Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Radiology ; 168(1): 49-58, 1988 Jul.
Article in English | MEDLINE | ID: mdl-3289095

ABSTRACT

Detectability of breast cancer with magnetic resonance (MR) imaging versus xeromammography was quantitatively compared. MR images were obtained of breasts of 120 women who underwent xeromammography. T1 values were determined for masses larger than 2 cm. Cancer was histologically confirmed in 39 breasts and was considered excluded from 81 due to results of biopsy, cyst aspiration, or sonography or absence of change in xeromammographic findings over time. Images were blindly interpreted by three observers, and results were expressed as receiver operating characteristic curves. Detectability of breast cancer was substantially better with xeromammography than with MR imaging for all observers (P less than .03, 10(-6), and .001). On MR images, spiculation of a mass, distorted architecture, skin thickening, and nipple or skin retraction were specific but relatively insensitive indicators of cancer. Masses with smooth, distinct margins and signal intensity greater than that of fat on T2-weighted images were always benign. Other findings and T1 values were not diagnostically useful. The authors conclude that xeromammography is superior to MR imaging in detection of breast cancer.


Subject(s)
Breast Neoplasms/diagnosis , Magnetic Resonance Imaging , Mammography , Xeromammography , Breast Diseases/diagnosis , Breast Diseases/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Female , Humans , Middle Aged , ROC Curve , Sensitivity and Specificity
2.
Radiology ; 160(2): 299-305, 1986 Aug.
Article in English | MEDLINE | ID: mdl-3726104

ABSTRACT

We tested a variety of inversion-recovery (IR) and spin-echo (SE) sequences by imaging the breast masses of 22 patients before surgery and 23 tissue specimens with magnetic resonance (MR) imaging at 0.6 T to determine the most effective pulse sequences to evaluate breast disease. An SE pulse sequence using a long repetition time (TR) of 1,600 msec and a long echo time (TE) of 90 msec was found to be the most sensitive in depicting carcinoma in the excised tissue specimens, with all of the carcinomas (n = 15) demonstrating irregular areas of higher signal intensity (SI) than that of the adjacent fat. However, only five of 11 breast carcinomas present in the preoperative patients produced a higher SI than that produced by fat on the same T2-weighted sequence. Five of the remaining six carcinomas in the preoperative patients appeared as localized distortions of fibroductular architecture on both T2-weighted SE and IR sequences. In axillary tissue specimens, both metastatic carcinoma and hyperplastic lymph nodes produced a high SI on T2-weighted SE sequences. However, metastatic carcinoma had a significantly longer T2 relaxation time than did hyperplastic lymph nodes.


Subject(s)
Axilla/pathology , Breast Diseases/diagnosis , Breast Neoplasms/diagnosis , Magnetic Resonance Spectroscopy , Adenofibroma/diagnosis , Adenofibroma/pathology , Breast Diseases/pathology , Breast Neoplasms/pathology , Carcinoma/diagnosis , Carcinoma/pathology , Female , Fibrocystic Breast Disease/diagnosis , Fibrocystic Breast Disease/pathology , Hematoma/diagnosis , Hematoma/pathology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...