Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Crit Care ; 18(1): R25, 2014 Feb 05.
Article in English | MEDLINE | ID: mdl-24499533

ABSTRACT

INTRODUCTION: Calibrated arterial pulse contour analysis has become an established method for the continuous monitoring of cardiac output (PCCO). However, data on its validity in hemodynamically instable patients beyond the setting of cardiac surgery are scarce. We performed the present study to assess the validity and precision of PCCO-measurements using the PiCCO™-device compared to transpulmonary thermodilution derived cardiac output (TPCO) as the reference technique in neurosurgical patients requiring high-dose vasopressor-therapy. METHODS: A total of 20 patients (16 females and 4 males) were included in this prospective observational clinical trial. All of them suffered from subarachnoid hemorrhage (Hunt&Hess grade I-V) due to rupture of a cerebral arterial aneurysm and underwent high-dose vasopressor therapy for the prevention/treatment of delayed cerebral ischemia (DCI). Simultaneous CO measurements by bolus TPCO and PCCO were obtained at baseline as well as 2 h, 6 h, 12 h, 24 h, 48 h and 72 h after inclusion. RESULTS: PCCO- and TPCO-measurements were obtained at baseline as well as 2 h, 6 h, 12 h, 24 h, 48 h and 72 h after inclusion. Patients received vasoactive support with (mean ± standard deviation, SD) 0.57 ± 0.49 µg · kg-1 · min-1 norepinephrine resulting in a mean arterial pressure of 103 ± 13 mmHg and a systemic vascular resistance of 943 ± 248 dyn · s · cm-5. 136 CO-data pairs were analyzed. TPCO ranged from 5.2 to 14.3 l · min-1 (mean ± SD 8.5 ± 2.0 l · min-1) and PCCO ranged from 5.0 to 14.4 l · min-1 (mean ± SD 8.6 ± 2.0 l · min-1). Bias and limits of agreement (1.96 SD of the bias) were -0.03 ± 0.82 l · min-1 and 1.62 l · min-1, resulting in an overall percentage error of 18.8%. The precision of PCCO-measurements was 17.8%. Insufficient trending ability was indicated by concordance rates of 74% (exclusion zone of 15% (1.29 l · min-1)) and 67% (without exclusion zone), as well as by polar plot analysis. CONCLUSIONS: In neurosurgical patients requiring extensive vasoactive support, CO values obtained by calibrated PCCO showed clinically and statistically acceptable agreement with TPCO-measurements, but the results from concordance and polar plot analysis indicate an unreliable trending ability.


Subject(s)
Cardiac Output/drug effects , Clinical Trials as Topic , Norepinephrine/therapeutic use , Subarachnoid Hemorrhage/drug therapy , Adult , Algorithms , Calibration , Female , Humans , Male , Middle Aged , Monitoring, Physiologic/methods , Neurosurgical Procedures , Norepinephrine/pharmacology , Prospective Studies , Subarachnoid Hemorrhage/physiopathology , Thermodilution/methods , Vascular Resistance , Vasoconstrictor Agents/pharmacology , Vasoconstrictor Agents/therapeutic use
2.
Anesth Analg ; 102(2): 352-62, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16428521

ABSTRACT

The use of miniaturized cardiopulmonary bypass (CPB) circuits and avoidance of cardioplegic arrest are attempts to reduce the inflammatory response to cardiac surgery. We studied the effects of beating heart surgery (BHS) with assistance of simplified bypass systems (SBS) on global hemodynamics, myocardial function and the inflammatory response to CPB. We hypothesized that the use of SBS was associated with less hemodynamic instability after CPB resulting from attenuation of the inflammatory response when compared with surgery performed with a conventional CPB (cCPB) circuit. Forty-five patients undergoing coronary artery bypass grafting were prospectively studied. Fifteen patients were randomized to the use of a cCPB circuit, cold crystalloid cardioplegia, and moderate hypothermia. Two groups of 15 patients underwent BHS during normothermia with assistance of two different SBS consisting of only blood pump and oxygenator. Hemodynamic variables were assessed with transpulmonary thermodilution and transesophageal echocardiography. Plasma levels of proinflammatory and antiinflammatory mediators were measured perioperatively. After CPB, variables of global hemodynamics and systolic ventricular function did not differ among groups. Left ventricular diastolic function was impaired after CPB equally in all groups (P < 0.01 versus pre-CPB). At the end of surgery, there was more need for vasopressor (norepinephrine) support in both SBS groups than in the cCPB group (P < 0.01). After CPB, the release of interleukin (IL)-6 did not differ significantly among groups, whereas plasma levels of IL-10 were higher in the cCPB group (P < 0.01 versus SBS). The extent of myocardial necrosis (Troponin T) was comparable in all groups. We conclude that in our study, miniaturizing bypass systems and avoidance of cardioplegic arrest were not effective in improving hemodynamic performance and in attenuating the proinflammatory immune response after CPB.


Subject(s)
Cardiopulmonary Bypass/instrumentation , Hemodynamics , Inflammation Mediators/blood , Anesthesia , Coronary Artery Bypass , Extracorporeal Circulation , Humans , Hypothermia, Induced , Middle Aged , Miniaturization , Monitoring, Intraoperative , Potassium Compounds
SELECTION OF CITATIONS
SEARCH DETAIL
...