Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
J Mech Behav Biomed Mater ; 153: 106507, 2024 May.
Article in English | MEDLINE | ID: mdl-38503082

ABSTRACT

Polyolefins exhibit robust mechanical and chemical properties and can be applied in the medical field, e.g. for the manufacturing of dentures. Despite their wide range of applications, they are rarely used in extrusion-based printing due to their warpage tendency. The aim of this study was to investigate and reduce the warpage of polyolefins compared to commonly used filaments after additive manufacturing (AM) and sterilization using finite element simulation. Three types of filaments were investigated: a medical-grade polypropylene (PP), a glass-fiber reinforced polypropylene (PP-GF), and a biocopolyester (BE) filament, and they were compared to an acrylic resin (AR) for material jetting. Square specimens, standardized samples prone to warpage, and denture bases (n = 10 of each group), as clinically relevant and anatomically shaped reference, were digitized after AM and steam sterilization (134 °C). To determine warpage, the volume underneath the square specimens was calculated, while the deviations of the denture bases from the printing file were measured using root mean square (RMS) values. To reduce the warpage of the PP denture base, a simulation of the printing file based on thermomechanical calculations was performed. Statistical analysis was conducted using the Kruskal-Wallis test, followed by Dunn's test for multiple comparisons. The results showed that PP exhibited the greatest warpage of the square specimens after AM, while PP-GF, BE, and AR showed minimal warpage before sterilization. However, warpage increased for PP-GF, BE and AR during sterilization, whereas PP remained more stable. After AM, denture bases made of PP showed the highest warpage. Through simulation-based optimization, warpage of the PP denture base was successfully reduced by 25%. In contrast to the reference materials, PP demonstrated greater dimensional stability during sterilization, making it a potential alternative for medical applications. Nevertheless, reducing warpage during the cooling process after AM remains necessary, and simulation-based optimization holds promise in addressing this issue.


Subject(s)
Polypropylenes , Steam , Polyenes , Acrylic Resins/chemistry , Sterilization
2.
Cancers (Basel) ; 16(4)2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38398080

ABSTRACT

Stimulated Raman Histology (SRH) employs the stimulated Raman scattering (SRS) of photons at biomolecules in tissue samples to generate histological images. Subsequent pathological analysis allows for an intraoperative evaluation without the need for sectioning and staining. The objective of this study was to investigate a deep learning-based classification of oral squamous cell carcinoma (OSCC) and the sub-classification of non-malignant tissue types, as well as to compare the performances of the classifier between SRS and SRH images. Raman shifts were measured at wavenumbers k1 = 2845 cm-1 and k2 = 2930 cm-1. SRS images were transformed into SRH images resembling traditional H&E-stained frozen sections. The annotation of 6 tissue types was performed on images obtained from 80 tissue samples from eight OSCC patients. A VGG19-based convolutional neural network was then trained on 64 SRS images (and corresponding SRH images) and tested on 16. A balanced accuracy of 0.90 (0.87 for SRH images) and F1-scores of 0.91 (0.91 for SRH) for stroma, 0.98 (0.96 for SRH) for adipose tissue, 0.90 (0.87 for SRH) for squamous epithelium, 0.92 (0.76 for SRH) for muscle, 0.87 (0.90 for SRH) for glandular tissue, and 0.88 (0.87 for SRH) for tumor were achieved. The results of this study demonstrate the suitability of deep learning for the intraoperative identification of tissue types directly on SRS and SRH images.

3.
Clin Oral Investig ; 27(8): 4705-4713, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37349642

ABSTRACT

OBJECTIVES: To investigate whether in patients undergoing surgery for oral squamous cell carcinoma, stimulated Raman histology (SRH), in comparison with H&E-stained frozen sections, can provide accurate diagnoses regarding neoplastic tissue and sub-classification of non-neoplastic tissues. MATERIALS AND METHODS: SRH, a technology based on Raman scattering, was applied to generate digital histopathologic images of 80 tissue samples obtained from 8 oral squamous cell carcinoma (OSCC) patients. Conventional H&E-stained frozen sections were then obtained from all 80 samples. All images/sections (SRH and H&E) were analyzed for squamous cell carcinoma, normal mucosa, connective tissue, muscle tissue, adipose tissue, salivary gland tissue, lymphatic tissue, and inflammatory cells. Agreement between SRH and H&E was evaluated by calculating Cohen's kappa. Accuracy of SRH compared to H&E was quantified by calculating sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) as well as area under the receiver operating characteristic curve (AUC). RESULTS: Thirty-six of 80 samples were classified as OSCC by H&E-based diagnosis. Regarding the differentiation between neoplastic and non-neoplastic tissue, high agreement between H&E and SRH (kappa: 0.880) and high accuracy of SRH (sensitivity: 100%; specificity: 90.91%; PPV: 90.00%, NPV: 100%; AUC: 0.954) were demonstrated. For sub-classification of non-neoplastic tissues, SRH performance was dependent on the type of tissue, with high agreement and accuracy for normal mucosa, muscle tissue, and salivary glands. CONCLUSION: SRH provides high accuracy in discriminating neoplastic and non-neoplastic tissues. Regarding sub-classification of non-neoplastic tissues in OSCC patients, accuracy varies depending on the type of tissue examined. CLINICAL RELEVANCE: This study demonstrates the potential of SRH for intraoperative imaging of fresh, unprocessed tissue specimens from OSCC patients without the need for sectioning or staining.


Subject(s)
Carcinoma, Squamous Cell , Head and Neck Neoplasms , Mouth Neoplasms , Humans , Squamous Cell Carcinoma of Head and Neck , Carcinoma, Squamous Cell/pathology , Mouth Neoplasms/pathology , Predictive Value of Tests
4.
Head Neck ; 44(12): 2810-2819, 2022 12.
Article in English | MEDLINE | ID: mdl-36114764

ABSTRACT

BACKGROUND: This study evaluated the accuracy of computer-assisted surgery (CAS)-driven DCIA (deep circumflex iliac artery) flap mandibular reconstruction by traditional morphometric methods and geometric morphometric methods (GMM). METHODS: Reconstruction accuracy was evaluated by measuring distances and angles between bilateral anatomical landmarks. Additionally, the average length of displacements vectors between landmarks was computed to evaluate factors assumed to influence reconstruction accuracy. Principal component analysis (PCA) was applied to unveil main modes of dislocation. RESULTS: High reconstruction accuracy could be demonstrated for a sample consisting of 26 patients. The effect of the number of segments and length of defect on reconstruction accuracy were close to the commonly used significance threshold (p = 0.062/0.060). PCA demonstrated displacement to result mainly from sagittal and transversal shifts. CONCLUSIONS: CAS is a viable approach to achieve high accuracy in mandibular reconstruction and GMM can facilitate the evaluation of factors influencing reconstruction accuracy and unveil main modes of dislocation in this context.


Subject(s)
Free Tissue Flaps , Mandibular Reconstruction , Plastic Surgery Procedures , Surgery, Computer-Assisted , Humans , Mandibular Reconstruction/methods , Iliac Artery/surgery , Surgical Flaps/blood supply , Computers , Plastic Surgery Procedures/methods , Free Tissue Flaps/surgery
5.
J Clin Med ; 11(13)2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35807112

ABSTRACT

BACKGROUND: Bimaxillary orthognathic surgery bears the risk of severe postoperative airway complications. There are no clear recommendations for immediate postoperative follow-up and monitoring. OBJECTIVE: to identify potential risk factors for prolonged mechanical ventilation and delayed extubation in patients undergoing bimaxillary orthognathic surgery. METHODS: The data of all consecutive patients undergoing bimaxillary surgery between May 2012 and October 2019 were analyzed in a single-center retrospective cohort study. The clinical data were evaluated regarding baseline characteristics and potential factors linked with delayed extubation. RESULTS: A total of 195 patients were included; 54.9% were female, and the median age was 23 years (IQR 5). The median body mass index was 23.1 (IQR 8). Nine patients (4.6%) were of American Society of Anesthesiologists Physical Status Classification System III or higher. The median duration of mechanical ventilation in the intensive care unit was 280 min (IQR, 526 min). Multivariable analysis revealed that premedication with benzodiazepines (odds ratio (OR) 2.60, 95% confidence interval (0.99; 6.81)), the male sex (OR 2.43, 95% confidence interval (1.10; 5.36)), and the duration of surgery (OR 1.54, 95% confidence interval (1.07; 2.23)) were associated with prolonged mechanical ventilation. By contrast, total intravenous anesthesia was associated with shorter ventilation time (OR 0.19, 95% confidence interval (0.09; 0.43)). CONCLUSION: premedication with benzodiazepines, the male sex, and the duration of surgery might be considered to be independent risk factors for delayed extubation in patients undergoing bimaxillary surgery.

6.
Plast Reconstr Surg Glob Open ; 9(10): e3836, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34616639

ABSTRACT

Microvascular anastomosis has become a standard surgical technique for reconstruction because of increasing possibilities, indications, and clinical success regarding the survival of the flaps. However, the main dreaded complications exist in thrombosis. Leaving surgical complications aside, systemic problems like disorder of the coagulation-fibrinolysis system are a significant cause of graft loss usually being unrecognized. Reports exist describing a hypercoagulable state with clotting activation and inhibition of fibrinolysis after trauma and delayed surgery considering the secondary homeostasis. In this clinical case, a patient had a large soft tissue defect at the temporal side of the head after severe trauma. After some days of primary stabilization, reconstruction using a free microvascular latissimus dorsi flap was performed. Multiple revisions of the arterial and venous branches had to be performed intraoperatively due to insufficient flap perfusion. After 24 hours, definitive flap loss occurred due to multiple thrombosis in the arterial and venous branches. Postoperative comprehensive coagulation analysis revealed a distinct activation of primary hemostasis with massively increased von Willebrand factor parameters and factor VIII activity as well as acetylsalicylic acid resistance contributing to thrombotic occlusion. In severely injured patients, comprehensive preoperative determination of the coagulation status (especially those of the primary hemostasis) is indispensable before performing free flap reconstruction surgeries to reduce the risk of microvascular flap loss.

7.
Sci Rep ; 11(1): 19347, 2021 09 29.
Article in English | MEDLINE | ID: mdl-34588584

ABSTRACT

The ongoing COVID-19 pandemic has revealed alarming shortages of personal protective equipment for frontline healthcare professionals and the general public. Therefore, a 3D-printable mask frame was developed, and its air seal performance was evaluated and compared. Personalized masks (PM) based on individual face scans (n = 8) and a statistically shaped mask (SSM) based on a standardized facial soft tissue shape computed from 190 face scans were designed. Subsequently, the masks were additively manufactured, and in a second step, the PM and SSM were compared to surgical masks (SM) and FFP2 masks (FFP2) in terms of air seal performance. 3D-printed face models allowed for air leakage evaluation by measuring the pressure inside the mask in sealed and unsealed conditions during a breathing simulation. The PM demonstrated the lowest leak flow (p < 0.01) of inspired or expired unfiltered air of approximately 10.4 ± 16.4%, whereas the SM showed the highest (p < 0.01) leakage with 84.9 ± 7.7%. The FFP2 and SSM had similar values of 34.9 ± 18.5% leakage (p > 0.68). The developed framework allows for the time- and resource-efficient, on-demand, and in-house production of masks. For the best seal performance, an individually personalized mask design might be recommended.


Subject(s)
COVID-19 , Masks , Personal Protective Equipment , Biometry , Equipment Design , Health Personnel , Humans , Printing, Three-Dimensional , Public Health
8.
Int J Prosthodont ; 29(3): 277-83, 2016.
Article in English | MEDLINE | ID: mdl-27148990

ABSTRACT

PURPOSE: The digitization of scanbodies on dental implants is required to use computer-aided design/computer-assisted manufacture processes for implant prosthetics. Little is known about the accuracy of scanbody digitization with intraoral scanners and dental lab scanners. This study aimed to examine the precision of different intraoral digital impression systems as well as a dental lab scanner using commercially available implant scanbodies. MATERIALS AND METHODS: Two study models with a different number and distribution of dental implant scanbodies were produced from conventional implant impressions. The study models were scanned using three different intraoral scanners (iTero, Cadent; Trios, 3Shape; and True Definition, 3M ESPE) and a dental lab scanner (D250, 3Shape). For each study model, 10 scans were performed per scanner to produce repeated measurements for the calculation of precision. The distance and angulation between the respective scanbodies were measured. The results of each scanning system were compared using analysis of variance, and post hoc Tukey test was conducted for a pairwise comparison of scanning devices. RESULTS: The precision values of the scanbodies varied according to the distance between the scanbodies and the scanning device. A distance of a single tooth space and a jaw-traversing distance between scanbodies produced significantly different results for distance and angle measurements between the scanning systems (P < .05). CONCLUSION: The precision of intraoral scanners and the dental lab scanner was significantly different. The precision of intraoral scanners decreased with an increasing distance between the scanbodies, whereas the precision of the dental lab scanner was independent of the distance between the scanbodies.


Subject(s)
Computer-Aided Design/statistics & numerical data , Dental Impression Technique/statistics & numerical data , Image Processing, Computer-Assisted/statistics & numerical data , Computer-Aided Design/instrumentation , Dental Implants , Dimensional Measurement Accuracy , Humans , Image Processing, Computer-Assisted/instrumentation , Jaw, Edentulous, Partially/pathology , Materials Testing , Models, Dental
9.
J Craniomaxillofac Surg ; 43(8): 1319-24, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26190694

ABSTRACT

BACKGROUND: Despite oversized latissimus dorsi free flap reconstruction in the head and neck area, esthetic and functional problems continue to exist due to the well-known occurrence of transplant shrinkage. The purpose of this study was to acquire an estimation of the volume and time of the shrinkage process. MATERIALS AND METHODS: The assessment of volume loss was performed using a 3D evaluation of two postoperative CT scans. A retrospective review was conducted on all latissimus dorsi free flap reconstructions performed between 2004 and 2013. Inclusion criteria for the assessment were: resection of an oral carcinoma and microsurgical defect coverage with latissimus dorsi free flap; a first postoperative CT (CT1) performed between 3 weeks and a maximum of 3 months after reconstruction surgery; and an additional CT scan (CT2) performed at least one year postoperatively. The exclusion criterion was surgical intervention in the local area between the acquisition of CT1 and CT2. The effect of adjuvant radiation therapy was considered. Volume determination of the transplant was carried out in CT1 and CT2 by manual segmentation of the graft. RESULTS: Fifteen patients were recruited. 3D evaluation showed an average volume loss of 34.4%. In the consideration of postoperative radiotherapy the volume reduction was 39.2% in patients with radiotherapy and 31.3% in patients without radiotherapy. CONCLUSION: The reconstruction flap volume required for overcorrection of the surgical defect was investigated. This study indicates that a volume loss of more than 30% could be expected one or more years after latissimus dorsi free flap reconstruction. Clinical trial number DRKS00007534.


Subject(s)
Autografts/transplantation , Free Tissue Flaps/transplantation , Imaging, Three-Dimensional/methods , Mouth Neoplasms/surgery , Plastic Surgery Procedures/methods , Superficial Back Muscles/transplantation , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Autografts/diagnostic imaging , Autografts/radiation effects , Carcinoma, Squamous Cell/radiotherapy , Carcinoma, Squamous Cell/surgery , Female , Follow-Up Studies , Humans , Male , Microsurgery/methods , Middle Aged , Mouth Neoplasms/radiotherapy , Organ Size , Postoperative Complications/diagnostic imaging , Radiotherapy, Adjuvant/methods , Retrospective Studies , Superficial Back Muscles/diagnostic imaging , Superficial Back Muscles/radiation effects , Time Factors , Young Adult
10.
J Craniomaxillofac Surg ; 43(6): 758-62, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25964005

ABSTRACT

BACKGROUND: A prerequisite of irradiation after advanced head and neck tumour resection is the accurate localization of the tumour resection margin. The purpose of the following study is to evaluate the use of surgical clips placed in the tumour resection margins for use as radiographic markers to facilitate focussed adjuvant radiation therapy. MATERIALS: To evaluate whether the clips remain predictive for the resection margin, we analysed the deviation of each clip in two postoperative CT scans on different days. Bone registration points were used to fuse the two CT scans in the region of the primary tumour and the distances between corresponding clips were measured. RESULTS: The tumour resection margins were labelled with an average of 18 titanium clips. In total 282 clips were evaluated. Metric analysis of clip deviation between the two postoperative CT scans found a mean distance of 4.5 mm ± 2.5 mm with a range of 0.5-11.8 mm. No significant statistical relationship of the clip differences as a function of time, the method of reconstruction or administered radiotherapy could be demonstrated. CONCLUSION: Placement of surgical clips in the cavity walls after complete tumour resection provides an easy and inexpensive approach for defining resection margins and allows for increased accuracy of adjuvant treatment. Clinical trial number DRKS00007534.


Subject(s)
Fiducial Markers , Head and Neck Neoplasms/surgery , Margins of Excision , Surgical Instruments , Tomography, X-Ray Computed/methods , Biocompatible Materials/chemistry , Follow-Up Studies , Free Tissue Flaps/transplantation , Head and Neck Neoplasms/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Neck Dissection/methods , Prospective Studies , Radiotherapy, Adjuvant , Plastic Surgery Procedures/methods , Reproducibility of Results , Titanium/chemistry , Wound Closure Techniques
11.
Radiother Oncol ; 116(1): 82-6, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25981050

ABSTRACT

BACKGROUND: Accurate tumour bed localisation is a key requirement for adjuvant radiotherapy. A new procedure is described for head and neck cancer treatment that improves tumour bed localisation using titanium clips. MATERIALS AND METHODS: Following complete local excision of the primary tumour, the tumour bed was marked with titanium clips. Preoperative gross target volume (GTV) and postoperative tumour bed were examined and the distances between the centres of gravity were evaluated. RESULTS: 49 patients with squamous cell carcinoma of the oral cavity were prospectively enrolled in this study. All patients underwent tumour resection, neck lymph node dissection and defect reconstruction in one stage. During surgery, 7-49 clips were placed in the resection cavity. Surgical clip insertion was successful in 88% (n=43). Clip identification and tumour bed delineation was successful in all 43 patients. The overall distance between the centres of gravity of the preoperative tumour extension to the tumour bed was 0.9cm. A significant relationship between the preoperative tumour extension and the postoperative tumour bed volume could be demonstrated. CONCLUSION: We demonstrate a precise delineation of the former tumour cavity. Improvements in tumour bed delineation allow an increase of accuracy for adjuvant treatment.


Subject(s)
Carcinoma, Squamous Cell/radiotherapy , Head and Neck Neoplasms/radiotherapy , Adult , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/surgery , Female , Head and Neck Neoplasms/surgery , Humans , Male , Middle Aged , Radiotherapy, Adjuvant , Surgical Instruments , Tumor Burden
12.
J Craniomaxillofac Surg ; 43(4): 567-73, 2015 May.
Article in English | MEDLINE | ID: mdl-25841307

ABSTRACT

Accurate localization of tumor resection borders is crucial for adjuvant radiotherapy. An improvement to adjuvant radiotherapy with the reduction of radiation doses to free flap reconstruction by virtual navigation procedures and titanium clips was evaluated. Thirty-three patients with oral cancer were prospectively included in the study. Following complete local excision of the primary tumor, resection borders were marked virtually using a navigation pointer and with titanium ligature clips. Postoperative delineation of tumor resection borders was examined. In five patients with microvascular free flap reconstruction a reduction of the radiation dose to the free flap reconstruction was achieved. The tumor resection borders in 30 patients were marked with titanium ligature clips. Surgical clip insertion was successful in 91%. We demonstrate a significant relationship between the reconstruction volume and the part of the target volume which will receive a reduced radiation dose. A cumulative dose of 60 Gy was administered to the target volume and a significant reduction of the administered radiation dose to the center of the flap could be demonstrated. We demonstrate an accurate delineation of the tumor resection margins. These improvements in tumor resection margin delineation allow for increased accuracy in adjuvant treatment and a reduction of radiation dose to the vascular free flap reconstruction.


Subject(s)
Carcinoma, Squamous Cell/surgery , Free Tissue Flaps/transplantation , Mouth Neoplasms/surgery , Patient Care Planning , Plastic Surgery Procedures/methods , Radiotherapy Dosage , Radiotherapy, Adjuvant/methods , Adult , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/radiotherapy , Chemoradiotherapy, Adjuvant/methods , Feasibility Studies , Female , Humans , Ligation/instrumentation , Male , Microsurgery/instrumentation , Microsurgery/methods , Middle Aged , Mouth Neoplasms/radiotherapy , Neck Dissection/methods , Pilot Projects , Prospective Studies , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods , Surgery, Computer-Assisted/methods , Surgical Instruments , Titanium/chemistry , Tomography, X-Ray Computed/methods , User-Computer Interface
13.
Am J Orthod Dentofacial Orthop ; 144(3): 471-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23992820

ABSTRACT

INTRODUCTION: Digital impression devices are used alternatively to conventional impression techniques and materials. The aims of this study were to evaluate the precision of digital intraoral scanning under clinical conditions (iTero; Align Technologies, San Jose, Calif) and to compare it with the precision of extraoral digitization. METHODS: One patient received 10 full-arch intraoral scans with the iTero and conventional impressions with a polyether impression material (Impregum Penta; 3M ESPE, Seefeld, Germany). Stone cast models manufactured from the impressions were digitized 10 times with an extraoral scanner (D250; 3Shape, Copenhagen, Denmark) and 10 times with the iTero. Virtual models provided by each method were roughly aligned, and the model edges were trimmed with cutting planes to create common borders (Rapidform XOR; Inus Technologies, Seoul, Korea). A second model alignment was then performed along the closest distances of the surfaces (Artec Studio software; Artec Group, Luxembourg, Luxembourg). To assess precision, deviations between corresponding models were compared. Repeated intraoral scanning was evaluated in group 1, repeated extraoral model scanning with the iTero was assessed in group 2, and repeated model scanning with the D250 was assessed in group 3. Deviations between models were measured and expressed as maximums, means, medians, and root mean square errors for quantitative analysis. Color-coded displays of the deviations allowed qualitative visualization of the deviations. RESULTS: The greatest deviations and therefore the lowest precision were in group 1, with mean deviations of 50 µm, median deviations of 37 µm, and root mean square errors of 73 µm. Group 2 showed a higher precision, with mean deviations of 25 µm, median deviations of 18 µm, and root mean square errors of 51 µm. Scanning with the D250 had the highest precision, with mean deviations of 10 µm, median deviations of 5 µm, and root mean square errors of 20 µm. Intraoral and extraoral scanning with the iTero resulted in deviations at the facial surfaces of the anterior teeth and the buccal molar surfaces. CONCLUSIONS: Scanning with the iTero is less accurate than scanning with the D250. Intraoral scanning with the iTero is less accurate than model scanning with the iTero, suggesting that the intraoral conditions (saliva, limited spacing) contribute to the inaccuracy of a scan. For treatment planning and manufacturing of tooth-supported appliances, virtual models created with the iTero can be used. An extended scanning protocol could improve the scanning results in some regions.


Subject(s)
Computer Simulation , Dental Impression Technique , Image Processing, Computer-Assisted/instrumentation , Imaging, Three-Dimensional , Tomography Scanners, X-Ray Computed , Computer-Aided Design , Dental Impression Materials , Dental Impression Technique/instrumentation , Dimensional Measurement Accuracy , Humans , Imaging, Three-Dimensional/instrumentation , Models, Dental , Orthodontic Appliance Design/methods , Statistics, Nonparametric
14.
Otolaryngol Head Neck Surg ; 149(1): 60-6, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23482478

ABSTRACT

OBJECTIVE: The most accurate orbital reconstructions result from an anatomic repair of the premorbid orbital architecture. Many different techniques and materials have been used; unfortunately, there is currently no optimal method. This study compares the use of preformed vs intraoperative bending of titanium mesh for orbital reconstruction in 2-wall orbital fractures. STUDY DESIGN: Cadaver-based study. SETTING: University hospital. SUBJECTS AND METHODS: Preinjury computed tomography scans were obtained in 15 cadaveric heads (30 orbits). Stereolithographic (STL) models were fabricated for 5 of the specimens (10 orbits). Two wall fractures (lamina papyracea and floor) were then generated in all orbits. Surgical reconstruction was performed in all orbits using 1 of 3 techniques (10 orbits each): (1) patient-specific implant molded from the preinjury STL model, (2) titanium mesh sheet bent freehand, and (3) preformed titanium mesh. Each technique was evaluated for orbital volume correction, contour accuracy, ease of use, and cost. RESULTS: No difference in volume restoration was found between the 3 techniques. Patient-specific implants had the greatest contour accuracy, poor ease of use, and highest cost. Freehand bending implants had the poorest contour accuracy, acceptable ease of use, and lowest cost. Preformed mesh implants had intermediate contour accuracy, excellent ease of use, and low cost. CONCLUSION: All 3 techniques provide equivalent orbital volume correction. However, preformed mesh implants have many advantages based on contour accuracy, ease of use, and relative cost.


Subject(s)
Fracture Fixation, Internal/instrumentation , Orbital Fractures/surgery , Plastic Surgery Procedures/instrumentation , Surgical Mesh , Titanium , Bone Plates , Cadaver , Humans , Materials Testing , Orbital Fractures/pathology , Prosthesis Design
15.
J Oral Maxillofac Surg ; 69(11): 2763-70, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21703745

ABSTRACT

PURPOSE: The aim of this study was to investigate bone mass using different cone-beam computed tomographies (CBCTs) combined with image analysis and to determine whether bone quantity or quality was detected. MATERIALS AND METHODS: Different measurements recorded on mandible bones of pigs in the retromolar region were evaluated on ProMax 3D (Planmeca Oy, Finland) and the ILUMA™CT (IMTEC™ Imaging, Ardmore, OK) to calculate a calibration curve. The spatial relationships of pig mandible halves relative to adjacent defined anatomical structures were assessed by means of 3D visualization software. In addition to the screenshot, their bone quality was evaluated in accordance with the Lenkholm and Zarb classification. RESULTS: The CBCT calibration curves based on the measurements taken from the ProMax and ILUMA CT showed linear correlation. Huge Hounsfield units intervals were found between the 2 CBCTs and there was no correlation with the computed tomography. Exact information on the micromorphology of the bone cylinders was not available. A subjective correlation according to Lenkholm and Zarb showed overlapping in all groups. CONCLUSIONS: CBCT is a good choice for analyzing bone mass. However, it does not provide any information on bone quality. To obtain information on the microarchitecture of the spongiosa, it is necessary to use a computed tomography with finite element analysis.


Subject(s)
Cone-Beam Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Mandible/diagnostic imaging , Animals , Bone Density/physiology , Calibration , Cone-Beam Computed Tomography/instrumentation , Image Processing, Computer-Assisted/instrumentation , Imaging, Three-Dimensional/methods , Radiographic Image Interpretation, Computer-Assisted , Radiology Information Systems , Software , Swine
16.
J Craniomaxillofac Surg ; 39(6): 393-400, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21094050

ABSTRACT

PURPOSE: The purpose of this study was to evaluate and analyze statistical shapes of the outer mandible contour of Caucasian and Chinese people, offering data for the production of preformed mandible reconstruction plates. METHODS: A CT-database of 925 Caucasians (male: n=463, female: n=462) and 960 Chinese (male: n=469, female: n=491) including scans of unaffected mandibles were used and imported into the 3D modeling software Voxim (IVS-Solutions, Chemnitz, Germany). Anatomical landmarks (n=22 points for both sides) were set using the 3D view along the outer contour of the mandible at the area where reconstruction plates are commonly located. We used morphometric methods for statistical shape analysis. RESULTS: We found statistical relevant differences between populations including a distinct discrimination given by the landmarks at the mandible. After generating a metric model this shape information which separated the populations appeared to be of no clinical relevance. The metric size information given by ramus length however provided a profound base for the production of standard reconstruction plates. CONCLUSION: Clustering by ramus length into three sizes and calculating means of these size-clusters seem to be a good solution for constructing preformed reconstruction plates that will fit a vast majority.


Subject(s)
Bone Plates , Computer Simulation , Mandible/anatomy & histology , Plastic Surgery Procedures/instrumentation , Analysis of Variance , Anatomic Landmarks , Asian People , Cephalometry , Cluster Analysis , Equipment Design , Female , Humans , Male , Principal Component Analysis , Prosthesis Design , White People
17.
Laryngoscope ; 120(5): 881-8, 2010 May.
Article in English | MEDLINE | ID: mdl-20422680

ABSTRACT

OBJECTIVES/HYPOTHESIS: Various invasive and noninvasive registration methods have been established in the past for intraoperative navigation. The present study compared the registration and navigation accuracy of three different registration modalities in anatomical locations of special interest for ear, nose, and throat surgery. STUDY DESIGN: Prospective experimental phantom study. METHODS: Four skull models were individually fabricated with a three-dimensional printer based on the patient's computed tomography data sets and fitted with an individual customized silicone skin. Three different registration modalities were examined: 1) invasive marker (IM), 2) oral splint (OS), and 3) laser scan (L). Accuracy measurements were assessed by targeting 26 titanium screws placed over the skull. The overall accuracy and the target registration error for eight selected anatomical locations were measured. RESULTS: Mean accuracy was 0.67 + or - 0.1 mm (quadratic mean + or - standard deviation) for IM, 0.98 + or - 0.16 mm for OS, and 1.3 + or - 0.12 mm for L. The greatest differences in accuracy were found on the mastoid with best accuracy for IM (0.59 + or - 0.2 mm; P < .05 vs. OS and L), followed by OS (1.23 + or - 0.41 mm; P < .05 vs. L), and L (1.88 + or - 0.45 mm). In contrast, only small differences in accuracy were detected in the anterior skull base between the registration modalities (IM 0.75 + or - 0.21 mm, OS 0.71 + or - 0.27 mm, L 0.93 + or - 0.34 mm). CONCLUSIONS: L and OS meet accuracy requirements in the midface and anterior skull base. OS is superior to L with navigation accuracies comparable to marker registration. However, neither method meets the high precision requirements for lateral skull base surgery. Laryngoscope, 2010.


Subject(s)
Neuronavigation/methods , Otorhinolaryngologic Diseases/surgery , Computer-Aided Design , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Minimally Invasive Surgical Procedures/methods , Models, Anatomic , Neuronavigation/instrumentation , Otorhinolaryngologic Diseases/diagnostic imaging , Skull Base/surgery , Tomography, X-Ray Computed
18.
Lasers Med Sci ; 25(1): 67-71, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19277821

ABSTRACT

A new concept was developed based on the experience gained in dental rehabilitation with implantation in the oral maxillofacial region. Despite the use of cooling systems, mechanically rotating instruments may damage the surrounding tissue due to the frictional heat generated. An alternative approach for bone removal is laser application. A preoperative plan was prepared. Laser ablation was performed in accordance with the data set on bovine bone using a navigation system. This new concept allows precise bone removal and adjustment of the laser power according to the preoperative plan. The power of the laser automatically decreases as it approaches the border of the planned cavity or important anatomical structures. The advantage of this approach is precise and safe bone removal without damaging the bone by frictional heat.


Subject(s)
Bone and Bones/surgery , Laser Therapy/methods , Surgery, Computer-Assisted/methods , Animals , Cattle , Dental Implantation/methods , Humans , In Vitro Techniques , Laser Therapy/instrumentation , Laser Therapy/statistics & numerical data , Models, Animal , Software , Surgery, Computer-Assisted/instrumentation , Surgery, Computer-Assisted/statistics & numerical data
20.
Quintessence Int ; 40(5): 351-4, 2009 May.
Article in English | MEDLINE | ID: mdl-19582237

ABSTRACT

This clinical case describes mandibular osteomyelitis in a healthy 31-year-old man as a severe complication following third molar removal. Recurrent abscess formations were treated with intensive therapy involving antibiotics, surgical debridement of the affected region, and hyperbaric oxygen. In the follow-up, despite microbiologic study to determine the indicated treatment approach, a severe osteomyelitis was present, clinically and radiographically. Finally, a partial resection of the mandible, including exarticulation, was indicated to manage this severe complication.


Subject(s)
Mandibular Diseases/etiology , Osteomyelitis/etiology , Tooth Extraction/adverse effects , Adult , Humans , Male , Molar, Third/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...