Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Luminescence ; 2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38098178

ABSTRACT

An innovative, simple, accurate, sensitive, and eco-friendly synchronous fluorescence spectrofluorimetric method has been developed for the simultaneous analysis of montelukast sodium (MON) and fexofenadine hydrochloride (FEX). The method relies on measuring the relative synchronous fluorescence intensity of both drugs using Δλ of 60 nm in methanol at 405 nm for MON and 288 nm for FEX. The experimental parameters influencing the developed method were investigated and optimized. The method was linear over the ranges 0.1-2.0 and 2.0-20.0 µg/ml for MON and FEX, respectively. The limits of detection were 0.018 and 0.441 µg/ml, and the limits of quantitation were 0.055 and 1.336 µg/ml for MON and FEX, respectively. The developed method was applied successfully for the determination of the two drugs in their newly released fixed-dose combination prescribed for the treatment of allergic rhinitis. The mean per cent recoveries were found to be 100.680 ± 0.890 and 100.110 ± 0.940 for MON and FEX, respectively. Furthermore, the method was found to be eco-friendly green as was evaluated according to the Green Analytical Procedure Index tool guidelines and analytical eco-scale.

2.
J Sep Sci ; 43(16): 3197-3205, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32506818

ABSTRACT

A fast, green, sensitive, and accurate analytical method using high-performance liquid chromatography couple with fluorescence detection was established and validated for the simultaneous determination of amlodipine besylate and celecoxib in their recently approved fixed-dose combination tablets (1:20). Separation of the two drugs was achieved on C18 reversed-phase column (Thermo ODS Hypersil, 4.6 × 250 mm, particle size 5 µm) using acetonitrile:potassium phosphate buffer (50 mM; pH 5.5, 60:40 v/v) as a mobile phase at 40°C, which eluted at a rate of 1 mL/min. Detection was carried out with excitation and emission wavelengths of 360 and 446 nm for amlodipine and 265 and 359 nm for celecoxib, respectively. The method was linear over a concentration range of 0.05-2 and 0.05-10 µg/mL and limit of detection reached to 0.017 and 0.0167 µg/mL for amlodipine and celecoxib, respectively. The developed method was successfully applied to assess the cited drugs in their newly FDA approved fixed-dose combination tablet dosage form. Furthermore, the method was found to be sensitive and eco-friendly green alternative to the reported methods as it was evaluated according to the green analytical procedure index tool guidelines and analytical Eco-Scale.


Subject(s)
Amlodipine/analysis , Celecoxib/analysis , Fluorescence , Chromatography, High Pressure Liquid , Molecular Structure , Spectrometry, Fluorescence , Tablets
SELECTION OF CITATIONS
SEARCH DETAIL
...