Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Neuroradiol J ; 37(3): 336-341, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38490750

ABSTRACT

OBJECTIVES: Glioses appear as hypodense lesions in non-contrast CT examinations of the head. Photon counting CT (PCCT) enables the calculation of virtual monoenergetic images (VMI). The aim of this study is to investigate in which VMI hypodense gliotic lesions can be delineated best. MATERIALS AND METHODS: 35 patients with an MRI-confirmed gliotic lesion and a non-contrast PCCT of the head were retrospectively included. All available VMI from 40 keV to 190 keV were calculated. In a quantitative analysis, conventional image quality parameters were calculated, in particular the contrast-to-noise ratio (CNR) of the hypodense lesion compared to the white matter. In a qualitative analysis, selected VMI were rated by experienced radiologists. RESULTS: The absolute maximum of CNR was 8.12 ± 5.64 in the VMI 134 keV, in post hoc testing, there were significant differences in comparison to VMI with keV ≤110 and keV ≥180 (corrected p < .05). In the qualitative analysis, there were only very slight differences in the rating of the VMI with 66 keV, 80 keV, 100 keV, and 134 keV with overall low agreement between the readers. CONCLUSIONS: The quantitative superiority of VMI 134 keV for the delineation of hypodense gliotic lesions did not translate into a superiority in the qualitative analysis. Therefore, it remains uncertain if the reconstruction of a high keV VMIs for the detection of hypodense gliotic lesions is useful in everyday clinical practice. However, more studies, are necessary to further assess this issue.


Subject(s)
Tomography, X-Ray Computed , Humans , Female , Male , Retrospective Studies , Middle Aged , Tomography, X-Ray Computed/methods , Aged , Adult , Aged, 80 and over , Magnetic Resonance Imaging/methods , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/pathology , Photons
2.
Heliyon ; 10(6): e27636, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38509988

ABSTRACT

Rationale and objectives: Coronary computed tomography angiography (CCTA) is becoming increasingly important for the diagnostic workup of coronary artery disease, nevertheless, imaging of in-stent stenosis remains challenging. For the first time, spectral imaging in Ultra High Resolution (UHR) is now possible in clinically available photon counting CT. The aim of this work is to determine the optimal virtual monoenergetic image (VMI) for imaging in-stent stenoses in cardiac stents. Materials and methods: 6 stents with inserted hypodense stenoses were scanned in an established phantom in UHR mode. Images were reconstructed with 3 different kernels for spectral data (Qr56, Qr64, Qr72) with varying levels of sharpness. Based on region of interest (ROI) measurements image quality parameters including contrast-to-noise ratio (CNR) were analyzed for all available VMI (40 keV-190 keV). Finally, based on quantitative results and VMI used in clinical routine, a set of VMI was included in a qualitative reading. Results: CNR showed significant variations across different keV levels (p < 0.001). Due to reduced noise there was a focal maximum in the VMI around 65 keV. The peak values were observed for kernel Qr56 at 116 keV with 19.47 ± 8.67, for kernel Qr64 at 114 keV with 13.56 ± 6.58, and for kernel Qr72 at 106 keV with 12.19 ± 3.25. However, in the qualitative evaluation the VMI with lower keV (55 keV) performed best. Conclusions: Based on these experimental results, a photon counting CCTA in UHR with stents should be reconstructed with the Qr72 kernel for the assessment of in-stent stenoses, and a VMI 55 keV should be computed for the evaluation.

3.
Radiology ; 310(3): e230545, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38530174

ABSTRACT

Background Coronary artery calcium scoring (CACS) for coronary artery disease requires true noncontrast (TNC) CT alongside contrast-enhanced coronary CT angiography (CCTA). Photon-counting CT provides an algorithm (PureCalcium) for reconstructing virtual noncontrast images from CCTA specifically for CACS. Purpose To assess CACS differences based on PureCalcium images derived from contrast-enhanced photon-counting CCTA compared with TNC images and evaluate the impact of these differences on the clinically relevant classification of patients into plaque burden groups. Materials and Methods Photon-counting CCTA images acquired between August 2022 and May 2023 were retrospectively identified. Agatston scores were derived from both TNC and PureCalcium images and tested for differences with use of the Wilcoxon signed-rank test. The agreement was assessed with use of equivalence tests, Bland-Altman analysis, and intraclass correlation coefficient. Plaque burden groups were established based on Agatston scores, and agreement was evaluated using weighted Cohen kappa. The dose-length product was analyzed. Results Among 170 patients (mean age, 63 years ± 13 [SD]; 92 male), 111 had Agatston scores higher than 0. Median Agatston scores did not differ between TNC and PureCalcium images (4.8 [IQR, 0-84.4; range, 0.0-2151.8] vs 2.7 [IQR, 0-90.7; range, 0.0-2377.1]; P = .99), with strong correlation (intraclass correlation coefficient, 0.98 [95% CI: 0.97, 0.99]). The equivalence test was inconclusive, with a 95% CI of 0.90, 1.19. Bland-Altman analysis showed wide repeatability limits, indicating low agreement between the two scores. With use of the PureCalcium algorithm, 125 of 170 patients (74%) were correctly classified into plaque burden groups (excellent agreement, κ = 0.88). Patients without plaque burden were misclassified at higher than normal rates (P < .001). TNC image acquisition contributed a mean of 19.7% ± 8.8 of the radiation dose of the entire examination. Conclusion PureCalcium images show potential to replace TNC images for measuring Agatston scores, thereby reducing radiation dose in CCTA. There was strong correlation in calcium scores between TNC and PureCalcium, but limited agreement. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Sakuma in this issue.


Subject(s)
Calcium , Computed Tomography Angiography , Humans , Male , Middle Aged , Coronary Vessels/diagnostic imaging , Retrospective Studies , Coronary Angiography , Tomography, X-Ray Computed
4.
Neuroradiology ; 66(5): 729-736, 2024 May.
Article in English | MEDLINE | ID: mdl-38411902

ABSTRACT

PURPOSE: To determine the optimal virtual monoenergetic image (VMI) for detecting and assessing intracranial hemorrhage in unenhanced photon counting CT of the head based on the evaluation of quantitative and qualitative image quality parameters. METHODS: Sixty-three patients with acute intracranial hemorrhage and unenhanced CT of the head were retrospectively included. In these patients, 35 intraparenchymal, 39 intraventricular, 30 subarachnoidal, and 43 subdural hemorrhages were selected. VMIs were reconstructed using all available monoenergetic reconstruction levels (40-190 keV). Multiple regions of interest measurements were used for evaluation of the overall image quality, and signal, noise, signal-to-noise-ratio (SNR), and contrast-to-noise-ratio (CNR) of intracranial hemorrhage. Based on the results of the quantitative analysis, specific VMIs were rated by five radiologists on a 5-point Likert scale. RESULTS: Signal, noise, SNR, and CNR differed significantly between different VMIs (p < 0.001). Maximum CNR for intracranial hemorrhage was reached in VMI with keV levels > 120 keV (intraparenchymal 143 keV, intraventricular 164 keV, subarachnoidal 124 keV, and subdural hemorrhage 133 keV). In reading, no relevant superiority in the detection of hemorrhage could be demonstrated using VMIs above 66 keV. CONCLUSION: For the detection of hemorrhage in unenhanced CT of the head, the quantitative analysis of the present study on photon counting CT is generally consistent with the findings from dual-energy CT, suggesting keV levels just above 120 keV and higher depending on the location of the hemorrhage. However, on the basis of the qualitative analyses, no reliable statement can yet be made as to whether an additional VMI with higher keV is truly beneficial in everyday clinical practice.


Subject(s)
Radiographic Image Interpretation, Computer-Assisted , Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Intracranial Hemorrhages/diagnostic imaging , Signal-To-Noise Ratio
5.
Acad Radiol ; 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38418345

ABSTRACT

RATIONALE AND OBJECTIVES: Common computed tomography (CT) investigation plays a limited role in characterizing and assessing the response of rectal cancer (RC) to neoadjuvant radiochemotherapy (NARC). Photon counting computed tomography (PCCT) improves the imaging quality and can provide multiparametric spectral image information including iodine concentration (IC). Our purpose was to analyze associations between IC and histopathology in RC and to evaluate the role of IC in response prediction to NARC. MATERIALS AND METHODS: Overall, 41 patients were included into the study, 14 women and 27 men, mean age, 65.5 years. PCCT in a portal venous phase of the abdomen was performed. In every case, a polygonal region of interest (ROI) was manually drawn on iodine maps. Normalized IC (NIC) was also calculated. Tumor stage, grade, lymphovascular invasion, circumferential resection margin, and tumor markers were analyzed. Tumor regression grade (absence/presence of tumor cells) after NARC was analyzed. NIC values in groups were compared to Mann-Whitney-U tests. Sensitivity, specificity, and area under the curve values were calculated. Intraclass correlation coefficient (ICC) was calculated. RESULTS: ICC was 0.93, 95%CI= (0.88; 0.96). Tumors with lymphovascular invasion showed higher NIC values in comparison to those without (p = 0.04). Tumors with response grade 2-4 showed higher pretreatment NIC values in comparison to lesions with response grade 0-1 (p = 0.01). A NIC value of 0.36 and higher can predict response grade 2-4 (sensitivity, 73.9%; specificity, 91.7%; area under the curve, 0.85). CONCLUSION: NIC values showed an excellent interreader agreement in RC. NIC can predict treatment response to NARC.

6.
Eur J Radiol ; 173: 111374, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38422607

ABSTRACT

PURPOSE OF THE STUDY: The aim of the study was to identify differences in the tumor conspicuity of pancreatic adenocarcinomas in different monoenergetic or polyenergetic reconstructions and contrast phases in photon-counting CT (PCCT). MATERIAL AND METHODS: 34 patients were retrospectively enrolled in this study. Quantitative image analysis was performed with region of interest (ROI) measurements in different monoenergetic levels ranging from 40 up to 70 keV (5-point steps) and polyenergetic series. Tumor-parenchyma attenuation differences and contrast-to-noise-ratio (CNR) were calculated. A qualitative image analysis was accomplished by 4 radiologists using a 5-point Likert scale (1 = "not recognizable" up to 5 = "easy recognizable"). Differences between groups were evaluated for statistical significance using the Friedman test and in case of significant differences pair-wise post-hoc testing with Bonferroni correction was applied. RESULTS: Tumor-parenchyma attenuation difference was significantly different between the different image reconstructions for both arterial- and portal-venous-phase-images (p < 0.001). Tumor-parenchyma attenuation difference was significantly higher on arterial-phase-images at mono40keV compared to polyenergetic images (p < 0.001) and mono55keV images or higher (p < 0.001). For portal-venous-phase-images tumor-parenchyma attenuation difference was significantly higher on mono40keV images compared to polyenergetic images (p < 0.001) and mono50keV images (p = 0.03) or higher (p < 0.001). The same trend was seen for CNR. Tumor conspicuity was rated best on mono40keV images with 4.3 ± 0.9 for arterial-phase-images and 4.3 ± 1.1 for portal-venous-phase-images. In contrast, overall image quality was rated best on polyenergetic-images with 4.8 ± 0.5 for arterial-phase-images and 4.7 ± 0.6 for portal-venous-phase-images. CONCLUSION: Low keV virtual monoenergetic images significantly improve the tumor conspicuity of pancreatic adenocarcinomas in PCCT based on quantitative and qualitative results. On the other hand, readers prefer polyenergetic images for overall image quality.


Subject(s)
Adenocarcinoma , Pancreatic Neoplasms , Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Tomography, X-Ray Computed/methods , Pancreatic Neoplasms/diagnostic imaging , Adenocarcinoma/diagnostic imaging , Signal-To-Noise Ratio , Radiographic Image Interpretation, Computer-Assisted
7.
Clin Neuroradiol ; 34(1): 75-83, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37589739

ABSTRACT

PURPOSE: Nonenhanced computed tomography (CT) of the head is among the most commonly performed CT examinations. The spectral information acquired by photon counting CT (PCCT) allows generation of virtual monoenergetic images (VMI). At the same time, image noise can be reduced using quantum iterative reconstruction (QIR). In this study, the image quality of VMI was evaluated depending on the keV level and the QIR level. Furthermore, the influence of the cranial calvaria was investigated to determine the optimal reconstruction for clinical application. METHODS: A total of 51 PCCT (NAEOTOM Alpha, Siemens Healthineers, Erlangen, Germany) of the head were retrospectively analyzed. In a quantitative analysis, gray and white matter ROIs were evaluated in different brain areas at all available keV levels and QIR levels with respect to signal, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). The distance to the cranial calvaria of the ROIs was included in the analysis. This was followed by a qualitative reading by five radiologists including experienced neuroradiologists. RESULTS: In most ROIs, signal and noise varied significantly between keV levels (p < 0.0001). The CNR had a focal maximum at 66 keV and an absolute maximum at higher keV, slightly differently located depending on ROI and QIR level. With increasing QIR level, a significant reduction in noise was achieved (p < 0.0001) except just beneath the cranial calvaria. The cranial calvaria had a strong effect on the signal (p < 0.0001) but not on gray and white matter noise. In the qualitative reading, the 60 keV VMI was rated best. CONCLUSION: In nonenhanced PCCT of the head the selected keV level of the VMI and the QIR level have a crucial influence on image quality in VMI. The 60 keV and 66 keV VMI with high QIR level provided optimal subjective and objective image quality for clinical use. The cranial calvaria has a significant influence on the visualization of the adjacent brain matter; currently, this substantially limits the use of low keV VMIs (< 60 keV).


Subject(s)
Radiography, Dual-Energy Scanned Projection , Humans , Retrospective Studies , Radiography, Dual-Energy Scanned Projection/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Skull/diagnostic imaging
8.
Acad Radiol ; 31(2): 686-692, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37393176

ABSTRACT

RATIONALE AND OBJECTIVES: To evaluate the potential to reduce the amount of iodinated contrast media (CM) for computer tomographic pulmonary angiography (CTPA) with a novel photon-counting-detector CT (PCCT). MATERIALS AND METHODS: Overall, 105 patients referred for CTPA were retrospectively included in this study. CTPA was performed using bolus tracking and high-pitch dual-source scanning (FLASH mode) on a novel PCCT (Naeotom Alpha, Siemens Healthineers). CM (Accupaque 300, GE Healthcare) dose was lowered stepwise following the introduction of the new CT scanner. Thus, patients could be divided into 3 groups as follows: group 1, n = 29, 35 ml of CM; group 2, n = 62, 45 ml of CM and group 3, n = 14, 60 ml of CM. Four readers independently assessed the image quality (Likert-scale 1-5) and adequate assessment of the segmental pulmonary arteries. Additionally, the pulmonary arterial contrast opacification was measured. RESULTS: The subjective image quality was rated highest in group 1 with 4.6 compared to 4.5 (group 2) and 4.1 (group 3) with a significant difference between groups 1 and 3 (p < 0.001) and between groups 2 and 3 (p = 0.003). In all groups, almost all segmental pulmonary arteries could be assessed adequately without significant differences (18.5 vs. 18.7 vs. 18.4). Mean attenuation in the pulmonary trunk did not differ significantly between groups 321 ± 92 HU versus 345 ± 93 HU versus 347 ± 88 HU (p = 0.69). CONCLUSION: Significant CM dose reduction is possible without a reduction in image quality. PCCT enables diagnostic CTPA with 35 ml of CM.


Subject(s)
Contrast Media , Pulmonary Embolism , Humans , Pulmonary Embolism/diagnostic imaging , Retrospective Studies , Pulmonary Artery/diagnostic imaging , Tomography, X-Ray Computed/methods , Angiography/methods , Computed Tomography Angiography/methods , Radiation Dosage
9.
Medicine (Baltimore) ; 102(47): e36069, 2023 Nov 24.
Article in English | MEDLINE | ID: mdl-38013308

ABSTRACT

The purpose of the present study was to evaluate the subjectively perceived patient comfort during magnetic resonance imaging (MRI) examinations and to assess potential differences between a recently introduced low field MRI scanner and a standard MRI scanner. Among other characteristics, the low field MRI scanner differs from the standard MRI scanner by offering more space (wider bore size of 80 centimeter diameter) and producing less noise, which may influence the patient comfort. In total, 177 patients were surveyed after MRI scans with either the low field MRI scanner (n = 91, MAGNETOM Free.Max, Siemens Healthineers) or the standard MRI scanner (n = 86, MAGNETOM Avanto Fit, Siemens Healthineers). Patients rated different aspects of comfort on a 5 point Likert scale: (a) claustrophobia, (b) comfort of the scanner table, (c) noise level and (d) vertigo during the scanning procedure. In terms of claustrophobia and comfort of the scanner table, patients rated both MRI scanners similar (e.g., mean ratings for claustrophobia: standard MRI scanner = 4.63 ± 1.04, low field MRI scanner = 4.65 ± 1.02). However, when asked for a comparison, patients did favor the more spacious low field MRI scanner. In terms of noise level, the low field MRI scanner was rated significantly better (mean ratings: standard MRI scanner = 3.72 ± 1.46 [median 4 = "rather not unpleasant"], low field MRI scanner = 4.26 ± 1.22 [median 5 = "not unpleasant at all"]). Patients did not perceive any significant difference in terms of vertigo between both MRI scanners. The newly developed low field MRI scanner offers constructional differences compared to standard MRI scanners that are perceived positively by patients. Worth highlighting is the significantly lower noise level and the innovative bore diameter of 80 centimeter, which offers more space to the patients.


Subject(s)
Patient Comfort , Phobic Disorders , Humans , Magnetic Resonance Imaging/adverse effects , Magnetic Resonance Imaging/methods , Vertigo/diagnostic imaging , Perception
10.
J Stroke Cerebrovasc Dis ; 32(12): 107421, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37826941

ABSTRACT

BACKGROUND: Sarcopenia is proposed as a novel imaging biomarker in several acute conditions regarding outcome and mortality. The aim of the present study was to investigate the prognostic role of the masseter muscles in patients with acute ischemic stroke (AIS). METHODS: Overall, 189 patients with AIS that received mechanical thrombectomy were retrospectively enrolled in this study. Outcome and overall survival after 90 days were analyzed. Transversal surface area and density of the masseter muscles were measured. The diagnostic performance for the estimation of a) favorable modified ranking scale 90 days (mRS 90) outcome and b) death at 90 days was calculated using univariate and multivariate logistic regression analysis, followed by receiver operating characteristics and Odds ratios. RESULTS: The masseter muscle area provided a significant difference between patients who survived and those who died and between patients who had a favorable outcome (mRS 90 < 3) and those who did not. The cutoff for a favorable mRS 90 was found to be 435.8 mm2 for men and 338.8 mm2 for women, the cutoff for the prediction of death 421.3 mm2 for men and 326.6 mm2 for women. Masseter muscle area was the third strongest predictor in both categories after patient age and NIHSS. CONCLUSIONS: Masseter muscle area is an independent predictor of mortality in patients with AIS.


Subject(s)
Brain Ischemia , Ischemic Stroke , Sarcopenia , Stroke , Male , Humans , Female , Stroke/diagnostic imaging , Stroke/therapy , Brain Ischemia/diagnostic imaging , Brain Ischemia/therapy , Treatment Outcome , Retrospective Studies , Sarcopenia/diagnostic imaging , Risk Factors , Thrombectomy/methods
11.
Psychogeriatrics ; 23(6): 963-972, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37673659

ABSTRACT

BACKGROUND: Distressing behavioural symptoms, particularly agitation and aggressiveness, remain a difficult problem in everyday clinical practice in the treatment of multimorbid patients with dementia. Clozapine may be an effective therapeutic alternative in this context. METHODS: In a retrospective study, patients who had a diagnosis of dementia and had been treated in a specialized geriatric psychiatry unit with clozapine between August 2018 and February 2022 were included, and medical records were systematically reviewed. The Clinical Global Impressions Scale was used to assess improvement, and the Pittsburgh Agitation Scale for symptom reduction. In addition, side effects and clinical features were documented in detail. RESULTS: A total of 31 patients (median age 82 years) were identified with a mean clozapine dose of 47.2 (SD 35.6) mg. A total of 13 patients tolerated clozapine very well, 10 showed tolerable side effects, and in 10 patients side effects were the reason for stopping clozapine. Behavioural symptoms improved significantly, as indicated by the assessment scores. CONCLUSIONS: In summary, clozapine was effective and well tolerated in 23 patients, suggesting that low-dose clozapine may help to alleviate the suffering of difficult-to-treat multimorbid patients with advanced dementia and their caregivers. However, particular attention should be paid to adverse drug reactions, especially in patients with cardiovascular and pulmonary impairment.


Subject(s)
Antipsychotic Agents , Clozapine , Dementia , Humans , Aged , Aged, 80 and over , Clozapine/therapeutic use , Antipsychotic Agents/therapeutic use , Retrospective Studies , Dementia/complications , Dementia/drug therapy , Dementia/chemically induced
12.
Eur J Radiol ; 167: 111031, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37591133

ABSTRACT

PURPOSE: Purpose of this study is to re-evaluate the accuracy and diagnostic reliability of virtual non-contrast (VNC) images acquired with the photon-counting computed tomography (PCCT) after an update of the CT scanner software. METHODS: Fifty-four patients were retrospectively enrolled. VNC images were reconstructed from true non-contrast (TNC) images (VNCn) and contrast-enhanced images in portal venous contrast phase (VNCv). Additionally, a liver-specific VNC (VNCl) was assessed. Quantitative image properties of VNC and TNC images were compared and consistency between VNC images was evaluated. Regions of interest were drawn in the liver, spleen, renal cortex, aorta, muscle and subcutaneous fat. RESULTS: Attenuation values on all VNC images differed significantly from TNC images in the liver, renal cortex, aorta and fat. A mean offset of <10HU between TNC and all VNC images was found in the liver, spleen and muscle. The comparison of TNC and VNCl images revealed an offset < 10HU in fat. Differences ≤ 10HU between TNC and VNCv and between TNC and VNCl were found in 68%, respectively in 75%. Differences ≤ 15HU were found in 79%, respectively in 92% of all measurements. Differences ≤ 10HU between TNC and VNCn were found in 79% and differences ≤ 15HU in 85%. CONCLUSION: Although there are statistically significant differences between HU values measured on TNC and VNC images in certain tissues, the minor offsets measured in liver and spleen suggest a good clinical applicability of VNCv and VNCl images. The significantly lower offset in subcutaneous fat on VNCl images suggests a superiority for measurements in adipose tissues.


Subject(s)
Liver , Tomography, X-Ray Computed , Humans , Retrospective Studies , Reproducibility of Results , Tomography, X-Ray Computed/methods , Liver/diagnostic imaging , Abdomen
13.
Eur J Radiol ; 166: 110983, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37480648

ABSTRACT

PURPOSE: Imaging stents and in-stent stenosis remains a challenge in coronary computed tomography angiography (CCTA). In comparison to conventional Computed Tomography, Photon Counting CT (PCCT) provides decisive clinical advantages, among other things by providing low dose ultra-high resolution imaging of coronary arteries. This work investigates the image quality in CCTA using clinically established kernels and those optimized for the imaging of cardiac stents in PCCT, both for in-vitro stent imaging in 400 µm standard resolution mode (SRM) and 200 µm Ultra High Resolution Mode (UHR). METHODS: Based on experimental scans, vascular reconstruction kernels (Bv56, Bv64, Bv72) were optimized. In an established phantom, 10 different coronary stents with 3 mm diameter were scanned in the first clinically available PCCT. Scans were reconstructed with clinically established and optimized kernels. Four readers measured visible stent lumen, performed ROI-based density measurements and rated image quality. RESULTS: Regarding the visible stent lumen, UHR is significantly superior to SRM (p < 0.001). In all levels, the optimized kernels are superior to the clinically established kernels (p < 0.001). One optimized kernel showed a significant reduction of noise compared to the clinically established kernels. Overall image quality is improved with optimized kernels. CONCLUSIONS: In a phantom study PCCT UHR with optimized kernels for stent imaging significantly improves the ability to assess the in-stent lumen of small cardiac stents. We recommend using UHR with an optimized sharp vascular reconstruction kernel (Bv72uo) for imaging of cardiac stent.


Subject(s)
Angiography , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Computed Tomography Angiography , Stents
14.
Eur Radiol ; 33(12): 9286-9295, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37436505

ABSTRACT

OBJECTIVES: To investigate photon-counting CT (PCCT)-derived virtual monoenergetic images (VMI) for artifact reduction in patients with unilateral total hip replacements (THR). METHODS: Forty-two patients with THR and portal-venous phase PCCT of the abdomen and pelvis were retrospectively included. For the quantitative analysis, region of interest (ROI)-based measurements of hypodense and hyperdense artifacts, as well as of artifact-impaired bone and the urinary bladder, were conducted, and corrected attenuation and image noise were calculated as the difference of attenuation and noise between artifact-impaired and normal tissue. Two radiologists qualitatively evaluated artifact extent, bone assessment, organ assessment, and iliac vessel assessment using 5-point Likert scales. RESULTS: VMI110keV yielded a significant reduction of hypo- and hyperdense artifacts compared to conventional polyenergetic images (CI) and the corrected attenuation closest to 0, indicating best possible artifact reduction (hypodense artifacts: CI: 237.8 ± 71.4 HU, VMI110keV: 8.5 ± 122.5 HU; p < 0.05; hyperdense artifacts: CI: 240.6 ± 40.8 HU vs. VMI110keV: 13.0 ± 110.4 HU; p < 0.05). VMI110keV concordantly provided best artifact reduction in the bone and bladder as well as the lowest corrected image noise. In the qualitative assessment, VMI110keV received the best ratings for artifact extent (CI: 2 (1-3), VMI110keV: 3 (2-4); p < 0.05) and bone assessment (CI: 3 (1-4), VMI110keV: 4 (2-5); p < 0.05), whereas organ and iliac vessel assessments were rated highest in CI and VMI70keV. CONCLUSIONS: PCCT-derived VMI effectively reduce artifacts from THR and thereby improve assessability of circumjacent bone tissue. VMI110keV yielded optimal artifact reduction without overcorrection, yet organ and vessel assessments at that energy level and higher were impaired by loss of contrast. CLINICAL RELEVANCE STATEMENT: PCCT-enabled artifact reduction is a feasible method for improving assessability of the pelvis in patients with total hip replacements at clinical routine imaging. KEY POINTS: • Photon-counting CT-derived virtual monoenergetic images at 110 keV yielded best reduction of hyper- and hypodense artifacts, whereas higher energy levels resulted in artifact overcorrection. • The qualitative artifact extent was reduced best in virtual monoenergetic images at 110 keV, facilitating an improved assessment of the circumjacent bone. • Despite significant artifact reduction, assessment of pelvic organs as well as vessels did not profit from energy levels higher than 70 keV, due to the decline in image contrast.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Artifacts , Retrospective Studies , Tomography, X-Ray Computed/methods , Bone and Bones , Radiographic Image Interpretation, Computer-Assisted/methods
15.
Sci Rep ; 13(1): 3680, 2023 03 05.
Article in English | MEDLINE | ID: mdl-36872333

ABSTRACT

The AI-Rad Companion Chest X-ray (AI-Rad, Siemens Healthineers) is an artificial-intelligence based application for the analysis of chest X-rays. The purpose of the present study is to evaluate the performance of the AI-Rad. In total, 499 radiographs were retrospectively included. Radiographs were independently evaluated by radiologists and the AI-Rad. Findings indicated by the AI-Rad and findings described in the written report (WR) were compared to the findings of a ground truth reading (consensus decision of two radiologists after assessing additional radiographs and CT scans). The AI-Rad can offer superior sensitivity for the detection of lung lesions (0.83 versus 0.52), consolidations (0.88 versus 0.78) and atelectasis (0.54 versus 0.43) compared to the WR. However, the superior sensitivity is accompanied by higher false-detection-rates. The sensitivity of the AI-Rad for the detection of pleural effusions is lower compared to the WR (0.74 versus 0.88). The negative-predictive-values (NPV) of the AI-Rad for the detection of all pre-defined findings are on a high level and comparable to the WR. The seemingly advantageous high sensitivity of the AI-Rad is partially offset by the disadvantage of a high false-detection-rate. At the current stage of development, therefore, the high NPVs may be the greatest benefit of the AI-Rad giving radiologists the possibility to re-insure their own negative search for pathologies and thus boosting their confidence in their reports.


Subject(s)
Artificial Intelligence , Tomography, X-Ray Computed , X-Rays , Retrospective Studies , Radiography
16.
Diagnostics (Basel) ; 13(3)2023 Jan 26.
Article in English | MEDLINE | ID: mdl-36766563

ABSTRACT

Background: This study evaluated the feasibility of reducing the radiation dose in abdominal imaging of urolithiasis with a clinical photon-counting CT (PCCT) by gradually lowering the image quality level (IQL) without compromising the image quality and diagnostic value. Methods: Ninety-eight PCCT examinations using either IQL70 (n = 31), IQL60 (n = 31) or IQL50 (n = 36) were retrospectively included. Parameters for the radiation dose and the quantitative image quality were analyzed. Qualitative image quality, presence of urolithiasis and diagnostic confidence were rated. Results: Lowering the IQL from 70 to 50 led to a significant decrease (22.8%) in the size-specific dose estimate (SSDE, IQL70 4.57 ± 0.84 mGy, IQL50 3.53 ± 0.70 mGy, p < 0.001). Simultaneously, lowering the IQL led to a minimal deterioration of the quantitative quality, e.g., image noise increased from 9.13 ± 1.99 (IQL70) to 9.91 ± 1.77 (IQL50, p = 0.248). Radiologists did not notice major changes in the image quality throughout the IQLs. Detection rates of urolithiasis (91.3-100%) did not differ markedly. Diagnostic confidence was high and not influenced by the IQL. Conclusions: Adjusting the PCCT scan protocol by lowering the IQL can significantly reduce the radiation dose without significant impairment of the image quality. The detection rate and diagnostic confidence are not impaired by using an ultra-low-dose PCCT scan protocol.

17.
Interv Neuroradiol ; : 15910199221129097, 2022 Sep 22.
Article in English | MEDLINE | ID: mdl-36147011

ABSTRACT

BACKGROUND: The Nimbus stent-retriever (NSR) was developed for mechanical thrombectomy of wall-adherent thrombi in cerebral arteries. It features a novel geometry with a proximal spiral section and a distal barrel section. The new device is designed to retrieve tough clots with a micro-clamping technique. In the first case series reporting on the NSR, we share our initial experience about the first 12 treated cases. METHODS: In total, 12 patients (5 men, 7 women; mean age 78 years) with occlusion of the internal carotid artery or the middle cerebral artery (M1 or M2 segment) were treated with the NSR, 11 after unsuccessful recanalization attempts with conventional stent-retrievers or aspiration thrombectomy. RESULTS: Retrieving maneuvers with the NSR recovered a thrombus in 7 patients (58%), of which 6 resulted in vessel recanalization mTICI ≥ 2b. Successful recanalization improved the mTICI score by a median of 3 points. In 5 of 7 cases, this required only one thrombectomy maneuver. In 5 cases, no improvement of recanalization could be achieved with the NSR (1-3 attempts). No NSR-related complications occurred in this case series. CONCLUSIONS: In our initial experience, the NSR appeared to be a safe and effective second-line stent-retriever after unsuccessful MT with conventional stent-retrievers or aspiration thrombectomy allowing for mTICI ≥ 2b rescue thrombectomy in ab 50% of cases. No NSR associated complications occurred in our case series.

19.
Tomography ; 8(4): 1666-1675, 2022 06 23.
Article in English | MEDLINE | ID: mdl-35894003

ABSTRACT

The purpose of this study was the evaluation of image quality and radiation dose parameters of the novel photon counting CT (PCCT, Naeotom Alpha, Siemens Healthineers) using low-dose scan protocols for the detection of urolithiasis. Standard CT scans were used as a reference (S40, Somatom Sensation 40, Siemens Healthineers). Sixty-three patients, who underwent CT scans between August and December 2021, were retrospectively enrolled. Thirty-one patients were examined with the PCCT and 32 patients were examined with the S40. Radiation dose parameters, as well as quantitative and qualitative image parameters, were analyzed. The presence of urolithiasis, image quality, and diagnostic certainty were rated on a 5-point-scale by 3 blinded readers. Both patient groups (PCCT and S40) did not differ significantly in terms of body mass index. Radiation dose was significantly lower for examinations with the PCCT compared to the S40 (2.4 ± 1.0 mSv vs. 3.4 ± 1.0 mSv; p < 0.001). The SNR was significantly better on images acquired with the PCCT (13.3 ± 3.3 vs. 8.2 ± 1.9; p < 0.001). The image quality of the PCCT was rated significantly better (4.3 ± 0.7 vs. 2.8 ± 0.6; p < 0.001). The detection rate of kidney or ureter calculi was excellent with both CT scanners (PCCT 97.8% and S40 99%, p = 0.611). In high contrast imaging, such as the depiction of stones of the kidney and the ureter, PCCT allows a significant reduction of radiation dose, while maintaining excellent diagnostic confidence and image quality. Given this image quality with our current protocol, further adjustments towards ultra-low-dose CT scans appear feasible.


Subject(s)
Tomography, X-Ray Computed , Urolithiasis , Humans , Radiation Dosage , Retrospective Studies , Tomography Scanners, X-Ray Computed , Tomography, X-Ray Computed/methods , Urolithiasis/diagnostic imaging
20.
Tomography ; 8(3): 1401-1412, 2022 05 23.
Article in English | MEDLINE | ID: mdl-35645399

ABSTRACT

BACKGROUND: The purpose of the present study is to evaluate the patient comfort during CT examinations with a modern CT scanner (Photon-Counting CT (PCCT)) and to compare the perceived patient comfort with a standard CT scanner. METHODS: A total of 157 patients participated in this study and completed a questionnaire on their subjective perceptions after their CT examination. The following aspects of comfort were rated on a 5-point Likert scale: (1) claustrophobia in general and during the examination, (2) the effort to lie down and to get up from the CT table, (3) the speed and comfort of the CT table, (4) the difficulty of holding the breath during the CT scan, and (5) the communication during the examination. RESULTS: Patients rated the modern CT scanner significantly better in terms of speed and comfort of the CT table and in terms of difficulty of holding their breath during the CT scan. The answers regarding the other aspects of comfort did not reveal significant differences. When asked for a comparison, patients who did perceive a difference between both scanners rated the modern CT scanner as more comfortable in all aspects of comfort. CONCLUSIONS: The survey did not reveal any major deficits in terms of comfort on the standard CT scanner. However, patients perceived the structural changes positively and appreciated the comfort of a modern CT scanner.


Subject(s)
Patient Comfort , Tomography, X-Ray Computed , Humans , Tomography Scanners, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...