Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 930
Filter
1.
JPRAS Open ; 41: 116-127, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38984322

ABSTRACT

Introduction: Enhanced recovery after surgery (ERAS) protocols have been implemented to decrease opioid use and decrease patient hospital length of stay (LOS, days). Serratus anterior plane (SAP) blocks anesthetize the T2 through T9 dermatomes of the breast and can be applied intraoperatively. The purpose of this study was to compare postoperative opioid (OME) consumption and LOS between a control group, an ERAS group, and an ERAS/local anesthetic cocktail group in patients who underwent implant-based breast reconstruction. Methods: In this study, 142 women who underwent implant-based breast reconstruction between 2004 and 2020 were divided into Group A (46 patients), a historical cohort; Group B (73 patients), an ERAS/no-block control group; and Group C (23 patients), an ERAS/anesthetic cocktail study group. Primary outcomes of interest were postanesthesia care unit (PACU), inpatient and total hospital OME consumption, and PACU LOS. Results: A significant decrease was observed from Group A to C in PACU LOS (103.3 vs. 80.2 vs. 70.5; p = 0.011), OME use (25.1 vs. 11.4 vs. 5.7; p < 0.0001), and total hospital OME (120.3 vs. 95.2 vs. 35.9; p < 0.05). No difference was observed in inpatient OMEs between the three groups (95.2 vs. 83.8 vs. 30.8; p = 0.212). Despite not reaching statistical significance, Group C consumed an average of 50-60 % less opioids per patient than did Group B in PACU, inpatient, and total hospital OMEs. Conclusion: Local anesthetic blocks are important components of ERAS protocols. Our results demonstrate that a combination regional block with a local anesthetic cocktail in an ERAS protocol can decrease opioid consumption in implant-based breast reconstruction.

2.
Article in English | MEDLINE | ID: mdl-38997869

ABSTRACT

In children with juvenile idiopathic arthritis (JIA), the temporomandibular joint (TMJ) can be involved. To prevent TMJ damage due to inflammation, early recognition is important, for which contrast-enhanced magnetic resonance imaging (MRI) is the gold standard. In this study, the interobserver reliability and construct validity of the Juvenile Idiopathic Arthritis Magnetic Resonance Scoring System for Temporomandibular Joints (JAMRIS-TMJ) was assessed. Two radiologists independently examined 38 MRIs using the JAMRIS-TMJ scoring system. Inter-observer reliability was assessed by Cohen's (weighted) kappa (κ), 95% confidence intervals (CIs) and absolute agreement (%). Construct validity was assessed by correlation between the JAMRIS-TMJ items and TMJ involvement, active maximum interincisal mouth opening (AMIO), and anterior maximum voluntary bite force (AMVBF). The interobserver reliability for the JAMRIS-TMJ items varied from poor to good (κ = 0.18-0.61). Joint enhancement had the highest reliability (κ = 0.61). Correlations were found between TMJ involvement, AMIO, and the JAMRIS-TMJ items, although variation between radiologists and TMJ side existed. No correlation was found between AMVBF and the JAMRIS-TMJ items for both radiologists. The strongest correlations were found between most of the JAMRIS-TMJ items and AMIO. Our findings support the utility of AMIO as a clinical measure of TMJ status in children with JIA.

3.
Phys Rev Lett ; 132(21): 217001, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38856268

ABSTRACT

The density of quasiparticles typically observed in superconducting qubits exceeds the value expected in equilibrium by many orders of magnitude. Can this out-of-equilibrium quasiparticle density still possess an energy distribution in equilibrium with the phonon bath? Here, we answer this question affirmatively by measuring the thermal activation of charge-parity switching in a transmon qubit with a difference in superconducting gap on the two sides of the Josephson junction. We then demonstrate how the gap asymmetry of the device can be exploited to manipulate its parity.

4.
Proc Natl Acad Sci U S A ; 121(24): e2311241121, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38838020

ABSTRACT

We present the experimental finding of multiple simultaneous two-fold degeneracies in the spectrum of a Kerr oscillator subjected to a squeezing drive. This squeezing drive resulting from a three-wave mixing process, in combination with the Kerr interaction, creates an effective static two-well potential in the phase space rotating at half the frequency of the sinusoidal drive generating the squeezing. Remarkably, these degeneracies can be turned on-and-off on demand, as well as their number by simply adjusting the frequency of the squeezing drive. We find that when the detuning Δ between the frequency of the oscillator and the second subharmonic of the drive equals an even multiple of the Kerr coefficient K, [Formula: see text], the oscillator displays [Formula: see text] exact, parity-protected, spectral degeneracies, insensitive to the drive amplitude. These degeneracies can be explained by the unusual destructive interference of tunnel paths in the classically forbidden region of the double well static effective potential that models our experiment. Exploiting this interference, we measure a peaked enhancement of the incoherent well-switching lifetime, thus creating a protected cat qubit in the ground state manifold of our oscillator. Our results illustrate the relationship between degeneracies and noise protection in a driven quantum system.

5.
J Oral Rehabil ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38886597

ABSTRACT

BACKGROUND: Mandibular range of motion (MROM) variables are widely used to evaluate oral function. OBJECTIVE: The aim of this study was to establish the reliability of MROM variables in healthy children. METHODS: In this cross-sectional study, healthy children were examined 2 weeks apart. The following MROM variables were established: active maximum interincisal opening (AMIO), passive maximum interincisal opening (PMIO), protrusion and left and right laterotrusion. The reliability of the MROM measurements was determined by analysing the intra-class correlation coefficient (ICC), standard error of measurement (SEM), smallest detectable change (SDC) and limits of agreement (LoA). RESULTS: A total of 167 healthy children were examined. The ICC indicated good reliability for AMIO (0.885); excellent reliability for PMIO (0.925); and moderate reliability for protrusion (0.578), laterotrusion left (0.601) and laterotrusion right (0.634). The SDC was 0.9 mm for AMIO, 0.4 mm for PMIO, 2.2 mm for protrusion, 1.6 mm for laterotrusion left and 1.4 mm for laterotrusion right. The LoA was -5.67 to 5.82 for AMIO, -3.90 to 3.57 for PMIO, -3.89 to 3.55 for protrusion, -2.99 to 2.77 for laterotrusion left, and - 2.71 to 2.77 for laterotrusion right. CONCLUSIONS: AMIO and PMIO measurements are both highly reliable in healthy children. The low SDC indicate that AMIO and PMIO are promising longitudinal measurements. Protrusion and laterotrusion measurements had moderate reliability. These results support our clinical recommendation to measure AMIO rather than PMIO, as PMIO is more difficult and more time-consuming to perform than AMIO.

6.
Phys Rev Lett ; 132(18): 180601, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38759169

ABSTRACT

Qubits with predominantly erasure errors present distinctive advantages for quantum error correction (QEC) and fault-tolerant quantum computing. Logical qubits based on dual-rail encoding that exploit erasure detection have been recently proposed in superconducting circuit architectures, with either coupled transmons or cavities. Here, we implement a dual-rail qubit encoded in a compact, double-post superconducting cavity. Using an auxiliary transmon, we perform erasure detection on the dual-rail subspace. We characterize the behavior of the code space by a novel method to perform joint-Wigner tomography. This is based on modifying the cross-Kerr interaction between the cavity modes and the transmon. We measure an erasure rate of 3.981±0.003 (ms)^{-1} and a residual, postselected dephasing error rate up to 0.17 (ms)^{-1} within the code space. This strong hierarchy of error rates, together with the compact and hardware-efficient nature of this novel architecture, holds promise in realizing QEC schemes with enhanced thresholds and improved scaling.

7.
Bioinform Adv ; 4(1): vbae021, 2024.
Article in English | MEDLINE | ID: mdl-38456127

ABSTRACT

Summary: In clinical and biomedical research, multiple high-dimensional datasets are nowadays routinely collected from omics and imaging devices. Multivariate methods, such as Canonical Correlation Analysis (CCA), integrate two (or more) datasets to discover and understand underlying biological mechanisms. For an explorative method like CCA, interpretation is key. We present a sparse CCA method based on soft-thresholding that produces near-orthogonal components, allows for browsing over various sparsity levels, and permutation-based hypothesis testing. Our soft-thresholding approach avoids tuning of a penalty parameter. Such tuning is computationally burdensome and may render unintelligible results. In addition, unlike alternative approaches, our method is less dependent on the initialization. We examined the performance of our approach with simulations and illustrated its use on real cancer genomics data from drug sensitivity screens. Moreover, we compared its performance to Penalized Matrix Analysis (PMA), which is a popular alternative of sparse CCA with a focus on yielding interpretable results. Compared to PMA, our method offers improved interpretability of the results, while not compromising, or even improving, signal discovery. Availability and implementation: The software and simulation framework are available at https://github.com/nuria-sv/toscca.

8.
BMC Nurs ; 23(1): 160, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38443854

ABSTRACT

BACKGROUND: The nursing home residents' ability to carry out Activities of Daily Living (ADLs) is influenced by the physical care environment. One emerging area of interest in scientific research is the green care environment within nursing home care, where agricultural activities such as gardening and animal care are integrated alongside daily care. Previous research has neglected to explore how these environments can be employed to enhance ADL performance. This study, therefore, explores how a green care environment, specifically one with an animal shelter, can be used to support nursing home residents in their ADLs. METHODS: A focused ethnographic case study was conducted in one nursing home. Data was collected employing participatory observations, informal conversations, and semi-structured interviews, which we analyzed by employing a thematic analysis. RESULTS: Overall, 25 residents were observed for a total time of 89h, and interviews were conducted with 10 staff members. The nursing home integrates activities in the green care environment into daily care for a broad scope of residents. The analysis revealed four themes: (1) The (in)visibility of ADL, (2) Reciprocal care dynamics: Fostering ADL performance through connection and teamwork, (3) Seized and missed opportunities for meaningful integration of ADL in the physical green care environment, and Theme (4) Professional fulfillment and ADL task obligation: Views from staff and management. CONCLUSIONS: This physical green care environment carries the potential to enhance the residents' daily activities and foster better staff-resident relationships. Yet, there are varying views among staff and management regarding its integration into the residents' lives and care.

9.
Tissue Eng Part A ; 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38420632

ABSTRACT

An essential aspect of cardiovascular in situ tissue engineering (TE) is to ensure balance between scaffold degradation and neo-tissue formation. We evaluated the rate of degradation and neo-tissue formation of three electrospun supramolecular bisurea-based biodegradable scaffolds that differ in their soft-block backbone compositions only. Scaffolds were implanted as interposition grafts in the abdominal aorta in rats, and evaluated at different time points (t = 1, 6, 12, 24, and 40 weeks) on function, tissue formation, strength, and scaffold degradation. The fully carbonate-based biomaterial showed minor degradation after 40 weeks in vivo, whereas the other two ester-containing biomaterials showed (near) complete degradation within 6-12 weeks. Local dilatation was only observed in these faster degrading scaffolds. All materials showed to some extent mineralization, at early as well as late time points. Histological evaluation showed equal and non-native-like neo-tissue formation after total degradation. The fully carbonate-based scaffolds lagged in neo-tissue formation, presumably as its degradation was (far from) complete at 40 weeks. A significant difference in vessel wall contrast enhancement was observed by magnetic resonance imaging between grafts with total compared with minimal-degraded scaffolds.

10.
Int J Biol Macromol ; 262(Pt 2): 130103, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38346616

ABSTRACT

Extraction of seaweed compounds using Deep Eutectic Solvents (DES) has shown high interest. Quantification, however, is challenging due to interactions with DES components. In this research work, three chemical separation techniques were investigated to isolate and quantify alginate from a set of choline chloride-based DES. While choline chloride served as the hydrogen bond acceptor (HBA); Urea, Ethylene Glycol, Propylene Glycol, Glycerol, Sorbitol, Xylitol and Glucose were used as hydrogen bond donors (HBD). DES containing sodium alginate were subjected to precipitation with sulfuric acid 0.2 M (pH 1.6), ethanol-water mixture (80 % v/v) and calcium chloride (1 % w/v CaCl2·2H2O). Alginate in precipitates was quantified and used to evaluate the performance of each separation technique. The highest recovery yields (51.2 ± 1.3 %) were obtained using the ethanol-water mixture followed by calcium chloride (45.7 ± 1.2 %), except for polyols (e.g. sorbitol). The lowest recovery yields were obtained with acid, with a particularly low recovery yield when urea was used as HBD (9.6 ± 1.3 %). Estimations of ManA/GulA ratios showed lower values for precipitates from DES compared to the ones obtained from water. This research shows ethanolic precipitation as a suitable method for alginate separation from the studied set of choline chloride-based DES.


Subject(s)
Choline , Deep Eutectic Solvents , Choline/chemistry , Solvents/chemistry , Alginates , Calcium Chloride , Water , Ethanol , Urea/chemistry , Sorbitol
11.
Plast Reconstr Surg ; 153(3): 650e-655e, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37220273

ABSTRACT

BACKGROUND: Microsurgery is conducted on tiny anatomical structures such as blood vessels and nerves. Over the past few decades, little has changed in the way plastic surgeons visualize and interact with the microsurgical field. New advances in augmented reality (AR) technology present a novel method for microsurgical field visualization. Voice- and gesture-based commands can be used in real time to adjust the size and position of a digital screen. Surgical decision support and/or navigation may also be used. The authors assess the use of AR in microsurgery. METHODS: The video feed from a Leica Microsystems OHX surgical microscope was streamed to a Microsoft HoloLens2 AR headset. A fellowship-trained microsurgeon and three plastic surgery residents then performed a series of four arterial anastomoses on a chicken thigh model using the AR headset, a surgical microscope, a video microscope (or "exoscope"), and surgical loupes. RESULTS: The AR headset provided an unhindered view of the microsurgical field and peripheral environment. The subjects remarked on the benefits of having the virtual screen track with head movements. The ability of participants to place the microsurgical field in a tailored comfortable, ergonomic position was also noted. Points of improvement were the low image quality compared with current monitors, image latency, and the lack of depth perception. CONCLUSIONS: AR is a useful tool that has the potential to improve microsurgical field visualization and the way surgeons interact with surgical monitors. Improvements in screen resolution, latency, and depth of field are needed.


Subject(s)
Augmented Reality , Plastic Surgery Procedures , Surgery, Plastic , Humans , Microsurgery/methods , Neurosurgical Procedures/methods
12.
Adv Skin Wound Care ; 37(1): 9-18, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38117166

ABSTRACT

GENERAL PURPOSE: To review burn care, with an emphasis on burn-specific issues and treatment. TARGET AUDIENCE: This continuing education activity is intended for physicians, physician assistants, nurse practitioners, and nurses with an interest in skin and wound care. LEARNING OBJECTIVES/OUTCOMES: After participating in this educational activity, the participant will:1. Select the appropriate treatment guidelines for patients who have burn injuries.2. Identify common complications of major burns.3. Choose the recommended pharmacologic approaches to burn care.


Care of burns, particularly those that are deep and/or extensive, requires a very specific approach from a multidisciplinary team of different types of experts. In contrast to many chronic lesions, large burns are also immediately life-threatening and have significant systemic effects that require specialized treatment as well. This article provides a high-level overview of burn care with an emphasis on these burn-specific issues and treatment.


Subject(s)
Nurse Practitioners , Physicians , Humans , Education, Continuing , Skin
13.
Prenat Diagn ; 43(13): 1638-1649, 2023 12.
Article in English | MEDLINE | ID: mdl-37955580

ABSTRACT

Lysosomal storage disorders (LSDs) are a group of monogenic condition, with many characterized by an enzyme deficiency leading to the accumulation of an undegraded substrate within the lysosomes. For those LSDs, postnatal enzyme replacement therapy (ERT) represents the standard of care, but this treatment has limitations when administered only postnatally because, at that point, prenatal disease sequelae may be irreversible. Furthermore, most forms of ERT, specifically those administered systemically, are currently unable to access certain tissues, such as the central nervous system (CNS), and furthermore, may initiate an immune response. In utero enzyme replacement therapy (IUERT) is a novel approach to address these challenges evaluated in a first-in-human clinical trial for IUERT in LSDs (NCT04532047). IUERT has numerous advantages: in-utero intervention may prevent early pathology; the CNS can be accessed before the blood-brain barrier forms; and the unique fetal immune system enables exposure to new proteins with the potential to prevent an immune response and may induce sustained tolerance. However, there are challenges and limitations for any fetal procedure that involves two patients. This article reviews the current state of IUERT for LSDs, including its advantages, limitations, and potential future directions for definitive therapies.


Subject(s)
Enzyme Replacement Therapy , Lysosomal Storage Diseases , Pregnancy , Female , Humans , Enzyme Replacement Therapy/methods , Lysosomal Storage Diseases/therapy , Lysosomal Storage Diseases/complications , Central Nervous System , Lysosomes
14.
BMC Nurs ; 22(1): 394, 2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37853344

ABSTRACT

BACKGROUND: Research shows that half of person(s) living with dementia (PLWD) receive care which they resist and/or have not given consent to, defined as involuntary treatment. District nurses play a key role in providing this care. Knowledge about how district nurses experience involuntary treatment is lacking. Therefore, the aim of this study was to describe the experiences of district nurses who used involuntary treatment for PLWD at home. METHODS: A qualitative descriptive design using semi-structured interviews. Sixteen district nurses with experience in involuntary treatment for PLWD were recruited through purposive sampling. Data were analysed using the Qualitative Analysis Guide of Leuven. RESULTS: District nurses' experiences with involuntary treatment were influenced by their involvement in the decision-making process. When they were involved, they considered involuntary treatment use to be appropriate care. However, at the moment that involuntary treatment use was started, district nurses were worried that its use was unjust since they wished to respect the wishes of the PLWD. Eventually, district nurses found, from a professional perspective, that involuntary treatment use was necessary, and that safety outweighed the autonomy of the PLWD. District nurses experienced dealing with this dilemma as stressful, due to conflicting values. If district nurses were not involved in the decision-making process regarding the use of involuntary treatment, family caregivers generally decided on its use. Often, district nurses perceived this request as inappropriate dementia care and they first tried to create a dialogue with the family caregivers to reach a compromise. However, in most cases, family caregivers stood by their request and the district nurse still provided involuntary treatment and found this difficult to tolerate. CONCLUSIONS: Our results show that district nurses experience involuntary treatment use as stressful due to dealing with obverse values of safety versus autonomy. To prevent involuntary treatment use and obverse values, we need to increase their ethical awareness, communication skills, knowledge and skills with person-centred care so they can deal with situations that can evolve into involuntary treatment use in a person-centred manner.

15.
J Clin Nurs ; 32(19-20): 7175-7192, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37458214

ABSTRACT

AIMS: To gain insights into the barriers towards the prevention and/or reduction of involuntary treatment in long-term geriatric care. DESIGN: Mixed methods. BACKGROUND: Measures to which a person resists and/or does not provide consent for are defined as involuntary treatment. The use of involuntary treatment violates the autonomy of (older) persons and causes more harm than benefit. Moreover, it contradicts the values of person-centred care. Nevertheless, its use among people living with dementia (PLWD) is still common practice. METHODS: We conducted a cross-sectional, mixed methods study, including an online survey for professional caregivers and a semistructured focus group interview with professional caregivers. RESULTS: A total of 218 participants completed the questionnaire. The percentage of participants who perceived barriers in one of the 22 survey items ranged from 15% to 42%. Lack of time, the experienced need to use involuntary treatment, uncertainty about responsibilities of stakeholders and a lack of knowledge on methods to prevent and/or reduce the use of involuntary treatment were most seen as barriers. Nursing staff perceived a lack of time hindering them in the prevention or reduction of involuntary treatment more often than other professional caregivers. Working in home care and having no former experience with involuntary treatment usage increased perceived barriers. Participants of the focus group interview confirmed these findings and added that professional caregivers in general lack awareness on the concept of involuntary treatment. CONCLUSIONS: One out of four professional caregivers experiences barriers hindering prevention and/or reduction of involuntary treatment. More research is needed to gain a better understanding of how professional caregivers can be supported to remove barriers and, consequently, prevent and/or reduce the use of involuntary treatment. RELEVANCE TO CLINICAL PRACTICE: Professional caregivers experience many barriers towards the prevention and reduction of involuntary treatment. Future initiatives should aim to remove the perceived barriers.


Subject(s)
Home Care Services , Involuntary Treatment , Humans , Aged , Aged, 80 and over , Caregivers , Long-Term Care , Cross-Sectional Studies
16.
J Rheumatol ; 50(11): 1462-1470, 2023 11.
Article in English | MEDLINE | ID: mdl-37399466

ABSTRACT

OBJECTIVE: To study clinical variables defining temporomandibular function in adults with juvenile idiopathic arthritis (JIA) and healthy controls. METHODS: In this cross-sectional study, the temporomandibular joint (TMJ) screening protocol, mandibular range of motion (MROM), and anterior maximum voluntary bite force (AMVBF) were compared between adults with JIA and healthy controls. Unadjusted and adjusted models with corrections for sex and disease duration were constructed for active maximum interincisal mouth opening (AMIO) and AMVBF. RESULTS: A total of 100 adults with JIA and 59 healthy adults were included in this study. In adults with JIA, 56% had clinically established TMJ involvement. AMIO was the MROM variable most reduced by TMJ involvement; AMIO was 8.8 mm (95% CI -11.40 to -6.12; P < 0.001) less in adults with JIA with TMJ involvement compared to JIA without TMJ involvement. No differences of AMIO were found between healthy adults and adults with JIA without TMJ involvement (-2.52, 95% CI -5.13 to 0.10; P = 0.06). Male sex was associated with a higher AMIO, and disease duration was associated with a decreased AMIO. Collinearity between the subtype prebiologic era and disease duration was found. AMVBF did not differ between adults with JIA and healthy adults. CONCLUSION: The high prevalence of clinically established TMJ involvement in adults with JIA indicates the need for awareness of TMJ problems in adults with JIA. TMJ involvement negatively influenced AMIO and should therefore be part of the TMJ screening in adults with JIA. AMVBF seems to have less utility for TMJ screening in adult populations.


Subject(s)
Arthritis, Juvenile , Temporomandibular Joint Disorders , Humans , Male , Adult , Temporomandibular Joint Disorders/complications , Cross-Sectional Studies , Temporomandibular Joint , Prevalence , Magnetic Resonance Imaging
17.
Proc (Bayl Univ Med Cent) ; 36(4): 501-509, 2023.
Article in English | MEDLINE | ID: mdl-37334077

ABSTRACT

Introduction: Perioperative pain control is an important component of any plastic surgery practice. Due to the incorporation of Enhanced Recovery after Surgery (ERAS) protocols, reported pain level, opioid consumption, and hospital length of stay numbers have decreased significantly. This article provides an up-to-date review of current ERAS protocols in use, reviews individual aspects of ERAS protocols, and discusses future directions for the continual improvement of ERAS protocols and control of postoperative pain. ERAS components: ERAS protocols have proven to be excellent methods of decreasing patient pain, opioid consumption, and postanesthesia care unit (PACU) and/or inpatient length of stay. ERAS protocols have three phases: preoperative education and pre-habilitation, intraoperative anesthetic blocks, and a postoperative multimodal analgesia regimen. Intraoperative blocks consist of local anesthetic field blocks and a variety of regional blocks, with lidocaine or lidocaine cocktails. Various studies throughout the surgical literature have demonstrated the efficacy of these aspects and their relevance to the overall goal of decreasing patient pain, both in plastic surgery and other surgical fields. In addition to the individual ERAS phases, ERAS protocols have shown promise in both the inpatient and outpatient sectors of plastic surgery of the breast. Conclusion: ERAS protocols have repeatedly been shown to provide improved patient pain control, decreased hospital or PACU length of stay, decreased opioid use, and cost savings. Although protocols have most commonly been utilized in inpatient plastic surgery procedures of the breast, emerging evidence points towards similar efficacy when used in outpatient procedures. Furthermore, this review demonstrates the efficacy of local anesthetic blocks in controlling patient pain.

18.
J Nurs Scholarsh ; 55(6): 1092-1105, 2023 11.
Article in English | MEDLINE | ID: mdl-37278376

ABSTRACT

INTRODUCTION: Supporting care receivers in Activities of Daily Living (ADL), irrespective of diagnosis, setting, or cultural background, lies at the heart of fundamental nursing care. The pursuit of quality ADL care becomes increasingly challenging with the changing complexity of care needs. ADL care delivery is often undervalued and is considered a low-status task despite its crucial importance to care receivers. This study aims to synthesize challenges in ADL care irrespective of the care setting. METHODS: In the mixed qualitative methods study, we used expert panel consultations, world café sessions, and a rapid literature review. For data analysis, we simultaneously analyzed the three data sets using inductive and deductive inquiry. RESULTS: We identified four challenges and their corresponding subthemes. They are (1) Undervalued common-sense work versus complex, high-skilled care provision; (2) Limitations in professional reflective clinical decision-making; (3) Missed opportunities for shared ADL decisions; and (4) Meeting ADL care needs in a high-throughput system. CONCLUSION: These challenges reveal the complexity of ADL care and how its paradoxical narrative relates to the conditions in which nursing professionals struggle to create opportunities, for reflective clinical reasoning and shared ADL decisions, by facing organizational and environmental barriers. CLINICAL RELEVANCE: This study is relevant to nursing professionals, care organizations, policymakers, and researchers aiming to improve ADL care and provide insights into challenges in ADL care. This study forms the starting point for a changing narrative on ADL nursing care and subsequent quality improvements in the form of, for example, guidelines for nursing professionals.


Subject(s)
Activities of Daily Living , Nursing Care , Humans , Delivery of Health Care , Narration , Quality of Health Care
19.
Biotechnol Bioeng ; 120(10): 2989-3000, 2023 10.
Article in English | MEDLINE | ID: mdl-37309984

ABSTRACT

The implementation of continuous processing in the biopharmaceutical industry is hindered by the scarcity of process analytical technologies (PAT). To monitor and control a continuous process, PAT tools will be crucial to measure real-time product quality attributes such as protein aggregation. Miniaturizing these analytical techniques can increase measurement speed and enable faster decision-making. A fluorescent dye (FD)-based miniaturized sensor has previously been developed: a zigzag microchannel which mixes two streams under 30 s. Bis-ANS and CCVJ, two established FDs, were employed in this micromixer to detect aggregation of the biopharmaceutical monoclonal antibody (mAb). Both FDs were able to robustly detect aggregation levels starting at 2.5%. However, the real-time measurement provided by the microfluidic sensor still needs to be implemented and assessed in an integrated continuous downstream process. In this work, the micromixer is implemented in a lab-scale integrated system for the purification of mAbs, established in an ÄKTA™ unit. A viral inactivation and two polishing steps were reproduced, sending a sample of the product pool after each phase directly to the microfluidic sensor for aggregate detection. An additional UV sensor was connected after the micromixer and an increase in its signal would indicate that aggregates were present in the sample. The at-line miniaturized PAT tool provides a fast aggregation measurement, under 10 min, enabling better process understanding and control.


Subject(s)
Antibodies, Monoclonal , Biological Products , Technology
20.
JMIR Res Protoc ; 12: e41485, 2023 May 03.
Article in English | MEDLINE | ID: mdl-37133908

ABSTRACT

BACKGROUND: COVID-19 has highlighted already existing human resource gaps in health care systems. New Brunswick health care services are significantly weakened by a shortage of nurses and physicians, affecting regions where Official Language Minority Communities (OLMCs) reside. Since 2008, Vitalité Health Network (the "Network"), whose work language is French (with services delivered in both official languages, English and French), has provided health care to OLMCs in New Brunswick. The Network currently needs to fill hundreds of vacant physician and nurse positions. It is imperative to strengthen the network's retention strategies to ensure its viability and maintain adequate health care services for OLMCs. The study is a collaborative effort between the Network (our partner) and the research team to identify and implement organizational and structural strategies to upscale retention. OBJECTIVE: The aim of this study is to support one of New Brunswick health networks in identifying and implementing strategies to promote physician and registered nurse retention. More precisely, it wishes to make 4 important contributions to identify (and enhance our understanding of) the factors related to the retention of physicians and nurses within the Network; determine, based on the "Magnet Hospital" model and the "Making it Work" framework, on which aspects of the Network's environment (internal or external) it should focus for its retention strategy; define clear and actionable practices to help the Network replenish its strength and vitality; and improve the quality of health care services to OLMCs. METHODS: The sequential methodology combines quantitative and qualitative approaches based on a mixed methods design. For the quantitative part, data collected through the years by the Network will be used to take stock of vacant positions and examine turnover rates. These data will also help determine which areas have the most critical challenges and which ones have more successful approaches regarding retention. Recruitment will be made in those areas for the qualitative part of the study to conduct interviews and focus groups with different respondents, either currently employed or who have left it in the last 5 years. RESULTS: This study was funded in February 2022. Active enrollment and data collection started in the spring of 2022. A total of 56 semistructured interviews were conducted with physicians and nurses. As of manuscript submission, qualitative data analysis is in progress and quantitative data collection is intended to end by February 2023. Summer and fall 2023 is the anticipated period to disseminate the results. CONCLUSIONS: Applying the "Magnet Hospital" model and the "Making it Work" framework outside urban settings will offer a novel outlook to the knowledge of professional resource shortages within OLMCs. Furthermore, this study will generate recommendations that could contribute to a more robust retention plan for physicians and registered nurses. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/41485.

SELECTION OF CITATIONS
SEARCH DETAIL
...