Curr Eye Res ; 41(3): 305-10, 2016.
Article in English | MEDLINE | ID: mdl-25974410

ABSTRACT

PURPOSE/AIM OF THE STUDY: The aim of this study is to investigate the effect of pseudoexfoliation (PEX) and PEX-induced dry eye on central corneal thickness (CCT). MATERIALS AND METHODS: This cross-sectional study consists of total 270 eyes of 135 patients (67 females, 68 males) in total. After excluding the PEX (-) 32 eyes with PEX in the other eye, totally 130 eyes in PEX (-) group and 108 eyes in the PEX (+) group were included in the study. The PEX (+) group was regrouped as PEX syndrome (80 eyes of 50 patients) and PEX glaucoma (28 eyes of 20 patients). RESULTS: In the PEX (-) group, the mean Schirmer test result was 12 ± 4 mm (4-25 mm), in the PEX syndrome group 10 ± 4 mm (4-22 mm), in the PEX glaucoma group 9 ± 3 mm (4-15 mm). The difference among the PEX (-) group, the PEX syndrome and the PEX glaucoma groups was statistically significant (p < 0.001, p < 0.001, respectively). In the PEX (-) group, the mean tear break up time test result was 11 ± 2 s (5-16 s), in the PEX syndrome group 8 ± 3 (3-16 s), in the PEX glaucoma group 8 ± 3 s (5-15 s). Mean CCT result was 544 µm in the PEX (-), 521 µm in the PEX syndrome group and 533 µm in the PEX glaucoma group. The difference among the PEX (-) group, the PEX syndrome and the PEX glaucoma groups was significant (p < 0.001, p = 0.030, respectively). There was a significant (+) correlation between intraocular pressure and CCT in the eyes with PEX (r = 0.307, p = 0.001). However, there was no statistically significant correlation between CCT, Schirmer and tear break up time tests in the eyes with PEX. CONCLUSIONS: PEX material can cause decrease in tear film secretion and disturb tear film stability. There is no effect of PEX-induced dry eye on CCT. Lower CCT values in the eyes with PEX material may be a result of decrease in corneal stromal cell density. Moreover, higher CCT values may be because of decreased endothelial cells in PEX glaucoma patients.


Subject(s)
Cornea/pathology , Dry Eye Syndromes/physiopathology , Exfoliation Syndrome/physiopathology , Aged , Corneal Pachymetry , Cross-Sectional Studies , Female , Humans , Intraocular Pressure/physiology , Male , Organ Size , Tears/chemistry , Tonometry, Ocular , Visual Acuity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...