Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Publication year range
1.
Atas saúde ambient. ; 8: 3-15, jan.-dez. 2020. ilus, tab, graf
Article in Portuguese | VETINDEX | ID: vti-25275

ABSTRACT

A presente pesquisa focou o estudo de um sistema de tratamento alternativo de esgoto instalado próximo ao ribeirão Capanema, localizado no município de Itirapuã, estado de São Paulo (Brasil). O sistema de tratamento utilizado é realizado por um conjunto de três lagoas facultativas que tem como intuito minimizar as concentrações de compostos contaminantes presentes no rejeito liquido do Capanema, entre eles o fósforo (P) oriundo da atividade agrícola na região. O processo de depuração dos rejeitos da água ocorre a partir da ação anaeróbica e aeróbica caracterizada pelo processo anóxico e por aeração, além da reação ultravioleta da radiação solar ocorrida no interior do conjunto de lagoas facultativas. As mesmas são formadas por uma lagoa inicial denominada anaeróbica de volume 5.580 m3, sendo seguida por uma lagoa primária de3.830 m3 e uma secundária de 4.960 m3. Somente após a água derivada do rio Capanema passar pelo conjunto de lagoa facultativa é que o efluente tratado volta ao curso normal do ribeirão já com uma qualidade melhor das águas. A qualidade é verificada pelo aumento da concentração de oxigênio dissolvido(OD) nas águas em torno de 70%. Na pesquisa foi monitorado coletas de amostras de entrada e saída do sistema de lagoas durante três meses no ano de 2018, onde as amostras acondicionadas em garrafas PET de 500 ml foram congeladas à -5oC para posterior preparo em laboratório para analise de presença de fósforo total pelo método oficial 973.55 da AOAC. Após o preparo das amostras e analise pelo processo de espectrofotométria das amostras de entrada e saída o valor percentual médio de remoção de fósforo total das águas ficou em 22,58%, com concentração de fósforo em torno de 10,76 mg.L-1. Tal diminuição gera uma menor carga difusa que promove uma melhor preservação do corpo hídrico, uma vez que impacta menos a via aquática do ribeirão Capanema. Haja vista que por tal ...(AU)


This research focused on the study of an alternative sewage treatment system installed near the Capanema stream, located in the municipality of Itirapuã, state of São Paulo (Brazil). The treatment system used is performed by a set of three optional lagoons that aims to minimize the concentrations of contaminating compounds present in Capanema liquid tailings, among them the phosphorus (P) from the agricultural activity in the region. The purification process of water tailings occurs from the anaerobic and aerobic action characterized by the anoxic and aeration process, as well as the ultraviolet reaction of solar radiation that occurred inside the facultative ponds. They are formed by an initial anaerobic lagoon of 5,580 m3 volume, followed by a primary lagoon of 3,830 m3 and a secondary lagoon of 4,960 m3. Only after the water derived from the Capanema River passes through the facultative lagoon pool does the treated effluent return to the normal course of the stream with betterwater quality. The quality is verified by the increase of dissolved oxygen (DO) concentration in the waters around 70%. In the research, samples were collected from inlets and outlets of the lagoon system during three months in2018, where the samples packed in 500 ml PET bottles were frozen at -5oC for subsequent preparation in laboratory for total phosphorus presence analysis AOAC official method 973.55. After sample preparation and analysis by the spectrophotometric process of the inlet and outlet samples the mean percentage value of total phosphorus removal from the waters was 22.58%, with phosphorus concentration around 10.76 mg.L-1. This decrease generates a less diffuse charge that promotes better preservation of the water body, since it impacts less the waterway of the Capanema stream. Considering that by this process the creek itself has an improvement in its classification of water body...(AU)


Subject(s)
Water Purification/methods , Sewage , Phosphorus/administration & dosage , Basic Sanitation
2.
Atas saúde ambient. ; 8: 45-61, jan.-dez. 2020. ilus, tab, graf
Article in Portuguese | VETINDEX | ID: vti-25260

ABSTRACT

A proteção e o uso adequado das fontes de água potável no planeta devem ser buscadas de forma exaustiva para a conservação da vida na terra. O processo de industrialização e crescimento demográfico acaba por tornar ainda mais preocupante a manutenção das reservas hídricas para garantir o desenvolvimento sustentável. Frente a esse desafio, cada vez mais os ramos da engenharia ligados à área ambiental vêm desenvolvendo novos métodos de tratamento do esgoto de forma a alcançar a manutenção da água para as futuras gerações. Entre as novas tecnologias em estudo tem-se o sistema de filtração lenta que a partir da utilização de reservatórios com camadas de areia e pedra de tamanhos distintos possibilitam por processos físico-químicos a depuração do esgoto. A presente pesquisa buscou monitorar e avaliar a concentração de oxigênio dissolvido em um sistema de filtros lentos com e sem carvão ativado projetado e instalado na UNICAMP. Durante as nove semanas de estudo os resultados alcançados foram de eficiência no ganho de oxigênio dissolvido no filtro com e sem carvão ativo de 90,67% e 49,50%, respectivamente.(AU)


The protection and proper use of drinking water sources on the planet should be pursued in an exhaustive way for the conservation of life on earth. The process of industrialization and population growth have made the maintenance of water reserves even more worrisome to ensure sustainable development. Faced with this challenge, more and more the engineering branches related to the environmental area have been developing new methods of treatment of the sewage in order to reach the maintenance of water for future generations. Among the new technologies under study is the slow filtration system which, through theuse of reservoirs with layers of sand and stone of different sizes, enables the purification of sewage by physico-chemical processes. The present research sought to monitor and evaluate the concentration of dissolved oxygen in a systemof slow filters with and without activated carbon designed and installed in UNICAMP. During the nine weeks of study, the results obtained were of efficiency in the gain of oxygen dissolved in the filter with and without active carbon of 90.67% and 49.50%, respectively.(AU)


Subject(s)
Sand Filters , Slow Filtration , Activated Carbon (Environmental Health) , Domestic Effluents , Oxygen Level
3.
Atas Saúde Ambient ; 8: 3-15, jan.-dez. 2020. ilus, tab, graf
Article in Portuguese | VETINDEX | ID: biblio-1463799

ABSTRACT

A presente pesquisa focou o estudo de um sistema de tratamento alternativo de esgoto instalado próximo ao ribeirão Capanema, localizado no município de Itirapuã, estado de São Paulo (Brasil). O sistema de tratamento utilizado é realizado por um conjunto de três lagoas facultativas que tem como intuito minimizar as concentrações de compostos contaminantes presentes no rejeito liquido do Capanema, entre eles o fósforo (P) oriundo da atividade agrícola na região. O processo de depuração dos rejeitos da água ocorre a partir da ação anaeróbica e aeróbica caracterizada pelo processo anóxico e por aeração, além da reação ultravioleta da radiação solar ocorrida no interior do conjunto de lagoas facultativas. As mesmas são formadas por uma lagoa inicial denominada anaeróbica de volume 5.580 m3, sendo seguida por uma lagoa primária de3.830 m3 e uma secundária de 4.960 m3. Somente após a água derivada do rio Capanema passar pelo conjunto de lagoa facultativa é que o efluente tratado volta ao curso normal do ribeirão já com uma qualidade melhor das águas. A qualidade é verificada pelo aumento da concentração de oxigênio dissolvido(OD) nas águas em torno de 70%. Na pesquisa foi monitorado coletas de amostras de entrada e saída do sistema de lagoas durante três meses no ano de 2018, onde as amostras acondicionadas em garrafas PET de 500 ml foram congeladas à -5oC para posterior preparo em laboratório para analise de presença de fósforo total pelo método oficial 973.55 da AOAC. Após o preparo das amostras e analise pelo processo de espectrofotométria das amostras de entrada e saída o valor percentual médio de remoção de fósforo total das águas ficou em 22,58%, com concentração de fósforo em torno de 10,76 mg.L-1. Tal diminuição gera uma menor carga difusa que promove uma melhor preservação do corpo hídrico, uma vez que impacta menos a via aquática do ribeirão Capanema. Haja vista que por tal ...


This research focused on the study of an alternative sewage treatment system installed near the Capanema stream, located in the municipality of Itirapuã, state of São Paulo (Brazil). The treatment system used is performed by a set of three optional lagoons that aims to minimize the concentrations of contaminating compounds present in Capanema liquid tailings, among them the phosphorus (P) from the agricultural activity in the region. The purification process of water tailings occurs from the anaerobic and aerobic action characterized by the anoxic and aeration process, as well as the ultraviolet reaction of solar radiation that occurred inside the facultative ponds. They are formed by an initial anaerobic lagoon of 5,580 m3 volume, followed by a primary lagoon of 3,830 m3 and a secondary lagoon of 4,960 m3. Only after the water derived from the Capanema River passes through the facultative lagoon pool does the treated effluent return to the normal course of the stream with betterwater quality. The quality is verified by the increase of dissolved oxygen (DO) concentration in the waters around 70%. In the research, samples were collected from inlets and outlets of the lagoon system during three months in2018, where the samples packed in 500 ml PET bottles were frozen at -5oC for subsequent preparation in laboratory for total phosphorus presence analysis AOAC official method 973.55. After sample preparation and analysis by the spectrophotometric process of the inlet and outlet samples the mean percentage value of total phosphorus removal from the waters was 22.58%, with phosphorus concentration around 10.76 mg.L-1. This decrease generates a less diffuse charge that promotes better preservation of the water body, since it impacts less the waterway of the Capanema stream. Considering that by this process the creek itself has an improvement in its classification of water body...


Subject(s)
Sewage , Phosphorus/administration & dosage , Water Purification/methods , Basic Sanitation
4.
Atas Saúde Ambient ; 8: 45-61, jan.-dez. 2020. ilus, tab, graf
Article in Portuguese | VETINDEX | ID: biblio-1463801

ABSTRACT

A proteção e o uso adequado das fontes de água potável no planeta devem ser buscadas de forma exaustiva para a conservação da vida na terra. O processo de industrialização e crescimento demográfico acaba por tornar ainda mais preocupante a manutenção das reservas hídricas para garantir o desenvolvimento sustentável. Frente a esse desafio, cada vez mais os ramos da engenharia ligados à área ambiental vêm desenvolvendo novos métodos de tratamento do esgoto de forma a alcançar a manutenção da água para as futuras gerações. Entre as novas tecnologias em estudo tem-se o sistema de filtração lenta que a partir da utilização de reservatórios com camadas de areia e pedra de tamanhos distintos possibilitam por processos físico-químicos a depuração do esgoto. A presente pesquisa buscou monitorar e avaliar a concentração de oxigênio dissolvido em um sistema de filtros lentos com e sem carvão ativado projetado e instalado na UNICAMP. Durante as nove semanas de estudo os resultados alcançados foram de eficiência no ganho de oxigênio dissolvido no filtro com e sem carvão ativo de 90,67% e 49,50%, respectivamente.


The protection and proper use of drinking water sources on the planet should be pursued in an exhaustive way for the conservation of life on earth. The process of industrialization and population growth have made the maintenance of water reserves even more worrisome to ensure sustainable development. Faced with this challenge, more and more the engineering branches related to the environmental area have been developing new methods of treatment of the sewage in order to reach the maintenance of water for future generations. Among the new technologies under study is the slow filtration system which, through theuse of reservoirs with layers of sand and stone of different sizes, enables the purification of sewage by physico-chemical processes. The present research sought to monitor and evaluate the concentration of dissolved oxygen in a systemof slow filters with and without activated carbon designed and installed in UNICAMP. During the nine weeks of study, the results obtained were of efficiency in the gain of oxygen dissolved in the filter with and without active carbon of 90.67% and 49.50%, respectively.


Subject(s)
Activated Carbon (Environmental Health) , Domestic Effluents , Slow Filtration , Sand Filters , Oxygen Level
5.
Atas saúde ambient. ; 7: 217-238, jan.-dez. 2019. ilus, tab, graf
Article in Portuguese | VETINDEX | ID: vti-24621

ABSTRACT

A escassez de água no planeta faz com que seja cada vez mais necessária aconscientização da sociedade e a formulação de políticas públicas que permitama conservação das fontes nobres de água potável para abastecimento público.O processo de reuso de águas pré-tratadas em atividades industriais, porexemplo, tornam-se uma ferramenta interessante para utilização. Tais sistemasde reuso podem ser obtidos a partir de tratamentos alternativos de esgotodoméstico. Um dos sistemas que vem sendo cada vez mais divulgados no meioacadêmico e cientifico são as wetlands. Sistemas de tratamento que utilizammeio suporte e plantas adaptadas para remoção dos compostos patógenospresentes no esgoto. A pesquisa desenvolvida utilizou um sistema de wetlandsem perfil quadrado e retangular instalada na UNICAMP. O estudo durou novesemanas e possibilitou que se avaliasse o desempenho na remoção de coliformesfecais. Para a wetlands de perfil quadrado o desempenho foi de 35,49%,enquanto que para o sistema de perfil retangular o valor percentual foi de31,67%.(AU)


The scarcity of water on the planet makes it increasingly necessary to raiseawareness of society and to formulate public policies that allow the conservationof noble sources of drinking water for public supply. The process of reuse of pretreated water industrial activities, for example, become an interesting tool foruse. Such reuse systems can be obtained from alternative treatments ofdomestic sewage. One of the systems that are being increasingly disclosed inacademic and scientific environments are wetlands. Treatment systems that usesupport medium and adapted plants to remove the pathogenic compoundspresent in the sewage. The research developed used a square and rectangularprofile wetlands system installed in UNICAMP. The study lasted nine weeks andallowed the evaluation of fecal coliform removal performance. For the squareprofile wetlands the performance was 35.49%, while for the rectangular profilesystem the percentage value was 31.67%.(AU)


Subject(s)
Wetlands, Constructed , Biological Filters/analysis , Biological Filters/methods , Coliforms/analysis , Water Purification/methods
6.
Atas Saúde Ambient ; 7: 217-238, jan.-dez. 2019. ilus, tab, graf
Article in Portuguese | VETINDEX | ID: biblio-1463790

ABSTRACT

A escassez de água no planeta faz com que seja cada vez mais necessária aconscientização da sociedade e a formulação de políticas públicas que permitama conservação das fontes nobres de água potável para abastecimento público.O processo de reuso de águas pré-tratadas em atividades industriais, porexemplo, tornam-se uma ferramenta interessante para utilização. Tais sistemasde reuso podem ser obtidos a partir de tratamentos alternativos de esgotodoméstico. Um dos sistemas que vem sendo cada vez mais divulgados no meioacadêmico e cientifico são as wetlands. Sistemas de tratamento que utilizammeio suporte e plantas adaptadas para remoção dos compostos patógenospresentes no esgoto. A pesquisa desenvolvida utilizou um sistema de wetlandsem perfil quadrado e retangular instalada na UNICAMP. O estudo durou novesemanas e possibilitou que se avaliasse o desempenho na remoção de coliformesfecais. Para a wetlands de perfil quadrado o desempenho foi de 35,49%,enquanto que para o sistema de perfil retangular o valor percentual foi de31,67%.


The scarcity of water on the planet makes it increasingly necessary to raiseawareness of society and to formulate public policies that allow the conservationof noble sources of drinking water for public supply. The process of reuse of pretreated water industrial activities, for example, become an interesting tool foruse. Such reuse systems can be obtained from alternative treatments ofdomestic sewage. One of the systems that are being increasingly disclosed inacademic and scientific environments are wetlands. Treatment systems that usesupport medium and adapted plants to remove the pathogenic compoundspresent in the sewage. The research developed used a square and rectangularprofile wetlands system installed in UNICAMP. The study lasted nine weeks andallowed the evaluation of fecal coliform removal performance. For the squareprofile wetlands the performance was 35.49%, while for the rectangular profilesystem the percentage value was 31.67%.


Subject(s)
Coliforms/analysis , Biological Filters/analysis , Biological Filters/methods , Water Purification/methods , Wetlands, Constructed
SELECTION OF CITATIONS
SEARCH DETAIL