Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biomicrofluidics ; 16(2): 024108, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35464137

ABSTRACT

Drug-induced liver injury (DILI) results in over 100 000 hospital attendances per year in the UK alone and is a leading cause for the post-marketing withdrawal of new drugs, leading to significant financial losses. MicroRNA-122 (miR-122) has been proposed as a sensitive DILI marker although no commercial applications are available yet. Extracellular blood microRNAs (miRNAs) are promising clinical biomarkers but their measurement at point of care remains time-consuming, technically challenging, and expensive. For circulating miRNA to have an impact on healthcare, a key challenge to overcome is the development of rapid and reliable low-cost sample preparation. There is an acknowledged issue with miRNA stability in the presence of hemolysis and platelet activation, and no solution has been demonstrated for fast and robust extraction at the site of blood draw. Here, we report a novel microfluidic platform for the extraction of circulating miR-122 from blood enabled by a vertical approach and gravity-based bubble mixing. The performance of this disposable cartridge was verified by standard quantitative polymerase chain reaction analysis on extracted miR-122. The cartridge performed equivalently or better than standard bench extraction kits. The extraction cartridge was combined with electrochemical impedance spectroscopy to detect miR-122 as an initial proof-of-concept toward an application in point-of-care detection. This platform enables the standardization of sample preparation and the detection of miRNAs at the point of blood draw and in resource limited settings and could aid the introduction of miRNA-based assays into routine clinical practice.

2.
Nano Lett ; 12(2): 1058-62, 2012 Feb 08.
Article in English | MEDLINE | ID: mdl-22208801

ABSTRACT

By varying the relative dimensions of the central and peripheral disks of a plasmonic nanocluster, the depth of its Fano resonance can be systematically modified; spectral windows where the scattering cross section of the nanocluster is negligible can be obtained. In contrast, electron-beam excitation of the plasmon modes at specific locations within the nanocluster yields cathodoluminescence spectra with no Fano resonance. By examining the selection rules for plasmon excitation in the context of a coupled oscillator picture, we provide an intuitive explanation of this behavior based on the plasmon modes observed for optical and electron-beam excitation in this family of nanostructures.


Subject(s)
Nanostructures/chemistry , Surface Plasmon Resonance , Particle Size
SELECTION OF CITATIONS
SEARCH DETAIL
...