Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters










Publication year range
1.
J Cardiovasc Electrophysiol ; 34(3): 682-692, 2023 03.
Article in English | MEDLINE | ID: mdl-36482158

ABSTRACT

INTRODUCTION: Reliable ex vivo cardiac ablation models have the potential to increase catheter testing throughput while minimizing animal usage. The goal of this work was to develop a physiologically relevant ex vivo swine model of cardiac ablation displaying minimal variability and high repeatability and identify and optimize key parameters involved in ablation outcomes. METHODS AND RESULTS: A root cause analysis was conducted to identify variables affecting ablation outcomes. Parameters associated with the tissue, bath media, and impedance were identified. Variables were defined experimentally and/or from literature sources to best mimic the clinical cardiac ablation setting. The model was validated by performing three independent replicates of ex vivo myocardial ablation and a direct comparison of lesion outcomes of the ex vivo swine myocardial and in vivo canine thigh preparation (TP) models. Replicate experiments on the ex vivo model demonstrated low variance in ablation depth (6.5 ± 0.6, 6.3 ± 0.6, 6.2 ± 0.4 mm) and width (10.4 ± 1.1, 9.7 ± 1.0, 9.9 ± 0.9 mm) and no significant differences between replicates. In a direct comparison of the two models, the ex vivo model demonstrated ablation depths similar to the canine TP model at 35 W (6.9 ± 1.0, and 7.0 ± 0.9 mm) and 50 W (8.0 ± 0.7, and 8.4 ± 0.7 mm), as well as similar power to depth ratios (15% and 19% for the ex vivo cardiac and in vivo TP models, respectively). CONCLUSION: The ex vivo model exhibited strong lesion reproducibility and power-to-depth ratios comparable to the in vivo TP model. The optimized ex vivo model minimizes animal usage with increased throughput, lesion characteristics similar to the in vivo TP model, and ability to discriminate minor variations between different catheter designs.


Subject(s)
Catheter Ablation , Heart , Swine , Animals , Dogs , Reproducibility of Results , Myocardium/pathology , Catheter Ablation/methods , Catheters , Cardiac Catheters
2.
Arthroplast Today ; 12: 1-6, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34703862

ABSTRACT

BACKGROUND: Barbed suture has become popular for closure of the arthrotomy and overlying tissues in total knee arthroplasty. STRATAFIX Symmetric PDS Knotless Tissue Control Device, a unique and novel barbed suture, with barbs formed integral to the suture core provides greater suture strength than the more common cut barbed suture designs. It is the only barbed suture commercially available with an indication in high tension areas, such as fascia. The purpose of this study was to evaluate the use of this novel barbed suture in the formation of a water-tight arthrotomy closure, using a continuous suture pattern, compared to conventional Coated VICRYL (polyglactin 910) Suture, using an interrupted suture pattern, in a cadaveric knee arthrotomy. METHODS: Twenty fresh-frozen cadaver knees underwent randomization to provide donor-paired matching of the knee arthrotomy closures using barbed suture in a continuous pattern or conventional suture in an interrupted pattern. Each specimen underwent 5 phases of testing that included 1) predynamic static leak testing; 2) dynamic motion leak testing; 3) postdynamic static leak testing; 4) suture release static leak testing; and 5) postsuture release dynamic motion leak testing, to assess the fluid leak rate. RESULTS: Under the initial static conditions, watertightness was similar for the 2 types of sutures. However, in all subsequent phases of testing, continuous barbed suture created a better watertight closure than interrupted conventional suture. CONCLUSIONS: In this study, it was observed that closure of a knee arthrotomy using the novel barbed suture provided improved watertightness compared to conventional interrupted closure under dynamic conditions and suture release.

3.
Cell Rep Med ; 1(5): 100062, 2020 08 25.
Article in English | MEDLINE | ID: mdl-32838340

ABSTRACT

There is an urgent need for rapid SARS-CoV-2 testing in hospitals to limit nosocomial spread. We report an evaluation of point of care (POC) nucleic acid amplification testing (NAAT) in 149 participants with parallel combined nasal and throat swabbing for POC versus standard lab RT-PCR testing. Median time to result is 2.6 (IQR 2.3-4.8) versus 26.4 h (IQR 21.4-31.4, p < 0.001), with 32 (21.5%) positive and 117 (78.5%) negative. Cohen's κ correlation between tests is 0.96 (95% CI 0.91-1.00). When comparing nearly 1,000 tests pre- and post-implementation, the median time to definitive bed placement from admission is 23.4 (8.6-41.9) versus 17.1 h (9.0-28.8), p = 0.02. Mean length of stay on COVID-19 "holding" wards is 58.5 versus 29.9 h (p < 0.001). POC testing increases isolation room availability, avoids bed closures, allows discharge to care homes, and expedites access to hospital procedures. POC testing could mitigate the impact of COVID-19 on hospital systems.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19/diagnosis , Infection Control/methods , Point-of-Care Testing , SARS-CoV-2/isolation & purification , Adult , Aged , COVID-19 Nucleic Acid Testing/standards , Cross Infection/prevention & control , Female , Hospitalization , Humans , Male , Middle Aged , Point-of-Care Testing/standards , SARS-CoV-2/genetics
4.
Rapid Commun Mass Spectrom ; 28(22): 2471-9, 2014 Nov 30.
Article in English | MEDLINE | ID: mdl-25303476

ABSTRACT

RATIONALE: The ability to quantify rates of formation, regression and/or remodeling of atherosclerotic plaque should facilitate a better understanding of the pathogenesis and management of cardiovascular disease. In the current study, we coupled a stable isotope labeled tracer protocol with matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) to examine spatial and temporal lipid dynamics in atherosclerotic plaque. METHODS: To promote plaque formation in the aorta region, ApoE KO mice were fed a high cholesterol diet (0.15% cholesterol) and orally dosed with (2,2,3,4,4,6-d(6))-cholesterol over several weeks. Tissue sections of ~10 µm thickness were analyzed by MALDI-MSI using matrix deposition by either chemical sublimation or acoustic droplet ejection. RESULTS: MALDI-MSI yielded distinct spatial distribution information for a variety of lipid classes including specific lysophosphatidylcholines typically associated with atherosclerosis-related tissue damage such as phospholipase 2 (Lp-PLA(2)) that mediate chemotactic responses to inflammation (e.g. LPC 16:0, LPC 18:0 and LPC 18:1) as well as free cholesterol and cholesteryl esters that contribute to atheroma formation. MALDI mass spectra acquired from aorta tissue sections clearly distinguished non-esterified and esterified versions of (2,2,3,4,4,6-d(6))-cholesterol within aortic plaque regions and showed distinct spatial accumulation of the cholesterol tracer. CONCLUSIONS: The ability to couple stable isotope based protocols with MALDI-MSI enables a novel strategy to characterize the effects of therapeutic treatments on atherosclerotic plaque formation, regression and potential remodeling of the complex lipid components with high chemical specificity and spatiotemporal information.

5.
Anal Chem ; 85(13): 6287-94, 2013 Jul 02.
Article in English | MEDLINE | ID: mdl-23668715

ABSTRACT

We have previously reported on a liquid chromatography-mass spectrometry method to determine the disposition of [(13)C18]-oleic acid following intravenous and oral administration in vivo. This approach has enabled us to study a variety of aspects of lipid metabolism including a quantitative assessment of triglyceride synthesis. Here we present a more rigorous evaluation of the constraints imposed upon the analytical method in order to generate accurate data using this stable-isotope tracer approach along with more detail on relevant analytical figures of merit including limits of quantitation, precision, and accuracy. The use of mass isotopomer distribution analysis (MIDA) to quantify plasma triglyceride synthesis is specifically highlighted, and a re-evaluation of the underlying mathematics has enabled us to present a simplified series of equations. The derivation of this MIDA model and the significance of all underlying assumptions are explored in detail, and examples are given of how it can successfully be applied to detect differences in plasma triglyceride synthesis in lean and high-fat diet fed mouse models. More work is necessary to evaluate the applicability of this approach to triglyceride stores with slower rates of turnover such as in adipose or muscle tissue; however, the present report provides investigators with the tools necessary to conduct such studies.


Subject(s)
Mass Spectrometry/methods , Oleic Acid/analysis , Triglycerides/biosynthesis , Triglycerides/blood , Animals , Carbon Isotopes , Mice , Mice, Inbred C57BL , Obesity/blood , Obesity/diagnosis , Oleic Acid/administration & dosage
6.
J Lipid Res ; 54(1): 276-81, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23042787

ABSTRACT

Isotopic tracers have been used to examine lipid trafficking for many years, and data from those studies have typically yielded novel insight regarding the pathophysiology of dyslipidemia. Previous experimental designs were suitable for studies in humans because relatively large volumes of plasma could be regularly sampled. We have expanded on the earlier logic by applying high-throughput analytical methods that require reduced sample volumes. Specifically, we have examined the possibility of coupling gel-based separations of lipoproteins (e.g., lipoprint) with LC-MS/MS analyses of complex lipid mixtures as a way to routinely measure the labeling profiles of distinct lipids in discrete lipoprotein subfractions. We demonstrate the ability to measure the incorporation of [U-(13)C]oleate into triglycerides (TG), PLs (PL), and cholesterol esters (CE) in VLDL, LDL, and HDL particles in mice. Although rodent models of dyslipidemia are inherently different from humans because of alterations in enzyme activities and underlying metabolism, rodent models can be used to screen novel compounds for efficacy in altering a given biochemical pathway and therein enable studies of target engagement in vivo. We expect that it is possible to translate our approach for application in other systems, including studies in humans.


Subject(s)
Chemical Fractionation/methods , Dyslipidemias/metabolism , Fatty Acids/metabolism , Lipoproteins/isolation & purification , Lipoproteins/metabolism , Animals , Biological Transport , Disease Models, Animal , Humans , Isotope Labeling , Lipoproteins/chemistry , Male , Mice , Mice, Inbred C57BL
7.
J Lipid Res ; 53(6): 1223-31, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22389331

ABSTRACT

Stable isotope tracer studies of apoprotein flux in rodent models present difficulties as they require working with small volumes of plasma. We demonstrate the ability to measure apoprotein flux by administering either (2)H- or (18)O-labeled water to mice and then subjecting samples to LC-MS/MS analyses; we were able to simultaneously determine the labeling of several proteolytic peptides representing multiple apoproteins. Consistent with relative differences reported in the literature regarding apoprotein flux in humans, we found that the fractional synthetic rate of apoB is greater than apoA1 in mice. In addition, the method is suitable for quantifying acute changes in protein flux: we observed a stimulation of apoB production in mice following an intravenous injection of Intralipid and a decrease in apoB production in mice treated with an inhibitor of microsomal triglyceride transfer protein. In summary, we demonstrate a high-throughput method for studying apoprotein kinetics in rodent models. Although notable differences exist between lipoprotein profiles that are observed in rodents and humans, we expect that the method reported here has merit in studies of dyslipidemia as i) rodent models can be used to probe target engagement in cases where one aims to modulate apoprotein production and ii) the approach should be adaptable to studies in humans.


Subject(s)
Apolipoproteins/biosynthesis , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Water/administration & dosage , Animals , Apolipoproteins/blood , Apolipoproteins/metabolism , Isotope Labeling , Male , Mice , Mice, Inbred C57BL , Peptide Fragments/metabolism , Proteolysis
8.
Int J Biol Sci ; 8(3): 310-27, 2012.
Article in English | MEDLINE | ID: mdl-22355267

ABSTRACT

Proprotein convertase subtilisin/kexin type 9 (PCSK9) is a promising therapeutic target for treating coronary heart disease. We report a novel antibody 1B20 that binds to PCSK9 with sub-nanomolar affinity and antagonizes PCSK9 function in-vitro. In CETP/LDLR-hemi mice two successive doses of 1B20, administered 14 days apart at 3 or 10 mpk, induced dose dependent reductions in LDL-cholesterol (≥ 25% for 7-14 days) that correlated well with the extent of PCSK9 occupancy by the antibody. In addition, 1B20 induces increases in total plasma antibody-bound PCSK9 levels and decreases in liver mRNA levels of SREBP-regulated genes PCSK9 and LDLR, with a time course that parallels decreases in plasma LDL-cholesterol (LDL-C). Consistent with this observation in mice, in statin-responsive human primary hepatocytes, 1B20 lowers PCSK9 and LDLR mRNA levels and raises serum steady-state levels of antibody-bound PCSK9. In addition, mRNA levels of several SREBP regulated genes involved in cholesterol and fatty-acid synthesis including ACSS2, FDPS, IDI1, MVD, HMGCR, and CYP51A1 were decreased significantly with antibody treatment of primary human hepatocytes. In rhesus monkeys, subcutaneous (SC) dosing of 1B20 dose-dependently induces robust LDL-C lowering (maximal ~70%), which is correlated with increases in target engagement and total antibody-bound PCSK9 levels. Importantly, a combination of 1B20 and Simvastatin in dyslipidemic rhesus monkeys reduced LDL-C more than either agent alone, consistent with a mechanism of action that predicts additive effects of anti-PCSK9 agents with statins. Our results suggest that antibodies targeting PCSK9 could provide patients powerful LDL lowering efficacy on top of statins, and lower cardiovascular risk.


Subject(s)
Antibodies, Monoclonal/therapeutic use , Anticholesteremic Agents/therapeutic use , Cholesterol, LDL/blood , Gene Expression Regulation/drug effects , Hepatocytes/drug effects , Immunization, Passive , Metabolic Syndrome/therapy , Proprotein Convertases/antagonists & inhibitors , Proprotein Convertases/immunology , Serine Endopeptidases/immunology , Simvastatin/therapeutic use , Sterol Regulatory Element Binding Proteins/physiology , Animals , Antibodies, Monoclonal/pharmacology , Antibody Affinity , Anticholesteremic Agents/administration & dosage , Cells, Cultured/drug effects , Cells, Cultured/metabolism , Cholesterol Ester Transfer Proteins/genetics , Cholesterol Ester Transfer Proteins/metabolism , Gene Expression Profiling , Hep G2 Cells/drug effects , Hep G2 Cells/metabolism , Hepatocytes/metabolism , Humans , Lipid Metabolism/genetics , Liver/drug effects , Liver/metabolism , Macaca mulatta , Metabolic Syndrome/drug therapy , Metabolic Syndrome/genetics , Mice , Mice, Transgenic , Proprotein Convertase 9 , Proprotein Convertases/biosynthesis , Proprotein Convertases/genetics , RNA, Messenger/metabolism , Receptors, LDL/biosynthesis , Receptors, LDL/genetics , Recombinant Proteins/metabolism , Serine Endopeptidases/biosynthesis , Serine Endopeptidases/genetics , Simvastatin/administration & dosage
9.
J Lipid Res ; 53(1): 51-65, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22021650

ABSTRACT

In an attempt to understand the applicability of various animal models to dyslipidemia in humans and to identify improved preclinical models for target discovery and validation for dyslipidemia, we measured comprehensive plasma lipid profiles in 24 models. These included five mouse strains, six other nonprimate species, and four nonhuman primate (NHP) species, and both healthy animals and animals with metabolic disorders. Dyslipidemic humans were assessed by the same measures. Plasma lipoprotein profiles, eight major plasma lipid fractions, and FA compositions within these lipid fractions were compared both qualitatively and quantitatively across the species. Given the importance of statins in decreasing plasma low-density lipoprotein cholesterol for treatment of dyslipidemia in humans, the responses of these measures to simvastatin treatment were also assessed for each species and compared with dyslipidemic humans. NHPs, followed by dog, were the models that demonstrated closest overall match to dyslipidemic humans. For the subset of the dyslipidemic population with high plasma triglyceride levels, the data also pointed to hamster and db/db mouse as representative models for practical use in target validation. Most traditional models, including rabbit, Zucker diabetic fatty rat, and the majority of mouse models, did not demonstrate overall similarity to dyslipidemic humans in this study.


Subject(s)
Disease Models, Animal , Dyslipidemias/blood , Lipids/blood , Animals , Cricetinae , Dogs , Dyslipidemias/drug therapy , Fatty Acids/blood , Humans , Mice , Primates , Simvastatin/therapeutic use , Triglycerides/blood
10.
J Cardiovasc Transl Res ; 5(1): 75-83, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22194019

ABSTRACT

To assess cardiovascular risk in both clinical and basic research settings, it is imperative to be able to accurately measure plasma lipid levels. Here, methods commonly used to measure lipoproteins and lipids: ultracentrifugation (UC), fast protein liquid chromatography (FPLC), Roche auto-analyzer, and enzymatic assays were tested and compared. Plasma samples from 20 healthy humans and 22 cynomolgus monkeys were analyzed for their total cholesterol (TC), cholesterol in low density lipoproteins (LDL) and high density lipoproteins (HDL), and triglycerides (TG). Major lipid classes from UC and FPLC separated lipoprotein fractions from human plasma were further characterized by liquid chromatography-mass spectrometry analysis. All the tested methods showed acceptable performance with Roche analyzer among the best in approximate dilution linearity and recovery for most lipids as well as in repeatability between measurements of the same samples. TC, LDL, HDL, and TG values measured in human vs. monkey were-183.9 ± 35.5 (mean ± SD) vs. 105.6 ± 24.6 mg/dl, 106.0 ± 30.1 vs. 42.8 ± 13.0 mg/dl, 50.0 ± 11.4 vs. 53.4 ± 14.8 mg/dl, and 107.6 ± 50.7 vs. 58.0 ± 52.3 mg/dl. While no single method was uniformly the best, we recommend the Roche analyzer for routine measurements. UC or FPLC separation is needed for further functional characterization for specific lipid fraction. We have shown athero-protective profile in cynomolgus monkey compared with humans.


Subject(s)
Chemistry Techniques, Analytical , Lipids/blood , Lipoproteins/blood , Adult , Animals , Autoanalysis , Biomarkers/blood , Cholesterol/blood , Cholesterol, HDL/blood , Cholesterol, LDL/blood , Chromatography, Liquid , Female , Humans , Macaca fascicularis , Male , Mass Spectrometry , Middle Aged , Reproducibility of Results , Triglycerides/blood , Ultracentrifugation
11.
Metabolism ; 61(4): 470-81, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22001333

ABSTRACT

The objective was to assess whether pharmacological activation of lecithin cholesterol acyltransferase (LCAT) could exert beneficial effects on lipoprotein metabolism. A putative small molecule activator (compound A) was used as a tool compound in in vitro and in vivo studies. Compound A increased LCAT activity in vitro in plasma from mouse, hamster, rhesus monkey, and human. To assess the acute pharmacodynamic effects of compound A, C57Bl/6 mice and hamsters received a single dose (20 mg/kg) of compound A. Both species displayed a significant increase in high-density lipoprotein cholesterol (HDLc) and a significant decrease in non-HDLc and triglycerides acutely after dosing; these changes tracked with ex vivo plasma LCAT activity. To examine compound A's chronic effect on lipoprotein metabolism, hamsters received a daily dosing of vehicle or of 20 or 60 mg/kg of compound A for 2 weeks. At study termination, compound treatment resulted in a significant increase in HDLc, HDL particle size, plasma apolipoprotein A-I level, and plasma cholesteryl ester (CE) to free cholesterol ratio, and a significant reduction in very low-density lipoprotein cholesterol. The increase in plasma CE mirrored the increase in HDL CE. Triglycerides trended toward a dose-dependent decrease in very low-density lipoprotein and HDL, with multiple triglyceride species reaching statistical significance. Gallbladder bile acids content displayed a significant and more than 2-fold increase with the 60 mg/kg treatment. We characterized pharmacological activation of LCAT by a small molecule extensively for the first time, and our findings support the potential of this approach in treating dyslipidemia and atherosclerosis; our analyses also provide mechanistic insight on LCAT's role in lipoprotein metabolism.


Subject(s)
Enzyme Activation/physiology , Lipoproteins/metabolism , Liver/metabolism , Phosphatidylcholine-Sterol O-Acyltransferase/metabolism , Thiadiazoles/pharmacology , Animals , Bile Acids and Salts/blood , Cholesterol/blood , Cholesterol Esters/blood , Cricetinae , Enzyme Activation/drug effects , Female , Lipoproteins, HDL/blood , Liver/enzymology , Magnetic Resonance Spectroscopy , Mass Spectrometry , Mesocricetus , Mice , Mice, Inbred C57BL , Thiadiazoles/chemistry , Triglycerides/blood
12.
J Lipid Res ; 52(6): 1084-1097, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21398511

ABSTRACT

Increased serum apolipoprotein (apo)B and associated LDL levels are well-correlated with an increased risk of coronary disease. ApoE⁻/⁻ and low density lipoprotein receptor (LDLr)⁻/⁻ mice have been extensively used for studies of coronary atherosclerosis. These animals show atherosclerotic lesions similar to those in humans, but their serum lipids are low in apoB-containing LDL particles. We describe the development of a new mouse model with a human-like lipid profile. Ldlr CETP⁺/⁻ hemizygous mice carry a single copy of the human CETP transgene and a single copy of a LDL receptor mutation. To evaluate the apoB pathways in this mouse model, we used novel short-interfering RNAs (siRNA) formulated in lipid nanoparticles (LNP). ApoB siRNAs induced up to 95% reduction of liver ApoB mRNA and serum apoB protein, and a significant lowering of serum LDL in Ldlr CETP⁺/⁻ mice. ApoB targeting is specific and dose-dependent, and it shows lipid-lowering effects for over three weeks. Although specific triglycerides (TG) were affected by ApoB mRNA knockdown (KD) and the total plasma lipid levels were decreased by 70%, the overall lipid distribution did not change. Results presented here demonstrate a new mouse model for investigating additional targets within the ApoB pathways using the siRNA modality.


Subject(s)
Apolipoproteins B/genetics , Atherosclerosis/genetics , Atherosclerosis/metabolism , Cholesterol Ester Transfer Proteins/genetics , Cholesterol, LDL/blood , Disease Models, Animal , Receptors, LDL/genetics , Animals , Apolipoproteins B/blood , Apolipoproteins E/blood , Apolipoproteins E/genetics , Atherosclerosis/pathology , Cell Line, Tumor , Cholesterol Ester Transfer Proteins/metabolism , Founder Effect , Gene Expression Profiling , Gene Knockdown Techniques , Hemizygote , Humans , Lipid Metabolism/genetics , Liposomes/metabolism , Liver/drug effects , Liver/metabolism , Mice , Mice, Inbred C57BL , Mice, Transgenic , Nanoparticles/administration & dosage , RNA, Messenger/analysis , RNA, Messenger/biosynthesis , RNA, Small Interfering/metabolism , RNA, Small Interfering/pharmacology , Receptors, LDL/metabolism , Triglycerides/blood
13.
J Lipid Res ; 52(6): 1150-1161, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21415123

ABSTRACT

The use of stable isotopically labeled substrates and analysis by mass spectrometry have provided substantial insight into rates of synthesis, disposition, and utilization of lipids in vivo. The information to be gained from such studies is of particular benefit to therapeutic research where the underlying causes of disease may be related to the production and utilization of lipids. When studying biology through the use of isotope tracers, care must be exercised in interpreting the data to ensure that any response observed can truly be interpreted as biological and not as an artifact of the experimental design or a dilutional effect on the isotope. We studied the effects of dosing route and tracer concentration on the mass isotopomer distribution profile as well as the action of selective inhibitors of microsomal tri-glyceride transfer protein (MTP) in mice and diacylglycerol acyltransferase 1 (DGAT1) in nonhuman primates, using a stable-isotopically labeled approach. Subjects were treated with inhibitor and subsequently given a dose of uniformly ¹³C-labeled oleic acid. Samples were analyzed using a rapid LC-MS technique, allowing the effects of the intervention on the assembly and disposition of triglycerides, cholesteryl esters, and phospholipids to be determined in a single 3 min run from just 10 µl of plasma.


Subject(s)
Carrier Proteins/metabolism , Cholesterol Esters/blood , Diacylglycerol O-Acyltransferase/metabolism , Lipid Metabolism , Lipoproteins/blood , Oleic Acid , Triglycerides/blood , Animals , Carrier Proteins/antagonists & inhibitors , Chlorocebus aethiops , Chromatography, Liquid , Drug Administration Routes , Drug Evaluation, Preclinical/methods , Enzyme Inhibitors/pharmacology , Female , Isotope Labeling/methods , Isotopes/analysis , Isotopes/blood , Male , Mass Spectrometry , Mice , Mice, Inbred C57BL , Oleic Acid/metabolism , Oleic Acid/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...