Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Clin Ter ; 171(5): e385-e392, 2020.
Article in English | MEDLINE | ID: mdl-32901779

ABSTRACT

BACKGROUND: Marginal bone loss (MBL) represents an important indicator of peri-implant health and the measure of its level is considered a determining factor in the evaluation of the quality of survival. Aim of this study is to compare radiographic changes in the fractal and mesial/distal vertical dimensions of peri-implant trabecular bone of dental implants with a laser-ablated micron-scale modication (LAM) of collar surface after a 5-year follow-up period. MATERIALS AND METHODS: Thirty-four implants with LAM of collar surface (test group = TG) and 31 implants without LAM of collar surface (control group = CG) were placed in 45 non-smoking, periodontally healthy patients. Fractal and vertical dimensions of peri-implant trabecular bone were measured by comparing radiographs taken immediately after prosthesis delivery with those taken 3 years and 5 years after functional loading. RESULT: At the end of the 5-year follow-up, the MBL in the TG was 0.87±0.21 and 0.75±0.25 mm at the mesial and distal aspects, respectively, while a MBL of 2.05±0.25 mm at the mesial aspect and 2.01±0.34 mm at the distal site was recorded in the CG. A statistically significant difference was noted. In the TG the mean fractal dimension before loading was 1.4213±0.0525. It increased significantly to 1.4329±0.0479 at 3 years after loading and remained almost stable at 5 years after loading (1.4327±0.0291). In the CG the mean fractal dimension before loading was 1.4119±0.0414. It increased significantly to 1.4282±0.0324 at 3 years after loading and decreased significantly to 1.4111±0.0624 at 5 years after loading. At the end of the follow-up, differences between both study groups were statistically significant. CONCLUSION: The increased fractal dimension and the reduced MBL around TG implants after 5 years of functional loading indicates a positive effect of a laser-ablated micron-scale modication of collar surface on peri-implant trabecular bone remodeling.


Subject(s)
Cancellous Bone/surgery , Dental Implants , Laser Therapy , Adult , Cancellous Bone/diagnostic imaging , Female , Follow-Up Studies , Fractals , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Surface Properties
2.
Clin Ter ; 170(4): e258-e261, 2019.
Article in English | MEDLINE | ID: mdl-31304512

ABSTRACT

AIMS: This study aims to estimate the microbial presence on the surface of different brand new NiTi endodontic instruments for clinical use. MATERIAL AND METHODS: Eleven different types of NiTi rotary endodontic instruments, obtained from their fresh opened original packages, were assigned to three different groups, according to packaging type and sterilization and tested for bacterial contamination. Isolated bacteria were identified by using standard microbiological methods and then counted. Differences observed in groups were analyzed statistically by using the one-way analysis of variance (ANOVA) for dependent samples and the Tukey HSD post hoc test. RESULTS: Statistical differences were found between instruments delivered in plastic boxes which bacterial count resulted higher than those obtained from instruments delivered in blisters (p<0.01). CONCLUSIONS: Some brand new endodontic instruments showed degrees of bacterial contamination that both quantitatively and qualitatively deserve to be considered in clinical procedures.


Subject(s)
Bacteria/isolation & purification , Dental Equipment/microbiology , Endodontics/instrumentation , Equipment Contamination , Nickel , Titanium , Humans , Sterilization
3.
J Proteomics ; 204: 103396, 2019 07 30.
Article in English | MEDLINE | ID: mdl-31150779

ABSTRACT

Water temperature is an important environmental parameter influencing the distribution and the health of fishes and it plays a central role in ectothermic animals. The aim of this study is to determine the effects of environmental temperature on the brain proteome and the behavioural responses in zebrafish, a widely used animal model for environmental "omics" studies. Adult specimens of wild-type zebrafish were kept at 18 °C, 34 °C and 26 °C (control) for 21 days. Proteomic data revealed that several proteins involved in cytoskeletal organization, mitochondrial regulation and energy metabolism are differently regulated at the extreme temperatures. In particular, the expression of proteins associated to synapses and neurotransmitter release is down-regulated at 18 °C and 34 °C. In both thermal conditions, fish exhibited a reduced interest for the novel environment and an impairment of cognitive abilities during Y-Maze behavioural tests. The observed pathways of protein expression are possibly associated to functional alterations of the synaptic transmission that may result in cognitive functions impairment at central nervous system level as those revealed by behavioural tests. This study indicates that temperature variations can elicit biochemical changes that may affect fish health and behaviour. This combined approach provides insights into mechanisms supporting thermal acclimation and plasticity in fishes. SIGNIFICANCE: Environmental temperature variation may impact on all levels of biological life. Understanding the impact of thermal variation on the nervous system and animal behaviour is of primary importance since the results obtained can be applied from the ecological to the biomedical fields.


Subject(s)
Behavior, Animal , Brain/metabolism , Cognition , Gene Expression Regulation , Hot Temperature , Zebrafish Proteins/biosynthesis , Zebrafish/metabolism , Animals , Maze Learning , Proteomics
4.
Clin Ter ; 169(3): e96-e101, 2018.
Article in English | MEDLINE | ID: mdl-29938739

ABSTRACT

OBJECTIVES: Aim of the present study was twofold. First, to evaluate in vitro, the performance of two different NiTi rotary instruments in one molar case; then, to evaluate their resistance to cyclic fatigue, compared to new ones. MATERIAL AND METHODS: 25 ProTaper Next (PTN) nickel-titanium (NiTi) instruments (Maillefer-Dentsply, Baillagues, CH) for each of the following two sizes: X1 (17.04 ) and X2 (25.06) were randomly divided into two groups. The first group (n = 10) immediately under- went to a cyclic fatigue test. The second group (n = 15) was initially used to prepare 15 extracted molar teeth and then subjected to a cyclic fatigue test. Same was done for 25 Horizen (HZ) instruments (Kerr Endodontics, Orange, Ca) for each of the following two sizes: 20.04 and 25.06. Instruments were rotated in curved artificial canal until fracture occurred and times to fracture were recorded. All data were collected and statistically analyzed using a variance test (confidence interval CI = 95%). RESULTS: HZ reached working length more rapidly than PTN, and with less deformations. For the fatigue tests, all the new instruments were significantly more resistant than the used ones. The HZ instru- ments were significantly more resistant in all sizes than PTN, both when new and used instruments were tested. CONCLUSIONS: Since in previous studies ProTaper Next demonstra- ted a better resistance to cyclic fatigue than most of nickel-titanium instruments, Horizen's performance put them in a high rank amongst the most resistant nickel-titanium rotary instruments.


Subject(s)
Dental Alloys/chemistry , Materials Testing , Nickel/chemistry , Titanium/chemistry , Equipment Design , Equipment Failure , Humans , Root Canal Preparation , Rotation
5.
Clin Ter ; 168(1): e23-e27, 2017.
Article in English | MEDLINE | ID: mdl-28240758

ABSTRACT

OBJECTIVES: Previous studies showed that motor motions play an important role in determining apical extrusion of debris. Therefore a new clinical motion (MIMERACI) has been proposed. The basic idea is to progress slowly (1mm advancement), and after each 1mm, to remove the instrument from the canal, clean flutes and irrigate. The aim of the study was to prove whether the clinical use of MIMERACI technique would influence or not postoperative pain. MATERIALS AND METHODS: 100 teeth requesting endodontic treatment were selected for the study and divided into two similar groups based on anatomy, pre-operative symptoms and vitality, presence or absence of periapical lesion. All teeth were shaped, cleaned and obturated by the same operator, using the same NiTi instruments. The only difference between the two groups was the instrumentation technique: tradional (group A) vs MIMERACI (group B). Assessment of postoperative pain was performed 3 days after treatment. Presence, absence and degree of pain were recorded with a visual analogue scale (VAS), validated in previous studies. Collected data statistically analyzed using one-way ANOVA post hoc Tukey test. RESULTS: For VAS pain scores MIMERACI technique showed significantly better results than group A (p=0,031). Overall, both incidence and intensity of symptoms were significantly lower. Flare ups occurred in 3 patients, but none treated with the MIMERACI Technique. CONCLUSIONS: Since extruded debris can elicit more postoperative pain, results obtained by using MIMERACI technique are probably due to many factors: better mechanical removal and less production of debris and more efficient irrigation during instrumentation.


Subject(s)
Pain, Postoperative/epidemiology , Root Canal Preparation/methods , Adolescent , Adult , Aged , Humans , Incidence , Middle Aged , Nickel , Titanium , Tooth Apex , Young Adult
6.
Ergonomics ; 42(6): 880-8, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10340028

ABSTRACT

A first application of a new measurement technique to detect vibration transmitted to the human body in working conditions is presented. The technique is based on the use of a laser scanning vibrometer. It was previously developed, analysed and tested using laboratory test benches with electrodynamical exciters, and comparisons with traditional measurement techniques based on accelerometers were made. First, results of tests performed using a real machine generating vibration are illustrated. The machine used is a pedestrian-controlled tractor working in a fixed position. Reference measurements by using the accelerometer have been simultaneously performed while scanning the hand surface by the laser-based measurement system. Results achieved by means of both measurement techniques have been processed, analysed, compared and used to calculate transmissibility maps of the hands of three subjects.


Subject(s)
Agriculture/instrumentation , Lasers , Occupational Exposure/analysis , Signal Processing, Computer-Assisted , Vibration , Acceleration , Agricultural Workers' Diseases/etiology , Humans , Occupational Exposure/adverse effects , Reproducibility of Results , Vibration/adverse effects
7.
Article in English | MEDLINE | ID: mdl-18290166

ABSTRACT

The status of magnetostatic wave (MSW) straight-edge resonators (SERs) and their applications in tunable oscillator circuits are reviewed. The resonators are based on magnetostatic waves propagating in high-Q cavities fabricated in thin ferrimagnetic yttrium iron garnet (YIG) films. The resonance frequency of these resonators can be tuned using a bias magnetic field. The theory of operation and design criteria for the straight-edge resonators are described with emphasis on the effect of the resonator parameters on the tuning range, power handling, and phase noise performance. The use of the SER as the frequency-selective element in oscillator circuits is reported. Examples of tunable oscillators are included.

9.
Boll Soc Ital Biol Sper ; 56(4): 380-4, 1980 Feb 29.
Article in Italian | MEDLINE | ID: mdl-7248098

ABSTRACT

Mechanical test was applied to several carotid walls air-dried under different degree of deformation along the circumferential direction. The stress-strain curves show an increase of the elastic modulus as a function of the deformation. X-ray diffraction studies were applied to determine the degree of collagen orientation in the deformed samples. The carotid wall, in agreement with the "composite materials theory", shows that the collagen is the most responsible factor of the mechanical properties of the tissue.


Subject(s)
Carotid Arteries/physiology , Collagen/physiology , Animals , Cattle , Elasticity
SELECTION OF CITATIONS
SEARCH DETAIL
...