1.
J Biomed Mater Res B Appl Biomater ; 105(5): 1126-1130, 2017 07.
Article in English | MEDLINE | ID: mdl-27015658

ABSTRACT

Reliability of wound closure is limited primarily by the capacity of tissues to support conventional sutures (or staples), not by strength of either material per se. We developed FiberSecure™ for closures to surpass tissue strength. We assessed and compared the mechanical and histological performance of FiberSecure™ suture versus commercially available braided polyester suture (Mersilene) in the closure of abdominal muscle incisions in miniature swine at approximately 3 months postsurgery. Four incisions were closed in the external oblique muscle of eight Sinclair minipigs. Two wounds were closed with FiberSecure™ suture size 0 and the remaining two with Mersilene suture size 0. At 90 days, specimens were removed for biomechanics and histology. In destructive tensile testing, in the 16 abdominal muscle specimens for the FiberSecure™ suture, muscle tear was not near the suture implantation region, which remained intact. Wound strength met or exceeded strength of neighboring tissue in FiberSecure™ groups, which had peak force of 55.7 ± 22.1 N (mean ± SD) and peak stress of 579.0 ± 159.2 KPa (mean ± SD). For Mersilene, 3 of the 16 samples tore at the suture site and the remaining samples tore through the abdominal muscle not near the implantation region. The wound strength was similar to surrounding tissue, and these specimens had peak force of 51.8 ± 21.7 N and peak stress of 550.3 ± 239.4 KPa (mean ± SD). No significant difference was observed in peak force or stress between groups (p > 0.05), most repairs having met or exceeded native tissue strength by this time point. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1126-1130, 2017.


Subject(s)
Materials Testing , Polyesters , Sutures , Wound Closure Techniques , Animals , Swine , Swine, Miniature
2.
J Orthop Res ; 30(7): 1112-7, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22179930

ABSTRACT

Whenever a tendon or its bone insertion is disrupted or removed, existing surgical techniques provide a temporary connection or scaffolding to promote healing, but the interface of living to non-living materials soon breaks down under the stress of these applications, if it must bear the load more than acutely. Patients are thus disabled whose prostheses, defect size, or mere anatomy limit the availability or outcomes of such treatments. Our group developed the OrthoCoupler™ device to join skeletal muscle to prosthetic or natural structures without this interface breakdown. In this study, the goat knee extensor mechanism (quadriceps tendon, patella, and patellar tendon) was removed from the right hind limb in 16 goats. The device connected the quadriceps muscle to a stainless steel bone plate on the tibia. Mechanical testing and histology specimens were collected from each operated leg and contralateral unoperated control legs at 180 days. Maximum forces in the operated leg (vs. unoperated) were 1,400 ± 93 N (vs. 1,179 ± 61 N), linear stiffnesses were 33 ± 3 N/mm (vs. 37 ± 4 N/mm), and elongations at failure were 92.1 ± 5.3 mm (vs. 68.4 ± 3.8 mm; mean ± SEM). Higher maximum forces (p = 0.02) and elongations at failure (p=0.008) of legs with the device versus unoperated controls were significant; linear stiffnesses were not (p=0.3). We believe this technology will yield improved procedures for clinical challenges in orthopedic oncology, revision arthroplasty, tendon transfer, and tendon injury reconstruction.


Subject(s)
Artificial Organs/standards , Orthopedic Procedures/methods , Quadriceps Muscle/surgery , Tendons/surgery , Tibia/surgery , Wound Healing/physiology , Animals , Biomechanical Phenomena/physiology , Goats , Limb Salvage/methods , Male , Materials Testing , Prosthesis Implantation/methods , Prosthesis Implantation/standards , Reproducibility of Results , Tendons/physiology , Weight-Bearing/physiology
3.
J Orthop Res ; 29(11): 1775-82, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21520259

ABSTRACT

No permanent, reliable artificial tendon exists clinically. Our group developed the OrthoCoupler™ device as a versatile connector, fixed at one end to a muscle, and adaptable at the other end to inert implants such as prosthetic bones or to bone anchors. The objective of this study was to evaluate four configurations of the device to replace the extensor mechanism of the knee in goats. Within muscle, the four groups had: (A) needle-drawn uncoated bundles, (B) needle-drawn coated bundles, (C) barbed uncoated bundles, and (D) barbed coated bundles. The quadriceps tendon, patella, and patellar tendon were removed from the right hind limb in 24 goats. The four groups (n = 6 for each) were randomly assigned to connect the quadriceps muscle to the tibia (with a bone plate). Specimens were collected from each operated leg and contralateral unoperated controls both for mechanical testing and histology at 90 days post-surgery. In strength testing, maximum forces in the operated leg (vs. unoperated control) were 1,288 ± 123 N (vs. 1,387 ± 118 N) for group A, 1,323 ± 144 N (vs. 1,396 ± 779 N) for group B, 930 ± 125 N (vs. 1,337 ± 126 N) for group C, and 968 ± 109 N (vs. 1,528 ± 146 N) for group D (mean ± SEM). The strengths of the OrthoCoupler™ legs in the needled device groups were equivalent to unoperated controls (p = 0.6), while both barbed device groups had maximum forces significantly lower than their controls (p = 0.001). We believe this technology will yield improved procedures for clinical challenges in orthopaedic oncology, revision arthroplasty, tendon transfer, and tendon injury reconstruction.


Subject(s)
Artificial Organs , Limb Salvage/methods , Prosthesis Design , Quadriceps Muscle/surgery , Tendons , Tibia/surgery , Animals , Biomechanical Phenomena/physiology , Coated Materials, Biocompatible , Equipment Failure Analysis , Goats , Limb Salvage/instrumentation , Male , Models, Animal , Motor Activity/physiology , Orthopedic Procedures/instrumentation , Orthopedic Procedures/methods , Osseointegration , Quadriceps Muscle/physiology , Stress, Mechanical , Tibia/physiology
4.
J Biomed Mater Res B Appl Biomater ; 97(1): 184-9, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21328693

ABSTRACT

Wounds often cannot be successfully closed by conventional means of closure such as sutures or staples. Our group developed the FiberSecure™ device to close soft tissue wounds reliably, surpassing native tissue strength. We closed cross-fiber muscle incisions, to evaluate (1) four different configurations of FiberSecure™ for 30 days, then (2) the resulting preferred configuration for 180 days. The four treatment groups each placed 21,504 polyester (PET) 12-µm fibers (cross-sectional area 1% of muscle) traversing the incision, in the form of (A) Four large (No.7 suture) non-textured bundles, (B) Eight small (No.2 suture) non-textured, (C) Four large textured, or (D) Eight small textured. Four incisions were closed in the external oblique muscle of 16 Sinclair minipigs. At 30 days, specimens were removed for biomechanics, histology, and total collagen content. Group (B) was selected for 180-day evaluations in the same wound model in eight animals, four closures each (n = 32), again with biomechanics and histology. In strength testing, every specimen tore through muscle remotely, while the repair region remained intact. Maximum forces were (A) 37.8 ± 3.9 N, (B) 37.1 ± 4.7 N, (C) 39.0 ± 5.3 N, and (D) 32.4 ± 3.4 N at 30 days, and 37.2 ± 11.3 N at 180 days (mean ± SEM). No significant difference was observed among the groups or time points (p > 0.05).


Subject(s)
Bandages , Materials Testing/methods , Muscle, Skeletal/injuries , Wounds, Penetrating/therapy , Animals , Female , Muscle, Skeletal/pathology , Swine , Swine, Miniature , Time Factors , Wounds, Penetrating/pathology
5.
J Orthop Res ; 28(2): 218-24, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19639642

ABSTRACT

A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler device to satisfy these demands. The objective of this study was to test OrthoCoupler's performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n = 4 each. For in vivo evaluation, the semitendinosus tendon was removed bilaterally in eight goats. Left sides were reattached with an OrthoCoupler, and right sides were reattached using the Krackow stitch with #5 braided polyester sutures. Specimens were harvested 60 days postsurgery and assigned for biomechanics and histology. Fatigue strength of the devices in vitro was several times the contractile force of the semitendinosus muscle. The in vivo devices were built equivalent to two of the in vitro devices, providing an additional safety factor. In strength testing at necropsy, suture controls pulled out at 120.5 +/- 68.3 N, whereas each OrthoCoupler was still holding after the muscle tore, remotely, at 298 +/- 111.3 N (mean +/- SD) (p < 0.0003). Muscle tear strength was reached with the fiber-muscle composite produced in healing still soundly intact. This technology may be of value for orthopaedic challenges in oncology, revision arthroplasty, tendon transfer, and sports-injury reconstruction.


Subject(s)
Materials Testing , Orthopedic Procedures/instrumentation , Plastic Surgery Procedures/instrumentation , Prosthesis Design , Prosthesis Implantation/instrumentation , Tendon Injuries/surgery , Animals , Biocompatible Materials , Biomechanical Phenomena , Disease Models, Animal , Equipment Failure Analysis , Muscle, Skeletal/pathology , Muscle, Skeletal/surgery , Prosthesis Implantation/methods , Plastic Surgery Procedures/methods , Stress, Mechanical , Tendon Injuries/pathology , Tendons/pathology , Tendons/surgery