image noise, small structure delineation, noise texture, and fewer artifacts (all P < 0.00001). Virtual noncontrast images from PCCT had lower attenuation (all P < 0.05), noise ( P = 0.006), and higher CNR ( P < 0.0001-0.04). Contrast-enhanced structures had lower SNR on PCCT ( P = 0.001, 0.002), reflecting greater contrast removal. The SNRfat (nonenhancing) was higher for PCCT than EI-DECT ( P < 0.00001). CONCLUSIONS: Virtual noncontrast images from PCCT had improved image quality, lower noise, improved CNR and SNR compared with those derived from EI-DECT.


Subject(s)
Radiography, Dual-Energy Scanned Projection , Tomography, X-Ray Computed , Male , Humans , Middle Aged , Aged , Retrospective Studies , Tomography, X-Ray Computed/methods , Signal-To-Noise Ratio , Aorta , Kidney , Radiography, Dual-Energy Scanned Projection/methods
6.
Gastrointest Endosc Clin N Am ; 33(3): 519-531, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37245933

ABSTRACT

This article reviews the types of pancreatic cysts encountered in Radiologic practice. It summarizes the malignancy risk of each of the following: serous cystadenoma, mucinous cystic tumor, intraductal papillary mucinous neoplasm main duct and side branch, and some miscellaneous cysts such as neuroendocrine tumor and solid pseudopapillary epithelial neoplasm. Specific reporting recommendations are given. The choice between radiology follow-up versus endoscopic analysis is discussed.


Subject(s)
Neoplasms, Cystic, Mucinous, and Serous , Pancreatic Cyst , Pancreatic Neoplasms , Radiology , Humans , Pancreatic Cyst/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Radiography
7.
Gastrointest Endosc Clin N Am ; 33(3): 533-546, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37245934

ABSTRACT

Pancreatic cystic lesions are frequently identified on cross-sectional imaging. As many of these are presumed branch-duct intraductal papillary mucinous neoplasms, these lesions generate much anxiety for the patients and clinicians, often necessitating long-term follow-up imaging and even unnecessary surgical resections. However, the incidence of pancreatic cancer is overall low for patients with incidental pancreatic cystic lesions. Radiomics and deep learning are advanced tools of imaging analysis that have attracted much attention in addressing this unmet need, however, current publications on this topic show limited success and large-scale research is needed.


Subject(s)
Adenocarcinoma, Mucinous , Carcinoma, Pancreatic Ductal , Pancreatic Cyst , Pancreatic Neoplasms , Humans , Carcinoma, Pancreatic Ductal/pathology , Carcinoma, Pancreatic Ductal/surgery , Adenocarcinoma, Mucinous/pathology , Adenocarcinoma, Mucinous/surgery , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/pathology , Pancreas/pathology , Pancreatic Cyst/diagnostic imaging
8.
Abdom Radiol (NY) ; 48(7): 2219-2227, 2023 07.
Article in English | MEDLINE | ID: mdl-37097450

ABSTRACT

PURPOSE: To compare dual-source dual-energy CT enterography (dsDECTE) obtained iodine density (I) (mg/mL) and I normalized to the aorta (I%) with Crohn's disease (CD) phenotypes defined by the SAR-AGA small bowel CD consensus statement. METHODS: Fifty CD patients (31 male, 19 female; mean [SD] age: 50.4 [15.2] years) who underwent dsDECTE were retrospectively identified. Two abdominal radiologists assigned CD phenotypes: no active inflammation (group-2), active inflammation without (group-3) or with luminal narrowing (group-4), stricture with active inflammation (group-5), stricture without active inflammation (group-1), and penetrating disease (group-6). Semiautomatic prototype software was used to determine the median I and I% of CD-affected small bowel mucosa for each patient. The means of the I and I% medians were compared among 4 groups ("1 + 2", "3 + 4", "5", "6") using one-way ANOVA (significance level 0.05 for each outcome) for each outcome individually followed by Tukey's range test for pairwise comparisons with adjusted p-values (overall alpha = 0.05). RESULTS: Mean [SD] I was 2.14 [1.07] mg/mL for groups 1 + 2 (n = 16), 3.54 [1.71] mg/mL for groups 3 + 4 (n = 15), 5.5 [3.27] mg/mL for group- "5" (n = 9), and 3.36 [1.43] mg/mL for group-"6" (n = 10) (ANOVA p = .001; group "1 + 2" versus "5" adj-p = .0005). Mean [SD] I% was 21.2 [6.13]% for groups 1 + 2, 39.47 [9.71]% for groups 3 + 4, 40.98 [11.76]% for group-5, and 35.01 [7.58]% for group-6 (ANOVA p < .0001; groups "1 + 2" versus "3 + 4" adj-p < .0001, group "1 + 2" versus "5" adj-p < .0001, and groups "1 + 2" versus "6" adj-p = .002). CONCLUSION: Iodine density obtained from dsDECTE significantly differed among CD phenotypes defined by SAR-AGA, with I (mg/mL) increasing with phenotype severity and decreasing for penetrating disease. I and I% can be used to phenotype CD.


Subject(s)
Crohn Disease , Iodine , Male , Female , Humans , Crohn Disease/diagnostic imaging , Constriction, Pathologic , Retrospective Studies , Tomography, X-Ray Computed , Inflammation , Phenotype , Magnetic Resonance Imaging
9.
Abdom Radiol (NY) ; 48(9): 2978-2985, 2023 09.
Article in English | MEDLINE | ID: mdl-36871233

ABSTRACT

PURPOSE: Given that ileal pouch-anal anastomosis (IPAA) surgery is a technically challenging and high-morbidity procedure, there are numerous pertinent imaging findings that need to be clearly and efficiently communicated to the IBD surgeons for essential patient management and surgical planning. Structured reporting has been increasingly used over the past decade throughout various radiology subspecialties to improve reporting clarity and completeness. We compare structured versus non-structured reporting of pelvic MRI for ileal pouch to evaluate for clarity and effectiveness. METHODS: 164 consecutive pelvic MRI's for ileal pouch evaluation, excluding subsequent exams for the same patient, acquired between 1/1/2019 and 7/31/2021 at one institution were included, before and after implementation (11/15/2020) of a structured reporting template, which was created with institutional IBD surgeons. Reports were assessed for the presence of 18 key features required for complete ileal pouch assessment: anastomosis (IPAA, tip of J, pouch body), cuff (length, cuffitis), pouch body (size, pouchitis, stricture), pouch inlet/pre-pouch ileum (stricture, inflammation, sharp angulation), pouch outlet (stricture), peripouch mesentery (position, mesentery twist), pelvic abscess, peri-anal fistula, pelvic lymph nodes, and skeletal abnormalities. Subgroup analysis was performed based on reader experience and divided into three categories: experienced (n = 2), other intra-institutional (n = 20), or affiliate site (n = 6). RESULTS: 57 (35%) structured and 107 (65%) non-structured pelvic MRI reports were reviewed. Structured reports contained 16.6 [SD:4.0] key features whereas non-structured reports contained 6.3 [SD:2.5] key features (p < .001). The largest improvement following template implementation was for reporting sharp angulation of the pouch inlet (91.2% vs. 0.9%, p < .001), tip of J suture line and pouch body anastomosis (both improved to 91.2% from 3.7%). Structured versus non-structured reports contained mean 17.7 versus 9.1 key features for experienced readers, 17.0 versus 5.9 for other intra-institutional readers, and 8.7 versus 5.3 for affiliate site readers. CONCLUSION: Structured reporting of pelvic MRI guides a systematic search pattern and comprehensive evaluation of ileal pouches, and therefore facilitates surgical planning and clinical management. This standardized reporting template can serve as baseline at other institutions for adaptation based on specific radiology and surgery preferences, fostering a collaborative environment between radiology and surgery, and ultimately improving patient care.


Subject(s)
Colonic Pouches , Inflammatory Bowel Diseases , Proctocolectomy, Restorative , Humans , Constriction, Pathologic/surgery , Proctocolectomy, Restorative/methods , Magnetic Resonance Imaging , Postoperative Complications
10.
AJR Am J Roentgenol ; 219(6): 903-914, 2022 12.
Article in English | MEDLINE | ID: mdl-35856454

ABSTRACT

Pancreatic ductal adenocarcinoma (PDAC) is one of the most aggressive malignancies, with a dismal survival rate. Screening the general population for early detection of PDAC is not recommended, but because early detection improves survival, high-risk individuals, defined as those meeting criteria based on a family history of PDAC and/or the presence of known pathogenic germline variant genes with PDAC risk, are recommended to undergo screening with MRI and/or endoscopic ultrasound at regular intervals. The Pancreatic Cancer Early Detection (PRECEDE) Consortium was formed in 2018 and is composed of gastroenterologists, geneticists, pancreatic surgeons, radiologists, statisticians, and researchers from 40 sites in North America, Europe, and Asia. The overarching goal of the PRECEDE Consortium is to facilitate earlier diagnosis of PDAC for high-risk individuals to increase survival of the disease. A standardized MRI protocol and reporting template are needed to enhance the quality of screening examinations, improve consistency of clinical management, and facilitate multiinstitutional research. We present a consensus statement to standardize MRI screening and reporting for individuals with elevated risk of pancreatic cancer.


Subject(s)
Carcinoma, Pancreatic Ductal , Pancreatic Neoplasms , Humans , Early Detection of Cancer , Carcinoma, Pancreatic Ductal/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Pancreatic Neoplasms/genetics , Magnetic Resonance Imaging , Reference Standards , Pancreatic Neoplasms
11.
Abdom Radiol (NY) ; 47(10): 3406-3413, 2022 10.
Article in English | MEDLINE | ID: mdl-35833999

ABSTRACT

PURPOSE: To compare terminal ileum (TI) mucosal iodine density obtained at dual-energy CT enterography (DECTE) with conventional CT interpretation and endoscopy in patients with Crohn's disease (CD). MATERIALS AND METHODS: Twenty-three CD patients (14 men; mean[SD] age:48.1[16.7] years) with endoscopy within 30 days of DECTE were retrospectively identified. An inflammatory bowel disease gastroenterologist reviewed endoscopic images. Two radiologists qualitatively assessed the presence of active TI inflammation. Mean iodine density normalized to the aorta (I%), mean absolute iodine density (I), and iodine density standard deviation (ISD) from the distal 2 cm ileum (TI) mucosa obtained using semiautomatic prototype software were compared with endoscopic assessment using Mann Whitney tests. The optimal threshold I% and I were determined from receiver operating curves (ROC). Sensitivity and specificity of conventional interpretation and determined iodine thresholds were compared using McNemar's test. Inter-reader agreement was assessed using kappa. A p < 0.05 indicated statistical significance. RESULTS: Twelve (52.1%) patients had endoscopic active inflammation. I% was 37.9[13.3]% for patients with and 21.7[7.5]% for patients without endoscopic active inflammation (p = 0.001). The optimal ROC threshold 24.6% had 100% sensitivity and 81.8% specificity (AUC = 0.909, 95% CI 0.777-1). I was 2.44[0.73]mg/mL for patients with and 1.77[1.00]mg/mL for patients without active endoscopic inflammation (p = 0.0455). The optimal ROC threshold 1.78 mg/mL I had 91.7% sensitivity and 63.6% specificity (AUC = 0.75, 95% CI 0.532-0.968). ISD was similar for patients with and without endoscopic active inflammation (0.82[0.33]mg/mL and 0.77[0.28]mg/mL, respectively, p = 0.37). Conventional interpretation sensitivity and specificity (R1/R2) were 83.3%/91.7% and 72.7%/54.5%, respectively (all p > 0.05) with moderate inter-reader agreement (Κ = 0.542[95% CI 0.0202-0.088]). CONCLUSION: Mean normalized iodine density is highly sensitive and specific for endoscopic active inflammation. DECTE could be considered as a surrogate to endoscopy in CD patients. Despite trends towards improved sensitivity and specificity compared with conventional interpretation, future larger studies are needed.


Subject(s)
Crohn Disease , Iodine , Contrast Media , Crohn Disease/diagnostic imaging , Endoscopy, Gastrointestinal , Humans , Inflammation/diagnostic imaging , Male , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed/methods
12.
Radiology ; 301(1): 144-151, 2021 10.
Article in English | MEDLINE | ID: mdl-34342502

ABSTRACT

Background Dual-energy CT enterography (DECTE) has been shown to be useful in characterizing Crohn disease activity compared with clinical markers of inflammation but, to the knowledge of the authors, comparison has not been made with histopathologic specimens. Purpose To compare mucosal iodine density obtained at DECTE from Crohn disease-affected bowel with histopathologic specimens from surgically resected ileocolectomy bowel segments or terminal ileum colonoscopic biopsies in the same patients. Materials and Methods This was a retrospective study. Bowel segments in adults with Crohn disease who underwent DECTE from January 2017 to April 2019 within 90 days of ileocolectomy or colonoscopy were retrospectively evaluated with prototype software allowing the semiautomatic determination of inner hyperdense bowel wall (mucosal) mean iodine density, normalized to the aorta. Mean normalized iodine density and clinical activity indexes (Crohn Disease Activity Index [CDAI] and Harvey-Bradshaw Index [HBI]) were compared with histologic active inflammation grades by using two-tailed t tests. Receiver operating characteristic curves were generated for mean normalized iodine density, CDAI, and HBI to determine sensitivity, specificity, and accuracy. A P value less than .05 was considered to indicate statistical significance. Results The following 16 patients were evaluated (mean age, 41 years ± 14 [standard deviation]): 10 patients (five men, five women; mean age, 41 years ± 15) with 19 surgical resection specimens and six patients with terminal ileum colonoscopic mucosal biopsies (four men, two women; mean age, 43 years ± 14). Mean normalized iodine density was 16.5% ± 5.7 for bowel segments with no active inflammation (n = 8) and 34.7% ± 9.7 for segments with any active inflammation (n = 17; P < .001). A 20% mean normalized iodine density threshold had sensitivity, specificity, and accuracy of 17 of 17 (100%; 95% CI: 80.5, 100), six of eight (75%; 95% CI: 35, 97), and 23 of 25 (92%; 95% CI: 74, 99), respectively, for active inflammation. Clinical indexes were similar for patients with and without active inflammation at histopathologic analysis (CDAI score, 261 vs 251, respectively [P = .77]; HBI score, 7.8 vs 6.4, respectively [P = .36]). Conclusion Iodine density from dual-energy CT enterography may be used as a radiologic marker of Crohn disease activity as correlated with histopathologic analysis. © RSNA, 2021 See also the editorial by Ohliger in this issue.


Subject(s)
Crohn Disease/diagnostic imaging , Crohn Disease/pathology , Inflammation/diagnostic imaging , Inflammation/pathology , Iodine/pharmacokinetics , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Adult , Biomarkers , Contrast Media/pharmacokinetics , Crohn Disease/complications , Female , Humans , Inflammation/etiology , Intestines/diagnostic imaging , Male , Middle Aged , Radiographic Image Enhancement/methods , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Young Adult
13.
J Comput Assist Tomogr ; 45(3): 427-430, 2021.
Article in English | MEDLINE | ID: mdl-34297511

ABSTRACT

OBJECTIVE: The aim of this study was to determine accuracy of height and weight prediction by a 3-dimensional (3D) camera. METHODS: A total of 453 patients whose computed tomography imaging used a 3D camera from December 19, 2018 to March 19, 2019 were retrospectively identified. An image of each patient was taken before the computed tomography by a 3D camera mounted to the ceiling. Using infrared imaging and machine learning algorithms, patient height and weight were estimated from this 3D camera image. A total of 363 images were used for training. The test set consisted of 90 images. The height and weight estimates were compared with true height and weight to determine absolute and percent error. A value of P < 0.05 indicated statistical significance. RESULTS: There was 2.0% (SD, 1.4) error in height estimation by the 3D camera, corresponding to 3.35 cm (SD, 2.39) absolute deviation (P = 1, n = 86). Weight estimation error was 5.1% (SD, 4.3), corresponding to 3.99 kg (SD, 3.11) absolute error (P = 0.74, n = 90). CONCLUSION: Pictures obtained from a 3D camera can accurately predict patient height and weight.


Subject(s)
Body Weights and Measures/instrumentation , Imaging, Three-Dimensional/instrumentation , Tomography, X-Ray Computed/instrumentation , Aged , Algorithms , Female , Humans , Male , Middle Aged , Patient Positioning , Retrospective Studies , Sensitivity and Specificity , Video Recording
14.
J Am Coll Radiol ; 18(9): 1324-1331, 2021 09.
Article in English | MEDLINE | ID: mdl-34004175

ABSTRACT

OBJECTIVE: To assess current practice patterns with respect to protocols used for incidental pancreatic cyst follow-up, management guidelines, and template reporting. METHODS: The Society of Abdominal Radiology Disease Focused Panel on intraductal pancreatic neoplasms distributed an anonymous 14-question survey to its members in June 2018 that focused on current utilization of incidental pancreatic cyst guidelines, protocols, and template reporting. RESULTS: Among the 1,390 email invitations, 323 responded, and 94.7% (306 of 323) completed all questions. Respondents were mainly radiologists (93.8%, 303 of 323) from academic institutions (74.7%, 227 of 304) in North America (93.7%, 286 of 305). Of respondents, 42.5% (136 of 320) preferred 2017 ACR recommendations, 17.8% (57 of 320) homegrown systems, 15.0% (48 of 320) Fukuoka guidelines, and 7.8% (25 of 320) American Gastroenterological Association guidelines. The majority (68.7%, 222 of 323) agreed or strongly agreed that developing a single international consensus recommendation for management was important, and most radiologists preferred to include them in reports (231 of 322, 71.7%); yet only half included recommendations in >75% of reports (161 of 321). MR cholangiopancreatography was the modality of choice for follow-up of <2.5 cm cysts. Intravenous contrast was routinely used by 69.7% (212 of 304). Standardized reporting templates were rarely used in practice (12.8% 39 of 306). CONCLUSIONS: Nearly 7 of 10 radiologists desire a unified international consensus recommendation for management of incidental cystic pancreatic lesions; ACR 2017 recommendations are most commonly used, followed by homegrown systems and Fukuoka guidelines. The majority of radiologists routinely use MR cholangiopancreatography with intravenous contrast for follow-up of incidental cystic lesions, but template reporting is rarely used.


Subject(s)
Pancreatic Cyst , Pancreatic Neoplasms , Radiology , Humans , Incidental Findings , Pancreatic Cyst/diagnostic imaging , Pancreatic Cyst/therapy , Radiography, Abdominal , Surveys and Questionnaires
15.
J Comput Assist Tomogr ; 45(2): 171-176, 2021.
Article in English | MEDLINE | ID: mdl-33661155

ABSTRACT

OBJECTIVE: The objective of this study was to determine if dual-energy computed tomography enterography (DECTE)-obtained iodine density can predict medical management change or surgery in Crohn disease patients. METHODS: The most active-appearing bowel segment on DECTE in 21 Crohn disease patients was retrospectively interrogated with prototype software determining the percentage of bowel wall (I) in specified ranges. Patients were categorized into 3 groups after DECTE: (1) no management change, (2) outpatient medication change, and (3) inpatient admission or surgery. Crohn's disease activity index was calculated. Group 3's percentage iodine density of >3 mg/mL and Crohn's disease activity index were compared with group 1/2. Crohn's disease activity index and percentage iodine density of >2 mg/mL were compared for groups 2/3 versus group 1 patients. RESULTS: There were 5 group 1, 6 group 2, and 10 group 3 patients. Group 3 patients had higher frequency of iodine density >3 mg/mL (27%) compared with groups 1/2 patients (12.6%) (P < 0.05). Crohn's disease activity index was similar (P = 0.98). Groups 2/3 patients had 60.5% iodine density of >2 mg/mL, whereas group 1 patients had 31.7% iodine density of >2 mg/mL (P < 0.05). Crohn's disease activity index was similar (P = 0.12). CONCLUSIONS: Iodine density from DECTE may predict medical or surgical Crohn disease management.


Subject(s)
Crohn Disease/diagnostic imaging , Intestine, Small/diagnostic imaging , Tomography, X-Ray Computed , Adult , Aged , Crohn Disease/pathology , Female , Humans , Intestine, Small/pathology , Iodine , Male , Middle Aged , Prognosis , Retrospective Studies
16.
Eur J Radiol ; 136: 109537, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33454459

ABSTRACT

PURPOSE: To compare CT isocenter accuracy, patient dose, and scan time in adults imaged with and without use of a 3D camera. METHOD: 571 CT examinations utilizing a 3D camera for initial patient positioning (optional radiographer isocenter adjustment) and 504 examinations scanned without the camera between 10/1/2018 and 3/19/2019 were retrospectively identified. All exams were chest or abdominopelvic CTs. The isocenters of these exams were compared with the true isocenters defined as the manually delineated centroid of the body in the CT volume. The size specific dose estimate (SSDE) (mGy) of radiation dose obtained from departmental software for the 4 most common protocols on one CT scanner was compared before and after implementation of the 3D camera. The times required for the entire scan and just the topogram "scout" were compared with and without the 3D camera for noncontrast chest and abdominopelvic CT enterography protocols. 2-tailed t-tests and Mann-Whitney U tests were used (P < 0.05 indicated statistical significance). RESULTS: The deviation from true isocenter was 6.8 ±â€¯6.1 mm (P = 0.043) and 16.3 ±â€¯14.0 mm (P < 0.01) with and without the 3D camera, respectively (P < 0.01). CT radiographers accepted isocenter location without alteration in 93 % of examinations. Average SSDE savings with the 3D camera ranged 1.0-2.4 mGy (21-31 %) for the 4 most commonly performed protocols (p < 0.01). Median scout time savings was 32 s (Camera vs. No-Camera cohorts) (P < 0.01). Average noncontrast chest CT and CT enterography scan time savings were 19 s and 17 s with the 3D camera, respectively (P < 0.01). CONCLUSIONS: The 3D camera improved accuracy of patient positioning while reducing radiation dose and examination time. Implementation of a 3D camera helps standardize workflow in a busy clinical practice.


Subject(s)
Drug Tapering , Tomography, X-Ray Computed , Adult , Humans , Patient Positioning , Radiation Dosage , Retrospective Studies
17.
AJR Am J Roentgenol ; 217(2): 347-358, 2021 08.
Article in English | MEDLINE | ID: mdl-32936014

ABSTRACT

Ileal pouch-anal anastomosis (IPAA) surgery is the reference standard surgical procedure for treatment of ulcerative colitis and most patients with familial adenomatous polyposis. This procedure allows preservation of fecal continence and gastrointestinal continuity. However, it is associated with a wide variety of complications, which often have nonspecific and overlapping clinical presentations, making imaging an important part of workup for pouch dysfunction. The purpose of this article is to propose structured reporting templates for MRI and water-soluble contrast enema (WSCE), based on our referral pouch center's experience, in patients who have undergone IPAA surgery. We review salient surgical technique, pouch anatomy, and imaging protocols, with an emphasis on a systematic search pattern for evaluation of ileal pouch complications using proposed structured reporting templates for MRI and WSCE.


Subject(s)
Contrast Media , Enema/methods , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Postoperative Complications/diagnostic imaging , Proctocolectomy, Restorative , Colon/diagnostic imaging , Humans , Rectum/diagnostic imaging , Referral and Consultation
18.
Abdom Radiol (NY) ; 46(4): 1586-1606, 2021 04.
Article in English | MEDLINE | ID: mdl-33185741

ABSTRACT

There have been many publications detailing imaging features of malignant transformation of intraductal papillary mucinous neoplasms (IPMN), management and recommendations for imaging follow-up of diagnosed or presumed IPMN. However, there is no consensus on several practical aspects of imaging IPMN that could serve as a clinical guide for radiologists and enable future data mining for research. These aspects include how to measure IPMN, define reporting terminology, standardize reporting and unify guidelines for surveillance. The Society of Abdominal Radiology (SAR) created multiple Disease-Focused Panels (DFP) comprised multidisciplinary panel members who focus on a particular disease, with the goal to develop ways for radiologists to improve patient care, education, and research. DFP members met to identify the current controversies and limitations of imaging pancreatic IPMN. This paper aims to provide a practical review of the key imaging characteristics of IPMN for trainees and practicing radiologists, to guide uniformity of performance and interpretation of surveillance imaging studies, and to improve communication with clinicians by providing a lexicon and reporting template based on the experience of the SAR-DFP panel members.


Subject(s)
Pancreatic Intraductal Neoplasms , Pancreatic Neoplasms , Radiology , Humans , Pancreas , Pancreatic Intraductal Neoplasms/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Radiography, Abdominal
19.
J Comput Assist Tomogr ; 44(5): 772-779, 2020.
Article in English | MEDLINE | ID: mdl-32936579

ABSTRACT

OBJECTIVE: To create a map of iodine densities within affected segments of small-bowel Crohn disease (CD) derived from contrast-enhanced dual-energy computed tomography enterography (DECTE) studies. METHODS: Twenty CD patients imaged with intravenous contrast-enhanced DECTE between June 2016 and December 2017 were retrospectively identified. Ten patients without clinical evidence of CD and 8 normal-appearing jejunal segments in CD patients were controls. Using prototype software, 8 manual contours were drawn along the mucosa of affected segments. Relatively normal-appearing bowel was included at the edges. These contours served as a basis for iodine density calculation and 3-dimensional iodine density map rendering. Color-coded iodine densities allowed detection and quantification of the most and least dense portion of each segment and also permitted relative comparison between segments. RESULTS: The average iodine density per CD involved segment ranged 1.0 to 3.3 mg/mL, which differed significantly from normal ileum (P < 0.0001) and normal-appearing jejunum in patients with CD (P = 0.0009). Standard deviations ranged from 0.8 to 1.7 mg/mL, which differed significantly from normal ileum (P = 0.0039) and normal-appearing jejunum in patients with CD (P = 0.0056). The amplitude of the power spectrum ranged from 0.66 to 3.3 demonstrating patches of iodine rather than uniform distribution. This differed significantly from normal ileum (P = 0.0005) and normal-appearing jejunum in patients with CD (P = 0.0004). CONCLUSIONS: Heterogeneous CD activity and distribution can be displayed as iodine density maps created from DECTE.


Subject(s)
Contrast Media/pharmacokinetics , Crohn Disease/diagnostic imaging , Imaging, Three-Dimensional/methods , Iodine/pharmacokinetics , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Female , Gastrointestinal Tract/diagnostic imaging , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...