1.
Electrophoresis ; 29(8): 1753-60, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18383020

ABSTRACT

Hyperlink robust biocompatible solid-phase microextraction (SPME) devices were prepared using continuous bed (monolithic) restricted-access media (RAM) as the SPME capillary insert. The RAM-based SPME approach was able to simultaneously separate proteins from a biological sample, while directly extracting the active components of caffeine, paracetamol and acetylsalicylic acid from the drug NeoCitramonum. The devices were interfaced with a CZE system and fully automated analysis for sample preconcentration, desorption, separation and quantification of analytes was evaluated. Comparative study of in-line coupled SPME-CZE using RAM and RP capillary inserts was carried out. Using an SPME (RAM) insert, the calculated caffeine, paracetamol and acetylsalicylic acid LODs in a bovine plasma sample were 0.3, 0.8 and 1.9 ng/mL, respectively.


Subject(s)
Body Fluids/chemistry , Electrophoresis, Capillary/methods , Pharmaceutical Preparations/analysis , Electrophoresis, Capillary/instrumentation , Humans
2.
Bioelectrochemistry ; 67(1): 101-8, 2005 Sep.
Article in English | MEDLINE | ID: mdl-15967404

ABSTRACT

The change of the pH of a NaCl solution (139-149 mM NaCl) buffered with 5-15 mM sodium phosphates (pH 7.4) during electromanipulation was studied. It has been determined that an increase in the pH value of electroporation solution of a whole chamber volume, caused by the application of electric field pulses, commonly used in cell electromanipulation procedures, can exceed 1-2 pH units. Several materials for the cathode were tested. In all cases a stainless steel anode was utilized. The aluminum cathode gave a two-fold greater DeltapH in comparison with platinum, copper or stainless steel cathodes. In addition, a substantial release of aluminum (up to 1 mg/l) from the cathode was observed. It has also been found that the shift in pH depended on the medium conductivity: DeltapH of the solution, in which sucrose was substituted for NaCl, was about 5 times less. On the basis of the results obtained here, to avoid the plausible undesirable consequences of the cathodic electrolysis processes, in particular under the conditions of strong electric treatment, it could be recommended that chambers with aluminum electrodes not be utilized and one should use strongly buffered solutions of low conductivity and alternating current (sine or square wave) bipolar electric pulses.


Subject(s)
Electricity , Hydrogen-Ion Concentration , Phosphates/chemistry , Sodium Chloride/chemistry , Solutions/chemistry