Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Chem Lab Med ; 50(3): 489-95, 2011 Nov 23.
Article in English | MEDLINE | ID: mdl-22098433

ABSTRACT

BACKGROUND: New monoclonal antibody-based assays for serum-free light chains (FLC) have become available. METHODS: In a clinical study with 541 patients, the new N Latex FLC assays were compared with the Freelite FLC assays and immunofixation electrophoresis (IF). RESULTS: Comparison of the different FLC kappa (κ) assays showed a slope of 0.99 with a deviation of 5.0%, rs=0.92, for FLC lambda (λ) a slope of 1.22, deviation 13.8%, rs=0.90 and for the κ/λ ratio a slope of 0.72, deviation -4.6%, rs=0.72. The concordance for the FLC κ assays was 91%, for FLC λ 85% and κ/λ ratio 95%. The clinical sensitivity and specificity of the κ/λ ratios in the study were comparable: 60% and 99% for the N Latex FLC assay and 61% and 97% for the Freelite assay. In IF-FLC positive samples, the N Latex FLC κ/λ ratio scored 20/23 (87%) samples outside the reference range and Freelite 21/23 (91%). For IF-FLC negative samples, N Latex FLC assay κ/λ ratio scored 338/350 (97%) within the reference range and Freelite scored 332/350 (95%). CONCLUSIONS: The concordance scores and the clinical sensitivity and specificity of the new N Latex FLC assays and Freelite assays appeared comparable, but there are some differences in measurement of concentrations between the methods.


Subject(s)
Antibodies, Monoclonal/immunology , Electrophoresis , Immunoglobulin kappa-Chains/blood , Immunoglobulin lambda-Chains/blood , Nephelometry and Turbidimetry/methods , Serologic Tests/methods , Hospitals , Humans , Immunoglobulin kappa-Chains/immunology , Immunoglobulin kappa-Chains/isolation & purification , Immunoglobulin lambda-Chains/immunology , Immunoglobulin lambda-Chains/isolation & purification , Paraproteinemias/blood , Sensitivity and Specificity
2.
Clin Chem Lab Med ; 49(8): 1323-1332, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21663464

ABSTRACT

BACKGROUND: High serum concentrations of monoclonal free light chain (FLC) kappa or lambda are markers of plasma cell dyscrasia. METHODS: We developed new, latex-enhanced, specific nephelometric assays based on monoclonal antibodies for the determination of FLC kappa and lambda in serum, EDTA plasma and Li-heparin plasma for use on the Siemens BN™ systems. RESULTS: Reference ranges were determined from 369 samples: FLC kappa 6.7-22.4 mg/L, FLC lambda 8.3-27.0 mg/L and kappa/lambda ratio 0.31-1.56. Protection from falsely low results due to antigen excess is obtained with a built-in pre-reaction in the assay protocols. Lot-to-lot consistency between three different lots of reagent, calibrators and supplementary reagent lots showed normalized differences <7.5%. The reproducibility of serum samples varied between 4% and 7%. The method comparison with Freelite™ assays showed normalized differences of 19.7%, 32.7% and 21.7%, respectively, for FLC kappa, lambda and ratio, correlations of 0.94, 0.77 and 0.73, and concordance rates of 99.2%, 94.2% and 95%. CONCLUSIONS: N Latex FLC demonstrates high precision, good lot-to-lot consistency and freedom from a high-dose hook effect. The method comparison between Freelite™ and the N Latex FLC assays showed good clinical concordance. Further studies need to reveal the clinical value of the new FLC assays.


Subject(s)
Antibodies, Monoclonal/immunology , Nephelometry and Turbidimetry/methods , Humans , Immunoassay/methods , Immunoglobulin kappa-Chains/blood , Immunoglobulin lambda-Chains/blood , Paraproteinemias/diagnosis , Reagent Kits, Diagnostic , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...