Rev Sci Instrum ; 93(9): 093527, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36182470

ABSTRACT

Capacitive plasma pickup is a well-known and difficult problem for plasma-facing edge diagnostics. This problem must be addressed to ensure an accurate and robust interpretation of the real signal measurements vs noise. The Faraday cup fast ion loss detector array of the Joint European Torus (JET) is particularly prone to this issue and can be used as a testbed to prototype solutions. The issue of separation and distinction between warranted fast ion signal and electromagnetic plasma noise has traditionally been solved with hardware modifications, but a more versatile post-processing approach is of great interest. This work presents post-processing techniques to characterize the signal noise. While hardware changes and advancements may be limited, the combination with post-processing procedures allows for more rapid and robust analysis of measurements. The characterization of plasma pickup noise is examined for alpha losses in a discharge from JET's tritium campaign. In addition to highlighting the post-processing methodology, the spatial sensitivity of the detector array is also examined, which presents significant advantages for the physical interpretation of fast ion losses.

2.
Rev Sci Instrum ; 89(10): 10K107, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399841

ABSTRACT

Since 2010, an in-vessel calibration light source (ICLS) has been used periodically on JET to calibrate a range of diagnostics at UV, visible, and IR wavelengths. During shutdowns, the ICLS (which is essentially an integrating sphere) is positioned within the vacuum vessel by the remote handling (RH) system. Following the 2013 calibration runs, several changes were made to improve the efficiency and quality of the calibrations. Among these was the replacement of a 20 m "umbilical" cable which carried power and other electrical signals through a vessel port to/from a control cubicle. A lightweight 2 m cable now plugs directly into a single connector on the RH manipulator system, greatly reducing the time required for deployment and improving operational flexibility; e.g., the vessel access "floor" no longer needs to be installed. This change also means the system would be compatible with calibrations after a high neutron-fluence period of operation. An on-board micro-spectrometer now allows for real-time verification of the emitted spectrum. Finally, new "baffles" were designed and installed within the integrating sphere itself, greatly improving the spectral radiance uniformity at non-normal viewing angles (necessary due to orientation uncertainties with the RH system).

3.
Rev Sci Instrum ; 89(10): 10D113, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399852

ABSTRACT

Charge-exchange spectroscopy on JET has become particularly challenging with the introduction of the ITER-like wall. The line intensities are weaker and contaminated by many nuisance lines. We have therefore upgraded the instrumentation to improve throughput and allow the simultaneous measurement of impurity and fuel-ion charge exchange by splitting the light between two pairs of imaging spectrometers using dichroic beam splitters. Imaging instruments allow us to stack 11 × 1 mm diameter fibres on the entrance slits without cross talk. CCD cameras were chosen to have 512 × 512 pixels to allow frame transfer times <0.2 ms which with minimum exposure times of 5 ms give tolerable smearing even without a chopper. The image plane is optically demagnified 2:1 to match the sensor size of these cameras. Because the image plane of the spectrometer is tilted, the CCD must also be tilted to maintain focus over the spectrum (Scheimpflug condition). To avoid transverse keystoning (causing the vertical height of the spectra to change across the sensor), the configuration is furthermore designed to be telecentric by a suitable choice of the lens separation. The lens configuration is built almost entirely from commercial off-the-shelf components, which allowed it to be assembled and aligned relatively rapidly to meet the deadline for in-vessel calibration in the JET shutdown.

5.
Rev Sci Instrum ; 87(11): 11D430, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910322

ABSTRACT

The in situ absolute calibration of the JET real-time protection imaging system has been performed for the first time by means of radiometric light source placed inside the JET vessel and operated by remote handling. High accuracy of the calibration is confirmed by cross-validation of the near infrared (NIR) cameras against each other, with thermal IR cameras, and with the beryllium evaporator, which lead to successful protection of the JET first wall during the last campaign. The operation temperature ranges of NIR protection cameras for the materials used on JET are Be 650-1600 °C, W coating 600-1320 °C, and W 650-1500 °C.

6.
Rev Sci Instrum ; 85(11): 11E432, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25430339

ABSTRACT

The mirror-linked divertor spectroscopy diagnostic on JET has been upgraded with a new visible and near-infrared grating and filtered spectroscopy system. New capabilities include extended near-infrared coverage up to 1875 nm, capturing the hydrogen Paschen series, as well as a 2 kHz frame rate filtered imaging camera system for fast measurements of impurity (Be II) and deuterium Dα, Dß, Dγ line emission in the outer divertor. The expanded system provides unique capabilities for studying spatially resolved divertor plasma dynamics at near-ELM resolved timescales as well as a test bed for feasibility assessment of near-infrared spectroscopy.

7.
Rev Sci Instrum ; 84(10): 103508, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24188275

ABSTRACT

One of the main approaches to thermonuclear fusion relies on confining high temperature plasmas with properly shaped magnetic fields. The determination of the magnetic topology is, therefore, essential for controlling the experiments and for achieving the required performance. In Tokamaks, the reconstruction of the fields is typically formulated as a free boundary equilibrium problem, described by the Grad-Shafranov equation in toroidal geometry and axisymmetric configurations. Unfortunately, this results in mathematically very ill posed problems and, therefore, the quality of the equilibrium reconstructions depends sensitively on the measurements used as inputs and on the imposed constraints. In this paper, it is shown how the different diagnostics (Magnetics Measurements, Polarimetry and Motional Stark Effect), together with the edge current density and plasma pressure constraints, can have a significant impact on the quality of the equilibrium on JET. Results show that both the Polarimetry and Motional Stark Effect internal diagnostics are crucial in order to obtain reasonable safety factor profiles. The impact of the edge current density constraint is significant when the plasma is in the H-mode of confinement. In this plasma scenario the strike point positions and the plasma last closed flux surface can change even by centimetres, depending on the edge constraints, with a significant impact on the remapping of the equilibrium-dependent diagnostics and of pedestal physics studies. On the other hand and quite counter intuitively, the pressure constraint can severely affect the quality of the magnetic reconstructions in the core. These trends have been verified with several JET discharges and consistent results have been found. An interpretation of these results, as interplay between degrees of freedom and available measurements, is provided. The systematic analysis described in the paper emphasizes the importance of having sufficient diagnostic inputs and of properly validating the results of the codes with independent measurements.

8.
Rev Sci Instrum ; 83(10): 10D517, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23130791

ABSTRACT

In preparation for ITER, JET has been upgraded with a new ITER-like wall (ILW), whereby the main plasma facing components, previously of carbon, have been replaced by mainly Be in the main chamber and W in the divertor. As part of the many diagnostic enhancements, a new, survey, visible spectroscopy diagnostic has been installed for the characterization of the ILW. An array of eight lines-of-sight (LOS) view radially one of the two JET neutral beam shine through areas (W coated carbon fibre composite tiles) at the inner wall. In addition, one vertical LOS views the solid W tile at the outer divertor. The light emitted from the plasma is coupled to a series of compact overview spectrometers, with overall wavelength range of 380-960 nm and to one high resolution Echelle overview spectrometer covering the wavelength range 365-720 nm. The new survey diagnostic has been absolutely calibrated in situ by means of a radiometric light source placed inside the JET vessel in front of the whole optical path and operated by remote handling. The diagnostic is operated in every JET discharge, routinely monitoring photon fluxes from intrinsic and extrinsic impurities (e.g., Be, C, W, N, and Ne), molecules (e.g., BeD, D(2), ND) and main chamber and divertor recycling (typically Dα, Dß, and Dγ). The paper presents a technical description of the diagnostic and first measurements during JET discharges.

9.
Rev Sci Instrum ; 81(10): 10D733, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21061477

ABSTRACT

A 60 kV neutral Li beam is injected into the edge plasma of JET to measure the electron density. The beam observation system has been improved by replacing a Czerny-Turner spectrometer with a high-resolution transmission-grating spectrometer and a fast back-illuminated frame-transfer camera. The larger throughput of the spectrometer, the increased sensitivity, and the faster readout of the new camera allow inter-ELM (edge localized mode) measurements (frame rate of 100 Hz). The calibration of the setup, as well as an improved spectral fitting technique in the presence of carbon background radiation, is discussed in detail. The density calculation is based on a statistical analysis method. Results are presented for different plasma scenarios.

10.
Rev Sci Instrum ; 81(10): 10E532, 2010 Oct.
Article in English | MEDLINE | ID: mdl-21061729

ABSTRACT

Since 1994, JET has had a mirror-link spectroscopy system with a poloidal view of 150 mm of the outer divertor split into three ranges: near-ultraviolet (near-UV) (∼ 300­450 nm), visible (450­750 nm), and near-infrared (near-IR) (750­1200 nm). The system consists of three Czerny­Turner/charge coupled device (CCD) pairs: 1 m focal length for the near-UV, 0.75 m focal length for the visible, and 0.5 m focal length for the near-IR. All were aligned along the same optical path to the divertor. As part of the JET ITER-like wall enhancements, the diagnostic system will be upgraded in five areas: (1) frame rate, (2) quantum efficiency (QE), (3) radial coverage, (4) optical throughput, and (5) for the near-UV, spectral resolution and survey capability. New CCDs for the near-UV and visible will have increased QE and allow three times frame rate. The near-UV will benefit from a 0.75 m imaging spectrometer with three gratings. The optics have been redesigned to allow ∼ 360 mm view and greater than two times throughput. This paper will look at the design and implementation as well as the new diagnostic capabilities of the system.

11.
Rev Sci Instrum ; 79(10): 10F525, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19068535

ABSTRACT

The core charge-exchange diagnostic at the Joint European Torus (JET) provides measurements of the impurity ion temperature T(i), toroidal velocity V(phi), and impurity ion densities n(imp), across the whole minor radius. A contribution to the uncertainty of the measured quantities is the error resulting from the multi-Gaussian fit and photon statistics, usually quoted for each measured data. Absolute intensity calibration and especially alignment of the viewing directions can introduce an important systematic error. The technique adopted at JET to reduce this systematic contribution to the error is presented in this paper. The error in T(i), V(phi), and n(imp) is then discussed depending on their use.

12.
Phys Rev Lett ; 92(23): 235001, 2004 Jun 11.
Article in English | MEDLINE | ID: mdl-15245162

ABSTRACT

Changes of the toroidal plasma rotation induced by directed waves in the ion-cyclotron range of frequencies (ICRF) have been identified experimentally for the first time on the JET tokamak. The momentum carried by the waves is initially absorbed by fast resonating ions, which subsequently transfer it to the bulk plasma. Thus, the results provide evidence for the influence of ICRF heated fast ions on plasma rotation.