Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Ann Thorac Surg ; 103(3): e227-e229, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28219553

ABSTRACT

Left ventricular pseudoaneurysms have become a rare complication of acute myocardial infarction, occurring in approximately 2% of cases and even less frequently when primary percutaneous intervention can be performed. Regardless of treatment strategy, left ventricle pseudoaneurysms are associated with a high mortality rate. We report on the extremely rare occurrence of a patient surviving two episodes of free wall rupture associated with extensive chest wall destruction and secondary traumatic rib fractures. The key to success in this case is related to both the cardiac and chest wall repair.


Subject(s)
Aneurysm, False/surgery , Heart Aneurysm/complications , Heart Aneurysm/surgery , Thoracic Wall/surgery , Aneurysm, False/complications , Aneurysm, False/diagnostic imaging , Echocardiography , Heart Aneurysm/diagnostic imaging , Heart Rupture, Post-Infarction/complications , Heart Ventricles , Humans , Male , Middle Aged , Tomography, X-Ray Computed
2.
Rev Port Cardiol ; 35(3): 133-8, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26919889

ABSTRACT

INTRODUCTION AND OBJECTIVES: To investigate the incidence and clinical relevance of the presence of mobile echogenic images (MEI) during transesophageal echocardiography (TEE) for monitoring of transcatheter aortic valve implantation (TAVI). METHODS: Consecutive patients referred to our center for transfemoral or transapical TAVI were included. The procedure was monitored by three-dimensional (3D) TEE and images were analyzed by two independent experts. In-hospital follow-up was carried out and correlated with imaging findings. RESULTS: A total of 104 patients were included. MEI were visualized in 11 patients during the procedure (11%) and in over 50% of cases were identified as thrombi, however no differences in periprocedural stroke were found in follow-up. CONCLUSIONS: Visualization of MEI during 3D TEE monitoring of TAVI is relatively common (11%) and in over 50% of cases they are identified as thrombi. The clinical implications of this finding are uncertain, as despite their frequency, the incidence of clinical stroke in this patient population was no higher. 3D TEE is a useful tool for diagnosis of MEI and can alert the operator to their presence.


Subject(s)
Aortic Valve Stenosis/diagnosis , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Imaging, Three-Dimensional , Incidence
3.
Rev. esp. cardiol. (Ed. impr.) ; 69(1): 37-44, ene. 2016. graf, tab
Article in Spanish | IBECS | ID: ibc-149527

ABSTRACT

Introducción y objetivos: El implante percutáneo de válvula aórtica se utiliza como alternativa a la sustitución valvular quirúrgica para pacientes con estenosis aórtica grave de alto riesgo quirúrgico o inoperables. Dos de las principales áreas de incertidumbre son la durabilidad de la válvula y la supervivencia a largo plazo. Métodos: Registro unicéntrico prospectivo de un hospital terciario que incluyó consecutivamente todos los implantes percutáneos de válvula aórtica entre 2008 y 2012. Se realizó seguimiento clínico durante un mínimo de 2,5 años y un máximo de 6,5 años. Se utilizaron definiciones Valve Academic Research Consortium-2. Resultados: Se incluyó a 79 pacientes, con un éxito inmediato del 94,9%. La mediana de supervivencia fue de 47,6 (intervalo de confianza del 95%, 37,4-57,9) meses, es decir, 4 años. Un cuarto de las muertes sucedieron en el primer mes, la mayoría de causa cardiovascular. Después del primer mes, la causa más frecuente fue no cardiovascular. Los valores medios de gradientes valvulares no se incrementaron en el seguimiento. La tasa acumulada de disfunción protésica fue del 15,3%, sin ningún caso de resustitución valvular. Conclusiones: La mitad de los pacientes con estenosis aórtica intervenidos mediante implante percutáneo de válvula aórtica sobreviven 4 años después del procedimiento. Se detectó un 15,3% de disfunción protésica en el seguimiento acumulado, sin casos de resustitución valvular (AU)


Introduction and objectives: Transcatheter aortic valve implantation is used as an alternative to surgical valve replacement in patients with severe aortic stenosis who are considered high-surgical-risk or inoperable. Two of the main areas of uncertainty in this field are valve durability and long-term survival. Methods: This prospective single-center registry study from a tertiary hospital included all consecutive patients who underwent percutaneous aortic valve implantation between 2008 and 2012. Clinical follow-up lasted a minimum of 2.5 years and a maximum of 6.5 years. Valve Academic Research Consortium-2 definitions were used. Results: Seventy-nine patients were included, with an immediate success rate of 94.9%. The median survival was 47.6 months (95% confidence intervals, 37.4-57.9 months), ie, 4 years. One quarter of deaths occurred in the first month, and most were of cardiovascular cause. After the first month, most deaths were due to noncardiovascular causes. The mean values of valve gradients did not increase during follow-up. The cumulative rate of prosthetic valve dysfunction was 15.3%, with no cases of repeat valve replacement. Conclusions: Half of the patients with aortic stenosis who underwent transcatheter aortic valve implantation were alive 4 years after the procedure. There was a 15.3% prosthetic valve dysfunction rate in cumulative follow-up, with no cases of repeat valve replacement (AU)


Subject(s)
Humans , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/surgery , Time , Transcatheter Aortic Valve Replacement/methods , Prospective Studies
4.
Rev Esp Cardiol (Engl Ed) ; 69(1): 37-44, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26234997

ABSTRACT

INTRODUCTION AND OBJECTIVES: Transcatheter aortic valve implantation is used as an alternative to surgical valve replacement in patients with severe aortic stenosis who are considered high-surgical-risk or inoperable. Two of the main areas of uncertainty in this field are valve durability and long-term survival. METHODS: This prospective single-center registry study from a tertiary hospital included all consecutive patients who underwent percutaneous aortic valve implantation between 2008 and 2012. Clinical follow-up lasted a minimum of 2.5 years and a maximum of 6.5 years. Valve Academic Research Consortium-2 definitions were used. RESULTS: Seventy-nine patients were included, with an immediate success rate of 94.9%. The median survival was 47.6 months (95% confidence intervals, 37.4-57.9 months), ie, 4 years. One quarter of deaths occurred in the first month, and most were of cardiovascular cause. After the first month, most deaths were due to noncardiovascular causes. The mean values of valve gradients did not increase during follow-up. The cumulative rate of prosthetic valve dysfunction was 15.3%, with no cases of repeat valve replacement. CONCLUSIONS: Half of the patients with aortic stenosis who underwent transcatheter aortic valve implantation were alive 4 years after the procedure. There was a 15.3% prosthetic valve dysfunction rate in cumulative follow-up, with no cases of repeat valve replacement.


Subject(s)
Aortic Valve Stenosis/surgery , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Cause of Death/trends , Echocardiography , Female , Follow-Up Studies , Humans , Male , Prognosis , Prospective Studies , Severity of Illness Index , Spain/epidemiology , Survival Rate/trends , Time Factors
5.
Rev Port Cardiol ; 34(11): 665-72, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26604049

ABSTRACT

INTRODUCTION: A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system. OBJECTIVE: To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors. METHODS: We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients. RESULTS: A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013). CONCLUSION: The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Pacemaker, Artificial , Aortic Valve/surgery , Cardiac Catheterization/adverse effects , Electrocardiography , Heart Valve Prosthesis/adverse effects , Humans , Incidence , Treatment Outcome
6.
Rev Port Cardiol ; 34(10): 587-95, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26427801

ABSTRACT

OBJECTIVE: To analyze long-term survival and predictors of mortality in patients evaluated for transcatheter aortic valve implantation (TAVI) depending on the decision taken by the heart team. METHODS: All patients with severe aortic stenosis and high surgical risk evaluated for TAVI between June 2008 and June 2012 were included. Patients were grouped according to the therapeutic strategy decided by the heart team. Mean follow-up was 16.6 months (maximum 55.3). RESULTS: A total of 149 patients were evaluated: 79 were accepted for TAVI, 12 had no current indication for valve replacement and were deferred, 13 were redirected to conventional surgery and 45 received medical treatment. The evaluated patients had a mean age of 83.7 years and a mean EuroSCORE of 19.8±12.3. Median survival free from all-cause death was 34.7 months (95% CI 27.1-42.3) in the TAVI group, 47.4 months (95% CI 0-97.4) in the deferred intervention group, not available in the surgery group and 8.2 months (95% CI 5.6-10.9) in the medical treatment group (log-rank p<0.001). After multivariable adjustment, only treatment group remained as an independent predictor of mortality. Considering the TAVI group as the reference category, the adjusted hazard ratio for all-cause death was 0.70 (95% CI 0.24-2.04) for the deferred intervention group, 0.16 (95% CI 0.02-1.19) for the surgery group and 2.47 (95% CI 1.46-4.18) for the medical treatment group. CONCLUSION: The decision taken by the heart team on potential candidates for TAVI has a decisive prognostic significance, as those who are unsuitable for any kind of valve replacement have a significantly higher mortality.


Subject(s)
Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Clinical Decision-Making , Patient Selection , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Prognosis , Risk Factors , Survival Rate , Time Factors
7.
J Cardiol Cases ; 7(6): e164-e167, 2013 Jun.
Article in English | MEDLINE | ID: mdl-30533153

ABSTRACT

Primary cardiac sarcomas are rare. A 63-year-old woman presented with progressive symptoms of fatigue, palpitations, and dyspnea. Transthoracic echocardiography detected a mass in the left atrium, fixed and probably attached to the interatrial septum suggestive of myxoma. Transesophageal echocardiography confirmed the existence of a large lobulated mass in the left atrium measuring 45 mm × 25 mm in diameter. Subsequent cardiac magnetic resonance imaging showed a mass of heterogeneous appearance, with broad base of implantation on the posterior wall of the left atrium. The extension study with multidetector computed tomography showed superficial infiltration of the atrial wall, without involvement of the mitral valve or pulmonary veins and no extension to other extracardiac structures. The patient underwent surgery resecting a bilobed mass, smooth and yellowish, strongly attached to the posterior wall of left atrium. The pathologic study was consistent with the diagnosis of myxofibrosarcoma. .

8.
Food Chem Toxicol ; 62: 856-8, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24416776

ABSTRACT

The aim of this study was to analyze barium, bismuth, chromium, lithium, and strontium contents in food and beverages consumed by the population of the Canary Islands (Spain) as well as determine dietary intake of these metals in the archipelago as a whole and in its individual islands. To this end, 440 samples were analyzed by ICP-OES and GFAAS. Barium concentrations ranged from 5.210 ± 2.117 mg/kg in nuts to 0.035 ± 0.043 mg/L in water. Viscera exhibited the highest levels of bismuth (38.07 ± 36.80 mg/kg). The cold meat and sausages group stood out for its high chromium concentrations (0.494 ± 0.257 mg/kg). The highest concentration of lithium and strontium came out in nuts (8.761 ± 5.368 mg/kg and 9.759 ± 5.181 mg/kg, respectively). The total intakes of barium, bismuth, chromium, lithium, and strontium were 0.685, 1.274, 0.087, 3.674, and 1.923 mg/day, respectively. Cereals turned out to contribute most to the dietary intake of barium, bismuth, chromium, and lithium in the Canary Islands, while fruit contributes most to the strontium intake. We also performed a metal intake study by age and sex of the population and compared the outcome with data from other regions, both national and international.


Subject(s)
Barium/analysis , Bismuth/analysis , Chromium/analysis , Food Analysis , Lithium/analysis , Strontium/analysis , Barium/administration & dosage , Bismuth/administration & dosage , Chromium/administration & dosage , Food Contamination , Humans , Lithium/administration & dosage , Spain , Strontium/administration & dosage
9.
World J Cardiol ; 4(1): 8-14, 2012 Jan 26.
Article in English | MEDLINE | ID: mdl-22279599

ABSTRACT

AIM: To study a cohort of consecutive patients undergoing transcatheter aortic valve implantation (TAVI) and compare the outcomes of atrial fibrillation (AF) patients vs patients in sinus rhythm (SR). METHODS: All consecutive patients undergoing TAVI in our hospital were included. The AF group comprised patients in AF at the time of TAVI or with history of AF, and were compared with the SR group. Procedural, echocardiographic and follow-up variables were compared. Likewise, the CHA(2)DS(2)-VASC stroke risk score and HAS-BLED bleeding risk score and antithrombotic treatment at discharge in AF patients were compared with that in SR patients. RESULTS: From a total of 34 patients undergoing TAVI, 17 (50%) were allocated to the AF group, of whom 15 (88%) were under chronic oral anticoagulation. Patients in the AF group were similar to those in the SR group except for a trend (P = 0.07) for a higher logistic EuroSCORE (28% vs 19%), and a higher prevalence of hypertension (82% vs 53%) and chronic renal failure (17% vs 0%). Risk of both stroke and bleeding was high in the AF group (mean CHA(2)DS(2)-VASC 4.3, mean HAS-BLED 2.9). In the AF group, treatment at discharge included chronic oral anticoagulation in all except one case, and in association with an antiplatelet drug in 57% of patients. During a mean follow-up of 11 mo (maximum 32), there were only two strokes, none of them during the peri-procedural period: one in the AF group at 30 mo and one in the SR group at 3 mo. There were no statistical differences in procedural success, and clinical outcome (survival at 1 year 81% vs 74% in AF and SR groups, respectively, P = NS). CONCLUSION: Patients in AF undergoing TAVI show a trend to a higher surgical risk. However, in our cohort, patients in AF did not have a higher stroke rate compared to the SR group, and the prognosis was similar in both groups.

10.
Rev Port Cardiol ; 31(2): 143-9, 2012 Feb.
Article in Portuguese | MEDLINE | ID: mdl-22240099

ABSTRACT

INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is an alternative to surgical aortic valve replacement in patients with severe aortic stenosis (AS) and unacceptably high surgical risk. METHODS: We present our first two years' experience with TAVI. A total of 76 AS patients were evaluated for TAVI and 23 of them underwent a TAVI procedure. These patients had a mean EuroSCORE of 22.4% and a mean age of 81.5 years, and were prospectively followed for a mean of 12.9 ± 11 months. RESULTS: The percutaneous aortic valve was successfully implanted in 100% of the patients. Mortality at 30 days was 4%. The most common complications were access site-related bleeding and transfusion (22%), followed by new permanent pacemaker implantation (9%). After a mean follow-up of 12.9 months, survival was 87%. In a maximum follow-up of 30 months there were no cases of prosthesis dysfunction or cardiovascular death. CONCLUSIONS: Two years after the introduction of a TAVI program in our center, the procedure has established itself as a safe and effective alternative for patients with severe AS and unacceptably high surgical risk.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiac Catheterization , Heart Valve Prosthesis Implantation/methods , Aged , Aged, 80 and over , Female , Humans , Male , Prospective Studies , Prosthesis Design , Risk Factors
11.
J Am Soc Echocardiogr ; 24(2): 227.e5-8, 2011 Feb.
Article in English | MEDLINE | ID: mdl-20674270

ABSTRACT

A 26-year-old woman presented with acute hemolysis 1 month after percutaneous closure of an atrial septal defect. Three-dimensional transesophageal echocardiography was used to establish the diagnosis of a fistula from the aorta, toward the device and both atria. The patient required urgent surgical correction. Transcatheter closure of atrial septal defects has proven to be a highly successful alternative to surgery in the appropriate patient. Cardiac perforation and device erosion of the aortic wall are infrequent but potentially lethal complications of percutaneous occluder device insertion. Supportive features of device erosion include a wrong preimplantation assessment of the rims, the device extends across the atrial septum, and the device encroaches on the surrounding structures. In this case, the presumed mechanism of aortic fistula was aortic erosion by the left atrial disk of the occluder device.


Subject(s)
Aorta/diagnostic imaging , Aorta/injuries , Cardiac Catheterization/adverse effects , Heart Septal Defects, Atrial/surgery , Adult , Female , Heart Septal Defects, Atrial/complications , Humans , Ultrasonography
13.
Med. clín (Ed. impr.) ; 133(11): 414-421, sept. 2009. ilus, tab
Article in Spanish | IBECS | ID: ibc-76879

ABSTRACT

Fundamento y objetivo: El objetivo de este estudio es el de comparar la calidad de vida de pacientes ancianos a los que se les ha realizado cirugía de recambio valvular aórtico (RVA) con la de la población general española de la misma edad y del mismo sexo. Pacientes: Se analizó un total de 163 pacientes con una edad igual o superior a 75 años que habían recibido RVA. La calidad de vida se evaluó con el test SF-12 (Short Form Health Survey 12). La mediana del período de seguimiento fue de 37,4 meses. El seguimiento se completó en un 95,6% de los pacientes supervivientes. Los resultados se compararon con los datos publicados para la población general española de la misma edad y del mismo sexo (n=1.312). Resultados: La mortalidad hospitalaria fue del 7,4%. El resultado medio de los componentes sumarios físico y mental fue para las mujeres de 44,69 y de 49,88, y para los varones de 47,38 y de 56,19, respectivamente. Al confrontarlos con la población general española, los pacientes intervenidos mostraron un estado de salud comparable. Conclusiones: Los pacientes ancianos candidatos a RVA representan un grupo de alto riesgo quirúrgico. Sin embargo, la calidad de vida postoperatoria es comparable a la de la población general de la misma edad y del mismo sexo (AU)


Background and objective: The aim of the study was to compare the quality of life of elderly patients undergoing aortic valve replacement with that of a reference group. Patients: A total of 163 patients aged ⩾75 years who underwent aortic valve replacement were analyzed. Quality of life was evaluated by the Short Form Health Survey test 12 (SF-12). The median follow-up period was 37.4 months. Quality of life follow-up was complete at 95.6% of mid-term survivors. Quality of life data was compared with published data of a sample of the Spanish population (n.1312) of the same age and same sex .Results: Overall 30-day mortality was 7.4%. The mean SF-12 physical component score and SF-12 mental component score of the study population were 44,69 and 49,88 for woman and 47,38 and 56,19 for men, respectively. Results: Our sample population showed a post operative quality of live comparable with that of the general population. Conclusions: Elderly patients who are candidates to aortic valve replacement represent a high risk population. Nevertheless, the quality of life achieved post-operatively is comparable with that of the general population (AU)


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , /methods , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Femoral Artery , Catheterization
14.
Med Clin (Barc) ; 133(11): 414-21, 2009 Sep 26.
Article in Spanish | MEDLINE | ID: mdl-19674759

ABSTRACT

BACKGROUND AND OBJECTIVE: In recent years, techniques for implantation of aortic prosthesis via catheter have been developed as a therapeutic alternative in patients with severe aortic stenosis rejected for surgery. The correct selection of candidates is one of the more complex aspects of this treatment. We analyzed the acceptance rate in our environment for transcatheter aortic valve implantation in patients referred to our hospital for evaluation as possible candidates, describing the exclusion reasons. PATIENTS AND METHOD: 30 patients with severe aortic stenosis and rejected for surgical aortic valve replacement were referred to our hospital to evaluate transcatheter aortic valve implantation. The patients first underwent clinical evaluation and were studied with echocardiography, angiography and computed tomography. RESULTS: Of the 30 patients, 18 were rejected for the procedure (60%): 4 patients with non-severe aortic stenosis, 2 asymptomatic patients, 2 patients who finally underwent surgery because of a low-surgical-risk, 5 patients with contraindications for the procedure, 2 patients who finally did not want to undergo the procedure and 3 patients were further rejected because the vascular access was inappropriate. Of the remaining 12 patients initially accepted, 3 died before the procedure was performed. Finally, only 9 patients (30%) underwent transcatheter aortic valve implantation. CONCLUSIONS: Of the patients referred for transcatheter aortic valve implantation, only 40% were accepted. The mortality rate during the evaluation process of this procedure is high, showing that these patients are terminally ill.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Aged , Aged, 80 and over , Catheterization , Female , Femoral Artery , Humans , Male
15.
J Am Coll Cardiol ; 44(8): 1641-7, 2004 Oct 19.
Article in English | MEDLINE | ID: mdl-15489097

ABSTRACT

OBJECTIVES: We sought to determine the prevalence and predisposing condition for aortic wall complications in adults with either repaired or non-repaired coarctation of the aorta. BACKGROUND: Aortic wall complications may develop in adults with coarctation of the aorta, despite successful surgical repair in childhood. METHODS: A total of 235 adults with coarctation (mean age 27 +/- 13 years) were retrospectively reviewed. Treatment had been performed by surgery in 181 patients (group I) or by balloon angioplasty or stenting in 28 patients (group II). No previous intervention had been carried out in 26 patients with mild coarctation at diagnosis (group III). RESULTS: Forty-four aortic wall complications were found in 37 patients (16%). There were no differences among the three groups with respect to total complications (15%, 18%, and 15%, respectively), ascending aortic aneurysms (9%, 11%, and 12%), or descending aortic aneurysms (4% in all three groups). Multivariate analysis did not show a significant relationship between previous repair, type of repair, age at repair, residual Doppler pressure gradient, or systemic hypertension and the occurrence of aortic complications. Only aging (risk ratio [RR] 1.4 per decade of age, 95% confidence interval [CI] 1.1 to 1.8, p = 0.002) and bicuspid aortic valve (RR 3.2, 95% CI 1.3 to 7.5, p = 0.005) were significantly related to these complications. CONCLUSIONS: Aortic wall complications are frequent in adults with coarctation of the aorta beyond that attributable to associated hemodynamic derangement or previous repair. The only independent risk factors appear to be advanced age and bicuspid aortic valve.


Subject(s)
Aortic Aneurysm/etiology , Aortic Coarctation/complications , Adolescent , Adult , Age Factors , Aged , Angioplasty, Balloon , Aortic Aneurysm/epidemiology , Aortic Aneurysm/therapy , Aortic Coarctation/epidemiology , Aortic Coarctation/therapy , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Multivariate Analysis , Retrospective Studies , Risk Factors , Spain , Stents
16.
Am J Cardiol ; 89(1): 39-43, 2002 Jan 01.
Article in English | MEDLINE | ID: mdl-11779520

ABSTRACT

The aims of this study were to determine the prevalence and predisposing conditions for atrial fibrillation (AF) in adults with atrial septal defect (ASD) and to evaluate the influence of age at surgical repair. The study population consisted of 286 adults with ASD (mean age 39.5 +/- 19 years). All patients had >or = 1 follow-up visit and a Doppler echocardiographic study. One hundred ninety-two of the patients underwent surgical closure 1 to 34 years before the study. Analyzed variables were entered into univariate (Mann-Whitney U) and multivariate (stepwise logistic regression) models to assess independent predictors for AF. The prevalence of AF was similar in surgically treated patients (15.6%) and in the nonsurgical group (13.8%) (p = 0.69). Multivariate analysis showed that current age (RR 1.9 per each decade of age, 95% confidence interval [CI] 1.3 to 2.7, p = 0.001), mitral regurgitation (RR 3.0 per each degree of regurgitation, 95% CI 1.6 to 5.8, p = 0.001), left atrial enlargement (RR 2.8 per each 10 mm increase in size, 95% CI 1.5 to 5.2, p = 0.001), and tricuspid regurgitation (RR 1.9 per each degree of regurgitation, 95% CI 1.0 to 3.7, p = 0.04) were independent predictors of AF; however, gender, anatomic type, defect size, Qp:Qs, pulmonary artery pressure, right ventricular dimension, left ventricular shortening fraction, and prior surgical repair were not related to late AF development. In the surgical group, age >25 years at the time of surgery was the only predictor for AF independent of age at the time of the study (p = 0.02).


Subject(s)
Atrial Fibrillation/epidemiology , Atrial Fibrillation/etiology , Heart Septal Defects, Atrial/complications , Heart Septal Defects, Atrial/surgery , Adolescent , Adult , Age Distribution , Age Factors , Aged , Aged, 80 and over , Echocardiography, Doppler , Female , Heart Septal Defects, Atrial/diagnostic imaging , Humans , Male , Middle Aged , Multivariate Analysis , Prevalence , Spain/epidemiology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...