1.
J Sep Sci ; 31(2): 242-54, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18246589

ABSTRACT

A LC-MS/MS method using a LC column packed with sub-2 micron particles and elevated column temperatures was validated for the quantitation of SCH 503034 diastereomers (SCH 534128 and SCH 534129) in human plasma. The method was validated over the concentration range of 2.5 to 1250 ng/mL. Inter-assay precision, based on percent relative deviation for n = 18 replicate quality controls, was 4.5% for SCH 534128 and 4.9% for SCH 534129. Inter-assay accuracy based on n = 18 replicate quality controls was +/- 7.8% for both SCH 534128 and SCH 534129. The method involved the novel application of ion pairing reagents to increase the stereoselectivity of the separation. Temperature, types of ion pairing reagent, and concentration of ion pairing reagent were all found to play significant roles in the resolution of the SCH 534128 and SCH 534129 diastereomers on a LC column packed with sub-2 micron particles. Specifically, a sensitivity increase of five-fold was demonstrated by increasing the column temperature. Without sacrificing resolution, the run time was significantly shortened when the column temperature was elevated to 100 degrees C.


Subject(s)
Chromatography, Liquid/methods , Serine Proteinase Inhibitors/analysis , Tandem Mass Spectrometry/methods , Hydrogen-Ion Concentration , Indicators and Reagents , Reference Standards , Reproducibility of Results , Sensitivity and Specificity , Stereoisomerism , Temperature
2.
Rapid Commun Mass Spectrom ; 21(18): 3145-55, 2007.
Article in English | MEDLINE | ID: mdl-17708526

ABSTRACT

Cation-exchange micro solid-phase extraction (SPE) tips and aqueous normal-phase (ANP) chromatography coupled with tandem mass spectrometry were explored for the rapid, selective and sensitive quantitation of desloratadine and pseudoephedrine in human plasma. A novel micro-SPE device was evaluated for analyte capacity, extraction efficiency and its ability to maximize recovery of an analyte of interest from bioanalytical matrices by successive replicates of linked extraction steps. Ion suppression using two different methods with micro-SPE tips was negligible when compared to protein precipitation. The use of ANP chromatography eliminated the need for sample reconstitution following extraction and was found to be highly selective. A reliable chromatography system was developed with a short duty cycle of 2 min/sample. The proposed bioanalytical method required 50 microL of plasma for the determination of desloratadine and pseudoephedrine at limits of quantitation of 0.1 and 1.25 ng/mL, respectively. The analytical method was validated in accordance with the FDA guidance on bioanalytical method validation; selectivity, linearity, reproducibility and accuracy were all acceptable.


Subject(s)
Blood Chemical Analysis/methods , Chromatography, High Pressure Liquid/methods , Ephedrine/blood , Loratadine/analogs & derivatives , Solid Phase Microextraction/instrumentation , Solid Phase Microextraction/methods , Spectrometry, Mass, Electrospray Ionization/methods , Chromatography, High Pressure Liquid/instrumentation , Complex Mixtures/blood , Humans , Loratadine/blood , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization/instrumentation