Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Int J Clin Pract ; 60(7): 863-6, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16846403

ABSTRACT

Therapy with aspirin and/or adenosine diphosphate (ADP) receptor blockers is associated with better outcomes via inhibition of platelet activity, and subsequent reduction of ischemic vascular events. Non-compliance (NC) is a well-recognised hazard limiting the clinical utility of antiplatelet agents, and, probably worsening outcomes. However, comprehensive platelet characteristics of a confirmed NC patient after acute vascular event have never been reported within a major randomised trial with ADP-receptor antagonists. A 48-year-old male patient, well-educated, was among patients enrolled in the platelet sub-study for the JUMBO trial. He received 325 mg of aspirin daily for 9 months, presented with unstable angina for urgent coronary intervention, and was successfully reperfused with two intracoronary stents. The patient was randomised to a 60 mg prasugrel loading dose, and 10 mg of prasugrel daily for 30 days. Platelets were assessed at baseline, 4 and 24 h, and at 30 days after acute coronary event utilising ADP-, and collagen-induced conventional aggregometry, rapid cartridge-based analyser and flow cytometry. Loading with prasugrel resulted in significant inhibition of platelet activity during and after stenting. However, after assessing platelet biomarkers at 30 days, voluntary withdrawal from the antiplatelet agents was suspected. Based on the platelet activity characteristics, NC was later confirmed, and the patient admitted that he stopped taking both prasugrel and aspirin shortly after discharge due to minor bleeding episodes after shaving. Major platelet activity biomarkers of the index NC patient were compared with those from compliant prasugrel-, clopidogrel-treated patients, and healthy controls. The platelet tests uniformly revealed rebound activation by all platelet measures (at least twofold increase) while being especially high for ADP-, and collagen-induced aggregation, platelet/endothelial cell adhesion molecule-1 (PECAM-1), glycoprotein (GP)Ib, GPIIb/IIIa activity, P-selectin, protease activated receptor (PAR)-1 thrombin receptor (activated and intact epitopes), and thrombospondin expression. The clinical benefits of antiplatelet agents are not only denied in NC outpatients, but may put them at additional risk for worsened vascular outcomes due to the rebound platelet activation. Proclaimed 'resistance' to antiplatelet agents may at least in part be a result of NC, especially in the chronic uncontrolled setting. Enforcing compliance will improve outcomes in the clinical trials, and save lives of patients really receiving antiplatelet therapy.


Subject(s)
Angina Pectoris/chemically induced , Aspirin/therapeutic use , Coronary Stenosis/chemically induced , Myocardial Ischemia/prevention & control , Piperazines/therapeutic use , Platelet Activation/drug effects , Platelet Aggregation Inhibitors/therapeutic use , Thiophenes/therapeutic use , Chronic Disease , Drug Therapy, Combination , Humans , Male , Middle Aged , Prasugrel Hydrochloride , Randomized Controlled Trials as Topic , Treatment Refusal
2.
Postgrad Med J ; 82(968): 404-10, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16754711

ABSTRACT

BACKGROUND: Based on the preclinical and phase 1 studies, prasugrel, a novel platelet ADP P2Y12 receptor blocker, may be a more potent platelet inhibitor than clopidogrel. This study compared the antiplatelet properties of prasugrel in a small subset of patients enrolled in the JUMBO trial, and compared with historic clopidogrel treated controls. METHODS AND RESULTS: Nine patients undergoing coronary stenting were randomised to one of three arms of prasugrel (40 mg loading, and 7.5 mg maintenance, n = 1; 60/10 mg, n = 4; or 60/15 mg, n = 2), or clopidogrel (300/75 mg, n = 2). Aspirin and GP IIb/IIIa inhibitors were permitted. Platelet activity was assessed at baseline, at 4, and 24 hours, and at 30 days after stent implantation in substudy participants, and compared with 124 historic controls who received clopidogrel. Independent of the loading, or maintenance dose, patients treated with prasugrel exhibited significantly more potent platelet inhibition as determined by ADP, and collagen induced aggregation, Ultegra Analyser, and surface expression of PECAM-1, GPIIb/IIIa antigen, and activity with PAC-1 antibody, GPIb, P-selectin, CD40-ligand, GP37, and thrombospondin receptor expression when compared with those treated with clopidogrel. There were no differences between antiplatelet agents with regard to vitronectin, LAMP-1, PAR-1 (intact and cleaved epitopes) thrombin receptor expression, or formation of platelet-monocyte microparticles. Expression of GPIIb antigen, vitronectin, and LAMP-3 receptor were not affected by both agents. Two patients treated with prasugrel 10 mg/daily exhibited complete inhibition of collagen induced aggregation at 30 days. CONCLUSION: At the dosing regimens chosen in the JUMBO trial, it seems that prasugrel is a more potent antiplatelet agent than clopidogrel. Two episodes of profound platelet inhibition, which are not seen with clopidogrel, raise the possibility of higher bleeding risks especially during long term prasugrel use. Whether stronger platelet inhibition will yield better clinical outcomes and/or increased bleeding remains to be determined in an ongoing comparative phase 3 superiority trial (TRITON).


Subject(s)
Coronary Disease/therapy , Piperazines/therapeutic use , Platelet Aggregation Inhibitors/therapeutic use , Platelet Aggregation/drug effects , Stents , Thiophenes/therapeutic use , Ticlopidine/analogs & derivatives , Clopidogrel , Female , Flow Cytometry , Humans , Male , Middle Aged , Prasugrel Hydrochloride , Purinergic P2 Receptor Antagonists , Ticlopidine/therapeutic use
3.
J Invasive Cardiol ; 13(4): 272-8, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11287711

ABSTRACT

Randomized controlled trials of patients with non-ST segment elevation acute coronary syndromes have established the superiority of enoxaparin (versus unfractionated heparin) for reducing adverse ischemic outcomes. Furthermore, adjunctive abciximab therapy during percutaneous coronary intervention (PCI) is associated with improved clinical outcomes. Since algorithms for integrating these pharmacotherapies have not been determined, patients undergoing elective PCI were enrolled into 2 distinct and separate studies conducted by the National Investigators Collaborating on Enoxaparin (NICE) study groups (NICE 1 and NICE 4 studies). Patients in NICE 1 were administered enoxaparin 1.0 mg/kg intravenously (without abciximab) and those enrolled in NICE 4 were administered a reduced dose (0.75 mg/kg) of enoxaparin in combination with standard-dose abciximab intravenously during PCI. Bleeding events and ischemic outcomes assessed in-hospital and at 30-days post-PCI were infrequent with either pharmacologic regimen. In the dose regimens studied, enoxaparin with or without abciximab appears to provide safe and effective anticoagulation during PCI. The combination of reduced-dose enoxaparin and abciximab was associated with a low incidence of adverse outcomes (bleeding or ischemic events). Additional studies may be required to establish the relative safety and efficacy of this new adjunctive pharmacologic strategy when compared with the combination of low-dose, weight-adjusted unfractionated heparin and abciximab.


Subject(s)
Angioplasty, Balloon, Coronary , Antibodies, Monoclonal/therapeutic use , Anticoagulants/therapeutic use , Coronary Disease/therapy , Enoxaparin/therapeutic use , Immunoglobulin Fab Fragments/therapeutic use , Abciximab , Antibodies, Monoclonal/administration & dosage , Anticoagulants/administration & dosage , Drug Administration Schedule , Drug Therapy, Combination , Enoxaparin/administration & dosage , Female , Humans , Immunoglobulin Fab Fragments/administration & dosage , Male , Middle Aged , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors
4.
Am J Cardiol ; 87(2): 157-62, 2001 Jan 15.
Article in English | MEDLINE | ID: mdl-11152831

ABSTRACT

The MULTI-LINK (ML) stent is a novel second generation coronary stent. The ACS MultiLink Stent Clinical Equivalence in De Novo Lesions Trial (ASCENT) randomized 1,040 patients with single, de novo native vessel lesions to treatment with the ML stent or the benchmark Palmaz-Schatz (PS) stent, to demonstrate that the ML stent was not inferior to (i.e., equivalent or better than) the PS stent in terms of target vessel failure by 9 months. Successful stent delivery was achieved in 98.8% versus 96.9% of patients, with a slightly lower postprocedural diameter stenosis (8% vs 10%, p = 0.04), and no difference in 30-day major adverse cardiac events (5.0% vs 6.5%) for the ML stent versus the PS stent. The primary end point of target vessel failure at 9 months was seen in 15.1% of ML-treated patients versus 16.7% of PS-treated patients, with the ML proving to be equal or superior to the PS stent (p <0.001 by test for equivalency). In a prespecified subset, angiographic restudy showed a nonsignificant trend for reduced ML restenosis (16.0% vs 22.1%). Thus, the ML stent showed excellent deliverability and acute results, with 9-month clinical and 6-month angiographic outcomes that were equivalent or better than the PS stent.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Disease/therapy , Stents , Aged , Coronary Angiography , Female , Humans , Male , Middle Aged , Recurrence , Regression Analysis , Survival Analysis , Treatment Outcome
5.
Am J Cardiol ; 84(12): 1385-90, 1999 Dec 15.
Article in English | MEDLINE | ID: mdl-10606109

ABSTRACT

The MULTI-LINK DUET is the next generation MULTI-LINK stent with modified strut geometry. Safety and efficacy of the MULTI-LINK DUET were evaluated in a prospective multicenter registry and were compared with prior MULTI-LINK stent experience from the ASCENT randomized trial. A total of 270 patients received 302 MULTI-LINK DUET stents and were evaluated using a composite primary end point of major cardiac events (death, Q-wave and non-Q-wave myocardial infarction, and requirement for coronary revascularization) attributable to the target stenosis cumulative to 30 days following enrollment. Quantitative coronary angiography was performed at a mean follow-up of 6 +/- 2 (+/-SD) months. No difference in primary end point or in angiographic restenosis to 6 months was observed between MULTI-LINK DUET and MULTI-LINK experiences. The MULTI-LINK DUET demonstrated improved device and procedural success, less postprocedural in-stent stenosis, larger postprocedural minimal lumen diameter, and fewer postprocedural marginal dissections compared with the MULTI-LINK stent. Multivariate regression modeling identified stent length, diabetes mellitus, poststent minimal lumen diameter, lesion eccentricity, and current smoking as independent predictors of in-stent restenosis. Thus, the MULTI-LINK DUET Registry demonstrates enhanced procedural performance with clinical and angiographic outcomes similar to those previously observed for the MULTI-LINK stent in the ASCENT randomized trial.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Disease/therapy , Stents , Aged , Cause of Death , Coronary Disease/diagnostic imaging , Coronary Disease/mortality , Equipment Failure Analysis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Myocardial Infarction/mortality , Prospective Studies , Prosthesis Design , Radiography , Survival Rate , Treatment Outcome
7.
J Am Coll Cardiol ; 16(7): 1594-600, 1990 Dec.
Article in English | MEDLINE | ID: mdl-2254543

ABSTRACT

Conventional coronary arteriography is able to demonstrate the presence of coronary collateral vessels but cannot delineate the specific region of myocardium to which they supply blood. To test the hypothesis that contrast echocardiography can specifically identify collateralized myocardium, contrast echocardiographic perfusion "maps" were compared in patients with (n = 12) and without (n = 12) angiographic evidence of coronary collateral flow, both before and after coronary angioplasty. Contrast echocardiographic images of the mid-left ventricle in the short-axis view at end-diastole were obtained after separate injections of a sonicated contrast agent into both the right and the left coronary arteries. A computer-based contouring system was used to determine the individual areas of myocardium perfused by each of the two coronary arteries and then to superimpose the images of the two perfusion beds. The resulting area of overlapping perfusion represented myocardium receiving blood flow from both coronary systems and was defined as collateralized myocardium. To normalize for heart size, overlap area was expressed as a percent of total myocardial area, which was the area between endocardium and epicardium in the short-axis view. To adjust for differences in vascular distribution, overlap area was expressed as a percent of the perfusion area of the recipient vessel. In patients with angiographic collateral flow, the recipient vessel was that vessel receiving the collateral flow. In patients without angiographic collateral flow, the right coronary artery was considered the recipient vessel. Overlap area was 1.3 +/- 0.4% of total myocardial area and 6.6 +/- 1.7% of recipient vessel area in patients without angiographic evidence of collateral flow compared with 30.6 +/- 2.5% and 89.2 +/- 6.4%, respectively, in patients with angiographic collateral flow (p less than 0.001 for both). In four patients in whom angiographic collateral flow was abolished by angioplasty, overlap area decreased from 30.3 +/- 5.3% to 6.8 +/- 2.7% of total myocardial area and from 100% to 18.5 +/- 5.4% of recipient vessel area (p less than 0.05 for both). Thus, contrast echocardiography is able to map the specific myocardial territory perfused by coronary collateral flow and document an immediate reduction in perfusion in this territory when collateral flow is abolished by angioplasty.


Subject(s)
Angioplasty, Balloon, Coronary , Collateral Circulation/physiology , Coronary Circulation/physiology , Coronary Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Echocardiography , Image Processing, Computer-Assisted , Coronary Disease/therapy , Female , Humans , Male , Middle Aged
8.
J Am Coll Cardiol ; 16(5): 1201-4, 1990 Nov.
Article in English | MEDLINE | ID: mdl-2229767

ABSTRACT

Because of the distortion of atrial morphology that occurs during cardiac allograft transplantation in humans, the beneficial effects of properly sequenced atrial and ventricular activation are unclear in these patients. To evaluate the atrial contribution to ventricular pump performance in heart transplant recipients, arterial pressure and cardiac output during pacing from either chamber were measured in nine patients 10 +/- 1 days after transplantation. Systolic, diastolic and mean systemic arterial pressures were significantly higher during atrial pacing compared with ventricular pacing: 143 +/- 23 versus 125 +/- 20 mm Hg, 73 +/- 15 versus 66 +/- 14 mm Hg and 94 +/- 17 versus 84 +/- 16 mm Hg, respectively (p less than 0.05 for all). In addition, cardiac output decreased from 5.5 +/- 1.4 to 4.6 +/- 1.5 liters/min (p less than 0.005) for atrial versus ventricular pacing. Thus, there is a significant atrial contribution to cardiac performance in patients after heart transplantation. This may have clinical implications in those patients who later require a permanent pacemaker.


Subject(s)
Atrial Function/physiology , Cardiac Pacing, Artificial/methods , Heart Transplantation , Pacemaker, Artificial , Blood Pressure/physiology , Cardiac Output/physiology , Electrocardiography , Female , Heart Transplantation/physiology , Humans , Male , Middle Aged , Ventricular Function/physiology
9.
J Am Coll Cardiol ; 16(2): 489-94, 1990 Aug.
Article in English | MEDLINE | ID: mdl-2373828

ABSTRACT

Epinephrine promotes resuscitation from ventricular fibrillation because of its peripheral vasoconstrictive effects. However, the beta-adrenergic effects of epinephrine may be detrimental because of the stimulation of myocardial oxygen demand. To test whether functional recovery from fibrillation in hearts treated with a selective alpha-adrenergic agent is greater than in hearts treated with epinephrine, ventricular fibrillation was induced in eight isolated dog hearts while coronary perfusion pressure was maintained at 30 mm Hg. In random order, epinephrine (5 micrograms/min), phenylephrine (50 micrograms/min) or no drug was infused for 5 min. The heart was then defibrillated, the drug infusion stopped and coronary perfusion pressure increased to 100 mm Hg. Coronary blood flow (ml/min per 100 g), arteriovenous oxygen difference (ml O2/dl) and myocardial oxygen consumption (ml O2/min per 100 g) measured after 4 min of ventricular fibrillation were greater with epinephrine (mean +/- SD 30.9 +/- 11.7, 17.5 +/- 1.6 and 5.4 +/- 1.9, respectively) than with phenylephrine (24.4 +/- 6.0, 15.7 +/- 2.6 and 3.8 +/- 1.1, respectively) or no drug (19.8 +/- 5.2, 12.8 +/- 1.8 and 2.6 +/- 0.7, respectively) (p less than 0.05, p less than 0.05 and p less than 0.05, respectively). The slope of the end-systolic pressure-volume relation 10 min after defibrillation and restoration of normal coronary perfusion pressure was depressed (percent of prefibrillation value) most by epinephrine infusion (72 +/- 17%, n = 6), less by no drug infusion (82 +/- 12%, n = 4) and was increased after phenylephrine infusion (143 +/- 17%, n = 6) (p less than 0.002).(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Phenylephrine/therapeutic use , Ventricular Fibrillation/drug therapy , Animals , Coronary Circulation/drug effects , Dogs , Epinephrine/therapeutic use , Heart Ventricles/drug effects , In Vitro Techniques , Oxygen Consumption/drug effects , Pressure , Resuscitation , Ventricular Fibrillation/physiopathology , Ventricular Function
10.
Cathet Cardiovasc Diagn ; 20(2): 77-83, 1990 Jun.
Article in English | MEDLINE | ID: mdl-2354519

ABSTRACT

Restenosis following coronary angioplasty can usually be treated effectively and safely by repeated angioplasty. However, the presence of a complex lesion morphology may bias the clinician away from angioplasty toward either recommending bypass surgery or continuing medical therapy alone in spite of recurrence of the symptoms which were sufficient indication for the initial angioplasty. One type of complex morphology at the site of the restenosis is due to the presence of a focal, eccentric aneurysmal dilatation similar in appearance to a saccular aneurysm. In two previously reported cases in the literature both were referred to bypass surgery. We report eight additional cases including the use of repeat successful angioplasty in six of the cases in spite of the potential problems posed by the complexity of the restenosed lesion. In addition, this case review suggests that this type of complex lesion morphology with restenosis may be more common when the initial angioplasty was associated with deep arterial injury, as in patients whose initial angioplasty was done in an infarct-related vessel or was associated with evidence of a large dissection.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Aneurysm/therapy , Adult , Aged , Angiography , Constriction, Pathologic/therapy , Coronary Aneurysm/diagnostic imaging , Coronary Aneurysm/etiology , Coronary Angiography , Coronary Disease/therapy , Female , Humans , Male , Middle Aged , Recurrence , Reoperation , Time Factors
11.
Circulation ; 81(3): 922-8, 1990 Mar.
Article in English | MEDLINE | ID: mdl-2306840

ABSTRACT

The clinical and pathologic features of 18 consecutive patients with peripartum cardiomyopathy at The Johns Hopkins Hospital were examined in an attempt to define the incidence of myocarditis and to determine its response to immunosuppressive agents. In addition to routine studies, patients were evaluated with echocardiography, nuclear ventriculography, right heart catheterization, and myocardial biopsy. Fourteen of the 18 patients (78%) showed evidence of myocarditis. Of these, 10 were treated with immunosuppressive therapy. Nine of the 10 treated patients with myocarditis had subjective and objective improvement. Follow-up endomyocardial biopsies in these patients showed resolution or substantial improvement in myocarditis. Four patients with myocarditis not treated with immunosuppressives also improved. All patients improving spontaneously presented with congestive heart failure within 1 month of delivery and improved dramatically within days of presentation. Four of the 18 patients showed no evidence of myocarditis. Of these, two improved, and two deteriorated (both requiring cardiac transplantation). None of these four patients were treated with immunosuppressive therapy. We conclude that in patients with peripartum cardiomyopathy, 1) the etiology remains unclear although myocarditis was present in 78% of those with this condition, 2) resolution of myocarditis is associated with significant improvement in left ventricular function, 3) myocarditis may resolve spontaneously without detectable loss of cardiac function, and 4) immunosuppressive therapy in patients with myocarditis and persistent left ventricular dysfunction may improve left ventricular function and prognosis.


Subject(s)
Cardiomyopathy, Dilated , Myocarditis , Pregnancy Complications, Cardiovascular , Puerperal Disorders , Adult , Azathioprine/therapeutic use , Cardiomyopathy, Dilated/diagnosis , Cardiomyopathy, Dilated/drug therapy , Female , Humans , Immunosuppression Therapy , Myocarditis/diagnosis , Myocarditis/drug therapy , Prednisone/therapeutic use , Pregnancy , Pregnancy Complications, Cardiovascular/diagnosis , Pregnancy Complications, Cardiovascular/drug therapy , Puerperal Disorders/diagnosis , Puerperal Disorders/drug therapy
12.
Circulation ; 81(2): 447-60, 1990 Feb.
Article in English | MEDLINE | ID: mdl-2297855

ABSTRACT

The influence of acute coronary occlusion on systolic and diastolic left ventricular pressure-volume relations was studied in 10 patients undergoing percutaneous transluminal coronary angioplasty (PTCA). Pressure-volume relations were obtained by conductance catheter and micromanometer techniques and with volume load altered by transient inferior vena caval occlusion. End-systolic and end-diastolic pressure-volume relations were obtained at baseline, during 60-90 seconds of ischemia, and at return to baseline after angioplasty balloon deflation. Coronary occlusion significantly altered systolic and diastolic chamber function. Systolic dysfunction was characterized by a reproducible rightward shift of the end-systolic pressure-volume relation (+25.4 +/- 18.4 ml) that was greater for proximal left anterior descending and circumflex coronary artery occlusions (+41 ml) than for distal or right coronary artery occlusions (+15.4 ml, p less than 0.05). Occlusion also lowered chamber systolic function indexes, such as the end-systolic pressure-volume relation slope (from 4.2 to 2.8 mm Hg/ml) and preload recruitable stroke work (from 97 to 78.6 mm Hg). All systolic (and diastolic) changes were resolved with successful angioplasty. Diastolic abnormalities during angioplasty were characterized by prolonged pressure relaxation and an upward shift of the resting diastolic pressure-volume data and by an apparent increase in chamber elastic stiffness. However, when end-diastolic data from multiple beats during inferior vena caval occlusion were compared, control and ischemic end-diastolic pressure-volume relations displayed little or no difference. Thus, elevations in resting diastolic pressure-volume relations and apparent increase in chamber elastic stiffness during coronary occlusion in humans appear dominated by altered right ventricular or pericardial loading. These data indicate that pressure-volume analysis is useful in assessing the functional significance of coronary lesions and reperfusion.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Vessels/physiology , Myocardial Contraction/physiology , Stroke Volume/physiology , Arterial Occlusive Diseases/physiopathology , Cardiac Volume/physiology , Constriction , Coronary Disease/physiopathology , Female , Humans , Male , Time Factors , Vena Cava, Inferior/physiology
13.
Pacing Clin Electrophysiol ; 12(5): 752-6, 1989 May.
Article in English | MEDLINE | ID: mdl-2471160

ABSTRACT

One of the determinants of the capture threshold of an endocardial pacing lead is the configuration of the electrode tip. To evaluate whether micro- and macroporous electrodes have better initial and chronic thresholds than nonporous electrodes, acute and chronic capture thresholds, stimulation impedance and sensing thresholds were determined in 22 patients in whom a ventricular ring-tip electrode and a unipolar, dual chamber pacemaker with bidirectional telemetry had been implanted. These values were compared to those obtained from 25 patients receiving an electrode constructed with a platinized groove surface at the time of implant of an identical pulse generator. The ventricular capture threshold at implant was 0.7 V +/- 0.3 at 0.6 msec pulse width for both groups. The capture threshold was significantly greater in the ring tip electrode group at follow-up periods of 1 month (1.1 V +/- 0.5 vs 1.6 V +/- 0.6, P less than 0.008), 4 months (1.0 V +/- 0.2 vs 1.7 V +/- 0.8, P less than 0.002), and 10 months (1.2 V +/- 0.4 vs 1.7 V +/- 0.5, P less than 0.04) following implantation. The stimulation impedance at the time of implantation was lower in the ring-tip electrode group (530 ohms vs 603 ohms, P less than 0.03), but thereafter no significant difference was seen between the two groups. The acute and chronic sensing thresholds were similar in both groups. While the microporous electrode had significantly lower chronic capture thresholds, the magnitude of this difference is small, and probably clinically inconsequential.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Electrodes, Implanted/standards , Pacemaker, Artificial , Aged , Equipment Design , Female , Follow-Up Studies , Humans , Male , Platinum , Time Factors
14.
Pacing Clin Electrophysiol ; 12(2): 392-7, 1989 Feb.
Article in English | MEDLINE | ID: mdl-2468150

ABSTRACT

A patient having high grade AV block with intact sinus node function is presented in whom DDDR pacing provided the benefit of preventing 2:1 pacemaker block in response to exercise-induced sinus tachycardia. In paired treadmill tests with the patient blinded as to pacing mode, she was able to exercise longer (7.5 vs 6.6 METS) when programmed in DDDR than in DDDO. This is attributable to circumvention of 2:1 pacemaker block which had resulted in abrupt onset of fatigue and SOB (shortness of breath) when the sinus rate exceeded the maximum tracking rate of 130/min. Outpatient ambulatory electrocardiographic monitoring confirmed this phenomenon during relatively strenuous activity. The theoretic advantages of dual chamber rate modulated pacing compared to the DDDO and VVIR modes are discussed.


Subject(s)
Pacemaker, Artificial , Cardiac Output , Electrocardiography , Exercise Test , Female , Heart Block/therapy , Heart Rate , Humans , Middle Aged , Tachycardia, Sinus/etiology , Tachycardia, Sinus/therapy
15.
Chest ; 94(2): 245-50, 1988 Aug.
Article in English | MEDLINE | ID: mdl-3396398

ABSTRACT

Percutaneous aortic valvuloplasty using a single dilating balloon has been associated with significant but modest reduction in transvalvular pressure gradient and increase in valve area. The balloon diameter is usually 20 mm or smaller to avoid disruption of aortic root structure and to permit forward blood flow during inflation. To evaluate the safety and efficacy of valvuloplasty using a combination of balloons with larger maximum inflated diameters, we compared results of aortic valvuloplasty in 21 patients using either the single or double balloon technique. Mean maximum inflated balloon diameter was 19.4 mm +/- 1.4 for the single balloon technique, while the mean sum of diameters for the simultaneous double balloon technique was 36.3 mm +/- 3.9. The mean age, aortic annulus diameter, and predilatation aortic valve area were not different among groups. Mean aortic transvalvular gradient reduction and mean aortic valve area increase were greater for the double balloon technique. The procedure was well tolerated with no major complications. No change in the degree of aortic regurgitation was noted. The double balloon technique for aortic valvuloplasty is safe and more effective at improving aortic valve area and transvalvular gradient than the conventional single balloon technique.


Subject(s)
Aortic Valve Stenosis/therapy , Catheterization/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/physiopathology , Catheterization/instrumentation , Echocardiography , Equipment Design , Female , Hemodynamics , Humans , Male
16.
Cathet Cardiovasc Diagn ; 15(3): 192-202, 1988.
Article in English | MEDLINE | ID: mdl-3197110

ABSTRACT

Determination of left ventricular pressure-volume relationships in situ ideally requires both a method for easy measurement of multiple pressure-volume loops and a rapid and reversible means of altering load. We report a technique, previously used in animals, that combines conductance catheter volumes and rapid inferior vena caval occlusion to permit routine measurement of calibrated P-V relationships in man for the first time. An 8F volume catheter with a 3F micromanometer tipped pressure catheter placed through its lumen was advanced to the left ventricular apex through a femoral artery. A thermodilution output catheter was placed through a 9F femoral venous sheath and later replaced with an IVC balloon occlusion catheter, through which a 2.5F bipolar wire was advanced for atrial pacing. A specialized data system facilitated collection, editing, and data analysis at the time of cardiac catheterization. Absolute volume calibration required cardiac output measurement and injection of hypertonic saline. IVC occlusion decreased peak left ventricular pressure by 42 +/- 17 (SD) (P less than .001) mm Hg in 15 patients. Endsystolic pressure-volume relationships (ESPVR) were determined with 5-8 cardiac cycles with an average of r2 of 0.94 +/- 0.05 and were generally reproducible. The slope of the ESPVR demonstrated consistency among a group of normal patients (n = 6), and was significantly lower than the slope derived from a group of patients with ventricular hypertrophy (n = 9). We conclude that left ventricular pressure-volume relationships can be easily and repeatedly determined as part of a routine cardiac catheterization in man.


Subject(s)
Cardiac Catheterization , Myocardial Contraction , Stroke Volume , Vena Cava, Inferior/physiology , Calibration , Cardiac Output , Cardiac Pacing, Artificial , Catheterization/instrumentation , Constriction , Dobutamine , Female , Humans , Male , Microcomputers , Signal Processing, Computer-Assisted , Transducers, Pressure
17.
Ann Biomed Eng ; 15(3-4): 347-59, 1987.
Article in English | MEDLINE | ID: mdl-3662151

ABSTRACT

To determine whether or not extracardiac pressure has an effect on left ventricular contractile function, we analyzed pressure-volume relationships of six isolated, perfused canine hearts in an air-tight chamber. The chamber pressure was set at -60, -30, 0, 30 and 60 mm Hg and left ventricular pressure-volume relationships studied. The slope (Ees) and volume axis intercept (Vo) of the transmural pressure-volume relationship were used to compare the pump functions of an individual heart at the different extracardiac pressures applied. No significant difference in either Ees or Vo was seen with different extracardiac pressures. During isovolumic ventricular contraction, developed left ventricular pressure did not change over the range of extracardiac pressures applied. The same was true during ejecting contraction; when the downstream pressure of the computer simulated afterload circuit and the venous filling pressure of the preload circuit were changed in parallel with the extracardiac pressure, pressure-volume loops remained identical throughout their course for all of the extracardiac pressures applied. We conclude that transmural pressure is the overwhelmingly dominant loading factor governing LV contraction, and myocardial contractile function is unaffected by the absolute value of extracardiac pressure.


Subject(s)
Myocardial Contraction , Thorax/physiology , Animals , Dogs , Heart Ventricles , In Vitro Techniques , Physiology/instrumentation , Pressure
SELECTION OF CITATIONS
SEARCH DETAIL
...