Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Hosp Infect ; 99(1): 8-16, 2018 May.
Article in English | MEDLINE | ID: mdl-29253622

ABSTRACT

BACKGROUND: Given the importance of monitoring healthcare-associated infections (HCAIs) and the consumption of antibiotics, a regional point prevalence survey was conducted in Liguria between March and April 2016. AIM: To measure the overall prevalence of HCAI and describe the use of antibiotics in all public hospitals. METHODS: Data on risk factors and use of antibiotics were collected for each hospitalized patient. To define the variables significantly associated with HCAI, univariate and multivariate analyses were conducted. Standardized infection ratio and standardized antimicrobial use ratio were measured for each participating hospital. FINDINGS: A total of 3647 patients were enrolled. In all, 429 HCAIs were diagnosed in 376 patients, giving a prevalence of HCAI of 10.3%. Respiratory tract (21.7%) and urinary tract (20%) were the most frequent sites of infection. High rates of meticillin-resistant Staphylococcus aureus (47.4%) and Enterobacteriaceae resistant to carbapenems (26.3%) were isolated. Forty-six percent of patients received at least one antibiotic. Combinations of penicillins including ß-lactamase inhibitors (24.1%) were the most widely used; the main indication (46.7%) was the treatment of a community-acquired infection. CONCLUSION: There was an increase in HCAI prevalence compared to a similar survey conducted in 2007; however, the performance of overlapping investigations will enable more reliable considerations. Nevertheless, data on antimicrobial resistance and use of antibiotics are consistent with the national trend. Despite methodological limitations, prevalence studies are useful to monitor HCAI over time and encourage greater awareness of the problem by all stakeholders.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Cross Infection/epidemiology , Drug Utilization , Adolescent , Adult , Aged , Aged, 80 and over , Child , Child, Preschool , Enterobacteriaceae/isolation & purification , Enterobacteriaceae Infections/epidemiology , Female , Hospitals, Public , Humans , Infant , Infant, Newborn , Italy/epidemiology , Male , Middle Aged , Prevalence , Staphylococcal Infections/epidemiology , Staphylococcus aureus/isolation & purification , Surveys and Questionnaires , Young Adult
2.
Clin Infect Dis ; 28(1): 33-8, 1999 Jan.
Article in English | MEDLINE | ID: mdl-10028067

ABSTRACT

The occurrence of legionnaires' disease has been described previously in passengers of cruise ships, but determination of the source has been rare. A 67-year-old, male cigarette smoker with heart disease contracted legionnaires' disease during a cruise in September 1995 and died 9 days after disembarking. Legionella pneumophila serogroup 1 was isolated from the patient's sputum and the ship's water supply. Samples from the air-conditioning system were negative. L. pneumophila serogroup 1 isolates from the water supply matched the patient's isolate, by both monoclonal antibody subtyping and genomic fingerprinting. None of 116 crew members had significant antibody titers to L. pneumophila serogroup 1. One clinically suspected case of legionnaires' disease and one confirmed case were subsequently diagnosed among passengers cruising on the same ship in November 1995 and October 1996, respectively. This is the first documented evidence of the involvement of a water supply system in the transmission of legionella infection on ships. These cases were identified because of the presence of a unique international system of surveillance and collaboration between public health authorities.


Subject(s)
Legionella pneumophila/isolation & purification , Legionnaires' Disease/epidemiology , Legionnaires' Disease/transmission , Ships , Water Supply , Aged , Antibodies, Monoclonal/immunology , Bacterial Typing Techniques , DNA, Bacterial/analysis , Electrophoresis, Gel, Pulsed-Field , Humans , Infection Control/methods , Italy , Legionella pneumophila/classification , Legionnaires' Disease/microbiology , Legionnaires' Disease/prevention & control , Male , Polymerase Chain Reaction/methods , Sputum/microbiology , Travel , Water Microbiology
3.
Eur J Clin Microbiol Infect Dis ; 16(12): 883-92, 1997 Dec.
Article in English | MEDLINE | ID: mdl-9495668

ABSTRACT

Fatty acid profile analysis, monoclonal antibody (MAb) subtyping, pulsed-field gel electrophoresis (PFGE), arbitrarily primed polymerase chain reaction (AP-PCR), and ribotyping were used to compare clinical and environmental Legionella pneumophila serogroup 1 isolates from an outbreak of Legionnaires' disease presumptively associated with cooling towers. According to the Oxford subtyping scheme, the MAb subtype of patients' isolates and of two strains originating from a cooling tower was Pontiac, whereas the other isolates were subtype Olda. The strains showed no intrinsic strain-to-strain difference in fatty acid profiles, and ribotyping and length polymorphism of the 16S-23S rDNA intervening regions failed to reveal any differences between the isolates. Conversely, PFGE and AP-PCR appeared to be more discriminatory, as the same genomic profile was found for the clinical and some environmental strains. Meteorologic and epidemiological data and the results of molecular analysis of the Legionella pneumophila serogroup 1 isolates support the hypothesis that the infection was transmitted from one of the cooling towers to the indoor environment of the same building, to homes in proximity that had open windows, and to the streets. In fact, the outbreak diminished and later ended after a part in the tower was replaced. This investigation demonstrates the utility of combined molecular methods (i.e., phenotypic and genomic typing) in comparing epidemiologically linked clinical and environmental isolates. Finally, the outbreak confirms the risk of Legionnaires' disease posed by cooling towers, mainly when atmospheric thermal and humidity inversions occur. This finding emphasizes the need to determine whether the source of infection is in the living or working environment or somewhere else.


Subject(s)
Disease Outbreaks , Legionella pneumophila/genetics , Legionnaires' Disease/epidemiology , Legionnaires' Disease/genetics , Water Microbiology , Adult , Aerosols , Aged , Aged, 80 and over , Air Conditioning , Bacteriological Techniques , DNA, Bacterial/analysis , DNA, Bacterial/genetics , Electrophoresis, Gel, Pulsed-Field , Environmental Microbiology , Humans , Humidity , Italy/epidemiology , Legionella pneumophila/chemistry , Legionella pneumophila/classification , Legionnaires' Disease/microbiology , Middle Aged , Polymerase Chain Reaction , Polymorphism, Restriction Fragment Length , Retrospective Studies , Serotyping , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...