Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Opt Express ; 14(11): 5642-5655, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-38021142

ABSTRACT

Thrombus formation is a physiological response to damage in a blood vessel that relies on a complex interplay of platelets, coagulation factors, immune cells, and the vessel wall. The dynamics of thrombus formation are essential for a deeper understanding of many disease processes, like bleeding, wound healing, and thrombosis. However, monitoring thrombus formation is challenging due to the limited imaging options available to analyze flowing blood. In this work, we use a visible-light optical coherence tomography (vis-OCT) system to monitor the dynamic process of the formation of thrombi in a microfluidic blood vessel-on-chip (VoC) device. Inside the VoC, thrombi form in a channel lined with a monolayer of endothelial cells and perfused by human whole blood. We show that the correlation of the vis-OCT signal can be utilized as a marker for thrombus formation. By thresholding the correlation during thrombus formation, we track and quantify the growth of the thrombi over time. We validate our results with fluorescence microscopic imaging of fibrin and platelet markers at the end of the blood perfusion assay. In conclusion, we demonstrate that the correlation of the vis-OCT signal can be used to visualize both the spatial and temporal behavior of the thrombus formation in flowing human whole blood.

2.
Cardiovasc Res ; 117(14): 2742-2754, 2021 12 17.
Article in English | MEDLINE | ID: mdl-33729461

ABSTRACT

The development of organs-on-chip (OoC) has revolutionized in vitro cell-culture experiments by allowing a better mimicry of human physiology and pathophysiology that has consequently led researchers to gain more meaningful insights into disease mechanisms. Several models of hearts-on-chips and vessels-on-chips have been demonstrated to recapitulate fundamental aspects of the human cardiovascular system in the recent past. These 2D and 3D systems include synchronized beating cardiomyocytes in hearts-on-chips and vessels-on-chips with layer-based structures and the inclusion of physiological and pathological shear stress conditions. The opportunities to discover novel targets and to perform drug testing with chip-based platforms have substantially enhanced, thanks to the utilization of patient-derived cells and precise control of their microenvironment. These organ models will provide an important asset for future approaches to personalized cardiovascular medicine and improved patient care. However, certain technical and biological challenges remain, making the global utilization of OoCs to tackle unanswered questions in cardiovascular science still rather challenging. This review article aims to introduce and summarize published work on hearts- and vessels-on chips but also to provide an outlook and perspective on how these advanced in vitro systems can be used to tailor disease models with patient-specific characteristics.


Subject(s)
Heart Diseases , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/instrumentation , Myocytes, Cardiac , Animals , Cardiovascular Agents/therapeutic use , Cell Culture Techniques , Cells, Cultured , Clinical Decision-Making , Drug Development , Drug Discovery , Heart Diseases/drug therapy , Heart Diseases/metabolism , Heart Diseases/pathology , Heart Diseases/physiopathology , Humans , Myocytes, Cardiac/drug effects , Myocytes, Cardiac/metabolism , Myocytes, Cardiac/pathology , Precision Medicine
3.
Lab Chip ; 17(16): 2785-2792, 2017 08 08.
Article in English | MEDLINE | ID: mdl-28717801

ABSTRACT

Arterial thrombosis is the main instigating factor of heart attacks and strokes, which result in over 14 million deaths worldwide every year. The mechanism of thrombosis involves factors from the blood and the vessel wall, and it also relies strongly on 3D vessel geometry and local blood flow patterns. Microfluidic chip-based vascular models allow controlled in vitro studies of the interaction between vessel wall and blood in thrombosis, but until now, they could not fully recapitulate the 3D geometry and blood flow patterns of real-life healthy or diseased arteries. Here we present a method for fabricating microfluidic chips containing miniaturized vascular structures that closely mimic architectures found in both healthy and stenotic blood vessels. By applying stereolithography (SLA) 3D printing of computed tomography angiography (CTA) data, 3D vessel constructs were produced with diameters of 400 µm, and resolution as low as 25 µm. The 3D-printed templates in turn were used as moulds for polydimethylsiloxane (PDMS)-based soft lithography to create microfluidic chips containing miniaturized replicates of in vivo vessel geometries. By applying computational fluid dynamics (CFD) modeling a correlation in terms of flow fields and local wall shear rate was found between the original and miniaturized artery. The walls of the microfluidic chips were coated with human umbilical vein endothelial cells (HUVECs) which formed a confluent monolayer as confirmed by confocal fluorescence microscopy. The endothelialised microfluidic devices, with healthy and stenotic geometries, were perfused with human whole blood with fluorescently labeled platelets at physiologically relevant shear rates. After 15 minutes of perfusion the healthy geometries showed no sign of thrombosis, while the stenotic geometries did induce thrombosis at and downstream of the stenotic area. Overall, the novel methodology reported here, overcomes important design limitations found in typical 2D wafer-based soft lithography microfabrication techniques and shows great potential for controlled studies of the role of 3D vessel geometries and blood flow patterns in arterial thrombosis.


Subject(s)
Computed Tomography Angiography , Lab-On-A-Chip Devices , Models, Cardiovascular , Thrombosis , Cell Culture Techniques , Cell Line , Equipment Design , Human Umbilical Vein Endothelial Cells , Humans , Printing, Three-Dimensional