Anesthesiology ; 63(1): 41-9, 1985 Jul.
Article in English | MEDLINE | ID: mdl-3874568

ABSTRACT

The design and implementation of a computer-assisted continuous infusion (CACI) system to rapidly attain and maintain a constant plasma fentanyl concentration (PFC), as well as a CACI system that allowed the anesthesiologist to change the plasma level of fentanyl during cardiac anesthesia, were developed. In 30 patients (three groups of 10 patients each) these two automated methods of fentanyl infusion were compared with a manual fentanyl administration method. There was excellent agreement in the measured/predicted PFC ratios with the CACI stable fentanyl level system (ratio = 0.99, n = 91) and in the CACI variable fentanyl level system (ratio = 1.08, n = 79). The stable fentanyl level group of patients received significantly more (P less than 0.05) fentanyl than did the other groups. The CACI variable fentanyl level group of patients had greater hemodynamic stability, required significantly (P less than 0.05) fewer adjuvant drug interventions and experienced significantly (P less than 0.05) fewer hypotensive and hypertensive episodes than the manual, bolus fentanyl (control) group. These data show that a computer-assisted automated infusion of fentanyl is safe and as good as manual methods. CACI has greater potential as a new method of intravenous anesthesia administration.


Subject(s)
Anesthesia, Intravenous/instrumentation , Fentanyl/administration & dosage , Adult , Aged , Blood Pressure/drug effects , Computers , Coronary Artery Bypass , Evaluation Studies as Topic , Fentanyl/blood , Heart Rate/drug effects , Humans , Intraoperative Complications , Kinetics , Middle Aged , Models, Biological , Software
2.
Anesth Analg ; 64(3): 327-34, 1985 Mar.
Article in English | MEDLINE | ID: mdl-2858169

ABSTRACT

We studied the cardiovascular effects of esmolol, a newly synthesized beta-adrenocepter antagonist, in anesthetized humans. Forty patients (four groups of 10 each) with ischemic heart disease and normal ventricular function were anesthetized with diazepam, pancuronium, and N2O in O2. Esmolol was given by continuous infusion in cumulative doses of 1100 micrograms/kg (group 1), 2000 micrograms/kg (group 2), and 2700 micrograms/kg (group 3); a control group received no esmolol. Infusion of esmolol was begun 3 min prior to and ended 4 min after tracheal intubation. All three doses of esmolol significantly (P less than 0.001) attenuated the heart rate responses to intubation. Rate-pressure products were significantly (P less than 0.001) lower in esmolol-treated patients than in controls after intubation, but ST-segment changes compatible with ischemia occurred in one patient in each group. Increases in heart rate were associated with significant increases in plasma norepinephrine levels (r = 0.45, P = 0.02) in the control group, but not in esmolol-treated patients, a demonstration that esmolol antagonizes the beta-adrenergic effects of norepinephrine. The effect of esmolol on heart rate was absent 5 min after cessation of infusion, and plasma levels of esmolol were undetectable in 26 of 30 treated patients 15 min after the termination of esmolol infusion. Esmolol has a rapid onset and short duration of effect. It can be used safely during anesthesia in patients with normal ventricular function to attenuate cardiac response to sympathetic stimulation.


Subject(s)
Adrenergic beta-Antagonists/pharmacology , Anesthesia , Hemodynamics/drug effects , Propanolamines/pharmacology , Female , Humans , Male , Middle Aged