Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE J Transl Eng Health Med ; 5: 2700111, 2017.
Article in English | MEDLINE | ID: mdl-29018637

ABSTRACT

The design of effective transcutaneous systems demands the consideration of inevitable variations in tissue characteristics, which vary across body areas, among individuals, and over time. The purpose of this paper was to design and evaluate several printed antenna topologies for ultrahigh frequency (UHF) transcutaneous power transfer to implantable medical devices, and to investigate the effects of variations in tissue properties on dipole and loop topologies. Here, we show that a loop antenna topology provides the greatest achievable gain with the smallest implanted antenna, while a dipole system provides higher impedance for conjugate matching and the ability to increase gain with a larger external antenna. In comparison to the dipole system, the loop system exhibits greater sensitivity to changes in tissue structure and properties in terms of power gain, but provides higher gain when the separation is on the order of the smaller antenna dimension. The dipole system was shown to provide higher gain than the loop system at greater implant depths for the same implanted antenna area, and was less sensitive to variations in tissue properties and structure in terms of power gain at all investigated implant depths. The results show the potential of easily-fabricated, low-cost printed antenna topologies for UHF transcutaneous power, and the importance of environmental considerations in choosing the antenna topology.

2.
Ultrasound Med Biol ; 43(3): 561-578, 2017 03.
Article in English | MEDLINE | ID: mdl-28038789

ABSTRACT

Totally implantable wireless ultrasonic blood flowmeters provide direct-access chronic vessel monitoring in hard-to-reach places without using wired bedside monitors or imaging equipment. Although wireless implantable Doppler devices are accurate for most applications, device size and implant lifetime remain vastly underdeveloped. We review past and current approaches to miniaturization and implant lifetime extension for wireless implantable Doppler devices and propose approaches to reduce device size and maximize implant lifetime for the next generation of devices. Additionally, we review current and past approaches to accurate blood flow measurements. This review points toward relying on increased levels of monolithic customization and integration to reduce size. Meanwhile, recommendations to maximize implant lifetime should include alternative sources of power, such as transcutaneous wireless power, that stand to extend lifetime indefinitely. Coupling together the results will pave the way for ultra-miniaturized totally implantable wireless blood flow monitors for truly chronic implantation.


Subject(s)
Flowmeters , Miniaturization/instrumentation , Prostheses and Implants , Regional Blood Flow/physiology , Ultrasonography, Doppler/instrumentation , Wireless Technology/instrumentation , Equipment Design , Humans , Reproducibility of Results
3.
IEEE J Transl Eng Health Med ; 4: 4100114, 2016.
Article in English | MEDLINE | ID: mdl-27730016

ABSTRACT

Current totally implantable wireless blood flow monitors are large and cannot operate alongside nearby monitors. To alleviate the problems with the current monitors, we developed a system to monitor blood flow wirelessly, with a simple and easily interpretable real-time output. To the best of our knowledge, the implanted electronics are the smallest in reported literature, which reduces bio-burden. Calibration was performed across realistic physiological flow ranges using a syringe pump. The device's sensors connected directly to the bilateral femoral veins of swine. For each 1 min, blood flow was monitored, then, an occlusion was introduced, and then, the occlusion was removed to resume flow. Each vein of four pigs was monitored four times, totaling 32 data collections. The implant measured 1.70 cm3 without battery/encapsulation. Across its calibrated range, including equipment tolerances, the relative error is less than ±5% above 8 mL/min and between -0.8% and +1.2% at its largest calibrated flow rate, which to the best of our knowledge is the lowest reported in the literature across the measured calibration range. The average standard deviation of the flow waveform amplitude was three times greater than that of no-flow. Establishing the relative amplitude for the flow and no-flow waveforms was found necessary, particularly for noise modulated Doppler signals. Its size and accuracy, compared with other microcontroller-equipped totally implantable monitors, make it a good candidate for future tether-free free flap monitoring studies.

4.
Plast Reconstr Surg ; 136(1): 199-203, 2015 Jul.
Article in English | MEDLINE | ID: mdl-26111323

ABSTRACT

Microvascular anastomotic failure remains an uncommon but devastating problem. Although the implantable Doppler probe is helpful in flap monitoring, the devices are cumbersome, easily dislodged, and plagued by false-positive results. The authors have developed an implantable wireless Doppler monitor prototype from off-the-shelf components and tested it in a swine model. The wireless probe successfully distinguished between femoral vein flow, occlusion, and reflow, and wirelessly reported the different signals reliably. This is the first description of a wireless implantable blood flow sensor for flap monitoring. Future iterations will incorporate an integrated microchip-based Doppler system that will decrease the size to 1 mm, small enough to fit onto an anastomotic coupler.


Subject(s)
Femoral Vein/physiology , Hemorheology , Monitoring, Physiologic/instrumentation , Prostheses and Implants , Surgical Flaps/blood supply , Ultrasonography, Doppler/instrumentation , Wireless Technology , Animals , Equipment Design , Female , Swine
6.
Ann Biomed Eng ; 41(9): 1913-25, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23897048

ABSTRACT

Translational research has recently been rediscovered as one of the basic tenants of engineering. Although many people have numerous ideas of how to accomplish this successfully, the fundamental method is to provide an innovative and creative environment. The University of Pittsburgh has been accomplishing this goal though a variety of methodologies. The contents of this paper are exemplary of what can be achieved though the interaction of students, staff, faculty and, in one example, high school teachers. While the projects completed within the groups involved in this paper have spanned other areas, the focus of this paper is on the biomedical devices, that is, towards improving and maintaining health in a variety of areas. The spirit of the translational research is discovery, invention, intellectual property protection, and the creation of value through the spinning off of companies while providing better health care and creating jobs. All but one of these projects involve wireless radio frequency (RF) energy for delivery. The remaining device can be wirelessly connected for data collection.


Subject(s)
Education, Professional/methods , Telemedicine , Translational Research, Biomedical/education , Translational Research, Biomedical/methods , Universities , Wireless Technology , Education, Professional/standards , Humans , Pennsylvania
7.
IEEE Trans Biomed Circuits Syst ; 7(3): 236-42, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23853323

ABSTRACT

The major problem in operating an implantable radio-frequency identification (RFID) tag embedded on an orthopedic implant is low efficiency because of metallic interference. To improve the efficiency, this paper proposes a method of operating an implantable passive RFID tag using a touch probe at 13.56 MHz. This technology relies on the electric field interaction between two pairs of electrodes, one being a part of the touch probe placed on the surface of tissue and the other being a part of the tag installed under the tissue. Compared with using a conventional RFID antenna such as a loop antenna, this method has a better performance in the near field operation range to reduce interference with the orthopedic implant. Properly matching the touch probe and the tag to the tissue and the implant reduces signal attenuation and increases the overall system efficiency. The experiments have shown that this method has a great performance in the near field transcutaneous operation and can be used for orthopedic implant identification.


Subject(s)
Orthopedics/methods , Prostheses and Implants , Radio Frequency Identification Device , Algorithms , Animals , Electrodes, Implanted , Electronics, Medical , Finite Element Analysis , Humans , Metals/chemistry , Prosthesis Design , Radio Waves , Signal Processing, Computer-Assisted , Sodium Chloride/chemistry , Swine
8.
IEEE Trans Inf Technol Biomed ; 15(6): 848-53, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21926027

ABSTRACT

Increasing density of wireless communication and development of radio frequency identification (RFID) technology in particular have increased the susceptibility of patients equipped with cardiac rhythmic monitoring devices (CRMD) to environmental electro magnetic interference (EMI). Several organizations reported observing CRMD EMI from different sources. This paper focuses on mathematically analyzing the energy as perceived by the implanted device, i.e., voltage. Radio frequency (RF) energy transmitted by RFID interrogators is considered as an example. A simplified front-end equivalent circuit of a CRMD sensing circuitry is proposed for the analysis following extensive black-box testing of several commercial pacemakers and implantable defibrillators. After careful understanding of the mechanics of the CRMD signal processing in identifying the QRS complex of the heart-beat, a mitigation technique is proposed. The mitigation methodology introduced in this paper is logical in approach, simple to implement and is therefore applicable to all wireless communication protocols.


Subject(s)
Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Equipment Failure Analysis/methods , Equipment Safety/methods , Pacemaker, Artificial/adverse effects , Radio Frequency Identification Device/methods , Radio Waves/adverse effects , Defibrillators, Implantable/adverse effects , Electromagnetic Fields/adverse effects , Electromagnetic Phenomena , Humans
9.
Otolaryngol Head Neck Surg ; 134(5): 862-7, 2006 May.
Article in English | MEDLINE | ID: mdl-16647549

ABSTRACT

OBJECTIVE: This article focuses on establishing communication between a functional muscle and a denervated muscle using a radiofrequency communications link. The ultimate objective of the project is to restore the eye blink in patients with facial nerve paralysis. STUDY DESIGN AND SETTING: Two sets of experiments were conducted using the gastrocnemius leg muscles of Sprague-Dawley rats. In the initial tests, varying magnitudes of voltages ranging from 0.85 to 2.5 V were applied directly to a denervated muscle to determine the voltage required to produce visible contraction. The second set of experiments was then conducted to determine the voltage output from an in vivo muscle contraction that could be sensed and used to coordinate a signal for actuation of a muscle in a separate limb. After designing the appropriate external communication circuitry, a third experiment was performed to verify that a signal between a functional and a denervated muscle can be generated and used as a stimulus. RESULTS: Voltages below 2 V at a 10-millisecond pulse width elicited a gentle, controlled contraction of the denervated muscle in vivo. It was also observed that with longer pulse widths, higher stimulation voltages were required to produce sufficient contractions. CONCLUSION: It is possible to detect contraction of a muscle, use this to generate a signal to an external base station, and subsequently cause a separate, denervated muscle to contract in response to the signal. SIGNIFICANCE: This demonstration in vivo of a signaling system for pacing of electrical stimulation of 1 muscle to spontaneous contraction of another, separate muscle, using radiofrequency communication without direct connection, may be used in numerous ways to overcome nerve damage.


Subject(s)
Muscle Contraction/physiology , Muscle Denervation , Muscle, Skeletal/physiopathology , Sound , Animals , Electric Stimulation , Hindlimb/innervation , Hindlimb/physiopathology , Muscle, Skeletal/innervation , Rats , Rats, Sprague-Dawley
SELECTION OF CITATIONS
SEARCH DETAIL
...