Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Surg Endosc ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38958718

ABSTRACT

BACKGROUND: Robotic suturing training is in increasing demand and can be done using suture-pads or robotic simulation training. Robotic simulation is less cumbersome, whereas a robotic suture-pad approach could be more effective but is more costly. A training curriculum with crossover between both approaches may be a practical solution. However, studies assessing the impact of starting with robotic simulation or suture-pads in robotic suturing training are lacking. METHODS: This was a randomized controlled crossover trial conducted with 20 robotic novices from 3 countries who underwent robotic suturing training using an Intuitive Surgical® X and Xi system with the SimNow (robotic simulation) and suture-pads (dry-lab). Participants were randomized to start with robotic simulation (intervention group, n = 10) or suture-pads (control group, n = 10). After the first and second training, all participants completed a robotic hepaticojejunostomy (HJ) in biotissue. Primary endpoint was the objective structured assessment of technical skill (OSATS) score during HJ, scored by two blinded raters. Secondary endpoints were force measurements and a qualitative analysis. After training, participants were surveyed regarding their preferences. RESULTS: Overall, 20 robotic novices completed both training sessions and performed 40 robotic HJs. After both trainings, OSATS was scored higher in the robotic simulation-first group (3.3 ± 0.9 vs 2.5 ± 0.8; p = 0.049), whereas the median maximum force (N) (5.0 [3.2-8.0] vs 3.8 [2.3-12.8]; p = 0.739) did not differ significantly between the groups. In the survey, 17/20 (85%) participants recommended to include robotic simulation training, 14/20 (70%) participants preferred to start with robotic simulation, and 20/20 (100%) to include suture-pad training. CONCLUSION: Surgical performance during robotic HJ in robotic novices was significantly better after robotic simulation-first training followed by suture-pad training. A robotic suturing curriculum including both robotic simulation and dry-lab suturing should ideally start with robotic simulation.

3.
European J Pediatr Surg Rep ; 12(1): e20-e22, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38259261

ABSTRACT

We present the case of a patient with gross type C esophageal atresia in a preterm neonate (gestational age of 31 weeks + 1 day) with a birth weight of 1,470 g. The fistula was released via a thoracotomy, but no primary anastomosis could be made, due to an unexpected long gap. The distal esophagus was closed and approximated to the blind pouch using traction sutures until an adjacent position was reached. A gastrostomy was created for enteral feeding. Although a second attempt to make an anastomosis was unsuccessful, the patient unexpectedly developed a suture fistula 6 weeks after the first procedure, enabling feeding via a nasogastric tube. Over time, six dilations were necessary. Full enteral feeding was achieved at the age of 6 months. Our case confirms sparse reports that deliberately creating a suture fistula may be a solution in esophageal atresia patients when an unexpected long gap prohibits a primary anastomosis.

4.
European J Pediatr Surg Rep ; 12(1): e4-e6, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38214009

ABSTRACT

We present the case of a patient with the rare type D esophageal atresia (EA), diagnosed after correction of an EA initially diagnosed as type C. Routine postoperative contrast esophagogram showed a missed proximal tracheoesophageal fistula. This case report illustrates the potential difficulties to diagnose type D EA.

SELECTION OF CITATIONS
SEARCH DETAIL
...