Sensors (Basel) ; 23(24)2023 Dec 11.
Article in English | MEDLINE | ID: mdl-38139604

ABSTRACT

Future GRACE-like geodesy missions could benefit from adopting accelerometer technology akin to that of the LISA Pathfinder, which employed laser interferometric readout at the sub-picometer level in addition to the conventional capacitive sensing, which is at best at the level of 100 pm. Improving accelerometer performance holds great potential to enhance the scientific output of forthcoming missions, carrying invaluable implications for research in climate, water resource management, and disaster risk reduction. To reach sub-picometer displacement sensing precision in the millihertz range, laser interferometers rely on suppression of laser-frequency noise by several orders of magnitude. Many optical frequency stabilization methods are available with varying levels of complexity, size, and performance. In this paper, we describe the performance of a Mach-Zehnder interferometer based on a compact monolithic optic. The setup consists of a commercial fiber injector, a custom-designed pentaprism used to split and recombine the laser beam, and two photoreceivers placed at the complementary output ports of the interferometer. The structural stability of the prism is transferred to the laser frequency via amplification, integration, and feedback of the balanced-detection signal, achieving a fractional frequency instability better than 6 parts in 1013, corresponding to an interferometer pathlength stability better than 1pm/Hz. The prism was designed to host a second interferometer to interrogate the position of a test mass. This optical scheme has been dubbed "single-element dual-interferometer" or SEDI.

2.
Opt Express ; 31(23): 38443-38456, 2023 Nov 06.
Article in English | MEDLINE | ID: mdl-38017951

ABSTRACT

Squeezed light is injected into the dark port of gravitational wave interferometers, in order to reduce the quantum noise. A fraction of the interferometer output light can reach the OPO due to sub-optimal isolation of the squeezing injection path. This backscattered light interacts with squeezed light generation process, introducing additional measurement noise. We present a theoretical description of the noise coupling mechanism and we prove the model with experimental results. We propose a control scheme to achieve a de-amplification of the backscattered light inside the OPO with a consequent reduction of the noise caused by it. The scheme was implemented at the GEO 600 detector and has proven to be crucial in maintaining a good level of quantum noise reduction of the interferometer for high parametric gain of the OPO. In particular, the mitigation of the backscattered light noise helped in reaching 6 dB of quantum noise reduction [Phys. Rev. Lett.126, 041102 (2021)10.1103/PhysRevLett.126.041102]. We show that the impact of backscattered-light-induced noise on the squeezing performance is phenomenologically equivalent to increased phase noise of the squeezing angle control. The results discussed in this paper provide a way for a more accurate estimation of the residual phase noise of the squeezed light field. Finally, the knowledge of the backscattered light noise coupling mechanism is a useful tool to inform the design of the squeezing injection path in terms of path stability and optical isolation.

3.
Nature ; 600(7889): 424-428, 2021 12.
Article in English | MEDLINE | ID: mdl-34912085

ABSTRACT

The nature of dark matter remains unknown to date, although several candidate particles are being considered in a dynamically changing research landscape1. Scalar field dark matter is a prominent option that is being explored with precision instruments, such as atomic clocks and optical cavities2-8. Here we describe a direct search for scalar field dark matter using a gravitational-wave detector, which operates beyond the quantum shot-noise limit. We set new upper limits on the coupling constants of scalar field dark matter as a function of its mass, by excluding the presence of signals that would be produced through the direct coupling of this dark matter to the beam splitter of the GEO600 interferometer. These constraints improve on bounds from previous direct searches by more than six orders of magnitude and are, in some cases, more stringent than limits obtained in tests of the equivalence principle by up to four orders of magnitude. Our work demonstrates that scalar field dark matter can be investigated or constrained with direct searches using gravitational-wave detectors and highlights the potential of quantum-enhanced interferometry for dark matter detection.

4.
Phys Rev Lett ; 126(4): 041102, 2021 Jan 29.
Article in English | MEDLINE | ID: mdl-33576646

ABSTRACT

Photon shot noise, arising from the quantum-mechanical nature of the light, currently limits the sensitivity of all the gravitational wave observatories at frequencies above one kilohertz. We report a successful application of squeezed vacuum states of light at the GEO 600 observatory and demonstrate for the first time a reduction of quantum noise up to 6.03±0.02 dB in a kilometer scale interferometer. This is equivalent at high frequencies to increasing the laser power circulating in the interferometer by a factor of 4. Achieving this milestone, a key goal for the upgrades of the advanced detectors required a better understanding of the noise sources and losses and implementation of robust control schemes to mitigate their contributions. In particular, we address the optical losses from beam propagation, phase noise from the squeezing ellipse, and backscattered light from the squeezed light source. The expertise gained from this work carried out at GEO 600 provides insight toward the implementation of 10 dB of squeezing envisioned for third-generation gravitational wave detectors.

5.
Sensors (Basel) ; 20(17)2020 Sep 03.
Article in English | MEDLINE | ID: mdl-32899128

ABSTRACT

Tracking moving masses in several degrees of freedom with high precision and large dynamic range is a central aspect in many current and future gravitational physics experiments. Laser interferometers have been established as one of the tools of choice for such measurement schemes. Using sinusoidal phase modulation homodyne interferometry allows a drastic reduction of the complexity of the optical setup, a key limitation of multi-channel interferometry. By shifting the complexity of the setup to the signal processing stage, these methods enable devices with a size and weight not feasible using conventional techniques. In this paper we present the design of a novel sensor topology based on deep frequency modulation interferometry: the self-referenced single-element dual-interferometer (SEDI) inertial sensor, which takes simplification one step further by accommodating two interferometers in one optic. Using a combination of computer models and analytical methods we show that an inertial sensor with sub-picometer precision for frequencies above 10 mHz, in a package of a few cubic inches, seems feasible with our approach. Moreover we show that by combining two of these devices it is possible to reach sub-picometer precision down to 2 mHz. In combination with the given compactness, this makes the SEDI sensor a promising approach for applications in high precision inertial sensing for both next-generation space-based gravity missions employing drag-free control, and ground-based experiments employing inertial isolation systems with optical readout.

6.
Sensors (Basel) ; 21(1)2020 Dec 29.
Article in English | MEDLINE | ID: mdl-33383766

ABSTRACT

We propose to combine differential wave-front sensing (DWS) and differential power sensing (DPS) in a Mach-Zehnder type interferometer for measuring the rotational dynamics of a test-mass. Using the DWS method, a high sensitive measurement of 6 nrad Hz-1/2 in sub-Hz frequencies can be provided around the test-mass nominal position (±0.11 mrad), whereas the measurement of a wide rotation range (±5 mrad) is realized by the DPS method. The interferometer can be combined with deep frequency modulation (DFM) interferometry for measurement of the test-mass translational dynamics. The setup and the resulting interferometric signals are verified by simulations. An optimization algorithm is applied to find suitable positions of the lenses and the waist size of the input laser in order to determine the best trade of between the slope of DWS, dynamic range of DPS, and the interferometric contrast. Our simulation further allows to investigate the layout for robustness and design tolerances. We compare our device with a recent experimental realization of a DFM interferometer and find that a practical implementation of the interferometer proposed here has the potential to provide translational and rotational test-mass tracking with state-of-the-art sensitivity. The simple and compact design, and especially the capability of sensing the test-mass rotation in a wide range and simultaneously providing a high-precision measurement close to the test-mass nominal position makes the design especially suitable for example for employment in torsion pendulum setups.

7.
Opt Express ; 27(16): 22408-22418, 2019 Aug 05.
Article in English | MEDLINE | ID: mdl-31510535

ABSTRACT

Continuous-wave (cw) squeezed states of light have applications in sensing, metrology and secure communication. In recent decades their efficient generation has been based on parametric down-conversion, which requires pumping by externally generated pump light of twice the optical frequency. Currently, there is immense effort in miniaturizing squeezed-light sources for chip-integration. Designs that require just a single input wavelength are favored since they offer an easier realization. Here we report the first observation of cw squeezed states generated by self-phase modulation caused by subsequent up and down conversions. The wavelengths of input light and of balanced homodyne detection are identical, and 1550 nm in our case. At sideband frequencies around 1.075 GHz, a nonclassical noise reduction of (2.4 ± 0.1) dB is observed. The setup uses a second-order nonlinear crystal, but no externally generated light of twice the frequency. Our experiment is not miniaturized, but might open a route towards simplified chip-integrated realizations.

8.
Phys Rev Lett ; 121(17): 173601, 2018 Oct 26.
Article in English | MEDLINE | ID: mdl-30411965

ABSTRACT

High levels of laser power stability are necessary for high precision metrology applications. The classical limit for the achievable power stability is determined by the shot noise of the light used to generate a power control signal. Increasing the power of the detected light reduces the relative shot noise level and allows higher stabilities. However, sufficiently high power is not always available and the detection of high laser powers is challenging. Here, we demonstrate a nonclassical way to improve the achievable power stability without increasing the detected power. By the injection of a squeezed vacuum field of light we improve the classical laser power stability beyond its shot noise limit by 9.4_{-0.6}^{+0.6} dB at Fourier frequencies between 5 and 80 kHz. For only 90.6 µA of detected photocurrent we achieve a relative laser power noise of 2.0_{-0.1}^{+0.1}×10^{-8}/sqrt[Hz]. This is the first demonstration of a squeezed light-enhanced laser power stabilization and its performance is equivalent to an almost tenfold increase of detected laser power in a classical scheme. The analysis reveals that the technique presented here has the potential to achieve stability levels of 4.2×10^{-10}/sqrt[Hz] with 58 mA photocurrent measured on a single photodetector.

9.
Opt Lett ; 41(21): 5094-5097, 2016 Nov 01.
Article in English | MEDLINE | ID: mdl-27805703

ABSTRACT

The distribution of entanglement with Gaussian statistic can be used to generate a mathematically proven secure key for quantum cryptography. The distributed secret key rate is limited by the entanglement strength, the entanglement bandwidth, and the bandwidth of the photoelectric detectors. The development of a source for strongly bipartite entangled light with high bandwidth promises an increased measurement speed and a linear boost in the secure data rate. Here, we present the experimental realization of a Gaussian entanglement source with a bandwidth of more than 1.25 GHz. The entanglement spectrum was measured with balanced homodyne detectors and was quantified via the inseparability criterion introduced by Duan and coworkers with a critical value of 4 below which entanglement is certified. Our measurements yielded an inseparability value of about 1.8 at a frequency of 300 MHz to about 2.8 at 1.2 GHz, extending further to about 3.1 at 1.48 GHz. In the experiment we used two 2.6 mm long monolithic periodically poled potassium titanyl phosphate (KTP) resonators to generate two squeezed fields at the telecommunication wavelength of 1550 nm. Our result proves the possibility of generating and detecting strong continuous-variable entanglement with high speed.

10.
Phys Rev Lett ; 117(11): 110801, 2016 Sep 09.
Article in English | MEDLINE | ID: mdl-27661673

ABSTRACT

Squeezed states of light belong to the most prominent nonclassical resources. They have compelling applications in metrology, which has been demonstrated by their routine exploitation for improving the sensitivity of a gravitational-wave detector since 2010. Here, we report on the direct measurement of 15 dB squeezed vacuum states of light and their application to calibrate the quantum efficiency of photoelectric detection. The object of calibration is a customized InGaAs positive intrinsic negative (p-i-n) photodiode optimized for high external quantum efficiency. The calibration yields a value of 99.5% with a 0.5% (k=2) uncertainty for a photon flux of the order 10^{17} s^{-1} at a wavelength of 1064 nm. The calibration neither requires any standard nor knowledge of the incident light power and thus represents a valuable application of squeezed states of light in quantum metrology.

11.
Opt Express ; 24(2): 1676-84, 2016 Jan 25.
Article in English | MEDLINE | ID: mdl-26832546

ABSTRACT

Experiments for space and ground-based gravitational wave detectors often require a large dynamic range interferometric position readout of test masses with 1 pm/√Hz precision over long time scales. Heterodyne interferometer schemes that achieve such precisions are available, but they require complex optical set-ups, limiting their scalability for multiple channels. This article presents the first experimental results on deep frequency modulation interferometry, a new technique that combines sinusoidal laser frequency modulation in unequal arm length interferometers with a non-linear fit algorithm. We have tested the technique in a Michelson and a Mach-Zehnder Interferometer topology, respectively, demonstrated continuous phase tracking of a moving mirror and achieved a performance equivalent to a displacement sensitivity of 250 pm/Hz at 1 mHz between the phase measurements of two photodetectors monitoring the same optical signal. By performing time series fitting of the extracted interference signals, we measured that the linearity of the laser frequency modulation is on the order of 2% for the laser source used.

12.
Opt Express ; 21(11): 13572-9, 2013 Jun 03.
Article in English | MEDLINE | ID: mdl-23736610

ABSTRACT

We report the generation of squeezed vacuum states of light at 1550 nm with a broadband quantum noise reduction of up to 4.8 dB ranging from 5 MHz to 1.2 GHz sideband frequency. We used a custom-designed 2.6 mm long biconvex periodically-poled potassium titanyl phosphate (PPKTP) crystal. It featured reflectively coated end surfaces, 2.26 GHz of linewidth and generated the squeezing via optical parametric amplification. Two homodyne detectors with different quantum efficiencies and bandwidths were used to characterize the non-classical noise suppression. We measured squeezing values of up to 4.8 dB from 5 to 100 MHz and up to 3 dB from 100 MHz to 1.2 GHz. The squeezed vacuum measurements were limited by detection loss. We propose an improved detection scheme to measure up to 10 dB squeezing over 1 GHz. Our results of GHz bandwidth squeezed light generation provide new prospects for high-speed quantum key distribution.

13.
Opt Lett ; 37(12): 2367-9, 2012 Jun 15.
Article in English | MEDLINE | ID: mdl-22739910

ABSTRACT

Squeezed states can be employed for entanglement-based continuous-variable quantum key distribution, where the secure key rate is proportional to the bandwidth of the squeezing. We produced a nonclassical cw laser field at the telecommunication wavelength of 1550 nm, which showed squeezing over a bandwidth of more than 2 GHz. The experimental setup used parametric downconversion via a periodically poled potassium titanyl phosphate crystal. We did not use any resonant enhancement for the fundamental wavelength, which should in principle allow a production of squeezed light over the full phase-matching bandwidth of several nanometers. We measured the squeezing to be up to 0.3 dB below the vacuum noise from 50 MHz to 2 GHz limited by the measuring bandwidth of the homodyne detector. The squeezing strength was possibly limited by thermal lensing inside the nonlinear crystal.

14.
Opt Lett ; 36(17): 3467-9, 2011 Sep 01.
Article in English | MEDLINE | ID: mdl-21886246

ABSTRACT

We report on the observation of high-efficiency frequency doubling of 1550 nm continuous-wave laser light in a nonlinear cavity containing a periodically poled potassium titanyl phosphate crystal (PPKTP). The fundamental field had a power of 1.10 W and was converted into 1.05 W at 775 nm, yielding a total external conversion efficiency of 95±1%. The latter value is based on the measured depletion of the fundamental field being consistent with the absolute values derived from numerical simulations. According to our model, the conversion efficiency achieved was limited by the nonperfect mode matching into the nonlinear cavity and by the nonperfect impedance matching for the maximum input power available. Our result shows that cavity-assisted frequency conversion based on PPKTP is well suited for low-decoherence frequency conversion of quantum states of light.

15.
Opt Express ; 19(25): 25763-72, 2011 Dec 05.
Article in English | MEDLINE | ID: mdl-22273968

ABSTRACT

Continuous-wave squeezed states of light at the wavelength of 1550 nm have recently been demonstrated, but so far the obtained factors of noise suppression still lag behind today's best squeezing values demonstrated at 1064 nm. Here we report on the realization of a half-monolithic nonlinear resonator based on periodically-poled potassium titanyl phosphate which enabled the direct detection of up to 12.3 dB of squeezing at 5 MHz. Squeezing was observed down to a frequency of 2 kHz which is well within the detection band of gravitational wave interferometers. Our results suggest that a long-term stable 1550 nm squeezed light source can be realized with strong squeezing covering the entire detection band of a 3rd generation gravitational-wave detector such as the Einstein Telescope.


Subject(s)
Artifacts , Computer-Aided Design , Gravitation , Lenses , Models, Theoretical , Optical Devices , Telescopes , Computer Simulation , Equipment Design , Equipment Failure Analysis , Light , Quantum Theory , Scattering, Radiation
16.
Phys Rev Lett ; 104(25): 251102, 2010 Jun 25.
Article in English | MEDLINE | ID: mdl-20867358

ABSTRACT

Only a few years ago, it was realized that the zero-area Sagnac interferometer topology is able to perform quantum nondemolition measurements of position changes of a mechanical oscillator. Here, we experimentally show that such an interferometer can also be efficiently enhanced by squeezed light. We achieved a nonclassical sensitivity improvement of up to 8.2 dB, limited by optical loss inside our interferometer. Measurements performed directly on our squeezed-light laser output revealed squeezing of 12.7 dB. We show that the sensitivity of a squeezed-light enhanced Sagnac interferometer can surpass the standard quantum limit for a broad spectrum of signal frequencies without the need for filter cavities as required for Michelson interferometers. The Sagnac topology is therefore a powerful option for future gravitational-wave detectors, such as the Einstein Telescope, whose design is currently being studied.

17.
Opt Lett ; 35(10): 1665-7, 2010 May 15.
Article in English | MEDLINE | ID: mdl-20479843

ABSTRACT

The injection of squeezed light can be used to improve the sensitivity of an interferometer beyond the limit imposed by the zero-point fluctuation of the electromagnetic field. Here, we report on the realization of such a quantum-enhanced interferometer with a fiber-based Sagnac topology. Continuous wave squeezed states at 1550 nm with a noise reduction of 6.4 dB below shot noise were produced by type I optical parametric amplification and subsequently injected into the dark port of the interferometer. A reduction of the interferometer shot noise by 4.5 dB was observed, and the enhancement of the signal-to-noise ratio for a phase modulation signal generated within the interferometer could be demonstrated. We achieved a 95% fiber transmission for the squeezed states, which suggests that corresponding fiber-based quantum metrology and communication systems are feasible.

18.
Opt Lett ; 34(7): 1060-2, 2009 Apr 01.
Article in English | MEDLINE | ID: mdl-19340219

ABSTRACT

We report on the generation of cw squeezed vacuum states of light at the telecommunication wavelength of 1550 nm. The squeezed vacuum states were produced by type I optical parametric amplification in a standing-wave cavity built around a periodically poled potassium titanyl phosphate crystal. A nonclassical noise reduction of 5.3 dB below the shot noise was observed by means of balanced homodyne detection.

19.
Opt Lett ; 34(6): 824-6, 2009 Mar 15.
Article in English | MEDLINE | ID: mdl-19282945

ABSTRACT

Twin-Signal-Recycling (TSR) builds on the resonance doublet of two optically coupled cavities and efficiently enhances the sensitivity of an interferometer at a dedicated signal frequency. We report on what we believe to be the first experimental realization of a TSR Michelson interferometer and also its broadband enhancement by squeezed light injection. The complete setup was stably locked, and a broadband quantum noise reduction of the interferometers shot noise by a factor of up to 4 dB was demonstrated. The system was characterized by measuring its quantum noise spectra for several tunings of the TSR cavities. We found good agreement between the experimental results and numerical simulations.

20.
Phys Rev Lett ; 100(24): 243601, 2008 Jun 20.
Article in English | MEDLINE | ID: mdl-18643584

ABSTRACT

We have experimentally demonstrated how two beams of light separated by an octave in frequency can become entangled after their interaction in a chi;{(2)} nonlinear medium. The entangler was a nonlinear optical resonator that was strongly driven by coherent light at the fundamental and second-harmonic wavelengths. An interconversion between the fields created quantum correlations in the amplitude and phase quadratures, which were measured by two independent homodyne detectors. Analysis of the resulting correlation matrix revealed a wave function inseparability of 0.74(1)<1, thereby satisfying the criterion of entanglement.