Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Vasc Interv Radiol ; 27(8): 1105-1114.e3, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27388566

ABSTRACT

PURPOSE: To present final, 2-year data from randomized comparison of an expanded polytetrafluoroethylene stent graft (SG) and percutaneous transluminal angioplasty (PTA) for treatment of arteriovenous graft (AVG) anastomotic stenoses. MATERIALS AND METHODS: A 28-site, prospective, controlled US study enrolled 270 patients with malfunctioning AVG anastomotic stenoses of ≥ 50%; 138 patients underwent SG placement, and 132 underwent PTA alone. Follow-up imaging and intervention were event-driven. RESULTS: The study was completed by 191 patients (97 SG, 94 PTA). Five patients were lost to follow-up or withdrew; 74 patients died during the study (38 SG, 36 PTA). At 12 months, treatment area primary patency (TAPP) was SG 47.6% versus PTA 24.8% (P < .001), access circuit primary patency (ACPP) was SG 24% versus PTA 11% (P = .007), and index of patency function (IPF) was SG 5.2 months/intervention ± 4.1 versus PTA 4.4 months/intervention ± 3.5 (P = .009). At 24 months, TAPP was SG 26.9% versus PTA 13.5% (P < .001), ACPP was SG 9.5% versus PTA 5.5% (P = .01), and IPF was SG 7.1 months/intervention ± 7.0 versus PTA 5.3 months/intervention ± 5.2; estimated number of reinterventions before graft abandonment was 3.4 for SG patients versus 4.3 for PTA patients. There were no significant differences in adverse events (P > .05) except for restenosis requiring reintervention rates of 82.6% in PTA patients versus 63.0% in SG patients (P < .001). CONCLUSIONS: At 2 years, SG use provided a sustained, greater than 2-fold advantage over PTA in treatment area and overall access patency. Time to subsequent intervention was longer in the SG group.


Subject(s)
Angioplasty, Balloon , Arteriovenous Shunt, Surgical/adverse effects , Graft Occlusion, Vascular/therapy , Renal Dialysis , Aged , Angioplasty, Balloon/adverse effects , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Male , Middle Aged , Polytetrafluoroethylene , Product Surveillance, Postmarketing , Prospective Studies , Prosthesis Design , Retreatment , Stents , Time Factors , Treatment Outcome , United States , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...