Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Pharmacol Ther ; 83(2): 293-9, 2008 Feb.
Article in English | MEDLINE | ID: mdl-17713476

ABSTRACT

Raltegravir is a novel human immunodeficiency virus-1 integrase inhibitor with potent in vitro activity (95% inhibitory concentration (IC95)=33 nM in 50% human serum). Three double-blind, randomized, placebo-controlled, pharmacokinetic, safety, and tolerability studies were conducted: (1) single-dose escalation study (10-1,600 mg), (2) multiple-dose escalation study (100-800 mg q12 h x 10 days), and (3) single-dose female study (400 mg). Raltegravir was rapidly absorbed with a terminal half-life (t1/2) approximately 7-12 h. Approximately 7-14% of raltegravir was excreted unchanged in urine. Area under the curve (AUC)(0-infinity) was similar between male and female subjects. After multiple-dose administration, steady state was achieved within 2 days; there was little to modest accumulation of raltegravir. Trough levels were >33 nM for dose levels of 100 mg and greater. Raltegravir is generally well tolerated at doses of up to 1,600 mg/day given for up to 10 days and exhibits a pharmacokinetic profile supportive of twice-daily dosing with multiple doses of 100 mg and greater achieving trough levels >33 nM.


Subject(s)
HIV Integrase Inhibitors/administration & dosage , Organic Chemicals/administration & dosage , Administration, Oral , Adult , Area Under Curve , Double-Blind Method , Drug Administration Schedule , Female , HIV Integrase Inhibitors/adverse effects , HIV Integrase Inhibitors/pharmacokinetics , Half-Life , Humans , Male , Metabolic Clearance Rate , Organic Chemicals/adverse effects , Organic Chemicals/pharmacokinetics , Pyrrolidinones , Raltegravir Potassium , Reference Values
2.
Article in English | MEDLINE | ID: mdl-17644453

ABSTRACT

An HPLC-MS/MS method was developed for the determination of MK-0518 (raltegravir), an HIV integrase inhibitor, in human plasma over the concentration range of 2-1000 ng/mL. Stable isotope labeled (13)C(6)-MK-0518 was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction with hexane:methylene chloride in the 96-well format with a 200 microL plasma sample size. The compounds were chromatographed on an Ace C(18) (50 x 3.0 mm, 3 microm, titanium frits) column with 42.5/57.5 (v/v %) 0.1mM EDTA in 0.1% formic acid/methanol mobile phase at a flow rate of 0.5 mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for MK-0518 (m/z 445-->109) and (13)C(6)-MK-0518 (m/z 451-->367) on an Applied Biosystem API 4000 HPLC-MS/MS was used for quantitation. Intraday precision of standard curve concentrations in five different lots of control plasma was within 3.2%, while accuracy ranged from 94.8 to 106.8%. The mean extraction recovery of spiked plasma samples was 87%. Quality control (QC) samples were stored at -20 degrees C. Initial within day analysis showed QC accuracy within 7.5% of nominal with precision of 3.1% or less. The plasma QC samples were demonstrated to be stable for up to 23 months at -20 degrees C. The method described has been used to support over 18 clinical studies during Phase I through III of clinical development.


Subject(s)
Chromatography, High Pressure Liquid/methods , HIV Integrase Inhibitors/blood , Organic Chemicals/blood , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Drug Stability , Freezing , Hexanes , Humans , Methylene Chloride , Molecular Structure , Observer Variation , Pyrrolidinones , Raltegravir Potassium , Reproducibility of Results , Sensitivity and Specificity
3.
Pharmazie ; 60(5): 359-63, 2005 May.
Article in English | MEDLINE | ID: mdl-15918586

ABSTRACT

The solubility, in human urine, of the major hydroxylated metabolite (M1) of an experimental cognition enhancer was characterized through a series of in vitro experiments in an effort to estimate the probability of crystalluria occurring following oral administration of the parent compound. The aim of these experiments was to determine if a safety margin existed between clinically observed urine concentrations and the solubility of M1. The mean urine concentrations of M1 in young and elderly subjects following oral administration of the parent compound at the highest doses tested, were 4865 +/- 2368 ng/mL and 2764 +/- 791 ng/mL, respectively. In vitro solubility experiments with M1 were conducted in drug-free human urine (37 degrees C) from four male and four female healthy subjects under conditions of high and low urine osmolality. Mean concentrations (n = 16) of M1 in human urine to which solid M1 was added, were 3656 +/- 621 ng/mL, 4678 +/- 1169 ng/mL and 5378 +/- 2474 ng/mL after stirring for 24, 48 and 72 h, respectively, indicating that the ex vivo mean solubility of M1 in human urine is no greater then approximately 5 microg/mL. Addition of solid M1 to urine from human subjects dosed with the parent compound resulted in mean urine M1 concentrations 23.5% greater than those observed in vivo. The results from both experiments indicated a significant overlap between urine concentrations of M1 in vivo following the highest oral administration of the parent drug and M1 solubility measured in vitro, suggesting a high potential for in vivo saturation of urine with M1 with subsequent precipitation, crystalluria, and nephrotoxicity. Consequently, the results of these studies have placed restrictions on the dose that could be administered during clinical development of this compound.


Subject(s)
Kidney Diseases/chemically induced , Phthalazines/toxicity , Phthalazines/urine , Psychotropic Drugs/toxicity , Psychotropic Drugs/urine , Triazoles/toxicity , Triazoles/urine , Animals , Chromatography, High Pressure Liquid , Female , Humans , Hydroxylation , Kidney Diseases/urine , Male , Mass Spectrometry , Rats , Solubility , Temperature
4.
J Pharm Biomed Anal ; 24(2): 291-305, 2000 Dec 15.
Article in English | MEDLINE | ID: mdl-11130208

ABSTRACT

A method for the simultaneous determination of the HIV protease inhibitors indinavir and L-756423, in human plasma has been developed. Plasma samples (0.5 ml) were extracted using a 3M Empore 96-well plate in the mixed phase cation exchange (MPC) format. The extraction method was automated through the application of both the Packard 204DT and TOMTEC Quadra 96 work stations, and the resulting extracts were analyzed using a PE-Sciex API-3000 LC-MS/MS with a heated nebulizer interface (500 degrees C). The assay was linear in the concentration range 1-2500 ng/ml for indinavir and 5 2500 ng/ml for L-756423 when 0.5-ml aliquots of plasma were extracted. Recoveries of indinavir and L-756423 were greater than 76 and 80%, respectively, over the calibration curve range when using the described sample preparation method. Within-batch precision and accuracy for the quantitation of indinavir over the range 1-2500 ng/ml were 5.4% R.S.D. or less and within 4.0%, respectively. Within-batch precision and accuracy for the quantitation of L-756423 over the range 5-2500 ng/ml were 5.3% R.S.D. or less and within 3.4%, respectively. Interbatch variability for the analysis of indinavir QC samples at low (3 ng/ml), middle (250 ng/ml) and high (2250 ng/ml) were 3.2, 2.9, and 1.9%, respectively. Interbatch variability for the analysis of L-756423 QC samples at low (15 ng/ml), middle (250 ng/ml) and high (2250 ng/ml) concentration were 2.0, 2.5, and 3.3%, respectively. The validated assay was used in support of human clinical trials.


Subject(s)
Anti-HIV Agents/blood , Chromatography, Liquid/methods , HIV Protease Inhibitors/blood , Indans/blood , Indinavir/blood , Mass Spectrometry/methods , Piperazines/blood , Anti-HIV Agents/pharmacokinetics , Automation , HIV Protease Inhibitors/pharmacokinetics , Humans , Indans/pharmacokinetics , Indinavir/pharmacokinetics , Piperazines/pharmacokinetics , Reference Standards , Reproducibility of Results
5.
J Chromatogr B Biomed Sci Appl ; 732(2): 425-35, 1999 Sep 24.
Article in English | MEDLINE | ID: mdl-10517365

ABSTRACT

A method for the determination of L-756 423, a novel HIV protease inhibitor, in human plasma and urine is described. Plasma and urine samples were extracted using 3M Empore extraction disk cartridges in the C18 and MPC (mixed-phase cation-exchange) formats, respectively. The extract was analyzed using HPLC with fluorescence detection (ex 248 nm, em 300 nm), and included a column switching procedure to reduce run-time. The assay was linear in the concentration range 5 to 1000 ng/ml when 1-ml aliquots of plasma and urine were extracted. Recoveries of L-756 423 were greater than 84% over the calibration curve range using the described sample preparation procedures. Intra-day precision and accuracy for this assay was less than 9% RSD and within 7%, respectively. Inter-day variabilities for the plasma (n=17) and urine (n= 10) were less than 5% and 3% for low (15 ng/ml) and high (750 ng/ml) quality control samples. Bovine serum albumin (0.5%) was used as an additive to urine to prevent precipitation of L-756 423 during the storage of clinical samples. The assay was used in support of human clinical trials.


Subject(s)
Chromatography, High Pressure Liquid/methods , HIV Protease Inhibitors/analysis , Indans/analysis , Piperazines/analysis , Drug Stability , HIV Protease Inhibitors/blood , HIV Protease Inhibitors/urine , HIV-1/drug effects , Humans , Indans/blood , Indans/urine , Piperazines/blood , Piperazines/urine , Reference Standards , Reproducibility of Results , Research , Spectrometry, Fluorescence/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...