Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Anesth Analg ; 125(6): 2009-2018, 2017 12.
Article in English | MEDLINE | ID: mdl-28991114

ABSTRACT

BACKGROUND: Burnout affects all medical specialists, and concern about it has become common in today's health care environment. The gold standard of burnout measurement in health care professionals is the Maslach Burnout Inventory-Human Services Survey (MBI-HSS), which measures emotional exhaustion, depersonalization (DP), and personal accomplishment. Besides affecting work quality, burnout is thought to affect health problems, mental health issues, and substance use negatively, although confirmatory data are lacking. This study evaluates some of these effects. METHODS: In 2011, the American Society of Anesthesiologists and the journal Anesthesiology cosponsored a webinar on burnout. As part of the webinar experience, we included access to a survey using MBI-HSS, 12-item Short Form Health Survey (SF-12), Social Support and Personal Coping (SSPC-14) survey, and substance use questions. Results were summarized using sample statistics, including mean, standard deviation, count, proportion, and 95% confidence intervals. Adjusted linear regression methods examined associations between burnout and substance use, SF-12, SSPC-14, and respondent demographics. RESULTS: Two hundred twenty-one respondents began the survey, and 170 (76.9%) completed all questions. There were 266 registrants total (31 registrants for the live webinar and 235 for the archive event), yielding an 83% response rate. Among respondents providing job titles, 206 (98.6%) were physicians and 2 (0.96%) were registered nurses. The frequency of high-risk responses ranged from 26% to 59% across the 3 MBI-HSS categories, but only about 15% had unfavorable scores in all 3. Mean mental composite score of the SF-12 was 1 standard deviation below normative values and was significantly associated with all MBI-HSS components. With SSPC-14, respondents scored better in work satisfaction and professional support than in personal support and workload. Males scored worse on DP and personal accomplishment and, relative to attending physicians, residents scored worse on DP. There was no significant association between MBI-HSS and substance use. CONCLUSIONS: Many anesthesiologists exhibit some high-risk burnout characteristics, and these are associated with lower mental health scores. Personal and professional support were associated with less emotional exhaustion, but overall burnout scores were associated with work satisfaction and professional support. Respondents were generally economically satisfied but also felt less in control at work and that their job kept them from friends and family. The association between burnout and substance use may not be as strong as previously believed. Additional work, perhaps with other survey instruments, is needed to confirm our results.


Subject(s)
Alcohol Drinking/psychology , Anesthesiologists/psychology , Burnout, Professional/psychology , Depression/psychology , Health Surveys/methods , Substance-Related Disorders/psychology , Adult , Alcohol Drinking/epidemiology , Burnout, Professional/diagnosis , Burnout, Professional/epidemiology , Depression/diagnosis , Depression/epidemiology , Female , Humans , Job Satisfaction , Male , Middle Aged , Substance-Related Disorders/diagnosis , Substance-Related Disorders/epidemiology , Workload/psychology
2.
Anesth Analg ; 122(4): 1062-9, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26702866

ABSTRACT

BACKGROUND: Rapid infusers are vital tools during massive hemorrhage and resuscitation. Sporadic reports of overheating and shutdown of the Belmont® Rapid Infuser, a commonly used system, have been attributed to 1-sided clot blockage of the fluid path. We investigated multiple causes of failure of this device. METHODS: Packed red blood cells and thawed fresh frozen plasma with normal saline solution were used as base fluids for serial 10-minute trials using standard disposable sets in 2 Belmont devices. Possible contributors to device failure, including calcium-containing solutions and external leakage currents, were evaluated. Thermographic images of the heater and disposable cartridges were recorded. The effects of complete unilateral clotting were modeled by sealing half of the disposable cartridge with epoxy. RESULTS: Clotting on the surface of the heat exchanger coil increased with calcium concentration and was only observed at calcium concentrations >12.0 mmol/L (P < 0.0001) in a 1:1 plasma:red blood cell mixture, resulting in high-pressure downstream occlusion alarms and interruption of flow. CONCLUSIONS: Clot-based occlusion can be induced in the Belmont Rapid Infuser under unrealistic conditions. In the absence of complete unilateral flow blockage, we did not observe any significant overheating of the infuser under extreme operating conditions.


Subject(s)
Equipment Failure , Erythrocytes , Infusion Pumps/standards , Plasma , Fluid Therapy/methods , Fluid Therapy/standards , Humans , Pilot Projects
3.
Anesthesiology ; 114(1): 194-204, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21178675

ABSTRACT

BACKGROUND: Burnout can lead to health and psychologic problems and is apparently increasing in physicians and nurses. Previous studies have not evaluated all healthcare workers within a single work unit. This study evaluates the risk of burnout in all medical personnel in one perioperative unit. METHODS: We developed an online survey that included demographics, a modified version of the Maslach Burnout Inventory-Human Services Survey, and the Social Support and Personal Coping Survey. Survey constructs (e.g., depersonalization and health) and a global score were calculated. Larger construct and global values were associated with higher risk of burnout. These were separately regressed on role, age, and sex. The global score was then regressed on each of the survey constructs. RESULTS: Of the 145 responses, 46.2% were physicians (22.8% residents), 43.4% were nurses or nurse anesthetists, and 10.3% were other personnel. After adjusting for sex and age, residents scored higher than other physicians on the following (expected change [95% confidence interval]): global score (1.12 [0.43-1.82]), emotional exhaustion (1.54 [0.44-2.60]), and depersonalization (1.09 [0.23-1.95]). Compared with nonphysicians, residents were 1 U or more higher on these items (P < 0.05 in all cases). Residents had higher health (1.49 [0.48-2.50]) and workload (1.23 [0.07-2.40]) values compared with physicians. Better health, personal support, and work satisfaction scores were related to decreased global scores (P < 0.05). CONCLUSIONS: Physicians (particularly residents) had the largest global burnout scores, implying increased risk of burnout. Improving overall health, increasing personal support, and improving work satisfaction may decrease burnout among perioperative team members.


Subject(s)
Burnout, Professional/epidemiology , Health Personnel/psychology , Perioperative Care/psychology , Adaptation, Psychological , Age Distribution , Female , Health Personnel/statistics & numerical data , Health Status , Humans , Internship and Residency , Job Satisfaction , Male , Middle Aged , Nurse Anesthetists/psychology , Nurse Anesthetists/statistics & numerical data , Nurses/psychology , Nurses/statistics & numerical data , Perioperative Care/statistics & numerical data , Physicians/psychology , Physicians/statistics & numerical data , Psychiatric Status Rating Scales/statistics & numerical data , Risk Factors , Sex Distribution , Social Support , Surveys and Questionnaires , Workload/psychology , Workload/statistics & numerical data
4.
Anesth Analg ; 110(5): 1480-5, 2010 May 01.
Article in English | MEDLINE | ID: mdl-20418309

ABSTRACT

BACKGROUND: In this study, we performed the infraclavicular block with combined ultrasound guidance and neurostimulation to selectively target cords to compare the success rates of placing a single injection of local anesthetic either in a central or peripheral location. METHODS: Two hundred eighteen patients were enrolled in a consecutive, prospective study. Patients were randomized to injection of local anesthetic either centrally (posterior cord) or peripherally (medial or lateral cord) using ultrasound guidance and neurostimulation. Supervised senior anesthesiology residents or attending anesthesiologists performed the blocks. Both intent-to-treat and treatment-received analyses were used to compare central and peripheral placement efficacy. RESULTS: The overall success rate was significantly higher for the central placements than peripheral placements (96% vs 85%, P = 0.004). Individual cord success rates were as follows: posterior 99%, lateral 92%, and medial 84% (P = 0.001). The central group required attending physician intervention more frequently (27% vs 6%, P < 0.001). Postoperative pain scores of < or =3 were more likely with central placement (100% vs 94%, P = 0.012). CONCLUSION: Central placement of a single injection of local anesthetic targeted at the posterior cord resulted in a higher success rate for infraclavicular block.


Subject(s)
Anesthetics, Local/administration & dosage , Brachial Plexus/diagnostic imaging , Nerve Block/methods , Adult , Aged , Brachial Plexus/anatomy & histology , Electric Stimulation , Female , Humans , Logistic Models , Male , Middle Aged , Monitoring, Intraoperative , Movement/physiology , Muscle, Skeletal/physiology , Orthopedic Procedures , Pain, Postoperative/epidemiology , Prospective Studies , Sensation/physiology , Supine Position , Treatment Outcome , Ultrasonography , Upper Extremity/surgery , Young Adult
6.
Nursing ; 4 Suppl to Periodical Publication: 20-23, 2009 May.
Article in English | MEDLINE | ID: mdl-28196009
SELECTION OF CITATIONS