Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Publication year range
1.
Andrologia ; 44(5): 355-7, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22385155

ABSTRACT

There has been observed a trend to delay childbearing, reflecting couple's desire to have children at older ages. Maternal age is a well-known factor that influences the achievement of a pregnancy. In contrast, there are few studies examining the effect of paternal age on the outcomes of assisted reproductive technologies (ART), and results are conflicting. Our patient was vasectomised at the age of 60 years, and his wife was 38 years old. A total of four metaphase II oocytes were inseminated 4 h later (day 0) by intracytoplasmic sperm injection using spermatozoa from percutaneous epididymal sperm aspiration. On day 2, the three resulting embryos were transferred (two had four cells, and one had two cells). Two healthy infants were born at the 37th gestational week by caesarean section. Although the effect of paternal age on ART outcomes and results are conflicting, this case report contributes to point out that advanced age of the man has probably lesser negative influence in the reproductive function.


Subject(s)
Azoospermia/therapy , Sperm Retrieval , Adult , Aged, 80 and over , Female , Humans , Male , Pregnancy , Sperm Injections, Intracytoplasmic , Treatment Outcome , Vasectomy
2.
Rev Inst Med Trop Sao Paulo ; 41(2): 115-8, 1999.
Article in English | MEDLINE | ID: mdl-10413959

ABSTRACT

Three GST fusion recombinant antigen of Treponema pallidum, described as GST-rTp47, GST-rTp17 and GST-rTp15 were analyzed by Western blotting techniques. We have tested 53 serum samples: 25 from patients at different clinical stages of syphilis, all of them presenting anti-treponemal antibody, 25 from healthy blood donors and three from patients with sexually transmitted disease (STD) other than syphilis. Almost all samples from patients with syphilis presented a strong reactivity with GST-rTp17 antigen. Some samples were non-reactive or showed a weak reaction with GST-rTp47 and/or GST-rTp15, and apparently there was no correlation with the stage of disease. There was no seropositivity among blood donors. No sample reacted with purified GST. We concluded that due to their specificity these recombinant antigens can be used as GST fusion protein for development of syphilis diagnostic assays.


Subject(s)
Antigens, Bacterial/blood , Recombinant Fusion Proteins , Syphilis/diagnosis , Treponema pallidum/immunology , Blotting, Western , Humans , Sensitivity and Specificity
3.
Article in Portuguese | LILACS | ID: lil-220016

ABSTRACT

Os autores relatam o caso de uma paciente de 57 anos que passou a apresentar bloqueio atrioventricular total (BAVT) em conseqüência de um coice desferido por cavalo (trauma cardíaco fechado). O impacto de coice do animal foi de tal intensidade que arremessou a paciente a vários metros, fraturando-lhe uma costela e provocando o transtorno de conduçäo atrioventricular. Realizado com sucesso o implante de marcapasso provisório, a paciente mostrou boa evoluçäo. O ritmo sinusal com conduçäo AV 1:1 foi restabelecido no dia seguinte ao traumatismo e avaliaçöes posteriores confirmaram o desaparecimento do transtorno.


Subject(s)
Female , Middle Aged , Heart Block , Heart Injuries , Pacemaker, Artificial/classification
4.
Arq Neuropsiquiatr ; 55(1): 8-11, 1997 Mar.
Article in English | MEDLINE | ID: mdl-9332554

ABSTRACT

The detection of IgE is technically difficult because of its reduced concentrations in serum, and even lower concentrations in cerebrospinal fluid (CSF). In the present investigation we studied 86 CSF samples using an immunoenzymatic method with an anti-IgE-alkaline phosphatase conjugate and a fluorigenic substrate. The samples were from three groups: A) 29 patients with neurocysticercosis (NC), B) 36 patients with different neurologic disorders (neurosyphilis, neurotuberculosis, meningitis, tumors, hemorrhage) and C) 21 discharged individuals who had been hospitalized for bacterial meningitis. The results obtained were: A) 0.05 to 3.00 IU/ml (0.76 +/- 0.79), B) 0.00 to 1.50 IU/ml (0.23 +/- 0.34) and C) 0.05 to 1.25 IU/ml (0.34 +/- 0.34). The present results suggest that IgE appears to play a role in the pathogeny of NC and that efforts should be made to standardize a test for the detection of specific IgE antibodies.


Subject(s)
Central Nervous System Diseases/cerebrospinal fluid , Central Nervous System Diseases/parasitology , Cysticercosis/cerebrospinal fluid , Immunoglobulin E/cerebrospinal fluid , Central Nervous System Diseases/immunology , Cysticercosis/immunology , Humans
5.
Article in Portuguese | LILACS | ID: lil-220030

ABSTRACT

Os autores relatam o caso em que uma criança de 48 horas de vida, portadora de bloqueio atrioventricular (BAV) de grau avançado, bradicardia acentuada e insuficiência cardíaca importante foi submetida com sucesso a um implante de marcapasso endocárdico. Como via de acesso foi utilizada a veia jugular interna, o cabo-eletrodo de fixaçäo passiva foi posicionado no ventrículo direito e uma alça foi efetuada no interior do átrio direito. Com o crescimento da criança, observou-se o progressivo desenrolar do cabo-eletrodo. A freqüência inicial do marcapasso com que se obteve melhor débito cardíaco foi de 120 ppm, valor definido através de ecocardiograma bidimensional. Após 28 meses a criança vem apresentando ótima evoluçäo clínica. O marcapasso atualmente demonstra bom funcionamento, tanto no comando como na sensibilidade, e o cabo-eletrodo apresenta desenrolar suave, acompanhando o crescimento da criança.


Subject(s)
Infant, Newborn , Male , Humans , Heart Block/pathology , Bradycardia/diagnosis , Thoracic Surgery/instrumentation , Infant, Newborn , Heart Block/surgery
6.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 9(1): 32-6, jan.-abr. 1996. tab, graf
Article in Portuguese | LILACS | ID: lil-165747

ABSTRACT

Foram observados 106 pacientes portadores de marcapassos de variados modelos e fabricantes para verificar as modificaçöes frente às interferências eletromagnéticas geradas por um telefone celular PT 550 Motorola de circuito analógico. Os pacientes foram examinados sob constante monitorizaçäo eletrocardiográfica e os geradores programados em diferentes modos de comandos e sensibilidades. O telefone celular foi colocado em contato com ambos os ouvidos e sobre a loja do gerador de pulsos. Ocorreram 8 por cento modificaçöes transitórias no funcionamento dos aparelhos, sendo as pausas o fenômeno mais comumente encontrado. Verificou-se que o telefone celular, quando em contato com determinados marcapassos, é capaz de causar mau funcionamento transitório.


Subject(s)
Pacemaker, Artificial , Radiation , Electrocardiography, Ambulatory
8.
Arq. bras. cardiol ; 41(4): 227-230, 1983. ilus
Article in Portuguese | LILACS | ID: lil-16792

ABSTRACT

A partir de janeiro de 1981, os autores idealizaram uma nova tecnica de implante utilizando: 1)eletrodo endocardico com sistema de fixacao em rosca que se prende no ventriculo direito; 2)dispositivo em bolsa de silicone, construido pelos autores, colocado por baixo do gerador e no interior do qual, enrolado, permanece o excesso de eletrodo; 3) ligadura proximal da veia, sobre o eletrodo com "categut" 00 simples, sem nenhuma outra fixacao do eletrodo; 4) gerador multiprogramavel. Com esta tecnica, foram operadas 8 criancas com idades variando de 2 a 11 anos. Quatro pacientes tinham bloqueios congenitos e 4 bloqueios cirurgicos. A anestesia foi local e as criancas foram sedadas, sem entubacao endotraqueal. Em todos os casos, foram conseguidos limiares abaixo de 0,6 V com 0,5 ms de largura de pulso e complexos QRS superiores a 4 mV. Todas as criancas evoluiram bem, sem complicacoes e, apesar do crescimento, nao se observou nenhuma tensao sobre o eletrodo. Conclui-se que a tecnica proposta com o dispositivo em bolsa permite o implante endocardico, com pequeno trauma cirurgico, em criancas de qualquer idade


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Pacemaker, Artificial , Sick Sinus Syndrome , Electrodes , Heart Block
SELECTION OF CITATIONS
SEARCH DETAIL
...