Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Indian Heart J ; 66(6): 691-5, 2014.
Article in English | MEDLINE | ID: mdl-25634407

ABSTRACT

OBJECTIVES: This study aims to assess the safety and efficacy of a biodegradable polymer-coated Rapamycin-Eluting Stent (Excel) used in conjunction with six-month dual antiplatelet therapy in daily practice. BACKGROUND: The polymeric material of cardiac stents has been reported to adversely affect the safety profile of the drug-eluting stents and is also suspected to cause serious long-term complications. It has been proposed that the biodegradable polymer coatings may reduce such late-stage adverse effects. METHODS: This is a prospective, multi-center registry of 654 patients from across 9 cardiology centers in India, who were enrolled and exclusively treated with Excel stents between February 2008 and May 2010. The recommended antiplatelet regimen included clopidogrel and aspirin for 6 months period, followed by lifelong aspirin therapy. RESULTS: The study population included 46.94% diabetics, 24.31% smokers, 48.93% hypertensives and 14.98% hyperlipidemics. The cumulative rates of major adverse cardiac events were 0.153% at discharge and 1.38% at 12 months. The mean percentage of stenosis was 88.24 ± 9.17% No events occurred between 6 and 12 months. CONCLUSIONS: This multi-center registry study on "real world, all comers" has, thus, showed that EXCEL™ stent which is PLA-coated biodegradable Rapamycin-Eluting Stent exhibited high efficacy and safety profile in treatment of patients undergoing PCI as evidenced by significantly lower rates of MACE and no case of stent thrombosis. There was no event even after DAPT was discontinued after 6 months.

2.
Indian Heart J ; 65(5): 593-9, 2013.
Article in English | MEDLINE | ID: mdl-24206883

ABSTRACT

OBJECTIVE: The e-BioMatrix is a post marketing multicenter registry with an objective to evaluate the 2 year clinical safety and efficacy outcomes in patients treated with BioMatrix™ - Biolimus A9™ (BA9™) drug eluting stents (DES). BACKGROUND: Drug-eluting stents still have late-stage disadvantages that might be attributable to the permanent polymer. BioMatrix a new generation DES containing anti-proliferative drug Biolimus A9™ incorporating a biodegradable abluminal coating that leaves a polymer-free stent after drug release enhancing strut coverage while preventing neointimal hyperplasia. METHODS: This interim analysis consists of a total of 1189 patients with 1418 lesions treated with BioMatrix stent who entered this multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, and 12 months with an extended follow-up of 2 years. Recommended antiplatelet regimen included clopidogrel and aspirin for 12 months. RESULTS: The mean age was 57.6 ± 10.9 years, 81.8% were males, comorbidity index was 1.20 ± 1.33, 68% presented with acute coronary syndrome, 49% had hypertension and 40.8% had diabetes mellitus. One-year clinical follow-up was completed in 987 patients at the time of interim analysis. The incidence of MACE is 0.45 for 1544 person-year follow-up. There were only 03 cases of ST (01 late ST) reported during this time. CONCLUSION: This registry demonstrates excellent one-year clinical safety and efficacy of BioMatrix stents. The 1-year result shows that BioMatrix stent may be a suitable alternative as compared to contemporary DESs which are currently available in the market for simple as well complex disease.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Coronary Stenosis/therapy , Drug-Eluting Stents , Registries , Sirolimus/analogs & derivatives , Acute Coronary Syndrome/epidemiology , Age Factors , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Female , Follow-Up Studies , Humans , India , Male , Middle Aged , Product Surveillance, Postmarketing , Prosthesis Failure , Radiography , Risk Assessment , Sex Factors , Sirolimus/pharmacology , Survival Rate , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...