Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 46
Filter
1.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38030358

ABSTRACT

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thromboembolism , Thrombosis , Humans , Female , Incidence , Atrial Appendage/diagnostic imaging , Treatment Outcome , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Thromboembolism/diagnostic imaging , Thromboembolism/epidemiology , Thromboembolism/etiology , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Thrombosis/etiology , Stroke/etiology
3.
Catheter Cardiovasc Interv ; 102(2): 283-292, 2023 08.
Article in English | MEDLINE | ID: mdl-37393575

ABSTRACT

BACKGROUND: Women with atrial fibrillation (AF) generally experience worse symptoms, poorer quality of life, and have a higher risk of stroke and death. There is limited availability of sex-related differences regarding left atrial appendage occlusion (LAAO). AIMS: The aim of this study was to evaluate the sex-related differences in patients undergoing LAAO in EWOLUTION. METHODS: A total of 1025 patients scheduled for elective LAAO therapy employing the WATCHMAN Gen 2.5 prospectively consented for participation; 1005 patients received a successful implant and were followed for 2 years. As we detected sex-related differences in baseline data we performed a propensity score matching. The primary endpoint is a combined endpoint of survival free from mortality, major bleeding, ischemic stroke, transitory ischemic attack (TIA) and systemic embolization (SE) up to 2-year clinical follow-up. Secondary Endpoints were periprocedural data and overall 2-year survival. RESULTS: Women were older but had less often vascular disease and hemorrhagic stroke. There was no sex-related significant difference after LAAO at 2 years in the combined endpoint of survival free from mortality, major bleeding, ischemic stroke, TIA, and SE (female vs. male: 79% vs.76%, p = 0.24) or in overall survival (female vs. male: 85% vs. 82%, p = 0.16). Procedural data showed a higher sealing rate after the implantation in women (complete sealing female 94% vs. male 90%, p = 0.033), significantly more pericardial effusions (female 1.2% vs. male 0.2%, p = 0.031) and a similar periprocedural risk profile. CONCLUSIONS: Females undergoing LAAO differ in various baseline variables, but after adjustment, we observed similar safety and efficacy of LAAO with no significant difference in long-term outcomes between women and men.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Ischemic Attack, Transient , Ischemic Stroke , Stroke , Humans , Male , Female , Treatment Outcome , Atrial Appendage/diagnostic imaging , Ischemic Attack, Transient/etiology , Quality of Life , Stroke/etiology , Stroke/prevention & control , Europe , Hemorrhage , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Registries
4.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37294311

ABSTRACT

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thrombosis , Humans , Treatment Outcome , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Thrombosis/diagnosis , Thrombosis/epidemiology , Thrombosis/etiology , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Registries , Atrial Appendage/diagnostic imaging
5.
Herz ; 48(4): 292-300, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35397659

ABSTRACT

BACKGROUND: Polymer-free and carrier-free drug-coated stents (DCS) represent a novel therapeutic option for the treatment of coronary artery disease. The objective of this pilot registry is to evaluate the safety and efficacy of DCS implantation in bifurcation lesions. METHODS: Overall, 23 consecutive patients with 24 lesions received a Biolimus A9-coated DCS for coronary bifurcation lesions. Patients were examined with quantitative coronary angiography (QCA) and optical coherence tomography (OCT) at 3-6 months of follow-up. RESULTS: A total of 23 patients with 24 bifurcation lesions were included in this study. Nine (33.3%) lesions of eight patients revealed angiographical target lesion failure due to in-stent restenosis (ISR). In total, 19 patients with 20 bifurcation lesions were suitable for OCT analysis. A total of 2936 struts were analyzed and 14 struts (0.47%) were classified as malapposed. The mean luminal area (mm2) was not different in lesions with ISR vs. lesions with no ISR (5.07 ± 2.0 vs. 5.73 ± 1.34, p = 0.39) at follow-up. Lesions with ISR showed higher mean neointimal burden (27.11 ± 10.59 vs. 13.93 ± 9.16%, respectively; p = 0.009). All of the patients who presented with significant ISR required percutaneous re-intervention. CONCLUSIONS: We observed a high rate of DCS ISR in bifurcation lesions, possibly related to increased inflammation and neoatherosclerosis. The small size of the study warrants careful interpretation of our results. Larger trials are necessary to expand knowledge of these findings.


Subject(s)
Coronary Artery Disease , Coronary Restenosis , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Tomography, Optical Coherence , Coronary Vessels , Treatment Outcome , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Coronary Angiography , Registries , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/therapy
6.
Clin Res Cardiol ; 111(11): 1276-1285, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35849156

ABSTRACT

BACKGROUND: Data on Device-related Thrombus (DRT) after left atrial appendage closure (LAAC) remain scarce. This study aimed to investigate risk factors for DRT from centers reporting to the EUROC-DRT registry. METHODS: We included 537 patients (112 with DRT and 425 without DRT) who had undergone LAAC between 12/2008 and 04/2019. Baseline and implantation characteristics, anti-thrombotic treatment and clinical outcomes were compared between both groups in uni- and multivariate analyses. Additional propensity-score matching (PSM) was conducted to focus on the role of implantation characteristics. RESULTS: Patients with DRT showed higher rates of previous stroke/transient ischemic attack (TIA) (49.1% vs. 34.7%, p < 0.01), spontaneous echocardiographic contrast (SEC) (44.9% vs. 27.7%, p < 0.01) and lower left atrial appendage (LAA) peak emptying velocity (35.4 ± 18.5 vs. 42.4 ± 18.0 cm/s, p = 0.02). Occluders implanted in DRT patients were larger (25.5 ± 3.8 vs. 24.6 ± 3.5 mm, p = 0.03) and implanted deeper in the LAA (mean depth: 7.6 ± 4.7 vs. 5.7 ± 4.7 mm, p < 0.01). Coverage of the appendage ostium was achieved less often in DRT patients (69.5% vs. 81.5%, p < 0.01), while DRT patients were less frequently on oral anticoagulation (7.1% vs. 16.7%, p < 0.01). Multivariate analysis identified age, prior stroke/TIA and SEC as independent risk factors for DRT. After PSM, implantation depth was found to be predictive. Rates of stroke/TIA were higher in DRT patients (13.5% vs. 3.8%, Hazard Ratio: 4.21 [95%-confidence interval: 1.88-9.49], p < 0.01). CONCLUSIONS: DRT after LAAC is associated with adverse outcome and appears to be of multifactorial origin, depending on patient characteristics, anticoagulation regimen and device position.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Ischemic Attack, Transient , Stroke , Thrombosis , Humans , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Treatment Outcome , Thrombosis/diagnosis , Thrombosis/epidemiology , Thrombosis/etiology , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology , Risk Factors , Echocardiography , Registries , Anticoagulants/therapeutic use
7.
J Invasive Cardiol ; 34(5): E348-E355, 2022 05.
Article in English | MEDLINE | ID: mdl-35501111

ABSTRACT

BACKGROUND: Left atrial appendage occlusion (LAAO) is recommended for patients with atrial fibrillation at increased stroke risk, where effective long-term oral anticoagulation (OAC) is not feasible. In order to assess long-term safety of LAAO with aspirin monotherapy or no therapy, we aimed to report on patients with the Watchman LAAO device (Boston Scientific) once postimplantation intensified antiplatelet or anticoagulation therapy is discontinued. METHODS: A total of 1025 patients scheduled for elective LAAO therapy prospectively consented for participation in the EWOLUTION registry; 1005 patients received a successful implant and were followed for 2 years. We identified 766 patients in EWOLUTION on single-antiplatelet therapy (SAPT; n = 639) or no therapy (n = 127) for ≥1 year following LAAO. RESULTS: Three to 6 months after LAAO, 766 patients were switched to SAPT or no therapy and were followed for at least 1 year until the study's conclusion or with events while on SAPT/ no therapy; mean time on SAPT/no therapy was 536.56 ± 177.59 days. Patients experienced 1.4 ischemic strokes per 100 patient years (PY) despite a CHA2DS2-VASC score of 4.3 ± 1.6. Major nonprocedural bleeding rates were low, with 1.3 major bleeds per 100 PY with a mean HAS-BLED score of 2.2 ± 1.2. Furthermore, the ischemic stroke rate in the SAPT/no-therapy subgroup was similar to the whole EWOLUTION collective and high-risk subgroups; the bleeding rate was even lower. When analyzed separately, strokes (2.1/100 PY) and bleedings (1.4/100 PY) of the no-therapy subgroup were similar to patients on SAPT (strokes 0.7/100 PY [P=.70]; bleedings 1.4/100 PY [P=.90]). CONCLUSIONS: Outcome data of patients on SAPT/no therapy for ≥1 year following Watchman implantation in the EWOLUTION registry suggest the efficacy and safety of LAAO.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Anticoagulants/adverse effects , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Hemorrhage/prevention & control , Humans , Registries , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Treatment Outcome
8.
Heart Rhythm ; 19(6): 917-926, 2022 06.
Article in English | MEDLINE | ID: mdl-35181483

ABSTRACT

BACKGROUND: The new-generation WATCHMAN FLX (Boston Scientific) device for left atrial appendage occlusion has been modified in various aspects to improve procedural results. No comparison of the WATCHMAN FLX device with the previous WATCHMAN device is available. OBJECTIVE: We aimed to compare procedural results with WATCHMAN FLX in patients on dual antiplatelet therapy at ∼3 months with data with WATCHMAN (EWOLUTION [Registry on WATCHMAN Outcomes in Real-Life Utilization]). METHODS: One hundred sixty-four consecutive patients receiving the WATCHMAN FLX device in 4 European centers were included in the retrospective ALSTER-FLX registry. As a control group for a matched-pair analysis, 1020 patients treated with the WATCHMAN device and data up to first follow-up (∼3 months) from EWOLUTION were used. RESULTS: Implantation was successful in all ALSTER-FLX patients (100%) and similar to results in EWOLUTION (99%) (P = .2). We observed no stroke or device embolization in ALSTER-FLX similar to EWOLUTION (stroke 0.5%, device embolization 0.4%) at 3 months. Numerically less ALSTER-FLX patients (2.4%) developed a device-associated thrombus as compared with 3.7% EWOLUTION patients, yet without reaching statistical significance after matching (median [95% confidence interval] device-associated thrombus pairwise event difference 2 [0-6]; P = .1). WATCHMAN FLX implantation was associated with a significant higher sealing rate compared with EWOLUTION at 3 months (ALSTER-FLX 90% vs EWOLUTION 79.4%; P = .039 after matching). Major nonprocedural bleeding events and mortality were similar after matching (median event difference for bleeding 0 [-3 to 3]; P = .6 and death 1 [-2 to 4]; P = .3). CONCLUSION: Periprocedural, early 3-month outcomes with WATCHMAN FLX demonstrate a similar safety profile and an improved sealing rate compared to the WATCHMAN device.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thrombosis , Atrial Appendage/surgery , Cardiac Catheterization , Humans , Matched-Pair Analysis , Registries , Retrospective Studies , Stroke/etiology , Thrombosis/etiology , Treatment Outcome
9.
N Engl J Med ; 385(23): 2150-2160, 2021 12 02.
Article in English | MEDLINE | ID: mdl-34449183

ABSTRACT

BACKGROUND: The role of direct oral anticoagulants as compared with vitamin K antagonists for atrial fibrillation after successful transcatheter aortic-valve replacement (TAVR) has not been well studied. METHODS: We conducted a multicenter, prospective, randomized, open-label, adjudicator-masked trial comparing edoxaban with vitamin K antagonists in patients with prevalent or incident atrial fibrillation as the indication for oral anticoagulation after successful TAVR. The primary efficacy outcome was a composite of adverse events consisting of death from any cause, myocardial infarction, ischemic stroke, systemic thromboembolism, valve thrombosis, or major bleeding. The primary safety outcome was major bleeding. On the basis of a hierarchical testing plan, the primary efficacy and safety outcomes were tested sequentially for noninferiority, with noninferiority of edoxaban established if the upper boundary of the 95% confidence interval for the hazard ratio did not exceed 1.38. Superiority testing of edoxaban for efficacy would follow if noninferiority and superiority were established for major bleeding. RESULTS: A total of 1426 patients were enrolled (713 in each group). The mean age of the patients was 82.1 years, and 47.5% of the patients were women. Almost all the patients had atrial fibrillation before TAVR. The rate of the composite primary efficacy outcome was 17.3 per 100 person-years in the edoxaban group and 16.5 per 100 person-years in the vitamin K antagonist group (hazard ratio, 1.05; 95% confidence interval [CI], 0.85 to 1.31; P = 0.01 for noninferiority). Rates of major bleeding were 9.7 per 100 person-years and 7.0 per 100 person-years, respectively (hazard ratio, 1.40; 95% CI, 1.03 to 1.91; P = 0.93 for noninferiority); the difference between groups was mainly due to more gastrointestinal bleeding with edoxaban. Rates of death from any cause or stroke were 10.0 per 100 person-years in the edoxaban group and 11.7 per 100 person-years in the vitamin K antagonist group (hazard ratio, 0.85; 95% CI, 0.66 to 1.11). CONCLUSIONS: In patients with mainly prevalent atrial fibrillation who underwent successful TAVR, edoxaban was noninferior to vitamin K antagonists as determined by a hazard ratio margin of 38% for a composite primary outcome of adverse clinical events. The incidence of major bleeding was higher with edoxaban than with vitamin K antagonists. (Funded by Daiichi Sankyo; ENVISAGE-TAVI AF ClinicalTrials.gov number, NCT02943785.).


Subject(s)
4-Hydroxycoumarins/therapeutic use , Atrial Fibrillation/drug therapy , Factor Xa Inhibitors/therapeutic use , Pyridines/therapeutic use , Thiazoles/therapeutic use , Transcatheter Aortic Valve Replacement , Vitamin K/antagonists & inhibitors , 4-Hydroxycoumarins/adverse effects , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Factor Xa Inhibitors/adverse effects , Female , Gastrointestinal Hemorrhage/chemically induced , Humans , Intention to Treat Analysis , Kaplan-Meier Estimate , Male , Mortality , Phenindione/analogs & derivatives , Phenindione/therapeutic use , Postoperative Complications/prevention & control , Pyridines/adverse effects , Thiazoles/adverse effects , Thromboembolism/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects
10.
J Am Coll Cardiol ; 78(4): 297-313, 2021 07 27.
Article in English | MEDLINE | ID: mdl-34294267

ABSTRACT

BACKGROUND: Device-related thrombus (DRT) has been considered an Achilles' heel of left atrial appendage occlusion (LAAO). However, data on DRT prediction remain limited. OBJECTIVES: This study constructed a DRT registry via a multicenter collaboration aimed to assess outcomes and predictors of DRT. METHODS: Thirty-seven international centers contributed LAAO cases with and without DRT (device-matched and temporally related to the DRT cases). This study described the management patterns and mid-term outcomes of DRT and assessed patient and procedural predictors of DRT. RESULTS: A total of 711 patients (237 with and 474 without DRT) were included. Follow-up duration was similar in the DRT and no-DRT groups, median 1.8 years (interquartile range: 0.9-3.0 years) versus 1.6 years (interquartile range: 1.0-2.9 years), respectively (P = 0.76). DRTs were detected between days 0 to 45, 45 to 180, 180 to 365, and >365 in 24.9%, 38.8%, 16.0%, and 20.3% of patients. DRT presence was associated with a higher risk of the composite endpoint of death, ischemic stroke, or systemic embolization (HR: 2.37; 95% CI, 1.58-3.56; P < 0.001) driven by ischemic stroke (HR: 3.49; 95% CI: 1.35-9.00; P = 0.01). At last known follow-up, 25.3% of patients had DRT. Discharge medications after LAAO did not have an impact on DRT. Multivariable analysis identified 5 DRT risk factors: hypercoagulability disorder (odds ratio [OR]: 17.50; 95% CI: 3.39-90.45), pericardial effusion (OR: 13.45; 95% CI: 1.46-123.52), renal insufficiency (OR: 4.02; 95% CI: 1.22-13.25), implantation depth >10 mm from the pulmonary vein limbus (OR: 2.41; 95% CI: 1.57-3.69), and non-paroxysmal atrial fibrillation (OR: 1.90; 95% CI: 1.22-2.97). Following conversion to risk factor points, patients with ≥2 risk points for DRT had a 2.1-fold increased risk of DRT compared with those without any risk factors. CONCLUSIONS: DRT after LAAO is associated with ischemic events. Patient- and procedure-specific factors are associated with the risk of DRT and may aid in risk stratification of patients referred for LAAO.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization/adverse effects , Postoperative Complications/etiology , Registries , Septal Occluder Device/adverse effects , Thrombosis/etiology , Aged , Atrial Appendage/diagnostic imaging , Echocardiography, Transesophageal , Europe/epidemiology , Female , Follow-Up Studies , Heart Diseases/diagnosis , Heart Diseases/epidemiology , Heart Diseases/etiology , Humans , Incidence , Male , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Risk Factors , Survival Rate/trends , Thrombosis/diagnosis , Thrombosis/epidemiology , Time Factors , Treatment Outcome
11.
Int J Cardiovasc Imaging ; 37(10): 2947-2955, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34046774

ABSTRACT

Iatrogenic mitral stenosis following transcatheter mitral valve repair (TMVR) for relevant mitral regurgitation (MR) is a potential adverse side-effect, known to affect long-term outcome. However, only few determinants of an elevated mean transmitral pressure gradient (TMPG) have been described thus far. We sought to develop an integrative model for the prediction of TMPG following MitraClip (MC) therapy. From 01/2013 to 03/2017, a total of 175 consecutive patients were successfully (MR ≤ 2 + at discharge) treated with a MitraClip implantation at our centre. Of these, a total of 148 patients (54% male, 77.0 ± 6.0 years, 58% with secondary MR) had complete echocardiographic data sets comprising pre- and postinterventional two- and three-dimensional transthoracic (TTE) and transoesophageal (TOE) echocardiograms. Comprehensive studies of predefined parameters were performed. An expert-based prediction model including preprocedural variables (annular ellipticity, mitral valve commissure-to-commissure diameter, preprocedural transmitral pressure gradient and MR aetiology) was set up and validated with a total of 200 bootstrap samples. A nomogram was developed to predict the postprocedural TMPG based on selected echocardiographic variables. Introduction of nomogram-based guiding of MC therapy could help identify patients at risk for postprocedural mitral stenosis, have an influence on preprocedural patient selection and intraprocedural decision making.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Cardiac Catheterization/adverse effects , Echocardiography , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Predictive Value of Tests , Retrospective Studies , Treatment Outcome
12.
J Invasive Cardiol ; 33(5): E356-E364, 2021 05.
Article in English | MEDLINE | ID: mdl-33932281

ABSTRACT

OBJECTIVES: Both balloon-expandable and self-expanding transcatheter aortic valves are used for transcatheter aortic valve implantation (TAVI). We compared procedural and clinical outcome variables of Sapien 3 and Evolut R/Pro in an all-comers collective. METHODS: In this single-center registry, patients were consecutively treated with the Sapien 3 from November 2014 to March 2017 (n = 129) and from April 2017 to December 2018 mainly (>95%) with the Evolut R/Pro (n = 124), due to a switch in the main TAVI supplier driven by hospital management. Data were retrospectively analyzed before and after the switch. RESULTS: One-year follow-up data were available for 122 (94%) of the Sapien and 112 (90%) of the Evolut patients. Baseline characteristics were comparable (EuroSCORE: Sapien 21.8 ± 0.9% vs Evolut 22.5 ± 0.8%; P=.20). Evolut implantation was associated with a higher radiation dose (Sapien 35770 ± 2345 mGy•cm² vs Evolut 85072 ± 8202 mGy•cm²; P<.001), more postimplantation balloon dilations (Sapien 17.1% vs Evolut 37.1%; P<.001), but similar procedure time (Sapien 75.2 ± 3.8 min vs Evolut 74.6 ± 3 min; P=.30). In-hospital mortality (Sapien 3.1% vs Evolut 4.0%; P=.70), all-cause mortality (Sapien 13.2% vs Evolut 15.3%; P=.70), all-stroke rate (Sapien 1.5% vs Evolut 6.5%; P=.05), and pacemaker implantation rate (Sapien 13.2% vs Evolut 18.5%; P=.30) were similar at 1 year. Permanent pacemaker rate was numerically higher in the first 6 months with Evolut (<6 months 26.7% vs >6 months 16%; P=.62); furthermore, radiation dose and balloon dilations also suggest a learning curve with Evolut. CONCLUSIONS: Switching from Sapien 3 to Evolut R/Pro was not associated with a difference regarding periprocedural or 1-year clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Registries , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Circ Cardiovasc Interv ; 14(5): e010195, 2021 05.
Article in English | MEDLINE | ID: mdl-34003661

ABSTRACT

BACKGROUND: Left atrial appendage closure is an established therapy in patients with atrial fibrillation. Although device-related thrombosis (DRT) is relatively rare, it is potentially linked to adverse events. As data on DRT characteristics, outcome, and treatment regimen are scarce, we aimed to assess these questions in a multicenter approach. METHODS: One hundred fifty-six patients with the diagnosis of DRT after left atrial appendage closure were included in the multinational EUROC-DRT registry. Baseline characteristics included clinical and echocardiographic data. After inclusion, all patients underwent further clinical and echocardiographic follow-up to assess DRT dynamics, treatment success, and outcome. RESULTS: DRT was detected after a median of 93 days (interquartile range, 54­161 days) with 17.9% being detected >6 months after left atrial appendage closure. Patients with DRT were at high ischemic and bleeding risk (CHA2DS2-VASc 4.5±1.7, HAS-BLED 3.3±1.2) and had nonparoxysmal atrial fibrillation (67.3%), previous stroke (53.8%), and spontaneous echo contrast (50.6%). The initial treatment regimens showed comparable resolution rates (antiplatelet monotherapy: 57.1%, dual antiplatelet therapy: 85.7%, vitamin K antagonists: 80.0%, novel oral anticoagulants: 75.0%, and heparin: 68.6%). After intensification or switch of treatment, complete DRT resolution was achieved in 79.5% of patients. Two-year follow-up revealed a high risk of mortality (20.0%) and ischemic stroke (13.8%) in patients with DRT. Patients with incomplete DRT resolution showed numerically higher stroke rates and increased mortality rates (stroke: 17.6% versus 12.3%, P=0.29; mortality: 31.3% versus 13.1%, P=0.05). CONCLUSIONS: A substantial proportion of DRT is detected >6 months after left atrial appendage closure, highlighting the need for imaging follow-up. Patients with DRT appear to be at a high risk for stroke and mortality. While DRT resolution was achieved in most patients, incomplete DRT resolution appeared to identify patients at even higher risk. Optimal DRT diagnostic criteria and treatment regimens are warranted.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thrombosis , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Humans , Registries , Stroke/diagnostic imaging , Stroke/etiology , Stroke/therapy , Thrombosis/diagnostic imaging , Thrombosis/etiology , Thrombosis/therapy , Treatment Outcome
14.
Am Heart J ; 234: 1-11, 2021 04.
Article in English | MEDLINE | ID: mdl-33428901

ABSTRACT

BACKGROUND: In acute myocardial infarction complicated by cardiogenic shock the use of mechanical circulatory support devices remains controversial and data from randomized clinical trials are very limited. Extracorporeal life support (ECLS) - venoarterial extracorporeal membrane oxygenation - provides the strongest hemodynamic support in addition to oxygenation. However, despite increasing use it has not yet been properly investigated in randomized trials. Therefore, a prospective randomized adequately powered clinical trial is warranted. STUDY DESIGN: The ECLS-SHOCK trial is a 420-patient controlled, international, multicenter, randomized, open-label trial. It is designed to compare whether treatment with ECLS in addition to early revascularization with percutaneous coronary intervention or alternatively coronary artery bypass grafting and optimal medical treatment is beneficial in comparison to no-ECLS in patients with severe infarct-related cardiogenic shock. Patients will be randomized in a 1:1 fashion to one of the two treatment arms. The primary efficacy endpoint of ECLS-SHOCK is 30-day mortality. Secondary outcome measures such as hemodynamic, laboratory, and clinical parameters will serve as surrogate endpoints for prognosis. Furthermore, a longer follow-up at 6 and 12 months will be performed including quality of life assessment. Safety endpoints include peripheral ischemic vascular complications, bleeding and stroke. CONCLUSIONS: The ECLS-SHOCK trial will address essential questions of efficacy and safety of ECLS in addition to early revascularization in acute myocardial infarction complicated by cardiogenic shock.


Subject(s)
Extracorporeal Membrane Oxygenation , Myocardial Infarction/therapy , Myocardial Revascularization/methods , Coronary Artery Bypass/methods , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/methods , Fibrinolytic Agents/therapeutic use , Humans , Myocardial Infarction/complications , Myocardial Infarction/mortality , Prognosis , Prospective Studies , Quality of Life , Sample Size , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality
15.
EuroIntervention ; 16(17): 1447-1454, 2021 Apr 20.
Article in English | MEDLINE | ID: mdl-33074154

ABSTRACT

AIMS: Failure of transcatheter mitral valve repair (fTMVR) therapy has a decisive prognostic influence, and complex retreatment is of higher risk. The aim of this analysis was to evaluate the survival outcome following percutaneous procedures and surgery after unsuccessful TMVR interventions for different aetiologies. METHODS AND RESULTS: Of 824 consecutive patients who had been treated with the MitraClip device at our institution, between September 2009 and May 2019, 63 (7.6%) symptomatic patients with therapy failure and persistent or recurrent mitral regurgitation (MR) underwent reinterventions. An outcome analysis for primary (PMR) and secondary mitral regurgitation (SMR) and subsequent percutaneous versus surgical treatment was carried out. MitraClip reinterventions were performed in 36 patients (57.1%; n=26 SMR, n=10 PMR), while 27 (42.9%; n=13 SMR, n=14 PMR) underwent open heart surgery. Surgical patients with PMR showed lower mortality than patients with SMR (p<0.0001) and ReClip patients with PMR (p=0.073). Atrial fibrillation (HR 2.915, 95% CI: [1.311, 6.480]), prior open heart surgery (2.820 [1.215, 6.544]) and chronic obstructive pulmonary disease (2.506 [1.099, 5.714]) increased the risk of death. The level of post-interventional MR had no relevant impact on survival. CONCLUSIONS: We conclude that, after SMR and failed TMVR, reclipping is an appropriate treatment option for symptomatic patients. For PMR patients, surgery must be favoured over a reclipping procedure. However, patients with atrial fibrillation, prior open heart surgery and chronic obstructive pulmonary disease are at risk of reduced survival after reinterventions.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome
16.
Circulation ; 143(2): 104-116, 2021 01 12.
Article in English | MEDLINE | ID: mdl-32975133

ABSTRACT

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Subject(s)
Heart Valve Diseases/surgery , Heart Valve Prosthesis/standards , Mitral Valve/surgery , Registries , Reoperation/standards , Transcatheter Aortic Valve Replacement/standards , Aged , Aged, 80 and over , Female , Follow-Up Studies , Heart Valve Diseases/diagnostic imaging , Heart Valve Prosthesis/trends , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/trends , Humans , Internationality , Male , Middle Aged , Mitral Valve/diagnostic imaging , Reoperation/trends , Retrospective Studies , Transcatheter Aortic Valve Replacement/trends
17.
Catheter Cardiovasc Interv ; 97(3): 511-515, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32808741

ABSTRACT

BACKGROUND: Presence of thrombus in the left atrial appendage (LAA) remains a severe contraindication to the percutaneous left atrial appendage closure procedure (LAAC), due to increased embolic risk. Recently, the experience developed in cerebral protection device in transcatheter aortic valve implantation (TAVI) procedure was translated in LAAC to address this issue. AIM: To evaluate efficacy and safety of Sentinel cerebral protection system (CPS) in supporting LAAC in real-world patient with persistent LAA thrombus. METHODS AND RESULTS: The study retrospectively enrolled consecutive patients with non-valvular atrial fibrillation (NVAF) and thrombus in LAA who underwent LAAC supported by Sentinel CPS in seven European high-volume centres. Twenty-seven patients were included with a median age of 69.1 ± 9.7 years old, with median CHA2 DS2 -VASc and HAS-BLEED scores 3 [2-5] and 3 [2.75-4], respectively. Technical and procedural success was achieved in all patients. No periprocedural TIA, stroke, or supra-aortic trunks dissection was recorded. CONCLUSIONS: In this multicenter registry, LAAC supported by Sentinel CPS in patients with LAA persistent thrombus seems to be a safe and efficacious treatment.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thrombosis , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/diagnostic imaging , Humans , Retrospective Studies , Stroke/etiology , Stroke/prevention & control , Thrombosis/diagnostic imaging , Thrombosis/etiology , Treatment Outcome
18.
JACC Cardiovasc Interv ; 13(23): 2732-2741, 2020 12 14.
Article in English | MEDLINE | ID: mdl-33189641

ABSTRACT

OBJECTIVES: This study sought to report early experience with the new-generation Watchman FLX device (Boston Scientific, Marlborough, Massachusetts). BACKGROUND: The new-generation Watchman FLX features a reduced height, improved anchoring and fabric coverage, and a closed distal end. These design modifications aim to simplify implantation, allow full recapture and repositioning, and reduce peridevice leak and device-related thrombosis. METHODS: A total of 165 patients undergoing left atrial appendage (LAA) occlusion (LAAO) with Watchman FLX were enrolled in a prospective, multicenter registry at 12 centers participating in the European limited market release program. RESULTS: Mean age was 75.4 ± 8.9 years, and CHA2DS2-VASc score 4.4 ± 1.4. A total of 128 patients (77.6%) had a history of major bleeding, including previous intracranial hemorrhage in 55 cases (33.3%). LAA landing zone minimal and maximal mean diameters were 19.1 ± 3.6 mm and 22.3 ± 3.7 mm, and 24.2% of LAA were considered complex by dimensions. Technical success was achieved in all patients. Successful implantation at first attempt was achieved in 129 cases (78.2%), and a second device was required in 6 cases (3.6%). Procedure-related complications occurred in 3 patients (1.8%): 2 access-related (1.2%) and 1 pericardial effusion (0.6%). No peri-procedural strokes, deaths, or device embolizations occurred. Forty-nine patients (29.7%) were discharged with single antiplatelet therapy, 105 (63.6%) on dual antiplatelet, and 11 (6.7%) on anticoagulation. Imaging follow-up displayed just 1 peridevice leak ≥5 mm and 7 cases of device-related thrombosis (4.7%). During a median follow-up of 55 days (interquartile range: 45 to 148 days), there were 6 hemorrhagic complications (4.8%), 1 patient (0.8%) had an ischemic stroke, and 1 (0.8%) died. No late device embolizations occurred. CONCLUSIONS: LAAO with the Watchman FLX is safe and effective in a wide range of LAA morphologies, with a low procedural complication rate, high degree of LAA sealing, and favorable short-term efficacy.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Aged , Aged, 80 and over , Boston , Cardiac Catheterization , Humans , Prospective Studies , Stroke , Treatment Outcome
19.
Case Rep Cardiol ; 2020: 8217583, 2020.
Article in English | MEDLINE | ID: mdl-32774929

ABSTRACT

Anorexia nervosa is a potentially life-threatening eating disorder, characterized by an abnormally low body weight. This case report illustrates a 22-year old female with cardiac arrest due to a refeeding syndrome in a patient with anorexia nervosa. It features the successful use of extracorporeal cardiopulmonary resuscitation in a case of severe left ventricular dysfunction resulting in a favorable outcome. Conclusion. We present the first case of a cardiac arrest due to a refeeding syndrome in anorexia nervosa featuring the successful use of an extracorporeal cardiopulmonary resuscitation approach as a bridge to full recovery.

20.
Europace ; 22(7): 1036-1043, 2020 07 01.
Article in English | MEDLINE | ID: mdl-32464648

ABSTRACT

AIMS: Evidence regarding post-procedural antithrombotic regimen other than used in randomized trials assessing percutaneous left atrial appendage (LAA) closure is limited. The present work aimed to compare different antithrombotic strategies applied in the real-world EWOLUTION study. METHODS AND RESULTS: A total of 998 patients with successful WATCHMAN implantation were available for the present analysis. The composite ischaemic endpoint of stroke, transitory ischaemic attack, systemic embolism and device thrombus, and the bleeding endpoint defined as at least major bleeding were assessed during an initial period (from implant until first medication change) and long-term period (from first change up to 2 years). The antithrombotic medication chosen in the initial phase was dual antiplatelet therapy (DAPT) in 60%, oral anticoagulation (OAC) in 27%, single antiplatelet therapy (SAPT) in 7%, and no medication in 6%. In the second long-term phase, SAPT was used in 65%, DAPT in 23%, no therapy in 8%, and OAC in 4%. No significant differences were found between the groups regarding the ischaemic endpoint both in the initial period (Kaplan-Meier estimated rate 2.9% for DAPT vs. 4.3% for OAC vs. 3.9% for SAPT or no therapy) and in the second period (4.2% for SAPT vs. 1.8% for DAPT vs. 3.5% for no therapy). With respect to bleeding events, the only difference was found in the initial phase with a higher incidence in patients under SAPT or no therapy. CONCLUSIONS: Tailored antithrombotic treatment using even very reduced strategies such as SAPT or no therapy showed no significant differences regarding ischaemic complications after LAA closure.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Fibrinolytic Agents , Anticoagulants/therapeutic use , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Fibrinolytic Agents/therapeutic use , Humans , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...