1.
Eur J Med Res ; 29(1): 264, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38698476

ABSTRACT

BACKGROUND: The fundamental prerequisite for prognostically favorable postoperative results of peripheral nerve repair is stable neurorrhaphy without interruption and gap formation. METHODS: This study evaluates 60 neurorrhaphies on femoral chicken nerves in terms of the procedure and the biomechanical properties. Sutured neurorrhaphies (n = 15) served as control and three sutureless adhesive-based nerve repair techniques: Fibrin glue (n = 15), Histoacryl glue (n = 15), and the novel polyurethane adhesive VIVO (n = 15). Tensile and elongation tests of neurorrhaphies were performed on a tensile testing machine at a displacement rate of 20 mm/min until failure. The maximum tensile force and elongation were recorded. RESULTS: All adhesive-based neurorrhaphies were significant faster in preparation compared to sutured anastomoses (p < 0.001). Neurorrhaphies by sutured (102.8 [cN]; p < 0.001), Histoacryl (91.5 [cN]; p < 0.001) and VIVO (45.47 [cN]; p < 0.05) withstood significant higher longitudinal tensile forces compared to fibrin glue (10.55 [cN]). VIVO, with △L/L0 of 6.96 [%], showed significantly higher elongation (p < 0.001) compared to neurorrhaphy using fibrin glue. CONCLUSION: Within the limitations of an in vitro study the adhesive-based neurorrhaphy technique with VIVO and Histoacryl have the biomechanical potential to offer alternatives to sutured neuroanastomosis because of their stability, and faster handling. Further in vivo studies are required to evaluate functional outcomes and confirm safety.


Subject(s)
Anastomosis, Surgical , Chickens , Tensile Strength , Animals , Anastomosis, Surgical/methods , Biomechanical Phenomena , Tissue Adhesives/pharmacology , Fibrin Tissue Adhesive/pharmacology , Peripheral Nerves/surgery , Peripheral Nerves/physiology , Adhesives , Neurosurgical Procedures/methods
2.
J Orthop ; 50: 49-57, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38162259

ABSTRACT

Introduction: Thi study evalautes a new bone-preserving femoral head cover that mimics the articular cartilage of the femoral head. Methods: A specially developed polyurethane (PU) was evaluated in biocompatibility (cytotoxicity test) and mechanical response to tensile loading. In the cytotoxicity test, steam sterilized (SS) and ethylene oxide sterilized (EtO) PU samples were incubated separately in a cell culture medium. The seeded cell line MG-63 was then added to these sample-incubated cell culture mediums. One negative control group and one positive control group were also evaluated. The cells in each group were cultured for seven days before being quantified using the alamarBlue assay. In the mechanical test, the femoral head cover implants were separated into three groups of three samples. Each group represented a different implant insertion idea: direct insertion (uc sample) and another two insertion modes (is and ss samples) representing implants with enclosure mechanisms. The test consisted of distance-controlled cyclic tensile loadings followed by a failure test. Results: The cytotoxicity test results show no significant difference in fluorescence intensity between the negative control, the three SS groups, and one EtO group (P > 0.05). However, the other two EtO groups exhibit significantly lower fluorescence intensity compared with the negative control (P < 0.05). In the mechanical test, the is samples have the highest cyclic loading force at 559.50 ± 51.41 N, while the uc samples exhibit the highest force in the failure test at 632.16 ± 50.55 N. There are no significant differences (P > 0.05) among the uc, is, and ss groups in terms of stiffness. Conclusion: The cytotoxicity test and the mechanical experiment provide initial assessments of the proposed PU femoral head cover implant. The evaluation outcomes of this study could serve as a foundation for developing more functional design and testing methods, utilizing numerical simulations, and developing animal/clinical trials in the future.

3.
Sci Rep ; 13(1): 20327, 2023 11 21.
Article in English | MEDLINE | ID: mdl-37989863

ABSTRACT

Total hip arthroplasty (THA) is a common procedure for patients suffering from hip pain e.g. from osteoarthritis, osteonecrosis, or hip fractures. The satisfaction of patients undergoing THA is influenced by the choice of implant type and material, with one key factor being the selection of the appropriate material combination for the bearing surface. In this Bayesian network meta-analysis, we investigated the impact of material combinations for the bearing surface on the longevity of hip implants. The wear penetration rate per year and the total wear penetration in the liner resulting from different material combinations, as well as the survival rate at last follow-up, were examined. We analyzed a total of 663,038 THAs, with 55% of patients being women. Mean patient age was 59.0 ± 8.1 years and mean BMI 27.6 ± 2.6 kg/m2. The combination of an aluminium oxide (Al2O3) head and an Al2O3 liner demonstrated the lowest wear penetration at last follow-up and the lowest rate of wear penetration per year. Additionally, the combination of a crosslinked polyethylene (XLPE) liner and a zircon oxide (ZrO2) head demonstrated the lowest rate of revision at last follow-up. These findings underscore the importance of careful material selection for hip implant bearing surfaces to optimize their longevity and patient satisfaction after THA.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Female , Middle Aged , Aged , Male , Arthroplasty, Replacement, Hip/methods , Hip Joint/surgery , Bayes Theorem , Network Meta-Analysis , Prosthesis Failure , Polyethylene , Prosthesis Design
4.
Sci Rep ; 13(1): 12342, 2023 07 31.
Article in English | MEDLINE | ID: mdl-37524904

ABSTRACT

Tears of the anterior cruciate ligament (ACL) negatively impact the stability and kinematics of the knee. Interference screws (ISs) are used for graft fixation in ACL reconstruction and provide sufficient fixation strength to withstand the patients' activities during the graft-to-bone integration process. Magnesium is a novel material used to manufacture IS given its strength and bioabsorbability. In previous studies, the selected magnesium IS design showed a better fixation performance in comparison to the conventional IS design due to its shape design and surface condition. In this study, bioabsorbable magnesium ISs were tested for their insertion (insertion torque and a number of turns to implement the IS) and fixation performance (pull-out and dynamic test). To obtain a reliable initial assessment of IS performance, ISs were implanted in 15 per cubic foot (PCF) Sawbones polyurethane foam blocks, Sawbones biomechanical tibia models with 17 PCF foam cores, and human cadaveric tibiae. Porcine tendons were used in the foam block pull-out test, and nylon ropes were used in all other test setups to prevent influences of the ligament graft material itself. In the pull-out test, the graft was subjected to tensile stress at a rate of 6 mm/min. For the dynamic test, 1000 cycles between 0 and 200 N were performed, followed by a final pull-out test. After each test, the tunnel widening pattern was observed by measuring the aspect ratio of the tunnel at the insertion site. The insertion torque lies within the normal insertion torque of the ISs as well as the average ligament tension before the insertion. In the foam block setup, the nylon rope showed a higher pull-out force than the porcine tendon. The comparison of each setup using nylon rope for both pull-out and pull-out after the dynamic test showed no significant difference between the foam block and cadaver setup. However, all tibia model setup shows unexpectedly high pull-out force due to the influence of its cortical layer. There were no statistically significant differences in tunnel widening between foam block-porcine tendon and foam block-nylon rope constructs. The pull-out resistance of magnesium ISs falls within the typical ACL tension range during daily activities. Even though the test results of the magnesium ISs are different in each bone material, the magnesium IS shows adequate fixation ability and workability during insertion without material failure.


Subject(s)
Anterior Cruciate Ligament Injuries , Anterior Cruciate Ligament Reconstruction , Humans , Animals , Swine , Magnesium , Absorbable Implants , Nylons , Bone Screws , Tibia/surgery , Anterior Cruciate Ligament Reconstruction/methods , Biomechanical Phenomena , Anterior Cruciate Ligament Injuries/surgery
5.
Sci Rep ; 13(1): 6918, 2023 04 27.
Article in English | MEDLINE | ID: mdl-37106086

ABSTRACT

The present systematic review investigated the concentration of chromium (Cr) and cobalt (Co) in serum in patients who have undergone total hip arthroplasty (THA). The first outcome of interest was to investigate the mean concentration in serum of Cr and Co using different material combinations and to verify whether their concentrations change significantly using different patterns of head and liner in THA. The second outcome of interest was to investigate whether the time elapsed from the index surgery to the follow-up, BMI, sex, and side exert an influence on the mean concentration of Cr and Co in serum in patients who have undergone THA. The following material combinations were investigated (head-liner): Ceramic-Co Cr (CoCr), CoCr-CoCr, CoCr-Polyethylene, CoCr high carbide-CoCr high carbide. Data from 2756 procedures were retrieved. The mean length of follow-up was 69.3 ± 47.7 months. The ANOVA test evidenced good comparability in age, length of follow-up, BMI, and sex (P > 0.1). In patients who have undergone THA, the mean concentration in the serum of Co ranged between 0.5 µg/L and 3.5 µg/L, and the mean concentration of Cr from 0.6 to 2.6 µg/L. The difference in the concentration of Co and Cr in serum is strictly related to the implant configuration, with the coupling CoCr-CoCr showing the highest and CoCr-Polyethylene showing the lowest concentration. Patient characteristics, BMI, sex, side and the time elapsed from the index surgery to the last follow-up did not exert a significant influence on the concentration of Co and Cr in serum in patients who have undergone total hip arthroplasty (THA).


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Cobalt , Chromium , Bayes Theorem , Network Meta-Analysis , Polyethylene , Prosthesis Design
6.
Life (Basel) ; 13(2)2023 Feb 10.
Article in English | MEDLINE | ID: mdl-36836841

ABSTRACT

An anterior cruciate ligament (ACL) reconstruction is a common treatment for patients with ACL rupture that aims to regain pre-injury knee stability and kinematics. During the ACL reconstruction, one method to fix the graft is the use of an interference screw (IS). The IS should provide initial stability and secure the graft during the healing period. In recent years, magnesium has emerged as an alternative material to permanent metal and polymer ISs. In addition, differences in designs, such as the shape of the IS, can influence the fixation performance of the IS. Therefore, in this biomechanical experiment, two different screw designs with two ligament materials were compared in an insertion and a pull-out test at a rate of 1 mm/s. The screw designs were a conventional polymer screw and a magnesium screw. Porcine tendon and nylon rope were used as ligament materials. All tests were performed in polyurethane foam blocks with 15 PCF density (Synbone AG, Switzerland). As a result, both screw designs required an insertion torque of less than 3 Nm. There was a significant difference between the porcine and nylon rope in pull-out tests for each screw design. The magnesium screw had the highest pull-out force at 412.14 ± 50.00 N for porcine tendon and 707.38 ± 21.81 N for nylon rope. There were no significant differences in tunnel widening (narrow-wide ratio) between each ligament material. The magnesium screw showed the lowest narrow-wide tunnel ratio, implying a better ability to compress the graft to the tunnel. In conclusion, a more optimized magnesium IS design resulted in better graft fixation and an improved ACL reconstruction outcome.

7.
J Clin Med ; 11(12)2022 Jun 09.
Article in English | MEDLINE | ID: mdl-35743379

ABSTRACT

Mandible defects are conventionally reconstructed using titanium plates. However, titanium causes metallic artifacts which impair radiological imaging. This study aims at evaluating mechanical fatigue of radiolucent fiber-reinforced polyetheretherketone (f-PEEK), polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and polyphenylsulfone (PPSU) polymer plates for mandible reconstruction. A total of 30 plates (titanium [n = 6], f-PEEK [n = 6], PEEK [n = 6], PEKK [n = 6], PPSU [n = 6]) were implanted in synthetic mandibulectomized polyurethane mandibles. Servo-pneumatic mechanical testing with cyclic application of 30−300 N at 3 Hz was conducted. Bite forces were 70% on the unresected and 30% on the resected side. Total number of cycles was set to 250,000. Testing was aborted in case of plate or screw failure. Axial load to failure was tested with a speed of 1 mm/s. Kruskal−Wallis and Dunn's post hoc tests were used. Titanium, f-PEEK, and PEEK showed no failure in fatigue testing and PPSU (p < 0.001) failed against titanium, f-PEEK, PEEK, and PEKK. Titanium allowed the highest load to failure compared to f-PEEK (p = 0.049), PEEK (p = 0.008), PEKK (p < 0.001), and PPSU (p = 0.007). f-PEEK, PEEK, and PEKK withstood expected physiological bite force. Although titanium plates provided the highest fatigue strength, f-PEEK and PEEK plates showed no failure over 250,000 chewing cycles indicating sufficient mechanical strength for mandible reconstruction.