Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Eur J Heart Fail ; 15(9): 1003-10, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23645499

ABSTRACT

AIMS: We examined whether the severity of central sleep apnoea (CSA) and the level of C-reactive protein are associated with the prevalence and complexity of arrhythmias, and whether these factors contribute to increased risk of nocturnal sudden death. METHODS AND RESULTS: We prospectively examined 178 patients (age 70 ± 1 years) who were admitted to our hospital due to worsening heart failure. We recorded a simultaneous overnight cardiorespiratory polygraph and Holter ECG. Obstructive sleep apnoea was excluded and patients were dichotomized based on the median value of the central apnoea index (CAI) of 7.5/h. The prevalence and complexity of arrhythmias were compared between daytime (06:00 h to 15:00 h) and night-time (21:00 h to 06:00 h). A multivariate logistic regression analysis revealed that the CAI was associated with prevalence of atrial fibrillation (AF) [odds ratio 1.03, 95% confidence interval (CI) 1.02-2.51)] and sinus pause during the night-time period (1.12, 95% CI 1.08-1.35). The CAI and C-reactive protein were independently associated with non-sustained ventricular tachycardia during both daytime (1.22, 95% CI 1.00-6.92; and 5.82, 2.58-56.1, respectively) and night-time periods (3.57, 95% CI 1.06-13.1; and 10.7, 3.30-44.4, respectively). During a mean follow-up period of 22 months, 30 (17%) patients had cardiovascular deaths and the CSA was an independent predictor (hazard ratio 1.29, 95% CI 1.16-2.32); only 5 (2.8%) of them died due to ventricular tachyarrhythmia, occurring during wakefulness. CONCLUSIONS: We demonstrated that the severity of CSA and C-reactive protein levels are independently associated with the prevalence and complexity of arrhythmias. CSA was associated with increased mortality risk, but it was not related directly to nocturnal death due to ventricular tachyarrhythmia.


Subject(s)
Arrhythmias, Cardiac/etiology , C-Reactive Protein/metabolism , Death, Sudden, Cardiac/epidemiology , Heart Failure/complications , Inflammation/complications , Sleep Apnea, Central/complications , Aged , Death, Sudden, Cardiac/etiology , Echocardiography , Electrocardiography, Ambulatory , Female , Follow-Up Studies , Humans , Inflammation/blood , Logistic Models , Male , Middle Aged , Polysomnography , Prevalence , Prospective Studies , Risk Factors , Sleep Apnea, Central/blood
2.
Sleep Breath ; 17(2): 589-95, 2013 May.
Article in English | MEDLINE | ID: mdl-22707086

ABSTRACT

PURPOSE: The SD-101 is a non-restrictive sheet-like medical device that measures sleep-disordered breathing using pressure sensors that can detect the gravitational alterations in the body that accompany respiratory movement. One report has described that the screening specificity of the SD-101 for mild to moderate obstructive sleep apnea syndrome (OSAS) is relatively low. The present study examines whether the accuracy of the SD-101 for OSAS screening is improved by simultaneously measuring percutaneous oxygen saturation (SpO2). METHODS: Sixty consecutive individuals with suspected OSAS consented to undergo overnight polysomnography (PSG) together with simultaneous measurements of SD-101 and SpO2 at our laboratory. RESULTS: The apnea-hypopnea index (AHI) determined from PSG and the respiratory disturbance index determined from SD-101 measurements significantly correlated (SD-101 alone: r = 0.871, p < 0.0001; SD-101 with SpO2: r = 0.965, p < 0.0001). Bland-Altman plots showed a smaller dispersion for the SD-101 with SpO2 than for the SD-101 alone. The SD-101 with SpO2 detected an AHI of >15 on PSG with a sensitivity and specificity of 96.9 and 90.5 % compared with 87.5 and of 85.7 %, respectively, of the SD-101 alone. CONCLUSIONS: Simultaneously measuring SpO2 improved the accuracy of the SD-101 for OSAS screening. Furthermore, this modality appears to offer high sensitivity and specificity for detecting even moderately severe OSAS.


Subject(s)
Mass Screening/instrumentation , Point-of-Care Systems , Polysomnography/instrumentation , Sleep Apnea, Obstructive/diagnosis , Adult , Aged , Equipment Design , Female , Humans , Japan , Male , Middle Aged , Outpatient Clinics, Hospital , Oxygen/blood , Predictive Value of Tests , Statistics as Topic
3.
Gan To Kagaku Ryoho ; 35(9): 1591-3, 2008 Sep.
Article in Japanese | MEDLINE | ID: mdl-18799918

ABSTRACT

A 64-year old man first visited our clinic approximately 10 years ago because of diabetic nephropathy that had developed into chronic renal failure. He was hospitalized to examine a left S10 tumor shadow. Based on the results of these examinations, a primary left S10 T2N0M1, ED small cell lung cancer, was diagnosed. During his outpatient visits nephropathy was found. Following admission, he began dialysis (HD). During the detailed examinations, chemotherapy with amrubicin (AMR)was performed and the blood concentration of the drug was measured. The results showed no significant variations in blood concentration before and after the dialysis. While PR was achieved in this patient, a reduction in grade 4 eosinophils was observed as an adverse reaction.


Subject(s)
Anthracyclines/adverse effects , Anthracyclines/therapeutic use , Carcinoma, Small Cell/drug therapy , Carcinoma, Small Cell/pathology , Kidney Failure, Chronic/complications , Lung Neoplasms/drug therapy , Lung Neoplasms/pathology , Anthracyclines/blood , Carcinoma, Small Cell/complications , Carcinoma, Small Cell/diagnostic imaging , Humans , Lung Neoplasms/complications , Lung Neoplasms/diagnostic imaging , Male , Middle Aged , Neoplasm Staging , Tomography, X-Ray Computed
4.
Nihon Kokyuki Gakkai Zasshi ; 46(3): 181-8, 2008 Mar.
Article in Japanese | MEDLINE | ID: mdl-18409562

ABSTRACT

The SD-101 (Kenzmedico co. Ltd., Saitama, Japan), a non-invasive medical device capable of measuring respiratory parameters during sleep, has recently been developed. It operates while placed under the body like a bed pad equipped with 162 pressure sensors, with the patient in bed. To evaluate the efficacy and safety of the SD-101 for the diagnosis of sleep apnea syndrome (SAS), we enrolled 52 patients with suspected SAS (45 men and 7 women; mean age, 45.6 +/- 10.9 years) in this study. Each subject underwent measurement using the SD-101 and a polysomnograph simultaneously, and we analyzed and compared them. In addition, health-economic benefits of the SD-101 were estimated based on the results. A significantly strong correlation was obtained between the apnea hypopnea index of PSG and its of SD-101 (r = 0.86, p < 0.0001). No adverse event due to the SD-101 occurred, while use of the SD-101 greatly reduced "feeling of being constrained" and discomfort during examination (Wilcoxon test: p < 0.0001). These findings could indicate that the SD-101 is clinically useful and will make a contribution to health-economic benefits for SAS in Japan.


Subject(s)
Equipment and Supplies/standards , Sleep Apnea Syndromes/diagnosis , Adult , Equipment Safety , Equipment and Supplies/economics , Female , Humans , Male , Middle Aged , Polysomnography
SELECTION OF CITATIONS
SEARCH DETAIL
...