Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Publication year range
1.
J Matern Fetal Neonatal Med ; 35(25): 9078-9085, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35099350

ABSTRACT

OBJECTIVES: To calculate the accuracy (A) and establish the best cutoff value for ophthalmic artery (OA) Doppler velocimetry indexes in patients diagnosed with preeclampsia (PE), compared with healthy pregnant women. METHODS: This prospective experimental study enrolled 268 women: 133 with PE and 135 healthy pregnant women. All patients were evaluated by OA Doppler sonography, bilaterally, to assess their pulsatility index (PI), resistance index (RI), peak systolic velocity (PVS), second peak systolic velocity (P2), end-diastolic velocity (EDV), and peak ratio (PR). Means were compared using Student's T-test. Receiver Operating Characteristics (ROC) curve was used to establish the cutoff value and estimate the sensitivity (S), specificity (Sp), accuracy (A) of all variables, and a significance of 95% was adopted. RESULTS: ROC curve analysis showed that P2 and PR were superior to the other parameters for PE diagnosis. We tested two cutoff values: (1) using PR ≥0.70, obtained A: 88.72%, S: 81.95%, and Sp: 95.48% and (2) using PR ≥0.75, and A: 86.24%, S: 74.43%, and Sp: 99.24%. By adopting P2 ≥ 21.5 cm/s, we obtained A: 87.59%, S: 84.96%, and Sp: 90.22% and when the cutoff point was P2 ≥ 22 cm/s, there was a slight decrease in A to 86.46% and S to 81.20%, with Sp: 91.89.3%. CONCLUSION: Ophthalmic artery Doppler demonstrated to be an effective and high-performance imaging method for the diagnosis of PE and the indexes P2 and PR demonstrated superior accuracy to the other Doppler parameters assessed. Higher performance occurred when the cutoff values with greater specificity were adopted, PR ≥ 0.75 and P2 ≥ 22 cm/s, considering that the proposed OA Doppler is to be a complementary method for preeclampsia.


Subject(s)
Ophthalmic Artery , Pre-Eclampsia , Female , Humans , Pregnancy , Ophthalmic Artery/diagnostic imaging , Pre-Eclampsia/diagnostic imaging , Prospective Studies , Ultrasonography, Doppler/methods , Rheology/methods , Blood Flow Velocity
2.
Open educational resource in Portuguese | CVSP - Brazil | ID: una-6009

ABSTRACT

A Estratégia Saúde da Família (ESF) Santa Rita, localizada no município de Cássia, Minas Gerais, abrange uma população de aproximadamente 3.500 pessoas. A sede da equipe, apesar de não possuir prédio próprio, possui uma estrutura capaz de atender satisfatoriamente todos os pacientes. Dentre esses, os portadores de Hipertensão Arterial Sistêmica cadastrados correspondem a 22,8% da população adulta e tendo sido identificado que grande parte deles não aderiam ao tratamento conforme a prescrição médica culminando no surgimento de complicações consequentes da doença. Percebeu-se que a não adesão estava relacionada ao desconhecimento em relação ao agravo, bem como à dificuldade em compreender o que era proposto para o seu controle. Diante a importância da doença e a morbidade e mortalidade elevadas que o seu mau controle poderiam levar foi proposto um projeto de intervenção cujo objetivo é levar à população conhecimento sobre a doença e suas nuances por meio de palestras na unidade e em escolas da rede pública e de grupos de Hiperdia a fim de se obter um controle melhor da Hipertensão Arterial.


Subject(s)
Hypertension , Family Health , Health Education
SELECTION OF CITATIONS
SEARCH DETAIL
...